Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Int J Technol Assess Health Care ; 40(1): e2, 2024 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-38179661

RESUMO

OBJECTIVES: Lack of evidence regarding safety and effectiveness at market entry is driving the need to consider adopting a lifecycle approach to evaluating medical devices, but it is unclear what lifecycle evaluation means. This research sought to explore the tacit meanings of "lifecycle" and "lifecycle evaluation" as embodied within evaluation models/frameworks used for medical devices. METHODS: Drawing on qualitative evidence synthesis methods and using an inductive approach, novel methods were developed to identify, appraise, analyze, and synthesize lifecycle evaluation models used for medical devices. Data was extracted (including purpose; audience; characterization; outputs; timing; and type of model) from key texts for coding, categorization, and comparison, exploring embodied meaning across four broad perspectives. RESULTS: Fifty-two models were included in the synthesis. They demonstrated significant heterogeneity of meaning, form, scope, timing, and purpose. The "lifecycle" may represent a single stage, a series of stages, a cycle of innovation, or a system. "Lifecycle evaluation" focuses on the overarching goal of the stakeholder group, and may use a single or repeated evaluation to inform decision-making regarding the adoption of health technologies (Healthcare), resource allocation (Policymaking), investment in new product development or marketing (Trade and Industry), or market regulation (Regulation). The adoption of a lifecycle approach by regulators has resulted in the deferral of evidence generation to the post-market phase. CONCLUSIONS: Using a "lifecycle evaluation" approach to inform reimbursement decision-making must not be allowed to further jeopardize evidence generation and patient safety by accepting inadequate evidence of safety and effectiveness for reimbursement decisions.


Assuntos
Equipamentos e Provisões , Formulação de Políticas , Equipamentos e Provisões/normas
2.
Orphanet J Rare Dis ; 18(1): 212, 2023 07 25.
Artigo em Inglês | MEDLINE | ID: mdl-37491269

RESUMO

AIM: To determine the level of evidence for innovative high-risk medical devices at market entry. METHODS: We reviewed all Belgian healthcare payer (RIZIV-INAMI) assessor reports on novel implants or invasive medical devices (n = 18, Class IIb-III) available between 2018 to mid-2019 on applications submitted for inclusion on their reimbursement list. We also conducted a review of the literature on evidence gaps and an analysis of relevant legal and ethical frameworks within the European context. FINDINGS: Conformity assessment of medical devices is based on performance, safety, and an acceptable risk-benefit balance. Information submitted for obtaining CE marking is confidential and legally protected, limiting access to clinical evidence. Seven out of the 18 RIZIV-INAMI assessor reports (39%) included a randomized controlled trial (RCT) using the novel device, whilst 2 applications (11%) referred to an RCT that used a different device. The population included was inappropriate or unclear for 3 devices (17%). Only half of the applications presented evidence on quality of life or functioning and 2 (11%) presented overall survival data. Four applications (22%) included no data beyond twelve months. The findings from the literature demonstrated similar problems with the study design and the clinical evidence. DISCUSSION AND CONCLUSIONS: CE marking does not indicate that a device is effective, only that it complies with the law. The lack of transparency hampers evidence-based decision making. Despite greater emphasis on clinical benefit for the patient, the provisions of the European Medical Device Regulation (MDR) are not yet fully aligned with international ethical standards for clinical research. The MDR fails to address key issues, such as the lack of access to data submitted for CE marking and a failure to require evidence of clinical effectiveness. Indeed, a first report shows no improvement in the clinical evidence for implantable devices generated under the MDR. Thus, patients may continue to be exposed to ineffective or unsafe novel devices. The Health Technology Assessment Regulation plans for Joint Scientific Consultations for specific high-risk devices before companies begin their pivotal clinical investigations. The demanded comparative evidence should facilitate payer decisions. Nevertheless, there is also a need for legislation requiring comparative RCTs assessing patient-relevant outcomes for high-risk devices to ensure implementation, including development and implementation of common specifications for study designs.


Assuntos
Projetos de Pesquisa , Avaliação da Tecnologia Biomédica , Humanos , Europa (Continente) , Medição de Risco , Resultado do Tratamento , Ensaios Clínicos Controlados Aleatórios como Assunto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA