Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Cardiol Young ; 30(11): 1730-1731, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33203499

RESUMO

Anomalous circumflex coronary artery origin from pulmonary artery is a very rare congenital heart disease. Misdiagnosis of this condition may lead to inadequate myocardial protection during cardiopulmonary bypass surgery.


Assuntos
Doença da Artéria Coronariana , Anomalias dos Vasos Coronários , Angiografia Coronária , Anomalias dos Vasos Coronários/diagnóstico por imagem , Anomalias dos Vasos Coronários/cirurgia , Humanos , Artéria Pulmonar/diagnóstico por imagem
2.
Pediatr Crit Care Med ; 20(8): 728-736, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30985609

RESUMO

OBJECTIVES: To assess the variation in timing of left atrial decompression and its association with clinical outcomes in pediatric patients supported with venoarterial extracorporeal membrane oxygenation across a multicenter cohort. DESIGN: Multicenter retrospective study. SETTING: Eleven pediatric hospitals within the United States. PATIENTS: Patients less than 18 years on venoarterial extracorporeal membrane oxygenation who underwent left atrial decompression from 2004 to 2016. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: A total of 137 patients (median age, 4.7 yr) were included. Cardiomyopathy was the most common diagnosis (47%). Cardiac arrest (39%) and low cardiac output (50%) were the most common extracorporeal membrane oxygenation indications. Median time to left atrial decompression was 6.2 hours (interquartile range, 3.8-17.2 hr) with the optimal cut-point of greater than or equal to 18 hours for late decompression determined by receiver operating characteristic curve. In univariate analysis, late decompression was associated with longer extracorporeal membrane oxygenation duration (median 8.5 vs 5 d; p = 0.02). In multivariable analysis taking into account clinical confounder and center effects, late decompression remained significantly associated with prolonged extracorporeal membrane oxygenation duration (adjusted odds ratio, 4.4; p = 0.002). Late decompression was also associated with longer duration of mechanical ventilation (adjusted odds ratio, 4.8; p = 0.002). Timing of decompression was not associated with in-hospital survival (p = 0.36) or overall survival (p = 0.42) with median follow-up of 3.2 years. CONCLUSIONS: In this multicenter study of pediatric patients receiving venoarterial extracorporeal membrane oxygenation, late left atrial decompression (≥ 18 hr) was associated with longer duration of extracorporeal membrane oxygenation support and mechanical ventilation. Although no survival benefit was demonstrated, the known morbidities associated with prolonged extracorporeal membrane oxygenation use may justify a recommendation for early left atrial decompression.


Assuntos
Descompressão Cirúrgica/métodos , Oxigenação por Membrana Extracorpórea/métodos , Átrios do Coração/cirurgia , Criança , Pré-Escolar , Descompressão Cirúrgica/mortalidade , Oxigenação por Membrana Extracorpórea/mortalidade , Feminino , Humanos , Lactente , Unidades de Terapia Intensiva Pediátrica/estatística & dados numéricos , Tempo de Internação/estatística & dados numéricos , Masculino , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo
3.
Pediatr Cardiol ; 40(7): 1523-1529, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31375852

RESUMO

Acute femoral artery occlusion is common in pediatric patients following cardiac catheterization. A variety of means are utilized to assess lower extremity (LE) perfusion and arterial patency following cardiac catheterization including palpation of pulses, pulse oximetry, subjective assessment of lower extremity color and temperature, and ultrasound. We sought to evaluate the utility of Near-Infrared Spectroscopy (NIRS) to monitor LE perfusion in pediatric patients undergoing cardiac catheterization. INVOS pediatric sensors were placed on bilateral LE in all pediatric patients ≤ 40 kg undergoing cardiac catheterization. Data were recorded continuously from the start of the procedure until 4-6 h after completion of the procedure. NIRS readings were compared between the accessed versus non-accessed LE at baseline before start of case, time of vascular access, arterial sheath exchange when applicable, sheath withdrawal, and Safeguard application, deflation, and removal. 133 patients underwent 152 catheterizations with mean age 2.4 ± 2.3 years and mean weight 12.4 ± 13.2 kg. NIRS oximetry readings were significantly decreased in the LE with arterial access compared to non-accessed LE from time of sheath insertion until removal of the pressure assist device post procedure. A greater difference was noted in smaller patients. NIRS oximetry readings did not correlate with subjective assessment of lower extremity perfusion after arterial sheaths were removed. One patient had pulse loss 4 h post procedure with a decrease in oximetry readings noted at this point on review. Weight-based heparin protocol was initiated, and a gradual improvement in oximetry readings was noted over the next 5 h. Vascular ultrasound 12 h later showed no evidence of arterial thrombus. NIRS may be helpful in identifying patients who are risk for developing arterial thrombus post cardiac catheterization and for monitoring response to therapy; however, further study in these patients is warranted.


Assuntos
Cateterismo Cardíaco/efeitos adversos , Extremidade Inferior/irrigação sanguínea , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Arteriopatias Oclusivas/diagnóstico , Encéfalo/irrigação sanguínea , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Oximetria/métodos , Trombose/etiologia , Trombose/prevenção & controle , Ultrassonografia Doppler
4.
Catheter Cardiovasc Interv ; 88(6): 902-911, 2016 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-27471092

RESUMO

BACKGROUND: Metallic endovascular stents are utilized off-label in congenital heart disease. Biodegradable stents (BDS) offer potential advantages in a growing child. We have previously reported double opposed helical (DH) BDS up to 6 mm diameter (DH-6). The objectives are to investigate the bench characteristics of larger 8 mm diameter BDS (DH-8) manufactured with increasing strut thicknesses and the inflammatory profile in a porcine model. METHODS: DH-8 were manufactured with strut thicknesses 0.10, 0.12, and 0.18 mm and mechanical testing performed. Stents were deployed into the infrarenal descending aorta (DAO) of nine minipigs. At insertion (nonsurvival = 2), 1 week (n = 2), 1 month (n = 2), and 9 months (n = 3) follow-up angiography, intravascular ultrasound and histopathology were performed. RESULTS: There was superior recoil and collapse pressure with increasing strut thickness, with 0.18 mm having 1.0% elastic recoil and collapse pressure 0.75 Atmospheres. There was good wall apposition at insertion with 5 BDS (4 DH-8 and 1 DH-6) but suboptimal in 4 as the minipigs infrarenal DAO were >8 mm (deployed at iliac bifurcation). Structural integrity was maintained in 8 BDS with 1 DH-8 collapsed at 9 months, secondary to strut damage at insertion. No thrombosis was seen. There was mild inflammation and neointimal proliferation at 1 week and 1 month, but a moderate inflammatory response at 9 months. CONCLUSIONS: DH-8 with increased strut thickness had acceptable mechanical properties at the cost of an increased inflammatory response. Miniaturization to improve delivery and further investigation on the long-term inflammatory profile of thicker struts, including through degradation, is needed. © 2016 Wiley Periodicals, Inc.


Assuntos
Aorta Abdominal/cirurgia , Doenças da Aorta/cirurgia , Stents Farmacológicos , Procedimentos Endovasculares/métodos , Angiografia , Animais , Aorta Abdominal/diagnóstico por imagem , Doenças da Aorta/diagnóstico , Modelos Animais de Doenças , Feminino , Seguimentos , Desenho de Prótese , Suínos , Porco Miniatura , Tomografia de Coerência Óptica , Ultrassonografia de Intervenção
5.
Cardiol Young ; 26(7): 1441-4, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27322920

RESUMO

Pulmonary sequestration is a rare congenital anomaly that can be asymptomatic or present with recurrent infections, respiratory symptoms, or rarely heart failure. Sequestration is classified as intralobar or extralobar on the basis of whether there is separation from normal lung tissue by its own visceral pleura. Classically, patients are treated with surgical resection. We present a case of multivessel, combined intralobar and extralobar pulmonary sequestration treated with transcatheter embolisation.


Assuntos
Sequestro Broncopulmonar/diagnóstico por imagem , Sequestro Broncopulmonar/cirurgia , Cateterismo Cardíaco/métodos , Embolização Terapêutica/métodos , Dispositivo para Oclusão Septal , Pré-Escolar , Angiografia por Tomografia Computadorizada , Ecocardiografia , Feminino , Humanos
6.
Cardiol Young ; 26(8): 1568-1572, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28148330

RESUMO

Recently, three-dimensional printing of heart models is being used to plan percutaneous and surgical interventions in patients with CHD. We describe a case where we used a three-dimensional print model to plan a complex percutaneous intervention in a patient with coarctation of the aorta.


Assuntos
Angioplastia com Balão/métodos , Aorta Torácica/diagnóstico por imagem , Coartação Aórtica/diagnóstico por imagem , Coartação Aórtica/terapia , Impressão Tridimensional/estatística & dados numéricos , Angiografia por Tomografia Computadorizada , Humanos , Masculino , Modelos Cardiovasculares , Adulto Jovem
7.
World J Pediatr Congenit Heart Surg ; 12(1): 17-26, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33407028

RESUMO

BACKGROUND: To assess changes in patterns of practice and outcomes over time, we reviewed all patients who underwent heart transplantation (HTx) at our institution and compared two consecutive eras with significantly different immunosuppressive protocols (cohort 1 [80 HTx, June 1995-June 2006]; cohort 2 [108 HTx, July 2006-September 2018]). METHODS: Retrospective study of 180 patients undergoing 188 HTx (June 1995-September 2018; 176 first time HTx, 10 second HTx, and 2 third HTx). In 2006, we commenced pre-HTx desensitization for highly sensitized patients and started using tacrolimus as our primary postoperative immunosuppressive agent. The primary outcome was mortality. Survival was modeled by the Kaplan-Meier method. Univariable and multivariable Cox proportional hazard models were created to identify prognostic factors for survival. RESULTS: Our 188 HTx included 18 neonates, 85 infants, 83 children, and 2 adults (>18 years). Median age was 260.0 days (range: 5 days-23.8 years). Median weight was 7.5 kg (range: 2.2-113 kg). Patients in cohort 1 were less likely to have been immunosensitized preoperatively (12.5% vs 28.7%, P = .017). Nevertheless, Kaplan-Meier analysis suggested superior survival in cohort 2 (P = .0045). Patients in cohort 2 were more likely to be alive one year, five years, and ten years after HTx. Multivariable analysis identified the earlier era (hazard ratio [HR] [95% confidence interval] for recent era = 0.32 [0.14-0.73]), transplantation after prior Norwood operation (HR = 4.44 [1.46-13.46]), and number of prior cardiac operations (HR = 1.33 [1.03-1.71]) as risk factors for mortality. CONCLUSIONS: Our analysis of 23 years of pediatric and congenital HTx reveals superior survival in the most recent 12-year era, despite the higher proportion of patients with elevated panel reactive antibody in the most recent era. This improvement was temporally associated with changes in our immunosuppressive strategy.


Assuntos
Cardiopatias Congênitas/cirurgia , Transplante de Coração/métodos , Procedimentos de Norwood/métodos , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA