Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Chemosphere ; 70(7): 1309-19, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17767945

RESUMO

It is a great challenge to sample seawater across interfaces, for example the halocline or the redoxcline, to investigate trace metal distribution. With the use of 10l sampling bottles mounted to a wire or a CTD-Rosette it is possible to obtain a maximum vertical resolution of 5m. For the detection of small vertical structures in the vertical distribution of trace metals across the redoxcline, the CTD-Bottle-Rosette is not sufficient. Therefore, a PUMP-CTD-System was developed, which enables water sampling with high resolution (1m maximum) along a vertical profile. To investigate the suitability and possible contamination sources of this device two experiments were carried out in the Gotland Basin. The first experiment consisted of two separate profiles. The first profile was obtained with the CTD-Bottle-Rosette and the second with the PUMP-CTD-System. Both were taken from the bottom to the surface water layer. The second experiment was a combined profile obtained from the surface to the bottom with the PUMP-CTD-System attached to the CTD-Bottle-Rosette. Concentrations of dissolved Pb, Cd, Cu, Zn, Fe, Mn, Co and Ni from the "Niskin Bottles" and from the PUMP were measured and compared for each investigation. We demonstrate that it is useful to perform vertical sampling from lower to higher concentrations, e.g. surface to bottom in this environment, and that a longer flushing is required for sampling seawater in the anoxic bottom water. A comparison of the two systems for oxygen and hydrogen sulphide measurements showed an improvement of the precision and the quality of the sampling when using the PUMP. Thus, metal speciation at the oxic-anoxic gradient zone and on a high vertical resolution will be accessible. As concentrations of dissolved Pb, Cd, Cu, Zn, Co, Ni, Fe and Mn in seawater sampled with both devices were in the same range, we conclude that the PUMP-CTD-System is well suited to sample seawater for trace metal analyses.


Assuntos
Água do Mar/análise , Oligoelementos/análise , Poluentes Químicos da Água/análise , Monitoramento Ambiental/instrumentação , Monitoramento Ambiental/métodos , Oceanos e Mares , Purificação da Água/instrumentação , Purificação da Água/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA