Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Nanobiotechnology ; 12: 44, 2014 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-25424410

RESUMO

BACKGROUND: Magnetic nanoparticles functionalized antibodies are used for in-vitro assays on bio-markers. This work demonstrates the synthesis of high-quality magnetic nanoparticles coated with antibodies against carcinoembryonic antigen (CEA). Various characterizations, such as particle size, particle suspension, bio-activity and the stability of bio-magnetic nanoparticles suspended in liquid, are studied. The properties for the assay of CEA molecules in serum are also studied. The assay method used is so-called immunomagnetic reduction. RESULTS: The results show that the effects of common materials in serum that interfere with detected signals are not significant. The low-detection limit is 0.21 ng/ml, which is well below the clinical threshold of 2.5 ng/ml. CONCLUSIONS: The dynamic range for the assay of CEA molecules in serum is 500 ng/ml. By assaying serum CEA molecules from 24 normal controls and 30 colorectal-cancer patients, the threshold for the serum-CEA concentration to diagnose colorectal cancer is 4.05 ng/ml, which results in a clinical sensitivity of 0.90 and specificity of 0.87.


Assuntos
Anticorpos/química , Biomarcadores Tumorais/sangue , Antígeno Carcinoembrionário/sangue , Neoplasias Colorretais/sangue , Imunoensaio/métodos , Nanopartículas de Magnetita , Anticorpos/imunologia , Biomarcadores Tumorais/imunologia , Estudos de Casos e Controles , Humanos , Limite de Detecção , Nanopartículas de Magnetita/química , Tamanho da Partícula , Temperatura
2.
Dement Geriatr Cogn Dis Extra ; 12(2): 82-89, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35702342

RESUMO

Background: For assays using immunomagnetic reduction, a reagent composed of antibody-functionalized magnetic nanoparticles is dispersed in phosphate-buffered saline solution. The real-time signals of alternating-current (ac) magnetic susceptibility, χac, of the reagent are subsequently recorded after mixing the reagent with a biofluid sample. After mixing the reagent and sample, the reduction in χac of the mixture is calculated and used to quantify the concentration of the target biomarker in the sample. The reduction does not occur immediately but rather occurs at some time after mixing. This observation implies that the time elapsed before recording the real-time signals of χac of a reagent-sample mixture needs to be investigated to ensure that the signals are fully recorded. In this work, the effect of time to detection on the measured concentrations of proteins in human plasma after mixing the reagent and sample is examined. Methods: The proteins analyzed are related to Alzheimer's disease: amyloid ß 1-40, amyloid ß 1-42, and Tau protein. The investigated times to detection after the mixing the reagent and sample are 0, 20, 30, 40, and 120 min. Results: The results show that the recording of real-time signals of χac should be conducted within 20 min after mixing the reagent and sample.

3.
Neurol Ther ; 10(2): 1015-1028, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34515952

RESUMO

INTRODUCTION: Concentrations of plasma biomarkers associated with Alzheimer's disease have been reported to be as low as several tens of picograms/milliliter (pg/ml). However, in assays measuring these biomarkers, it is likely that repeated measurements are necessary to obtain reliable values. METHODS: We performed assays as a single test or as duplicate, quadruplicate, fivefold and tenfold repeated tests, on samples spiked with different concentrations of amyloid ß 1-40 (Aß1-40; 1-1000 pg/ml), Aß1-42 (1-30,000 pg/ml) and total Tau protein (T-Tau; 0.1-1000 pg/ml), with the aim to to calculate the coefficients of variation (CVs). RESULTS: The results demonstrated common changes in the CVs with changes in the number of tests for a given sample: the CVs decreased with increases in the number of tests from one to ten. All CV values were distributed within the range of 0.35 to 15.5%; as such, the CV values were all lower than the acceptable value of 20%. CONCLUSION: Based on this study, a single assay of Aß1-40, Aß1-42 and T-Tau, respectively, provides reliable results in terms of the measurement of that plasma biomarker.

4.
Bioorg Med Chem ; 16(18): 8619-26, 2008 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-18723357

RESUMO

Research studies in the field of C(60) fullerene derivatives have significantly increased due to the broad range of biological activities that were found for these compounds. We designed and prepared a new C(60) fullerene hybrid bearing thalidomide as a potential double-action anti-inflammatory agent, capable of simultaneous inhibition of LPS-induced NO and TNF-alpha production. The C(60) fulleropyrrolidine-thalidomide dyad, CLT, was an effective agent to suppress the release of NO and TNF-alpha by the LPS-stimulated macrophages RAW 264.7. Ten micromolars of CLT effectively inhibited LPS-induced NO and TNF-alpha production by 47.3+/-4.2% and 70.2+/-4% with respected to the control, respectively. Furthermore, preliminary biochemical investigation revealed that CLT was a potent agent to suppress both LPS-induced intracellular ROS production and iNOS expression, and CLT also inhibited the phosphorylation of ERK which is an important protein kinase involved in the activation of TNF-alpha synthesis in LPS-activated macrophages. We believed that the studies herein would hold promise for future development of a new generation of potent anti-inflammatory agents.


Assuntos
Anti-Inflamatórios/farmacologia , Fulerenos/farmacologia , Macrófagos/efeitos dos fármacos , Pirrolidinas/farmacologia , Talidomida/farmacologia , Animais , Anti-Inflamatórios/síntese química , Sobrevivência Celular , Células Cultivadas , MAP Quinases Reguladas por Sinal Extracelular/antagonistas & inibidores , MAP Quinases Reguladas por Sinal Extracelular/metabolismo , Fulerenos/química , Lipopolissacarídeos , Macrófagos/metabolismo , Óxido Nítrico/antagonistas & inibidores , Óxido Nítrico/metabolismo , Óxido Nítrico Sintase Tipo II/genética , Óxido Nítrico Sintase Tipo II/metabolismo , Fosforilação/efeitos dos fármacos , Pirrolidinas/síntese química , Espécies Reativas de Oxigênio/antagonistas & inibidores , Espécies Reativas de Oxigênio/metabolismo , Talidomida/análogos & derivados , Talidomida/síntese química , Fator de Necrose Tumoral alfa/antagonistas & inibidores , Fator de Necrose Tumoral alfa/metabolismo
5.
PLoS One ; 10(9): e0138207, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26380977

RESUMO

Shrimp white spot disease (WSD), which is caused by white spot syndrome virus (WSSV), is one of the world's most serious shrimp diseases. Our objective in this study was to use an immunomagnetic reduction (IMR) assay to develop a highly sensitive, automatic WSSV detection platform targeted against ICP11 (the most highly expressed WSSV protein). After characterizing the magnetic reagents (Fe3O4 magnetic nanoparticles coated with anti ICP11), the detection limit for ICP11 protein using IMR was approximately 2 x 10(-3) ng/ml, and the linear dynamic range of the assay was 0.1~1 x 10(6) ng/ml. In assays of ICP11 protein in pleopod protein lysates from healthy and WSSV-infected shrimp, IMR signals were successfully detected from shrimp with low WSSV genome copy numbers. We concluded that this IMR assay targeting ICP11 has potential for detecting the WSSV.


Assuntos
Proteínas de Artrópodes/imunologia , Imunoprecipitação/métodos , Nanopartículas de Magnetita , Penaeidae/virologia , Vírus da Síndrome da Mancha Branca 1/metabolismo , Doenças dos Animais/diagnóstico , Doenças dos Animais/virologia , Animais , Proteínas de Artrópodes/metabolismo , Western Blotting , Imunoprecipitação/veterinária , Limite de Detecção , Fenômenos Magnéticos , Nanopartículas de Magnetita/química , Reação em Cadeia da Polimerase/métodos , Reação em Cadeia da Polimerase/veterinária , Proteínas do Envelope Viral/análise , Proteínas do Envelope Viral/genética , Proteínas do Envelope Viral/imunologia , Proteínas do Envelope Viral/metabolismo , Vírus da Síndrome da Mancha Branca 1/genética , Vírus da Síndrome da Mancha Branca 1/imunologia , Vírus da Síndrome da Mancha Branca 1/isolamento & purificação
6.
ACS Chem Neurosci ; 4(12): 1530-6, 2013 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-24090201

RESUMO

A highly sensitive immunoassay, the immunomagnetic reduction, is used to measure several biomarkers for plasma that is related to Alzheimer's disease (AD). These biomarkers include Aß-40, Aß-42, and tau proteins. The samples are composed of four groups: healthy controls (n=66), mild cognitive impairment (MCI, n=22), very mild dementia (n=23), and mild-to-serve dementia, all due to AD (n=22). It is found that the concentrations of both Aß-42 and tau protein for the healthy controls are significantly lower than those of all of the other groups. The sensitivity and the specificity of plasma Aß-42 and tau protein in differentiating MCI from AD are all around 0.9 (0.88-0.97). However, neither plasma Aß-42 nor tau-protein concentration is an adequate parameter to distinguish MCI from AD. A parameter is proposed, which is the product of plasma Aß-42 and tau-protein levels, to differentiate MCI from AD. The sensitivity and specificity are found to be 0.80 and 0.82, respectively. It is concluded that the use of combined plasma biomarkers not only allows the differentiation of the healthy controls and patients with AD in both the prodromal phase and the dementia phase, but it also allows AD in the prodromal phase to be distinguished from that in the dementia phase.


Assuntos
Doença de Alzheimer/diagnóstico , Peptídeos beta-Amiloides/sangue , Biomarcadores/sangue , Disfunção Cognitiva/diagnóstico , Proteínas tau/sangue , Adulto , Idoso , Idoso de 80 Anos ou mais , Doença de Alzheimer/sangue , Disfunção Cognitiva/sangue , Feminino , Humanos , Imunoensaio/métodos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA