Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 89
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-39075813

RESUMO

BACKGROUND: Catheter Ablation (CA) is an effective treatment for atrial fibrillation (AF). However, frail elderly patients have been understudied due to their exclusion from landmark trials. OBJECTIVES: Our study aims to evaluate outcomes in this population. METHODS: The national readmission database (2016-2020) was queried, and frailty categories were defined based on hospital risk frailty scores ≦5 as low while >5 as intermediate/high frailty (IHF). We used multivariate regression and propensity-matched analysis to compare outcomes in patients undergoing CA for atrial fibrillation based on frailty index. RESULTS: Among 55 936 CAs for AF, 33,248 patients had low frailty, while 22 688 had intermediate/high frailty (IHF). After propensity matching (N 12 448), IHF patients were found to have higher adverse events, including mortality (3% vs. 0.3%, p < .001), stroke (1.9% vs. 0.2%, p < .001), acute heart failure (53.8% vs. 42.2%, p < .001), AKI (42.5% vs. 6.8%, p < .001), pericardial complications (2.8 vs. 1.6%, p < .001), respiratory complications (27.8 vs. 7.2%, p < .001), major adverse cardiovascular events (21.2 vs. 9.4%, p < .001) and net adverse events (76.7 vs. 55%, p < .001). IHF patients had higher readmissions at 30 (15.5 vs. 12.6%, p < .001), 90 (31.9 vs. 25.1%, p < .001), and 180-day (41 vs. 34.7%, p < .001) intervals. A higher median length of stay (LOS) (7 vs. 3 days, p < .001) and cost ($44 287 vs. $27 517, p < .001) at index admission and subsequent readmissions were also observed (p < .001). CONCLUSION: Intermediate/high frailty patients undergoing catheter ablation had worse clinical outcomes, higher healthcare burden, and readmission rates. LOS has decreased in both groups from 2016 to 2020; however, total cost has increased.

2.
Catheter Cardiovasc Interv ; 99(3): 777-785, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34708916

RESUMO

This document provides an overview of the rationale, development, interpretation, and practical suggestions for implementation of the new Accreditation Council for Graduate Medical Education (ACGME) Interventional Cardiology (IC) Milestones 2.0. Previously, IC programs used the general ACGME Milestones for internal medicine. The IC Milestones version 2.0 updates the ACGME competencies to be specific to training in IC. In 2019 an ACGME working group consisting of IC program directors, a lay representative, and representatives from the American Board of Internal Medicine met to develop the IC Milestones version 2.0. The ACGME IC Milestones 2.0 establishes a framework for formative feedback for trainees within domains of patient care, medical knowledge, systems-based practice, practice-based learning and improvement, professionalism, and interpersonal and communication skills. The 2021 IC Milestones 2.0 provides a framework for IC mentors and trainees to identify areas for improvement or commendation help stimulate meaningful educational discussions, and provide the basis for self-reflection and self-improvement.


Assuntos
Cardiologia , Internato e Residência , Acreditação , Competência Clínica , Educação de Pós-Graduação em Medicina , Humanos , Resultado do Tratamento , Estados Unidos
3.
Curr Cardiol Rep ; 24(10): 1287-1297, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36152141

RESUMO

PURPOSE OF REVIEW: Paravalvular leak (PVL) is a relatively uncommon complication associated with prosthetic valve implantation. PVL can occasionally lead to serious adverse consequences such as congestive heart failure, infective endocarditis, and hemolytic anemia. Surgical re-operation carries a high mortality risk. RECENT FINDINGS: Transcatheter closure therapy provides a viable alternative for the treatment of this disorder with reasonable procedural and clinical success. The recent advent of hybrid imaging modalities has increased procedural success. This article summarizes the pathophysiology, clinical characteristics, and treatment modalities surroundings prosthetic paravalvular leak.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Cateterismo Cardíaco/métodos , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Falha de Prótese , Reoperação/efeitos adversos , Resultado do Tratamento
4.
Catheter Cardiovasc Interv ; 97(5): E680-E685, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-32845073

RESUMO

Interventions on graft bifurcation lesions are uncommon, especially in the setting of acute coronary syndromes (ACS). We described three cases of graft bifurcation intervention where we tailored our approach based on lesion characteristics, anatomy, and angulation to achieve excellent angiographic and clinical outcomes. In case 1, shared ostia of saphenous vein graft (SVG) to Diagonal (D) and Radial graft to Obtuse Marginal (OM) was severely stenosed. We prioritized the radial arterial graft as it is known to have a longer patency rate over a totally occluded SVG of an undetermined period. We performed provisional stenting of the ostium of the radial artery and balloon angioplasty of the SVG ostium, while stenting the body of the SVG. In case 2 (bifurcation lesion at the anastomosis of SVG to D1 and sequential jump graft to OM), we utilized a V stenting strategy after an embolization protection device (EPD) was deployed in the branch with a suitable landing zone. Kissing balloon dilatation of both the branches was performed both pre- and poststenting. In case 3 (bifurcation lesion at SVG to OM and Sequential "T" graft to diagonal), there was >90% angulation between both the grafts. We used "T" stenting strategy in this case. At 2-year follow-up, patients had no major adverse cardiovascular events since and remained symptom free.


Assuntos
Síndrome Coronariana Aguda , Intervenção Coronária Percutânea , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/etiologia , Síndrome Coronariana Aguda/cirurgia , Angiografia Coronária , Ponte de Artéria Coronária , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/cirurgia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Veia Safena/diagnóstico por imagem , Resultado do Tratamento
5.
Catheter Cardiovasc Interv ; 95(4): 840-848, 2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-31515964

RESUMO

INTRODUCTION: Transcatheter mitral valve replacement (TMVR) is an option for patients at high risk for mitral valve replacement or repair via sternotomy or left thoracotomy approach. TMVR carries up to 22% risk of left ventricular outflow tract (LVOT) obstruction. Severe LVOT obstruction can have devastating hemodynamic and clinical consequences. HYPOTHESIS: We previously presented a novel technique to prevent LVOT obstruction during transapical retrograde mitral valve replacement, by penetrating and ballooning the anterior mitral leaflet (AML), resulting in creation of a "hole" and posterior translocation of AML, then deploying the valve. METHODS: Three patients underwent TMVR at Saint Louis University for severe mitral regurgitation after being deemed too high risk for surgery, and not candidates for a Mitra-clip procedure. These patients were deemed to be at risk for LVOT obstruction based on the preprocedural evaluation. Via transapical approach, a needle was advanced "through," perforating the AML and wire was placed in the left atrium. Over the wire, an 20-mm valvuloplasty balloon was positioned "within" the anterior leaflet and inflated leading to translocation of the AMVL. Then the valve was deployed. RESULTS: This novel technique has been performed on three patients at our institution. Sapien S3 transcatheter valves were used in all three patients, with 100% procedural success rate. Intraoperative TEE demonstrated no significant LVOT obstruction, cardiopulmonary bypass time was 42-44 min. CONCLUSION: The balloon assisted translocation of the mitral anterior leaflet to prevent left ventricular outflow obstruction technique described here may offer the option of transcatheter mitral valve implantation in patients at high risk of LVOT obstruction. A variation of this technique to allow application in cases with transseptal approach is under investigation.


Assuntos
Valvuloplastia com Balão , Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Obstrução do Fluxo Ventricular Externo/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Desenho de Prótese , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/fisiopatologia
6.
Mo Med ; 117(1): 70-72, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32158054

RESUMO

Spontaneous coronary artery dissection (SCAD) is an uncommon and potentially fatal cause of acute coronary syndrome, myocardial infarction, and sudden death primarily affecting women. While the exact cause of SCAD is unknown, associated risk factors are emotional or physical stress, female gender, pregnancy-related factors including hormonal changes, fibromuscular dysplasia, mixed connective tissue disorders, and inflammatory disorders. In this report, we present a middle-aged female with ulcerative colitis and cirrhosis secondary to primary sclerosing cholangitis who was found to have SCAD on cardiac evaluation for liver transplantation workup.


Assuntos
Anomalias dos Vasos Coronários/diagnóstico por imagem , Anomalias dos Vasos Coronários/cirurgia , Transplante de Fígado , Doenças Vasculares/congênito , Angiografia Coronária , Feminino , Humanos , Pessoa de Meia-Idade , Fatores de Risco , Doenças Vasculares/diagnóstico por imagem , Doenças Vasculares/cirurgia
10.
Catheter Cardiovasc Interv ; 87(4): 735-41, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26616458

RESUMO

Treatment of aorto-ostial in-stent restenosis lesions represents a challenge for interventional cardiologists. Excessive protrusion of the stent into the aorta may lead to multiple technical problems, such as difficult catheter reengagement of the vessel ostium or inability to re-wire through the stent lumen in repeat interventions. We describe a balloon assisted access to protruding stent technique in cases where conventional coaxial engagement of an aorto-ostial protruding stent with the guide catheter or passage of the guide wire through the true lumen is not feasible. This technique is applicable both in coronary and peripheral arteries.


Assuntos
Angioplastia com Balão , Aorta , Doença da Artéria Coronariana/terapia , Reestenose Coronária/terapia , Vasos Coronários , Intervenção Coronária Percutânea/instrumentação , Stents , Idoso , Aorta/diagnóstico por imagem , Aortografia , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Reestenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Resultado do Tratamento
11.
Catheter Cardiovasc Interv ; 87(2): 273-82, 2016 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-26424295

RESUMO

OBJECTIVES AND BACKGROUND: Functional assessment of intermediate coronary stenosis during cardiac catheterization is conducted using diagnostic parameters like fractional flow reserve (FFR), coronary flow reserve (CFR), hyperemic stenosis resistance index (HSR), and hyperemic microvascular resistance (HMR). CDP (ratio of pressure drop across a stenosis to distal dynamic pressure), a nondimensional index derived from fundamental fluid dynamic principles, based on a combination of intracoronary pressure, and flow measurements may improve the functional assessment of coronary lesion severity. METHODS: Patient-level data pertaining to 350 intracoronary pressure and flow measurements across coronary stenoses was assessed to evaluate CFR, FFR, HSR, HMR, and CDP. CDP was calculated as (ΔP)/(0.5 × ρ × APV(2)). The density of blood (ρ) was assumed to be 1.05 g/cm(3). The correlation of current diagnostic parameters (CFR, FFR, HSR, and HMR) with CDP was evaluated. The receiver operating characteristic (ROC) curve was used to identify the optimal cut-off point of CDP, corresponding to the clinically used cut-off values (FFR = 0.80 and CFR = 2.0). RESULTS: CDP correlated significantly with FFR (r = 0.81, P < 0.05) and had significant diagnostic efficiency (ROC-area under curve of 86%), specificity (72%) and sensitivity (85%) at FFR < 0.8. The corresponding cut-off value for CDP to detect FFR < 0.8 was at CDP>25.4. CDP also correlated significantly (r = 0.98, P < 0.05) with epicardial-specific parameter, HSR. CONCLUSIONS: CDP, a functional parameter based on both intracoronary pressure and flow measurements, has close agreement (area under ROC curve = 86%) with FFR, the frequently used method of evaluating stenosis severity.


Assuntos
Pressão Arterial , Cateterismo Cardíaco , Estenose Coronária/diagnóstico , Vasos Coronários/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico , Idoso , Área Sob a Curva , Angiografia Coronária , Estenose Coronária/fisiopatologia , Vasos Coronários/diagnóstico por imagem , Feminino , Humanos , Hiperemia/fisiopatologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Curva ROC , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
12.
Catheter Cardiovasc Interv ; 86(3): 364-75, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25914388

RESUMO

BACKGROUND: Diabetes patients undergoing percutaneous coronary intervention (PCI) have more complications than nondiabetes patients, including increased long-term mortality. Use of bivalirudin versus heparin and glycoprotein IIb/IIIa inhibitors (GPI) in diabetes patients undergoing PCI and its effect on long-term mortality were evaluated in few randomized trials, but with conflicting results. METHODS: We searched the literature for randomized controlled trials that compared heparin and GPI therapy with bivalirudin in diabetes patients undergoing PCI. The incidence of major adverse cardiovascular events (MACE), death from any cause, myocardial infarction (MI), urgent revascularization, major and minor bleeding (at 30 days), as well as all-cause mortality at 1 year were included, and meta-analysis was performed. RESULTS: A total of 5,137 patients with diabetes were included in four randomized trials. At 30 days, bivalirudin, compared with heparin and GPI, caused less major bleeding (odds ratio (OR), 0.68; 95% confidence interval (CI), 0.52-0.89; P = 0.005) and less minor bleeding (OR, 0.48; 95% CI, 0.41-0.57; P < 0.00001) and similar rates of MACE (OR, 0.87; 95% CI, 0.70-1.08; P = 0.21), MI (OR, 0.87; 95% CI, 0.68-1.10; P = 0.25), and urgent revascularization (OR, 1.12; 95% CI, 0.76-1.65; P = 0.57). Death from any cause at 30 day was numerically lower with bivalirudin use but not statistically significant (OR, 0.72; 95% CI, 0.46-1.13; P = 0.15). Mortality at 1 year was significantly lower in diabetes patients treated with bivalirudin compared with heparin and GPI (OR, 0.72; 95% CI, 0.52-0.99; P = 0.04). A secondary analysis suggests that the major bleeding benefit with bivalirudin may be driven by mandated use of GPI in heparin arm. CONCLUSION: Among patients with diabetes undergoing PCI, bivalirudin caused less major and minor bleeding compared with heparin and GPI, with similar rates of MACE, death, MI, and urgent revascularization at 30 days, but significantly lower mortality rates at 1 year.


Assuntos
Anticoagulantes/uso terapêutico , Antitrombinas/uso terapêutico , Doença das Coronárias/terapia , Complicações do Diabetes , Heparina/uso terapêutico , Fragmentos de Peptídeos/uso terapêutico , Intervenção Coronária Percutânea/métodos , Complexo Glicoproteico GPIIb-IIIa de Plaquetas/antagonistas & inibidores , Quimioterapia Combinada , Hirudinas , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto , Proteínas Recombinantes/uso terapêutico , Resultado do Tratamento
13.
Catheter Cardiovasc Interv ; 83(3): 377-85, 2014 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-23785016

RESUMO

OBJECTIVES AND BACKGROUND: Myocardial fractional flow reserve (FFR) in conjunction with coronary flow reserve (CFR) is used to evaluate the hemodynamic severity of coronary lesions. However, discordant results between FFR and CFR have been observed in intermediate coronary lesions. A functional parameter, pressure drop coefficient (CDP; ratio of pressure drop to distal dynamic pressure), was assessed using intracoronary pressure drop (dp) and average peak velocity (APV). The CDP is a nondimensional ratio, derived from fundamental fluid dynamic principles. We sought to evaluate the correlation of CDP with FFR, CFR, and hyperemic stenosis resistance (HSR: ratio of pressure drop to APV) in human subjects. METHODS: Twenty-seven patients with reversible perfusion defects based on SPECT were consented for the study before cardiac catheterization. Distal coronary pressure and APV were measured simultaneously for each coronary lesion using a Combowire(©) during cardiac catheterization. Reference diameter, minimal lumen diameter, and %AS were obtained by quantitative coronary angiography. Maximum hyperemia was induced by IV adenosine (140 µg/kg/min). CDP was calculated as, (Δp)/(0.5 × ρ × APV(2) ). The density of blood (ρ) was assumed to be 1.05 gm/cm(3) . RESULTS: The functional index, CDP, when correlated simultaneously with FFR and CFR, was found to have a significant correlation (r = 0.61; P < 0.05). Similarly a significant correlation was achieved when CDP was correlated with HSR (r = 0.91; P < 0.001). This is consistent with the definition of CDP, which is a functional parameter that includes both pressure and flow information. CONCLUSIONS: CDP, a nondimensional parameter combining simultaneous measurements of pressure drop and velocity data, can accurately define the severity of coronary stenoses and could prove advantageous clinically.


Assuntos
Pressão Arterial , Cateterismo Cardíaco , Estenose Coronária/diagnóstico , Vasos Coronários/fisiopatologia , Adenosina/administração & dosagem , Administração Intravenosa , Velocidade do Fluxo Sanguíneo , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Angiografia Coronária , Circulação Coronária , Estenose Coronária/fisiopatologia , Desenho de Equipamento , Feminino , Humanos , Hiperemia/fisiopatologia , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Ohio , Projetos Piloto , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Vasodilatadores/administração & dosagem
14.
J Thromb Thrombolysis ; 38(2): 260-8, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24590502

RESUMO

Severe mitral valve regurgitation is a serious condition with significant morbidity and mortality. It is not uncommon recently, to see patients with significant mitral valve regurgitation that are considered "non-surgical candidates" due to their comorbidities. MitraClip is a new percutaneous approach for treating mitral valve regurgitation which involves mechanical edge-to-edge coaptation of the mitral leaflets. In October of 2013, The US Food and Drug Administration (FDA) approved the MitraClip for patients with symptomatic degenerative mitral regurgitation deemed high risk for mitral-valve surgery. Several large clinical trials confirmed the safety and efficacy of MitraClip. We here discuss the growing role of MitraClip, the major clinical trials, the ongoing trials and the potential complications of the procedure.


Assuntos
Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral/patologia , Insuficiência da Valva Mitral/cirurgia , Humanos , Estados Unidos , United States Food and Drug Administration
15.
Heart Vessels ; 29(1): 97-109, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23624760

RESUMO

In this study, coronary diagnostic parameters, pressure drop coefficient (CDP: ratio of trans-stenotic pressure drop to distal dynamic pressure), and lesion flow coefficient (LFC: ratio of % area stenosis (%AS) to the CDP at throat region), were evaluated to distinguish levels of %AS under varying contractility conditions, in the presence of microvascular disease (MVD). In 10 pigs, %AS and MVD were created using angioplasty balloons and 90-µm microspheres, respectively. Simultaneous measurements of pressure drop, left ventricular pressure (p), and velocity were obtained. Contractility was calculated as (dp/dt)max, categorized into low contractility <900 mmHg/s and high contractility >900 mmHg/s, and in each group, compared between %AS <50 and >50 using analysis of variance. In the presence of MVD, between the %AS <50 and >50 groups, values of CDP (71 ± 1.4 and 121 ± 1.3) and LFC (0.10 ± 0.04 and 0.19 ± 0.04) were significantly different (P < 0.05), under low-contractility conditions. A similar %AS trend was observed under high-contractility conditions (CDP: 18 ± 1.4 and 91 ± 1.4; LFC: 0.08 ± 0.04 and 0.25 ± 0.04). Under MVD conditions, similar to fractional flow reserve, CDP and LFC were not influenced by contractility.


Assuntos
Doença da Artéria Coronariana/fisiopatologia , Estenose Coronária/fisiopatologia , Vasos Coronários/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico , Hemodinâmica , Microcirculação , Contração Miocárdica , Função Ventricular Esquerda , Animais , Velocidade do Fluxo Sanguíneo , Doença da Artéria Coronariana/diagnóstico , Estenose Coronária/diagnóstico , Modelos Animais de Doenças , Índice de Gravidade de Doença , Suínos , Pressão Ventricular
16.
Methodist Debakey Cardiovasc J ; 20(1): 33-39, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38855039

RESUMO

We report three cases of coronary artery aneurysm (CAA) in adults who presented with acute coronary syndrome. Two of these patients did not have traditional coronary artery disease risk factors. Management of CAA poses a significant challenge to interventionalists. We discuss the etiologic mechanisms, risk factors, pathophysiology, and diagnosis using angiography, intravascular ultrasound, and coronary computed tomography. We also highlight management options, including medical therapy and catheter-based interventions such as stenting, coil embolization, stent-assisted coil embolization, and surgical exclusion.


Assuntos
Síndrome Coronariana Aguda , Aneurisma Coronário , Angiografia Coronária , Humanos , Aneurisma Coronário/diagnóstico por imagem , Aneurisma Coronário/terapia , Síndrome Coronariana Aguda/terapia , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/etiologia , Masculino , Resultado do Tratamento , Pessoa de Meia-Idade , Embolização Terapêutica , Ultrassonografia de Intervenção , Feminino , Idoso , Valor Preditivo dos Testes , Stents , Intervenção Coronária Percutânea/instrumentação , Angiografia por Tomografia Computadorizada , Fatores de Risco
17.
Am J Cardiol ; 2024 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-39089524

RESUMO

Transcatheter aortic valve replacement (TAVR) continues to grow in the United States. There are limited data on recipients of solid organ transplant (SOT) and patients with liver cirrhosis who undergo aortic valve replacement (AVR). Our study aims to evaluate outcomes in these populations. Using the national readmission database (2016 to 2020), we identified recipients of SOT and patients with liver cirrhosis without previous liver transplants who were admitted for severe aortic stenosis and underwent either TAVR or surgical AVR (SAVR). We used multivariable regression for adjusted analysis and the propensity score matching model, implementing complete Mahalanobis distance matching within the Propensity Score Caliper (0.2) to match TAVR and SAVR cohorts for outcomes. Of 3,394 hospitalizations for AVR in recipients of SOT, 2,181 underwent TAVR, and 1,213 underwent SAVR. On propensity-matched analysis, SAVR was associated with more adverse events than was TAVR, including in-hospital mortality (5.2% vs 1.1%, adjusted odds ratio [aOR] 4.49, p <0.001), acute kidney injury (43.7% vs 10.2%, p <0.001), cardiogenic shock (9.0% vs 1.6%, p <0.001), sudden cardiac arrest (15.9 vs 6.0%, p <0.001), major adverse cardiac and cerebrovascular events (28% vs 10.4%, p <0.001), and net adverse events (72.8 vs 37.6%, p <0.001). A greater median length of stay (10 vs 2 days, p <0.001) and adjusted cost ($80,842 vs $57,014, p <0.001) were also observed. The readmission rates were the same for both cohorts after a 6-month follow-up. Similarly, in 14,763 hospitalizations for AVR in liver cirrhosis, 7,109 patients underwent TAVR, and 7,654 underwent SAVR. In propensity-matched cohorts (n = 2,341), SAVR was found to be associated with greater adverse events, including in-hospital mortality (19.8% vs 10%, aOR 5.52), stroke (6.7% vs 2%), acute kidney injury (67.7% vs 30.3%), cardiogenic shock (41.9% vs 19.9%), sudden cardiac arrest (31.8% vs 13.2%, aOR 2.89), major adverse cardiac and cerebrovascular events (66.2% vs 35.7%), and net adverse events (86% vs 59.5%) (p <0.001). A greater median length of stay (16 vs 3 days) and cost ($500,218 vs $263,383) were also observed (p <0.001). However, the rate of readmissions at 30-day (9% vs 11.1%) and 180-day intervals (33.4% vs 39.8%) was lower for the SAVR cohort (p <0.05). In recipients of SOT and patients with liver cirrhosis, SAVR is associated with greater short-term mortality, adverse events, and healthcare burden than is TAVR. TAVR is a relatively safer alternative to SAVR in these patient populations, although further studies are warranted to compare the long-term outcomes.

18.
medRxiv ; 2024 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-38947006

RESUMO

Heart disease is the leading cause of death worldwide, and cardiac function as measured by ejection fraction (EF) is an important determinant of outcomes, making accurate measurement a critical parameter in PT evaluation. Echocardiograms are commonly used for measuring EF, but human interpretation has limitations in terms of intra- and inter-observer (or reader) variance. Deep learning (DL) has driven a resurgence in machine learning, leading to advancements in medical applications. We introduce the ViViEchoformer DL approach, which uses a video vision transformer to directly regress the left ventricular function (LVEF) from echocardiogram videos. The study used a dataset of 10,030 apical-4-chamber echocardiography videos from patients at Stanford University Hospital. The model accurately captures spatial information and preserves inter-frame relationships by extracting spatiotemporal tokens from video input, allowing for accurate, fully automatic EF predictions that aid human assessment and analysis. The ViViEchoformer's prediction of ejection fraction has a mean absolute error of 6.14%, a root mean squared error of 8.4%, a mean squared log error of 0.04, and an R 2 of 0.55. ViViEchoformer predicted heart failure with reduced ejection fraction (HFrEF) with an area under the curve of 0.83 and a classification accuracy of 87 using a standard threshold of less than 50% ejection fraction. Our video-based method provides precise left ventricular function quantification, offering a reliable alternative to human evaluation and establishing a fundamental basis for echocardiogram interpretation.

19.
J Soc Cardiovasc Angiogr Interv ; 3(7): 101980, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39131996

RESUMO

The field of interventional cardiology (IC) has evolved dramatically over the past 40 years. Training and certification in IC have kept pace, with the development of accredited IC fellowship training programs, training statements, and subspecialty board certification. The application process, however, remained fragmented with lack of a universal process or time frame. In recent years, growing competition among training programs for the strongest candidates resulted in time-limited offers and high-pressure situations that disadvantaged candidates. A grassroots effort was recently undertaken by a Society for Cardiovascular Angiography & Interventions task force, to create equity in the system by establishing a national Match for IC fellowship. This manuscript explores the rationale, process, and implications of this endeavor.

20.
Aorta (Stamford) ; 11(1): 47-49, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36848913

RESUMO

Acute aortic dissection is one of the most lethal diseases, affecting the lining of the aortic wall. We describe a case of Stanford Type A aortic dissection in a patient with underlying primary antiphospholipid syndrome (APS) complicated by coronavirus disease 2019 (COVID-19). APS is characterized by recurrent venous and/or arterial thrombosis, thrombocytopenia, and rarely vascular aneurysms. The hypercoagulable milieu attributable to APS and the prothrombotic state from COVID-19 posed a challenge in achieving optimal postoperative anticoagulation in our patient.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA