Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Proc Natl Acad Sci U S A ; 119(13): e2118803119, 2022 03 29.
Artigo em Inglês | MEDLINE | ID: mdl-35312355

RESUMO

SignificanceThe function of our biological clock is dependent on environmental light. Rodent studies have shown that there are multiple colors that affect the clock, but indirect measures in humans suggest blue light is key. We performed functional MRI studies in human subjects with unprecedented spatial resolution to investigate color sensitivity of our clock. Here, we show that narrowband blue, green, and orange light were all effective in changing neuronal activity of the clock. While the clock of nocturnal rodents is excited by light, the human clock responds with a decrease in neuronal activity as indicated by a negative BOLD response. The sensitivity of the clock to multiple colors should be integrated in light therapy aimed to strengthen our 24-h rhythms.


Assuntos
Relógios Circadianos , Ritmo Circadiano/fisiologia , Humanos , Luz , Fotobiologia , Núcleo Supraquiasmático/fisiologia
2.
Magn Reson Med ; 91(5): 1787-1802, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-37811778

RESUMO

PURPOSE: To create an inventory of image processing pipelines of arterial spin labeling (ASL) and list their main features, and to evaluate the capability, flexibility, and ease of use of publicly available pipelines to guide novice ASL users in selecting their optimal pipeline. METHODS: Developers self-assessed their pipelines using a questionnaire developed by the Task Force 1.1 of the ISMRM Open Science Initiative for Perfusion Imaging. Additionally, each publicly available pipeline was evaluated by two independent testers with basic ASL experience using a scoring system created for this purpose. RESULTS: The developers of 21 pipelines filled the questionnaire. Most pipelines are free for noncommercial use (n = 18) and work with the standard NIfTI (Neuroimaging Informatics Technology Initiative) data format (n = 15). All pipelines can process standard 3D single postlabeling delay pseudo-continuous ASL images and primarily differ in their support of advanced sequences and features. The publicly available pipelines (n = 9) were included in the independent testing, all of them being free for noncommercial use. The pipelines, in general, provided a trade-off between ease of use and flexibility for configuring advanced processing options. CONCLUSION: Although most ASL pipelines can process the common ASL data types, only some (namely, ASLPrep, ASLtbx, BASIL/Quantiphyse, ExploreASL, and MRICloud) are well-documented, publicly available, support multiple ASL types, have a user-friendly interface, and can provide a useful starting point for ASL processing. The choice of an optimal pipeline should be driven by specific data to be processed and user experience, and can be guided by the information provided in this ASL inventory.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Marcadores de Spin , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Artérias , Imagem de Perfusão , Circulação Cerebrovascular , Imageamento por Ressonância Magnética/métodos , Perfusão
3.
NMR Biomed ; : e5159, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38634301

RESUMO

Over the last decade, it has become evident that cerebrospinal fluid (CSF) plays a pivotal role in brain solute clearance through perivascular pathways and interactions between the brain and meningeal lymphatic vessels. Whereas most of this fundamental knowledge was gained from rodent models, human brain clearance imaging has provided important insights into the human system and highlighted the existence of important interspecies differences. Current gold standard techniques for human brain clearance imaging involve the injection of gadolinium-based contrast agents and monitoring their distribution and clearance over a period from a few hours up to 2 days. With both intrathecal and intravenous injections being used, which each have their own specific routes of distribution and thus clearance of contrast agent, a clear understanding of the kinetics associated with both approaches, and especially the differences between them, is needed to properly interpret the results. Because it is known that intrathecally injected contrast agent reaches the blood, albeit in small concentrations, and that similarly some of the intravenously injected agent can be detected in CSF, both pathways are connected and will, in theory, reach the same compartments. However, because of clear differences in relative enhancement patterns, both injection approaches will result in varying sensitivities for assessment of different subparts of the brain clearance system. In this opinion review article, the "EU Joint Programme - Neurodegenerative Disease Research (JPND)" consortium on human brain clearance imaging provides an overview of contrast agent pharmacokinetics in vivo following intrathecal and intravenous injections and what typical concentrations and concentration-time curves should be expected. This can be the basis for optimizing and interpreting contrast-enhanced MRI for brain clearance imaging. Furthermore, this can shed light on how molecules may exchange between blood, brain, and CSF.

4.
J Magn Reson Imaging ; 59(2): 431-449, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37141288

RESUMO

Neurofluids is a term introduced to define all fluids in the brain and spine such as blood, cerebrospinal fluid, and interstitial fluid. Neuroscientists in the past millennium have steadily identified the several different fluid environments in the brain and spine that interact in a synchronized harmonious manner to assure a healthy microenvironment required for optimal neuroglial function. Neuroanatomists and biochemists have provided an incredible wealth of evidence revealing the anatomy of perivascular spaces, meninges and glia and their role in drainage of neuronal waste products. Human studies have been limited due to the restricted availability of noninvasive imaging modalities that can provide a high spatiotemporal depiction of the brain neurofluids. Therefore, animal studies have been key in advancing our knowledge of the temporal and spatial dynamics of fluids, for example, by injecting tracers with different molecular weights. Such studies have sparked interest to identify possible disruptions to neurofluids dynamics in human diseases such as small vessel disease, cerebral amyloid angiopathy, and dementia. However, key differences between rodent and human physiology should be considered when extrapolating these findings to understand the human brain. An increasing armamentarium of noninvasive MRI techniques is being built to identify markers of altered drainage pathways. During the three-day workshop organized by the International Society of Magnetic Resonance in Medicine that was held in Rome in September 2022, several of these concepts were discussed by a distinguished international faculty to lay the basis of what is known and where we still lack evidence. We envision that in the next decade, MRI will allow imaging of the physiology of neurofluid dynamics and drainage pathways in the human brain to identify true pathological processes underlying disease and to discover new avenues for early diagnoses and treatments including drug delivery. Evidence level: 1 Technical Efficacy: Stage 3.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Animais , Humanos , Cidade de Roma , Encéfalo/patologia , Líquido Extracelular , Meninges
5.
J Biomed Sci ; 31(1): 37, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627751

RESUMO

BACKGROUND: Huntington's disease (HD) is marked by a CAG-repeat expansion in the huntingtin gene that causes neuronal dysfunction and loss, affecting mainly the striatum and the cortex. Alterations in the neurovascular coupling system have been shown to lead to dysregulated energy supply to brain regions in several neurological diseases, including HD, which could potentially trigger the process of neurodegeneration. In particular, it has been observed in cross-sectional human HD studies that vascular alterations are associated to impaired cerebral blood flow (CBF). To assess whether whole-brain changes in CBF are present and follow a pattern of progression, we investigated both resting-state brain perfusion and vascular reactivity longitudinally in the zQ175DN mouse model of HD. METHODS: Using pseudo-continuous arterial spin labelling (pCASL) MRI in the zQ175DN model of HD and age-matched wild-type (WT) mice, we assessed whole-brain, resting-state perfusion at 3, 6 and 9 and 13 months of age, and assessed hypercapnia-induced cerebrovascular reactivity (CVR), at 4.5, 6, 9 and 15 months of age. RESULTS: We found increased perfusion in cortical regions of zQ175DN HET mice at 3 months of age, and a reduction of this anomaly at 6 and 9 months, ages at which behavioural deficits have been reported. On the other hand, under hypercapnia, CBF was reduced in zQ175DN HET mice as compared to the WT: for multiple brain regions at 6 months of age, for only somatosensory and retrosplenial cortices at 9 months of age, and brain-wide by 15 months. CVR impairments in cortical regions, the thalamus and globus pallidus were observed in zQ175DN HET mice at 9 months, with whole brain reactivity diminished at 15 months of age. Interestingly, blood vessel density was increased in the motor cortex at 3 months, while average vessel length was reduced in the lateral portion of the caudate putamen at 6 months of age. CONCLUSION: Our findings reveal early cortical resting-state hyperperfusion and impaired CVR at ages that present motor anomalies in this HD model, suggesting that further characterization of brain perfusion alterations in animal models is warranted as a potential therapeutic target in HD.


Assuntos
Doença de Huntington , Humanos , Camundongos , Animais , Lactente , Doença de Huntington/genética , Estudos Transversais , Hipercapnia , Encéfalo , Modelos Animais de Doenças , Perfusão
6.
Magn Reson Med ; 89(6): 2281-2294, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36688262

RESUMO

PURPOSE: This work aims to explore the effect of Blood Brain Barrier (BBB) opening using ultrasound combined with microbubbles injection on cerebral blood flow in rats. METHODS: Two groups of n = 5 rats were included in this study. The first group was used to investigate the impact of BBB opening on the Arterial Spin Labeling (ASL) signal, in particular on the arterial transit time (ATT). The second group was used to analyze the spatiotemporal evolution of the change in cerebral blood flow (CBF) over time following BBB opening and validate these results using DSC-MRI. RESULTS: Using pCASL, a decrease in CBF of up to 29 . 6 ± 15 . 1 % $$ 29.6\pm 15.1\% $$ was observed in the target hemisphere, associated with an increase in arterial transit time. The latter was estimated to be 533 ± 121ms $$ 533\pm 12\mathrm{1ms} $$ in the BBB opening impacted regions against 409 ± 93ms $$ 409\pm 93\mathrm{ms} $$ in the contralateral hemisphere. The spatio-temporal analysis of CBF maps indicated a nonlocal hypoperfusion. DSC-MRI measurements were consistent with the obtained results. CONCLUSION: This study provided strong evidence that BBB opening using microbubble intravenous injection induces a transient hypoperfusion. A spatiotemporal analysis of the hypoperfusion changes allows to establish some points of similarity with the cortical spreading depression phenomenon.


Assuntos
Barreira Hematoencefálica , Imageamento por Ressonância Magnética , Ratos , Animais , Barreira Hematoencefálica/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Artérias , Isquemia , Circulação Cerebrovascular/fisiologia , Marcadores de Spin
7.
NMR Biomed ; 36(3): e4852, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36269104

RESUMO

For better quantification of perfusion with arterial spin labeling (ASL), partial volume correction (PVC) is used to disentangle the signals from gray matter (GM) and white matter within any voxel. Based on physiological considerations, PVC algorithms typically assume zero signal in the cerebrospinal fluid (CSF). Recent measurements, however, have shown that CSF-ASL signal can exceed 10% of GM signal, even when using recommended ASL labeling parameters. CSF signal is expected to particularly affect PVC results in the choroid plexus. This study aims to measure the impact of CSF signal on PVC perfusion measurements, and to investigate the potential use of PVC to retrieve pure CSF-ASL signal for blood-CSF barrier characterization. In vivo imaging included six pCASL sequences with variable label duration and post-labeling delay (PLD), and an eight-echo 3D-GRASE readout. A dataset was simulated to estimate the effect of CSF-PVC with known ground-truth parameters. Differences between the results of CSF-PVC and non-CSF-PVC were estimated for regions of interest (ROIs) based on GM probability, and a separate ROI isolating the choroid plexus. In vivo, the suitability of PVC-CSF signal as an estimate of pure CSF was investigated by comparing its time course with the long-TE CSF signal. Results from both simulation and in vivo data indicated that including the CSF signal in PVC improves quantification of GM CBF by approximately 10%. In simulated data, this improvement was greater for multi-PLD (model fitting) quantification than for single PLD (~1-5% difference). In the choroid plexus, the difference between CSF-PVC and non-CSF-PVC was much larger, averaging around 30%. Long-TE (pure) CSF signal could not be estimated from PVC CSF signal as it followed a different time course, indicating the presence of residual macrovascular signal in the PVC. The inclusion of CSF adds value to PVC for more accurate measurements of GM perfusion, and especially for quantification of perfusion in the choroid plexus and study of the glymphatic system.


Assuntos
Encéfalo , Circulação Cerebrovascular , Encéfalo/fisiologia , Marcadores de Spin , Circulação Cerebrovascular/fisiologia , Substância Cinzenta/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/métodos
8.
J Magn Reson Imaging ; 57(6): 1676-1695, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36912262

RESUMO

Preoperative clinical MRI protocols for gliomas, brain tumors with dismal outcomes due to their infiltrative properties, still rely on conventional structural MRI, which does not deliver information on tumor genotype and is limited in the delineation of diffuse gliomas. The GliMR COST action wants to raise awareness about the state of the art of advanced MRI techniques in gliomas and their possible clinical translation. This review describes current methods, limits, and applications of advanced MRI for the preoperative assessment of glioma, summarizing the level of clinical validation of different techniques. In this second part, we review magnetic resonance spectroscopy (MRS), chemical exchange saturation transfer (CEST), susceptibility-weighted imaging (SWI), MRI-PET, MR elastography (MRE), and MR-based radiomics applications. The first part of this review addresses dynamic susceptibility contrast (DSC) and dynamic contrast-enhanced (DCE) MRI, arterial spin labeling (ASL), diffusion-weighted MRI, vessel imaging, and magnetic resonance fingerprinting (MRF). EVIDENCE LEVEL: 3. TECHNICAL EFFICACY: Stage 2.


Assuntos
Neoplasias Encefálicas , Glioma , Imageamento por Ressonância Magnética , Humanos , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/cirurgia , Neoplasias Encefálicas/patologia , Meios de Contraste , Glioma/diagnóstico por imagem , Glioma/cirurgia , Glioma/patologia , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Período Pré-Operatório
9.
J Magn Reson Imaging ; 57(6): 1655-1675, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36866773

RESUMO

Preoperative clinical magnetic resonance imaging (MRI) protocols for gliomas, brain tumors with dismal outcomes due to their infiltrative properties, still rely on conventional structural MRI, which does not deliver information on tumor genotype and is limited in the delineation of diffuse gliomas. The GliMR COST action wants to raise awareness about the state of the art of advanced MRI techniques in gliomas and their possible clinical translation or lack thereof. This review describes current methods, limits, and applications of advanced MRI for the preoperative assessment of glioma, summarizing the level of clinical validation of different techniques. In this first part, we discuss dynamic susceptibility contrast and dynamic contrast-enhanced MRI, arterial spin labeling, diffusion-weighted MRI, vessel imaging, and magnetic resonance fingerprinting. The second part of this review addresses magnetic resonance spectroscopy, chemical exchange saturation transfer, susceptibility-weighted imaging, MRI-PET, MR elastography, and MR-based radiomics applications. Evidence Level: 3 Technical Efficacy: Stage 2.


Assuntos
Neoplasias Encefálicas , Glioma , Humanos , Imageamento por Ressonância Magnética/métodos , Glioma/diagnóstico por imagem , Glioma/cirurgia , Glioma/patologia , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/cirurgia , Neoplasias Encefálicas/patologia , Espectroscopia de Ressonância Magnética/métodos , Imagem de Difusão por Ressonância Magnética
10.
Alzheimers Dement ; 19(12): 5632-5641, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37303267

RESUMO

INTRODUCTION: We aimed to investigate the association between white matter hyperintensity (WMH) shape and volume and the long-term dementia risk in community-dwelling older adults. METHODS: Three thousand seventy-seven participants (mean age: 75.6 ± 5.2 years) of the Age Gene/Environment Susceptibility (AGES)-Reykjavik study underwent baseline 1.5T brain magnetic resonance imaging and were followed up for dementia (mean follow-up: 9.9 ± 2.6 years). RESULTS: More irregular shape of periventricular/confluent WMH (lower solidity (hazard ratio (95% confidence interval) 1.34 (1.17 to 1.52), p < .001) and convexity 1.38 (1.28 to 1.49), p < .001); higher concavity index 1.43 (1.32 to 1.54), p < .001) and fractal dimension 1.45 (1.32 to 1.58), p < .001)), higher total WMH volume (1.68 (1.54 to 1.87), p < .001), higher periventricular/confluent WMH volume (1.71 (1.55 to 1.89), p < .001), and higher deep WMH volume (1.17 (1.08 to 1.27), p < .001) were associated with an increased long-term dementia risk. DISCUSSION: WMH shape markers may in the future be useful in determining patient prognosis and may aid in patient selection for future preventive treatments in community-dwelling older adults.


Assuntos
Demência , Substância Branca , Humanos , Idoso , Idoso de 80 Anos ou mais , Substância Branca/diagnóstico por imagem , Substância Branca/patologia , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Prognóstico , Modelos de Riscos Proporcionais , Demência/diagnóstico por imagem , Demência/epidemiologia , Demência/patologia , Imageamento por Ressonância Magnética
11.
Magn Reson Med ; 87(3): 1276-1288, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34655092

RESUMO

PURPOSE: To employ an off-resonance saturation method to measure the mineral-iron pool in the postmortem brain, which is an endogenous contrast agent that can give information on cellular iron status. METHODS: An off-resonance saturation acquisition protocol was implemented on a 7 Tesla preclinical scanner, and the contrast maps were fitted to an established analytical model. The method was validated by correlation and Bland-Altman analysis on a ferritin-containing phantom. Mineral-iron maps were obtained from postmortem tissue of patients with neurological diseases characterized by brain iron accumulation, that is, Alzheimer disease, Huntington disease, and aceruloplasminemia, and validated with histology. Transverse relaxation rate and magnetic susceptibility values were used for comparison. RESULTS: In postmortem tissue, the mineral-iron contrast colocalizes with histological iron staining in all the cases. Iron concentrations obtained via the off-resonance saturation method are in agreement with literature. CONCLUSIONS: Off-resonance saturation is an effective way to detect iron in gray matter structures and partially mitigate for the presence of myelin. If a reference region with little iron is available in the tissue, the method can produce quantitative iron maps. This method is applicable in the study of diseases characterized by brain iron accumulation and can complement existing iron-sensitive parametric methods.


Assuntos
Distúrbios do Metabolismo do Ferro , Ferro , Encéfalo/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Minerais
12.
NMR Biomed ; 35(11): e4796, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35778859

RESUMO

Microvascular function is an important component in the physiology of muscle. One of the major parameters, blood perfusion, can be measured noninvasively and quantitatively by arterial spin labeling (ASL) MRI. Most studies using ASL in muscle have only reported data from a single slice, thereby assuming that muscle perfusion is homogeneous within muscle, whereas recent literature has reported proximodistal differences in oxidative capacity and perfusion. Here, we acquired pulsed ASL data in 12 healthy volunteers after dorsiflexion exercise in two slices separated distally by 7 cm. We combined this with a Look-Locker scheme to acquire images at multiple postlabeling delays (PLDs) and with a multiecho readout to measure T2 *. This enabled the simultaneous evaluation of quantitative muscle blood flow (MBF), arterial transit time (ATT), and T2 * relaxation time in the tibialis anterior muscle during recovery. Using repeated measures analyses of variance we tested the effect of time, slice location, and their interaction on MBF, ATT, and T2 *. Our results showed a significant difference as a function of time postexercise for all three parameters (MBF: F = 34.0, p < .0001; T2 *: F = 73.7, p < .0001; ATT: F = 13.6, p < .001) and no average differences between slices over the total time postexercise were observed. The interaction effect between time postexercise and slice location was significant for MBF and T2 * (F = 5.5, p = 0.02, F = 6.1, p = 0.02, respectively), but not for ATT (F = 2.2, p = .16). The proximal slice showed a higher MBF and a lower ATT than the distal slice during the first 2 min of recovery, and T2 * showed a delayed response in the distal slice. These results imply a higher perfusion and faster microvascular response to exercise in the proximal slice, in line with previous literature. Moreover, the differences in ATT indicate that it is difficult to correctly determine perfusion based on a single PLD as is commonly performed in the muscle literature.


Assuntos
Imageamento por Ressonância Magnética , Músculo Esquelético , Artérias , Circulação Cerebrovascular/fisiologia , Exercício Físico , Humanos , Imageamento por Ressonância Magnética/métodos , Músculo Esquelético/irrigação sanguínea , Músculo Esquelético/diagnóstico por imagem , Marcadores de Spin
13.
NMR Biomed ; 35(5): e4653, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34816501

RESUMO

Dynamic susceptibility contrast (DSC) MRI is clinically used to measure brain perfusion by monitoring the dynamic passage of a bolus of contrast agent through the brain. For quantitative analysis of the DSC images, the arterial input function is required. It is known that the original assumption of a linear relation between the R2(*) relaxation and the arterial contrast agent concentration is invalid, although the exact relation is as of yet unknown. Studying this relation in vitro is time-consuming, because of the widespread variations in field strengths, MRI sequences, contrast agents, and physiological conditions. This study aims to simulate the R2(*) versus contrast concentration relation under varying physiological and technical conditions using an adapted version of an open-source simulation tool. The approach was validated with previously acquired data in human whole blood at 1.5 T by means of a gradient-echo sequence (proof-of-concept). Subsequently, the impact of hematocrit, field strength, and oxygen saturation on this relation was studied for both gradient-echo and spin-echo sequences. The results show that for both gradient-echo and spin-echo sequences, the relaxivity increases with hematocrit and field strength, while the hematocrit dependency was nonlinear for both types of MRI sequences. By contrast, oxygen saturation has only a minor effect. In conclusion, the simulation setup has proven to be an efficient method to rapidly calibrate and estimate the relation between R2(*) and gadolinium concentration in whole blood. This knowledge will be useful in future clinical work to more accurately retrieve quantitative information on brain perfusion.


Assuntos
Meios de Contraste , Gadolínio DTPA , Hematócrito , Humanos , Campos Magnéticos , Imageamento por Ressonância Magnética/métodos
14.
Neuroimage ; 245: 118755, 2021 12 15.
Artigo em Inglês | MEDLINE | ID: mdl-34826596

RESUMO

The study of brain clearance mechanisms is an active area of research. While we know that the cerebrospinal fluid (CSF) plays a central role in one of the main existing clearance pathways, the exact processes for the secretion of CSF and the removal of waste products from tissue are under debate. CSF is thought to be created by the exchange of water and ions from the blood, which is believed to mainly occur in the choroid plexus. This exchange has not been thoroughly studied in vivo. We propose a modified arterial spin labeling (ASL) MRI sequence and image analysis to track blood water as it is transported to the CSF, and to characterize its exchange from blood to CSF. We acquired six pseudo-continuous ASL sequences with varying labeling duration (LD) and post-labeling delay (PLD) and a segmented 3D-GRASE readout with a long echo train (8 echo times (TE)) which allowed separation of the very long-T2 CSF signal. ASL signal was observed at long TEs (793 ms and higher), indicating presence of labeled water transported from blood to CSF. This signal appeared both in the CSF proximal to the choroid plexus and in the subarachnoid space surrounding the cortex. ASL signal was separated into its blood, gray matter and CSF components by fitting a triexponential function with T2s taken from literature. A two-compartment dynamic model was introduced to describe the exchange of water through time and TE. From this, a water exchange time from the blood to the CSF (Tbl->CSF) was mapped, with an order of magnitude of approximately 60 s.


Assuntos
Água Corporal/metabolismo , Líquido Cefalorraquidiano/metabolismo , Circulação Cerebrovascular/fisiologia , Plexo Corióideo/diagnóstico por imagem , Plexo Corióideo/metabolismo , Imageamento por Ressonância Magnética/métodos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Marcadores de Spin , Espaço Subaracnóideo/diagnóstico por imagem , Espaço Subaracnóideo/metabolismo
15.
Magn Reson Med ; 85(5): 2649-2660, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33252152

RESUMO

PURPOSE: Arterial spin labeling can be used to assess the transition time of water molecules across the blood-brain barrier when combined with sequence modules, which allow a separation of intravascular from tissue signal. The bipolar gradient technique measures the intravascular fraction by removing flowing spins. The T2 -relaxation-under-spin-tagging (TRUST) technique modulates the TE to differentiate between intravascular and extravascular spins based on T2 . These modules were combined into a single time-encoded pseudo-continuous arterial spin labeling sequence to compare their mechanisms of action as well as their assessment of water transition across the blood-brain barrier. METHODS: This protocol was acquired on a scanner with 9 healthy volunteers who provided written, informed consent. The sequence consisted of a Hadamard-encoded pseudo-continuous arterial spin labeling module, followed by the TRUST module (effective TEs of 0, 40, and 80 ms) and bipolar flow-crushing gradients (2, 4, and ∞ cm/s). An additional experiment was performed with TRUST and a 3D gradient and spin-echo readout. RESULTS: Gradients imperfectly canceled the intravascular signal, as evidenced by the presence of residual signal in the arteries at early postlabeling delays as well as the underestimation of the intravascular fraction as compared with the TRUST method. The TRUST module allowed us to detect the transport of water deeper into the vascular tree through changes in T2 than the used crusher gradients could, with their limited b-value. CONCLUSION: Of the implemented techniques, TRUST allowed us to follow intravascular signal deeper into the vascular tree than the approach with (relatively weak) crusher gradients when quantifying the transport time of water across the blood-brain barrier.


Assuntos
Barreira Hematoencefálica , Encéfalo , Barreira Hematoencefálica/diagnóstico por imagem , Circulação Cerebrovascular , Humanos , Imageamento por Ressonância Magnética , Marcadores de Spin , Água
16.
Magn Reson Med ; 86(5): 2441-2453, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34105189

RESUMO

PURPOSE: Multislice arterial spin labeling (ASL) MRI acquisitions are currently challenging in skeletal muscle because of long transit times, translating into low-perfusion SNR in distal slices when large spatial coverage is required. However, fiber type and oxidative capacity vary along the length of healthy muscles, calling for multislice acquisitions in clinical studies. We propose a new variant of flow alternating inversion recovery (FAIR) that generates sufficient ASL signal to monitor exercise-induced perfusion changes in muscle in two distant slices. METHODS: Label around and between two 7-cm distant slices was created by applying the presaturation/postsaturation and selective inversion modules selectively to each slice (split-label multislice FAIR). Images were acquired using simultaneous multislice EPI. We validated our approach in the brain to take advantage of the high resting-state perfusion, and applied it in the lower leg muscle during and after exercise, interleaved with a single-slice FAIR as a reference. RESULTS: We show that standard multislice FAIR leads to an underestimation of perfusion, while the proposed split-label multislice approach shows good agreement with separate single-slice FAIR acquisitions in brain, as well as in muscle following exercise. CONCLUSION: Split-label FAIR allows measuring muscle perfusion in two distant slices simultaneously without losing sensitivity in the distal slice.


Assuntos
Circulação Cerebrovascular , Imageamento por Ressonância Magnética , Perfusão , Reprodutibilidade dos Testes , Marcadores de Spin
17.
Magn Reson Med ; 85(5): 2580-2594, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33251644

RESUMO

PURPOSE: Flow-based arterial spin labeling (ASL) techniques provide a transit-time insensitive alternative to the more conventional spatially selective ASL techniques. However, it is not clear which flow-based ASL technique performs best and also, how these techniques perform outside the brain (taking into account eg, flow-dynamics, field-inhomogeneity, and organ motion). In the current study we aimed to compare 4 flow-based ASL techniques (ie, velocity selective ASL, acceleration selective ASL, multiple velocity selective saturation ASL, and velocity selective inversion prepared ASL [VSI-ASL]) to the current spatially selective reference techniques in brain (ie, pseudo-continuous ASL [pCASL]) and kidney (ie, pCASL and flow alternating inversion recovery [FAIR]). METHODS: Brain (n = 5) and kidney (n = 6) scans were performed in healthy subjects at 3T. Perfusion-weighted signal (PWS) maps were generated and ASL techniques were compared based on temporal SNR (tSNR), sensitivity to perfusion changes using a visual stimulus (brain) and robustness to respiratory motion by comparing scans acquired in paced-breathing and free-breathing (kidney). RESULTS: In brain, all flow-based ASL techniques showed similar tSNR as pCASL, but only VSI-ASL showed similar sensitivity to perfusion changes. In kidney, all flow-based ASL techniques had comparable tSNR, although all lower than FAIR. In addition, VSI-ASL showed a sensitivity to B1 -inhomogeneity. All ASL techniques were relatively robust to respiratory motion. CONCLUSION: In both brain and kidney, flow-based ASL techniques provide a planning-free and transit-time insensitive alternative to spatially selective ASL techniques. VSI-ASL shows the most potential overall, showing similar performance as the golden standard pCASL in brain. However, in kidney, a reduction of B1 -sensitivity of VSI-ASL is necessary to match the performance of FAIR.


Assuntos
Algoritmos , Imagem de Perfusão , Encéfalo/diagnóstico por imagem , Circulação Cerebrovascular , Humanos , Rim/diagnóstico por imagem , Imageamento por Ressonância Magnética , Razão Sinal-Ruído , Marcadores de Spin
18.
NMR Biomed ; 34(9): e4568, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34050996

RESUMO

Alzheimer's disease (AD) is the leading cause of cognitive impairment and dementia in elderly individuals. According to the current biomarker framework for "unbiased descriptive classification", biomarkers of neurodegeneration, "N", constitute a critical component in the tri-category "A/T/N" system. Current biomarkers of neurodegeneration suffer from potential drawbacks such as requiring invasive lumbar puncture, involving ionizing radiation, or representing a late, irreversible marker. Recent human studies have suggested that reduced brain oxygen metabolism may be a new functional marker of neurodegeneration in AD, but the heterogeneity and the presence of mixed pathology in human patients did not allow a full understanding of the role of oxygen extraction and metabolism in AD. In this report, global brain oxygen metabolism and related physiological parameters were studied in two AD mouse models with relatively pure pathology, using advanced MRI techniques including T2 -relaxation-under-spin-tagging (TRUST) and phase contrast (PC) MRI. Additionally, regional cerebral blood flow (CBF) was determined with pseudocontinuous arterial spin labeling. Reduced global oxygen extraction fraction (by -18.7%, p = 0.008), unit-mass cerebral metabolic rate of oxygen (CMRO2 ) (by -17.4%, p = 0.04) and total CMRO2 (by -30.8%, p < 0.001) were observed in Tau4RΔK mice-referred to as the tau AD model-which manifested pronounced neurodegeneration, as measured by diminished brain volume (by -15.2%, p < 0.001). Global and regional CBF in these mice were not different from those of wild-type mice (p > 0.05), suggesting normal vascular function. By contrast, in B6;SJL-Tg [APPSWE]2576Kha (APP) mice-referred to as the amyloid AD model-no brain volume reduction, as well as relatively intact brain oxygen extraction and metabolism, were found (p > 0.05). Consistent with the imaging data, behavioral measures of walking distance were impaired in Tau4RΔK mice (p = 0.004), but not in APP mice (p = 0.88). Collectively, these findings support the hypothesis that noninvasive MRI measurement of brain oxygen metabolism may be a promising biomarker of neurodegeneration in AD.


Assuntos
Doença de Alzheimer/diagnóstico por imagem , Doença de Alzheimer/metabolismo , Amiloide/metabolismo , Encéfalo/metabolismo , Imageamento por Ressonância Magnética , Proteínas tau/metabolismo , Precursor de Proteína beta-Amiloide/metabolismo , Animais , Comportamento Animal , Modelos Animais de Doenças , Feminino , Masculino , Camundongos Endogâmicos C57BL , Oxigênio/metabolismo , Marcadores de Spin
19.
J Med Biol Eng ; 41(2): 115-125, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33293909

RESUMO

Purpose: There is an annual incidence of 50,000 glioma cases in Europe. The optimal treatment strategy is highly personalised, depending on tumour type, grade, spatial localization, and the degree of tissue infiltration. In research settings, advanced magnetic resonance imaging (MRI) has shown great promise as a tool to inform personalised treatment decisions. However, the use of advanced MRI in clinical practice remains scarce due to the downstream effects of siloed glioma imaging research with limited representation of MRI specialists in established consortia; and the associated lack of available tools and expertise in clinical settings. These shortcomings delay the translation of scientific breakthroughs into novel treatment strategy. As a response we have developed the network "Glioma MR Imaging 2.0" (GliMR) which we present in this article. Methods: GliMR aims to build a pan-European and multidisciplinary network of experts and accelerate the use of advanced MRI in glioma beyond the current "state-of-the-art" in glioma imaging. The Action Glioma MR Imaging 2.0 (GliMR) was granted funding by the European Cooperation in Science and Technology (COST) in June 2019. Results: GliMR's first grant period ran from September 2019 to April 2020, during which several meetings were held and projects were initiated, such as reviewing the current knowledge on advanced MRI; developing a General Data Protection Regulation (GDPR) compliant consent form; and setting up the website. Conclusion: The Action overcomes the pre-existing limitations of glioma research and is funded until September 2023. New members will be accepted during its entire duration.

20.
Magn Reson Med ; 83(1): 254-261, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31429990

RESUMO

PURPOSE: To investigate the heating induced by (pseudo)-continuous arterial spin labeling ((p)CASL) sequences in vivo at 9.4T and to evaluate the benefit of a dedicated labeling coil. METHODS: Temperature was measured continuously in the brain, neck, and rectum of 9 rats with fiber-optic temperature probes while running pCASL-EPI and CASL-EPI sequences, with labeling B1 amplitudes (B1ave ) of 3, 5, and 7 µT and using a dedicated labeling RF coil or a volume coil. From the temperature time courses, the corresponding specific absorption rate (SAR) was computed. A trade-off between SAR and labeling quality was determined based on measured inversion efficiencies. RESULTS: ASL experiments with standard parameters (B1ave = 5 µT, Tacq = 4 min, labeling with volume coil) lead to a brain temperature increase due to RF of 0.72 ± 0.46 K for pCASL and 0.25 ± 0.17 K for CASL. Using a dedicated labeling coil reduced the RF-induced SAR by a factor of 10 in the brain and a factor of 2 in the neck. Besides SAR due to RF, heat from the coil decoupling circuits produced significant temperature increases. When labeling with a dedicated coil, this mechanism was the dominant source of brain heating. At equivalent RF-SAR, CASL provided slightly superior label efficiency to pCASL and is therefore the preferred sequence when an ASL coil is available. CONCLUSION: B1ave = 4-5 µT provided a good compromise between label efficiency and SAR, both for pCASL and CASL. The sensitivity of animals to heating should be taken into account when optimizing preclinical ASL protocols and may require reducing scan duration or lowering B1ave .


Assuntos
Encéfalo/diagnóstico por imagem , Angiografia por Ressonância Magnética , Pescoço/diagnóstico por imagem , Reto/diagnóstico por imagem , Marcadores de Spin , Animais , Tecnologia de Fibra Óptica , Temperatura Alta , Campos Magnéticos , Masculino , Fibras Ópticas , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA