Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
JACC Clin Electrophysiol ; 4(7): 893-901, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-30025689

RESUMO

OBJECTIVES: This study sought to document the closure rate, safety, and stroke rate after thoracoscopic left atrial appendage (LAA) clipping. BACKGROUND: The LAA is the main source of stroke in patients with atrial fibrillation, and thoracoscopic clipping may provide a durable and safe closure technique. METHODS: The investigators studied consecutive patients undergoing clipping as part of a thoracoscopic maze procedure in 4 referral centers (the Netherlands and the United States) from 2012 to 2016. Completeness of LAA closure was assessed by either computed tomography (n = 100) or transesophageal echocardiography (n = 122). The primary outcome was complete LAA closure (absence of residual LAA flow and pouch <10 mm). The secondary outcomes were 30-day complications; the composite of ischemic stroke, hemorrhagic stroke, or transient ischemic attack; and all-cause mortality. RESULTS: A total of 222 patients were included, with a mean age of 66 ± 9 years, and 68.5% were male. The mean CHA2DS2-VASc (congestive heart failure, hypertension, age ≥75 years, diabetes mellitus, prior stroke or transient ischemic attack or thromboembolism, vascular disease, age 65 to 74 years, sex category [female]) score was 2.3 ± 1.0. Complete LAA closure was achieved in 95.0% of patients. There were no intraoperative or clip-related complications, and the overall 30-day freedom from any complication rate was 96.4%. The freedom from cerebrovascular events after surgery was 99.1% after median follow-up of 20 months (interquartile range: 14 to 25 months; 369 patient-years of follow-up), and overall survival was 98.6%. The observed rate of cerebrovascular events after LAA clipping was low (0.5 per 100 patient-years). CONCLUSIONS: LAA clipping during thoracoscopic ablation is a feasible and safe technique for closure of the LAA in patients with atrial fibrillation. The lower than expected rate of cerebrovascular events after deployment was likely multifactorial, including not only LAA closure, but also the effect of oral anticoagulation and rhythm control.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Procedimentos Cirúrgicos Cardíacos , Toracoscopia , Idoso , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/métodos , Procedimentos Cirúrgicos Cardíacos/mortalidade , Procedimentos Cirúrgicos Cardíacos/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Acidente Vascular Cerebral/epidemiologia , Toracoscopia/efeitos adversos , Toracoscopia/métodos , Toracoscopia/mortalidade , Toracoscopia/estatística & dados numéricos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA