Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Sensors (Basel) ; 23(16)2023 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-37631777

RESUMO

A ratiometric fiber optic temperature sensor based on a highly coupled seven-core fiber (SCF) is proposed and experimentally demonstrated. A theoretical analysis of the SCF's sinusoidal spectral response in transmission configuration is presented. The proposed sensor comprises two SCF devices exhibiting anti-phase transmission spectra. Simple fabrication of the devices is shown by just splicing a segment of a 2 cm long SCF between two single-mode fibers (SMFs). The sensor proved to be robust against light source fluctuations, as a standard deviation of 0.2% was registered in the ratiometric measurements when the light source varied by 12%. Its low-cost detection system (two photodetectors) and the range of temperature detection (25 °C to 400 °C) make it a very attractive and promising device for real industrial applications.

2.
Sensors (Basel) ; 23(1)2023 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-36617081

RESUMO

In this paper, a ratiometric approach to sensing temperature variations is shown using specialty fiber optic devices. We analyzed the transmission response of cascaded segments of multicore fibers (MCFs), and dissimilar lengths were found to generate an adequate scheme for ratiometric operation. The perturbation of optical parameters in the MCFs translates to a rich spectral behavior in which some peaks increase their intensity while others decrease their intensity. Thus, by selecting opposite-behavior peaks, highly sensitive ratiometric measurements that provide robustness against spurious fluctuations can be performed. We implemented this approach using seven-core fiber (SCF) segments of 5.8 cm and 9.9 cm. To test the system's response under controlled perturbations, we heated one of the segments from ambient temperature up to 150 °C. We observed defined peaks with opposite behavior as a function of temperature. Two pairs of peaks within the interrogation window were selected to perform ratiometric calculations. Ratiometric measurements exhibited sensitivities 6-14 times higher than single-wavelength measurements. A similar trend with enhanced sensitivity in both peak pairs was obtained. In contrast to conventional interferometric schemes, the proposed approach does not require expensive facilities or micrometric-resolution equipment. Moreover, our approach has the potential to be realized using commercial splicers, detectors, and filters.

3.
Sensors (Basel) ; 21(16)2021 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-34450913

RESUMO

In this paper, we propose a highly sensitive temperature sensor based on two cascaded Mach-Zehnder interferometers (MZIs) that work using the Vernier effect. The all-fiber MZIs were assembled by splicing a segment of capillary hollow-core fiber (CHCF) between two sections of multimode fibers (MMFs). This cascaded configuration exhibits a temperature sensitivity of 1.964 nm/°C in a range from 10 to 70 °C, which is ~67.03 times higher than the sensitivity of the single MZI. Moreover, this device exhibits a high-temperature resolution of 0.0153 °C. A numerical analysis was carried out to estimate the devices' temperature sensitivity and calculate the magnification of the sensitivity produced by the Vernier effect. The numerical results have an excellent agreement with the experimental results and provide a better insight into the working principle of the MZI devices. The sensor's performance, small size, and easy fabrication make us believe that it is an attractive candidate for temperature measurement in biological applications.


Assuntos
Interferometria , Refratometria , Temperatura Alta , Temperatura
4.
Sensors (Basel) ; 20(13)2020 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-32635602

RESUMO

In this paper, we propose and experimentally demonstrate a simple technique to enhance the curvature sensitivity of a bending fiber optic sensor based on anti-resonant reflecting optical waveguide (ARROW) guidance. The sensing structure is assembled by splicing a segment of capillary hollow-core fiber (CHCF) between two single-mode fibers (SMF), and the device is set on a steel sheet for measuring different curvatures. Without any surface treatment, the ARROW sensor exhibits a curvature sensitivity of 1.6 dB/m-1 in a curvature range from 0 to 2.14 m-1. By carefully coating half of the CHCF length with polydimethylsiloxane (PDMS), the curvature sensitivity of the ARROW sensor is enhanced to -5.62 dB/m-1, as well as an increment in the curvature range (from 0 to 2.68 m-1). Moreover, the covered device exhibits a low-temperature sensitivity (0.038 dB/°C), meaning that temperature fluctuations do not compromise the bending fiber optic sensor operation. The ARROW sensor fabricated with this technique has high sensitivity and a wide range for curvature measurements, with the advantage that the technique is cost-effective and easy to implement. All these features make this technique appealing for real sensing applications, such as structural health monitoring.

5.
Opt Express ; 24(5): 5654-5661, 2016 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-29092386

RESUMO

An ultracompact, cost-effective, and highly accurate fiber optic temperature sensor is proposed and demonstrated. The sensing head consists of Fabry-Perot microcavity formed by an internal mirror made of a thin titanium dioxide (TiO2) film and a microscopic segment of single-mode fiber covered with Poly(dimethylsiloxane) (PDMS). Due to the high thermo-optic coefficient of PDMS the reflectance of the fiber-PDMS interface varies strongly with temperature which in turn modifies the amplitude of the interference pattern. To quantify the changes of the latter we monitored the visibility of the interference pattern and analyzed it by means of the fast Fourier transform. Our sensor exhibits linear response, high sensitivity, and response time of 14 seconds. We believe that the microscopic dimensions along with the performance of the sensor here presented makes it appealing for sensing temperature in PDMS microfluidic circuits or in biological applications.

6.
Opt Express ; 23(17): 22141-8, 2015 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-26368188

RESUMO

We demonstrate the capability of an air cavity Fabry-Perot interferometer (FPI), built with a tapered lead-in fiber tip, to measure three parameters simultaneously, distance, group refractive index and thickness of transparent samples introduced in the cavity. Tapering the lead-in fiber enhances the light coupling back efficiency, therefore is possible to enlarge the air cavity without a significant deterioration of the fringe visibility. Fourier transformation, used to analyze the reflected optical spectrum of our FPI, simplify the calculus to determine the position, thickness and refractive index. Samples made of 7 different glasses; fused silica, BK7, BalF5, SF2, BaF51, SF15, and glass slides were used to test our FPI. Each sample was measured nine times and the results for position, thickness and refractive index showed differences of ± 0.7%, ± 0.1%, and ± 0.16% respectively. The evolution of thickness and refractive index of a block of polydimethylsiloxane (PDMS) elastomer due to temperature changes in the range of 25°C to 90°C were also measured. The coefficients of the thermal expansion and thermo-optic estimated were α = 4.71x10(-4)/°C and dn/dT = -4.66 x10(-4) RIU/°C, respectively.

7.
Opt Lett ; 36(11): 2122-4, 2011 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-21633469

RESUMO

We report the fabrication of a saturable absorber based on SU8 single wall carbon nanotube (SWCNT) composite material. Thin films with a controllable thickness can be fabricated using a simple and reliable process. These films can be inserted between two FC/APC connectors in order to have an inline saturable absorber. A passive mode-locked laser was built by interleaving the fiberized saturable absorber in an erbium-doped fiber (L-band) ring cavity laser. The laser produces 871 fs pulses with a repetition rate of 21.27 MHz and a maximum average power of 1 mW.


Assuntos
Tecnologia de Fibra Óptica/instrumentação , Lasers , Nanotecnologia/instrumentação , Nanotubos de Carbono/química , Desenho de Equipamento , Análise de Falha de Equipamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA