Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Sensors (Basel) ; 19(11)2019 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-31181845

RESUMO

Ratio transformation methods are widely used for image fusion of high-resolution optical satellites. The premise for the use the ratio transformation is that there is a zero-bias linear relationship between the panchromatic band and the corresponding multi-spectral bands. However, there are bias terms and residual terms with large values in reality, depending on the sensors, the response spectral ranges, and the land-cover types. To address this problem, this paper proposes a panchromatic and multi-spectral image fusion method based on the panchromatic spectral decomposition (PSD). The low-resolution panchromatic and multi-spectral images are used to solve the proportionality coefficients, the bias coefficients, and the residual matrixes. These coefficients are substituted into the high-resolution panchromatic band and decompose it into the high-resolution multi-spectral bands. The experiments show that this method can make the fused image acquire high color fidelity and sharpness, it is robust to different sensors and features, and it can be applied to the panchromatic and multi-spectral fusion of high-resolution optical satellites.

2.
Opt Express ; 26(6): 7475-7493, 2018 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-29609301

RESUMO

To increase the field of view (FOV), combining multiple time-delayed and integrated charge-coupled devices (TDI-CCD) into the camera and the pushbroom imaging modality are traditionally used with high-resolution optical satellites. It is becoming increasingly labor- and cost-intensive to build and maintain a calibration field with high resolution and broad coverage. This paper introduces a simple and feasible on-orbit geometric self-calibration approach for high-resolution multi-TDI-CCD optical satellites based on three-view stereoscopic images. With the aid of the a priori geometric constraint of tie points in the triple-overlap regions of stereoscopic images, as well as tie points between adjacent single TDI-CCD images (STIs), high accuracy calibration of all TDI-CCD detectors can be achieved using a small number of absolute ground control points (GCPs) covering the selected primary STI. This method greatly reduces the demand on the calibration field and thus is more time-, effort- and cost-effective. Experimental results indicated that the proposed self-calibration approach is effective for increasing the relative internal accuracy without the limitations associated with using a traditional reference calibration field, which could have great significance for future super-high-resolution optical satellites.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA