Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Strahlenther Onkol ; 2024 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-39283343

RESUMO

BACKGROUND: Ventricular tachycardia (VT) is a life-threatening arrhythmia originating from the heart's ventricles. Traditional treatments include antiarrhythmic medications, implantable cardioverter-defibrillators (ICDs), and catheter ablation. Stereotactic body radiation therapy (SBRT) targeting the arrhythmogenic focus in the left ventricle-stereotactic arrhythmia radioablation (STAR)-is an emerging treatment and may offer a potential solution for patients with refractory VT. OBJECTIVE: We designed an interventional prospective clinical trial in Israel aligned with the STOPSTORM.eu consortium's benchmarks, recommendations, and directives to assess the safety and efficacy of STAR in patients with refractory VT. METHODS: Our phase I/II single-institutional trial was approved by the Ministry of Health of Israel for 10 patients, initially assessing safety in the first 3 patients. We included patients with ICDs experiencing symptomatic monomorphic VT after an inadequate response to previous therapies. The primary endpoints were treatment-related serious adverse events and a reduction in VT burden as assessed by ICD interrogation. Secondary outcomes included a reduction in antiarrhythmic medications and changes in quality of life. RESULTS: From August 2023 to August 2024, 3 patients underwent STAR treatment. The prescription dose was a single fraction of 25 Gy. Planning target volumes were 47.8, 49.7, and 91.8 cc, and treatment was successfully delivered with no grade 3 or higher adverse events reported. Over a follow-up period of 12 months for the first patient and 8 months for the second one, no VT events were recorded after treatment. The third patient died from progressive heart failure 3 months after treatment. Left ventricular ejection fraction remained stable, and no significant radiation-induced inflammatory changes were noted. CONCLUSION: The initial results of this trial suggest that STAR can reduce VT episodes in patients with refractory VT without severe adverse effects. The study highlights the importance of international collaboration and standardization in pioneering new treatments. Further follow-up and additional patient data will be necessary to confirm these findings and evaluate long-term outcomes, including potential adjustments to antiarrhythmic medication regimens.

2.
Strahlenther Onkol ; 199(7): 621-630, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37285038

RESUMO

BACKGROUND: Single-session cardiac stereotactic radiation therapy (SBRT) has demonstrated promising results for patients with refractory ventricular tachycardia (VT). However, the full safety profile of this novel treatment remains unknown and very limited data from prospective clinical multicenter trials are available. METHODS: The prospective multicenter multiplatform RAVENTA (radiosurgery for ventricular tachycardia) study assesses high-precision image-guided cardiac SBRT with 25 Gy delivered to the VT substrate determined by high-definition endocardial and/or epicardial electrophysiological mapping in patients with refractory VT ineligible for catheter ablation and an implanted cardioverter defibrillator (ICD). Primary endpoint is the feasibility of full-dose application and procedural safety (defined as an incidence of serious [grade ≥ 3] treatment-related complications ≤ 5% within 30 days after therapy). Secondary endpoints comprise VT burden, ICD interventions, treatment-related toxicity, and quality of life. We present the results of a protocol-defined interim analysis. RESULTS: Between 10/2019 and 12/2021, a total of five patients were included at three university medical centers. In all cases, the treatment was carried out without complications. There were no serious potentially treatment-related adverse events and no deterioration of left ventricular ejection fraction upon echocardiography. Three patients had a decrease in VT episodes during follow-up. One patient underwent subsequent catheter ablation for a new VT with different morphology. One patient with local VT recurrence died 6 weeks after treatment in cardiogenic shock. CONCLUSION: The interim analysis of the RAVENTA trial demonstrates early initial feasibility of this new treatment without serious complications within 30 days after treatment in five patients. Recruitment will continue as planned and the study has been expanded to further university medical centers. TRIAL REGISTRATION NUMBER: NCT03867747 (clinicaltrials.gov). Registered March 8, 2019. Study start: October 1, 2019.


Assuntos
Radiocirurgia , Taquicardia Ventricular , Humanos , Radiocirurgia/métodos , Volume Sistólico , Estudos Prospectivos , Qualidade de Vida , Estudos de Viabilidade , Função Ventricular Esquerda , Taquicardia Ventricular/radioterapia , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
3.
Pacing Clin Electrophysiol ; 46(8): 875-881, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37483154

RESUMO

AIM: The implementation of 3D mapping systems plays an important role in interventional electrophysiology (EP) in recent years. The aim of the present study was to evaluate use of 3D mapping systems regarding fluoroscopy and procedure duration. METHOD: In the "Go for Zero Fluoroscopy" project 25 European centers provided data of consecutive EP procedures. Data on use of 3D mapping systems as well as utilization of contact force catheters and multipolar mapping catheters were associated with fluoroscopy time, dose area product (DAP), and procedure duration. RESULT: A 3D mapping system was used in 966 (54%) cases. Use of 3D mapping for atrioventricular nodal reentry tachycardia (AVNRT) was associated with reduced fluoroscopy time (p < 0.001), DAP (p = 0.04) but increased procedure time (p = 0.029). Moreover, fluoroscopy time (p < 0.001) and DAP (p = 0.005) were significantly lower in the 3D mapping group in ablation of typical atrial flutter. However, the procedure time (p < 0.001) increased. Use of 3D mapping in the ablation of accessory pathway (AP) was associated with reduced fluoroscopy time (p < 0.001) and DAP (p < 0.001) with no significant increase in procedure time (p = 0.066). In the case of atrial fibrillation, a 3D mapping system was used in 485 patients (75.8%). Additional use of a contact force catheter was associated with lower fluoroscopy time (p < 0.001) and DAP (p < 0.001). Use of a multipolar mapping catheter was associated with lower fluoroscopy time (p = 0.002). The implementation of 3D mapping systems in the ablation of ventricular tachycardias resulted in a significant increase in the procedure time (p = 0.001) without significant differences regarding the DAP (p = 0.773) and fluoroscopy time (p = 0.249). CONCLUSION: Use of 3D mapping systems in ablation of supraventricular tachycardias is associated with lower radiation exposure. Nevertheless, the procedure time often increases, except in the case of ablation for AP. Use of contact force catheters and multipolar mapping catheters is associated with yet lower radiation exposure values. Prospective randomized studies are needed to further elucidate potential benefit of these technological tools.


Assuntos
Feixe Acessório Atrioventricular , Fibrilação Atrial , Ablação por Cateter , Humanos , Estudos Prospectivos , Resultado do Tratamento , Fibrilação Atrial/cirurgia , Feixe Acessório Atrioventricular/cirurgia , Eletrofisiologia Cardíaca , Fluoroscopia/métodos , Ablação por Cateter/métodos
4.
Sensors (Basel) ; 22(5)2022 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-35271182

RESUMO

In patients with newly diagnosed heart failure with reduced ejection fraction (HFrEF), three months of optimal therapy are recommended before considering a primary preventive implantable cardioverter-defibrillator (ICD). It is unclear which patients benefit from a prolonged waiting period under protection of the wearable cardioverter-defibrillator (WCD) to avoid unnecessary ICD implantations. This study included all patients receiving a WCD for newly diagnosed HFrEF (n = 353) at our center between 2012 and 2017. Median follow-up was 2.7 years. From baseline until three months, LVEF improved in patients with all peripartum cardiomyopathy (PPCM), myocarditis, dilated cardiomyopathy (DCM), or ischemic cardiomyopathy (ICM). Beyond this time, LVEF improved in PPCM and DCM only (10 ± 8% and 10 ± 12%, respectively), whereas patients with ICM showed no further improvement. The patients with newly diagnosed HFrEF were compared to 29 patients with a distinct WCD indication, which is an explantation of an infected ICD. This latter group had a higher incidence of WCD shocks and poorer overall survival. All-cause mortality should be considered when deciding on WCD prescription. In patients with newly diagnosed HFrEF, the potential for delayed LVEF recovery should be considered when timing ICD implantation, especially in patients with PPCM and DCM.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/efeitos adversos , Insuficiência Cardíaca/diagnóstico , Humanos , Volume Sistólico , Função Ventricular Esquerda
5.
Sensors (Basel) ; 21(23)2021 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-34883802

RESUMO

The wearable cardioverter-defibrillator (WCD) is used in patients with newly diagnosed heart failure and reduced ejection fraction (HFrEF). In addition to arrhythmic events, the WCD provides near-continuous telemetric heart failure monitoring. The purpose of this study was to evaluate the clinical relevance of additionally recorded parameters, such as heart rate or step count. We included patients with newly diagnosed HFrEF prescribed with a WCD. Via the WCD, step count and heart rate were acquired, and an approximate for heart rate variability (HRV5) was calculated. Multivariate analysis was performed to analyze predictors for an improvement in left ventricular ejection fraction (LVEF). Two hundred and seventy-six patients (31.9% female) were included. Mean LVEF was 25.3 ± 8.5%. Between the first and last seven days of usage, median heart rate fell significantly (p < 0.001), while median step count and HRV5 significantly increased (p < 0.001). In a multivariate analysis, a delta of HRV5 > 23 ms was an independent predictor for LVEF improvement of ≥10% between prescription and 3-month follow-up. Patients with newly diagnosed HFrEF showed significant changes in heart rate, step count, and HRV5 between the beginning and end of WCD prescription time. HRV5 was an independent predictor for LVEF improvement and could serve as an early indicator of treatment response.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Dispositivos Eletrônicos Vestíveis , Morte Súbita Cardíaca , Estudos de Viabilidade , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Masculino , Volume Sistólico , Função Ventricular Esquerda
6.
J Cardiovasc Electrophysiol ; 31(10): 2689-2695, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32648343

RESUMO

INTRODUCTION: Noninvasive ablative radiotherapy of cardiac arrhythmias (stereotactic ablative body radiation) has shown promising initial results. Precise targeting of the arrhythmogenic substrate is paramount to limit adverse effects to healthy myocardium, organs at risk, and cardiac implantable electronic devices. Using electroanatomic maps for treatment planning is technically challenging. METHODS AND RESULTS: Using the free open-source 3D Slicer software platform we established a workflow for high-precision target definition based on electroanatomic maps. An import plug-in for 3D Slicer has been designed that reads electroanatomic maps generated with three mapping systems in widespread clinical use. Using our proposed workflow in a real-world patient case we were able to align the map to the computed tomography (CT) with a mean distance of 3.1 mm. Thus, points defined on the map were translated into CT space with high accuracy and a radiotherapy treatment volume was defined in CT space based on these map-derived points. CONCLUSION: We describe a novel high-precision target definition method for stereotactic ablation of cardiac arrhythmias. Multimodal integration of the electroanatomic map with the planning CT allows for highly accurate localization of previously identified electrophysiological features in CT space. It remains to be shown whether this novel planning workflow leads to superior ablation outcomes when compared with other approaches.


Assuntos
Ablação por Cateter , Coração , Humanos , Software , Tomografia Computadorizada por Raios X , Fluxo de Trabalho
7.
J Cardiovasc Electrophysiol ; 31(12): 3286-3292, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33017069

RESUMO

INTRODUCTION: In patients with a left ventricular assist device (LVAD), the subcutaneous implantable cardioverter-defibrillator (S-ICD) can be an alternative to transvenous ICD systems due to reduced risk of systemic infection, which could lead to extraction of the ICD as well as the LVAD. S-ICD eligibility is lower in patients with LVAD than in patients with end-stage heart failure without LVAD. Several reports have shown inappropriate S-ICD therapy in the coexistence of LVAD and S-ICD. The aim of the present study was to evaluate S-ICD eligibility in patients with LVAD using the established electrocardiogram (ECG)-based screening test as well as a novel device-based screening test to identify potentially inappropriate S-ICD sensing in this specific patient cohort. METHODS AND RESULTS: The present study included 115 patients implanted with an LVAD. The standard ECG-based screening test and a novel device-based screening test were performed in all patients. Eighty patients (70%) were eligible for S-ICD therapy with the standard ECG-based screening test. Performance of the novel device-based screening test identified device-device interference in 14 of these 80 patients (12%). CONCLUSION: Using a novel extended device-based S-ICD screening method, a small number of patients with LVAD deemed eligible for S-ICD with the standard ECG-based screening test exhibit device-device interference. Careful S-ICD screening should be performed in patients with LVAD, who are candidates for S-ICD therapy, to prevent inappropriate sensing or ICD therapy.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Coração Auxiliar , Estudos de Coortes , Eletrocardiografia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Coração Auxiliar/efeitos adversos , Humanos
9.
Europace ; 19(10): 1723-1729, 2017 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-27915266

RESUMO

AIMS: Overlap syndromes of long QT 3 syndrome (LQT3) and the Brugada syndrome (BrS) have been reported. Identification of patients with an overlapping phenotype is crucial before initiation of Class I antiarrhythmic drugs for LQT3. Aim of the present study was to elucidate the yield of ajmaline challenge in unmasking the Brugada phenotype in patients with LQT3 caused by the most common mutation, SCN5A-E1784K. METHODS AND RESULTS: Consecutive families in tertiary referral centres diagnosed with LQT3 caused by SCN5A-E1784K were included in the study. Besides routine clinical work-up, ajmaline challenge was performed after informed consent. A total of 23 subjects (11 female, mean age 27 ± 14 years) from 4 unrelated families with a family history of sudden cardiac death and familial diagnosis of the SCN5A-E1784K mutation underwent ajmaline challenge and genetic testing. Sixteen subjects (9 female) were found to be heterozygous carriers of SCN5A-E1784K. Ajmaline challenge was positive in 12 out of the 16 (75%) mutation carriers, but negative in all non-carriers. Following ajmaline, a significant shortening of the rate-corrected JT (JTc) interval was observed in mutation carriers. The baseline JTc interval was significantly longer in mutation carriers with a positive ajmaline challenge compared with those with a negative one. CONCLUSION: Overlap of LQT3 and BrS in patients carrying the most common mutation is high. Therefore, ajmaline challenge represents an important step to rule out potential BrS overlap in these patients before starting sodium channel blockers for the beneficial effect of QT shortening in LQT3.


Assuntos
Ajmalina/administração & dosagem , Antiarrítmicos/administração & dosagem , Síndrome do QT Longo/diagnóstico , Síndrome do QT Longo/genética , Mutação , Canal de Sódio Disparado por Voltagem NAV1.5/efeitos dos fármacos , Canal de Sódio Disparado por Voltagem NAV1.5/genética , Bloqueadores do Canal de Sódio Disparado por Voltagem/administração & dosagem , Potenciais de Ação/efeitos dos fármacos , Adolescente , Adulto , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/genética , Síndrome de Brugada/fisiopatologia , Análise Mutacional de DNA , Diagnóstico Diferencial , Eletrocardiografia , Feminino , Predisposição Genética para Doença , Alemanha , Frequência Cardíaca/efeitos dos fármacos , Humanos , Síndrome do QT Longo/tratamento farmacológico , Síndrome do QT Longo/fisiopatologia , Masculino , Pessoa de Meia-Idade , Fenótipo , Valor Preditivo dos Testes , Centros de Atenção Terciária , Fatores de Tempo , Adulto Jovem
10.
BMC Cardiovasc Disord ; 17(1): 244, 2017 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-28899346

RESUMO

BACKGROUND: Wolff-Parkinson-White (WPW) syndrome and idiopathic left ventricular tachycardia (ILVT) are rare and up to now the coexistence of both entities has rarely been reported. In patients with ventricular preexcitation the underlying mechanism of paroxysmal tachycardia most likely is atrioventricular reentrant tachycardia (AVRT). However, without ECG documentation of the tachycardia diagnosis of the underlying mechanism cannot be made due to similar clinical presentation of AVRT and ILVT. CASE PRESENTATION: We report a case of a two-staged occurrence of two rare arrhythmias in a young adult, who was admitted to our hospital twice within 6 months because of paroxysmal tachycardia. WPW syndrome and ILVT as underlying arrhythmias have been diagnosed and were ablated successfully. CONCLUSIONS: This case highlights the diagnostic defiance of rare tachycardia entities and the paramount importance of ECG documentation and analysis of all available tachycardia ECGs.


Assuntos
Ablação por Cateter/métodos , Eletrocardiografia , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia Paroxística/diagnóstico , Taquicardia Ventricular/diagnóstico , Adulto , Diagnóstico Diferencial , Sistema de Condução Cardíaco/fisiopatologia , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Taquicardia por Reentrada no Nó Atrioventricular/complicações , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Taquicardia Paroxística/complicações , Taquicardia Paroxística/cirurgia , Taquicardia Ventricular/complicações , Taquicardia Ventricular/cirurgia , Síndrome de Wolff-Parkinson-White/diagnóstico
11.
Eur Heart J Open ; 4(5): oeae070, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39253029

RESUMO

Aims: Female physicians are underrepresented in invasive electrophysiology (EP) for multiple reasons. Despite an increasing focus on the topic, it is unclear what aspects are predominant. Methods and results: We conducted a survey on career paths of current or former EP fellows in Germany to elucidate how gender and family affected their careers. 231 fellows (24.2% female) were invited. 110 participants completed the survey (30.9% female, mean age 41.0 ± 5.0 years, and 79.1% with children). Female and male participants with children reported similar career goals and achievements before parenthood, but afterwards women changed their career paths more often. Major reasons were personal priorities followed by lack of flexibility at work and at home. Women covered the majority of childcare. At the time of the survey, 80.0% of women and 96.4% of men with a former career goal of invasive EP were active in invasive EP. Independent of age, women were in lower-level positions, had accomplished fewer professional achievements, were less satisfied with their work and had fewer children. 56.5% of women did not feel supported by their employers regarding family issues. 82.6% reported there was no satisfactory day care. 69.6% were unable to continue to follow their career during pregnancy, mostly due to restrictions by employers (75.0%). Dedicated policies for pregnant workers or support programmes were scarce. Conclusion: Beside the distribution of childcare at home, lack of flexibility and support by employers as well as working and fluoroscopy restrictions during pregnancy hamper women in EP and should be addressed.

12.
Heart Rhythm ; 2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38823665

RESUMO

BACKGROUND: The potential risk of embolic events during ablation in the left ventricle (LV) with a heated saline-enhanced radiofrequency (SERF) needle-tip ablation catheter has not been characterized. OBJECTIVE: This study aimed to investigate the formation of microemboli or other untoward events during SERF ablation. METHODS: Ninety-three radiofrequency (RF) ablation procedures were performed in the LV of 14 pigs by using a SERF catheter (35 W, 70 seconds, and 60°C; normal or degassed saline [NS or DS] irrigation with a flow rate of 10 mL/min) vs a standard irrigated-tip radiofrequency (S-RF) catheter (30 or 50 W, 30 seconds, and 17 mL/min). Microbubble formation was graded on the basis of intracardiac echocardiography. Microbubbles, microembolic signals, and microparticles were monitored using our established model. RESULTS: There was no significant difference in microbubble volume among SERF-NS, SERF-DS, and S-RF 30 W with "grade 1" intracardiac echocardiography microbubbles (median and 25th-75th percentiles 0.201 [0.011-3.13], 0.455 [0.06-2.66], and 0.004 µL [0.00-0.16 µL], respectively). There was no significant difference in microembolic signals among SERF-NS, SERF-DS, and S-RF 30 W with grade 1 bubbles (n = 8.0 ± 5.8, n = 7.6 ± 4.2, and n = 6.1 ± 6.1, respectively). Both SERF-NS and SERF-DS created larger lesions than did both S-RF 30 W and S-RF 50 W deliveries (mean 1241.5 ± 658.6, 1497.7 ± 893.4, 75.0 ± 24.8, and 184.0 ± 93.8 mm3; P < .001). There was no significant difference in microparticle incidence among groups (P = .675). No evidence of embolic events was found in the brain and other organs at the histology assessment. CONCLUSION: In the setting of SERF ablation, significantly large LV lesions can be created without any increment in embolic microbubble or particle events. Grade 1 microbubble is related to the efficacy and safety.

13.
Radiother Oncol ; 200: 110499, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-39242029

RESUMO

BACKGROUND: Stereotactic arrhythmia radioablation (STAR) is a therapeutic option for ventricular tachycardia (VT) where catheter-based ablation is not feasible or has previously failed. Target definition and its transfer from electro-anatomic maps (EAM) to radiotherapy treatment planning systems (TPS) is challenging and operator-dependent. Software solutions have been developed to register EAM with cardiac CT and semi-automatically transfer 2D target surface data into 3D CT volume coordinates. Results of a cross-validation study of two conceptually different software solutions using data from the RAVENTA trial (NCT03867747) are reported. METHODS: Clinical Target Volumes (CTVs) were created from target regions delineated on EAM using two conceptually different approaches by separate investigators on data of 10 patients, blinded to each other's results. Targets were transferred using 3D-3D registration and 2D-3D registration, respectively. The resulting CTVs were compared in a core-lab using two complementary analysis software packages for structure similarity and geometric characteristics. RESULTS: Volumes and surface areas of the CTVs created by both methods were comparable: 14.88 ± 11.72 ml versus 15.15 ± 11.35 ml and 44.29 ± 33.63 cm2 versus 46.43 ± 35.13 cm2. The Dice-coefficient was 0.84 ± 0.04; median surface-distance and Hausdorff-distance were 0.53 ± 0.37 mm and 6.91 ± 2.26 mm, respectively. The 3D-center-of-mass difference was 3.62 ± 0.99 mm. Geometrical volume similarity was 0.94 ± 0.05 %. CONCLUSION: The STAR targets transferred from EAM to TPS using both software solutions resulted in nearly identical 3D structures. Both solutions can be used for QA (quality assurance) and EAM-to-TPS transfer of STAR-targets. Semi-automated methods could potentially help to avoid mistargeting in STAR and offer standardized workflows for methodically harmonized treatments.


Assuntos
Radiocirurgia , Planejamento da Radioterapia Assistida por Computador , Humanos , Planejamento da Radioterapia Assistida por Computador/métodos , Radiocirurgia/métodos , Taquicardia Ventricular/radioterapia , Taquicardia Ventricular/diagnóstico por imagem , Software , Tomografia Computadorizada por Raios X , Imageamento Tridimensional , Masculino , Feminino , Reprodutibilidade dos Testes
14.
PLoS One ; 18(4): e0284419, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37071637

RESUMO

BACKGROUND: The number of left ventricular assist devices (LVADs) implanted in patients with end-stage heart failure is increasing. In this patient cohort, subcutaneous implantable cardioverter defibrillators (S-ICDs) could be a promising alternative to transvenous ICDs due to lower infection rates and avoidance of venous access. However, eligibility for the S-ICD depends on ECG features that may be influenced by an LVAD. The aim of the present study was a prospective evaluation of S-ICD eligibility before and after LVAD implantation. METHODS: The study recruited all patients presenting at Hannover Medical School for LVAD implantation between 2016 and 2020. S-ICD eligibility was evaluated using the ECG-based and the device-based S-ICD screening test before and after LVAD implantation. RESULTS: Twenty-two patients (57.3 ± 8.7 years of age, 95.5% male) were included in the analysis. The most common underlying diseases were dilated cardiomyopathy (n = 16, 72.7%) and ischemic cardiomyopathy (n = 5, 22.7%). Before LVAD implantation 16 patients were found eligible for the S-ICD according to both screening tests (72.7%), but only 7 patients were eligible after LVAD, 31.8%; p = 0.05). Oversensing due to electromagnetic interference was observed in 6 patients (66.6%) found ineligible for S-ICD after LVAD implantation. A lower S wave amplitude in leads I (p = 0.009), II (p = 0.006) and aVF (p = 0.006) before LVAD implantation was associated with higher rate of S-ICD ineligibility after LVAD implantation. CONCLUSION: LVAD implantation can impair S-ICD eligibility. Patients with lower S wave amplitude in leads I, II and aVF were more likely to be ineligible for S-ICD implantation after LVAD implantation. Thus, S-ICD therapy should be carefully considered in patients who are candidates for LVAD therapy.


Assuntos
Desfibriladores Implantáveis , Coração Auxiliar , Humanos , Masculino , Idoso de 80 Anos ou mais , Feminino , Coração Auxiliar/efeitos adversos , Cardioversão Elétrica , Desfibriladores Implantáveis/efeitos adversos , Eletrocardiografia , Implantação do Embrião
15.
Front Cardiovasc Med ; 10: 1270422, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38164465

RESUMO

Background: The echocardiographic parameters total atrial conduction time (PA-TDI duration), left atrial (LA) volume index (LAVI), and LA strain reflect adverse atrial remodeling and predict atrial fibrillation (AF). Objectives: The aim of this study was to investigate echocardiographic parameters indicating reverse LA remodeling and potential associations with AF recurrence after pulmonary vein isolation (PVI). Methods: This prospective observational study consecutively enrolled patients scheduled for PVI for symptomatic AF. Electrocardiogram (ECG) test and transthoracic echocardiography were performed the day before and after PVI and again 3 months later. AF recurrence was determined by Holter ECG at 3 months, and telephone follow-up at 12 months, after PVI. The parameters of LA remodeling [PA-TDI, LAVI, and LA strain analysis: reservoir strain (LASr), conduit strain (LAScd), contraction strain (LASct)] were determined by transthoracic echocardiography. Results: A total of 48 patients were included in the study (mean age: 61.4 ± 12.2 years). PA-TDI significantly decreased the day after PVI compared with the baseline (septal PA-TDI 103 ± 13 vs. 82 ± 14.9 ms, p ≤ 0.001; lateral PA-TDI 122.4 ± 14.8 vs. 106.9 ± 14.4 ms, p ≤ 0.001) and at the 3-month follow-up (septal PA-TDI: 77.8 ± 14.5, p ≤ 0.001; lateral PA-TDI 105.2 ± 16.1, p ≤ 0.001). LAVI showed a significant reduction at the 3-month follow-up compared with the baseline (47.7 ± 14.4 vs. 40.5 ± 9.7, p < 0.05). LASr, LAScd, and LASct did not change after PVI compared with the baseline. AF recurred in 10 patients after PVI (21%). Septal PA-TDI, septal a', and LAVI/a' determined the day after PVI were associated with AF recurrence. Conclusion: Changes in echocardiographic parameters of LA remodeling and function indicate that functional electromechanical recovery preceded morphological reverse remodeling of the left atrium after PVI. Furthermore, these changes in echocardiographic parameters indicating LA reverse remodeling after PVI may identify patients at high risk of AF recurrence.

16.
J Pharmacol Toxicol Methods ; 124: 107471, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37690768

RESUMO

Computer-based analysis of long-term electrocardiogram (ECG) monitoring in animal models represents a cost and time-consuming process as manual supervision is often performed to ensure accuracy in arrhythmia detection. Here, we investigate the performance and feasibility of three ECG interval analysis approaches A) attribute-based, B) attribute- and pattern recognition-based and C) combined approach with additional manual beat-to-beat analysis (gold standard) with regard to subsequent detection of ventricular arrhythmias (VA) and time consumption. ECG analysis was performed on ECG raw data of 5 male cynomolgus monkeys (1000 h total, 2 × 100 h per animal). Both approaches A and B overestimated the total number of arrhythmias compared to gold standard (+8.92% vs. +6.47%). With regard to correct classification of detected VA event numbers (accelerated idioventricular rhythms [AIVR], ventricular tachycardia [VT]) approach B revealed higher accuracy compared to approach A. Importantly, VA burden (% of time) was precisely depicted when using approach B (-1.13%), whereas approach A resulted in relevant undersensing of ventricular arrhythmias (-11.76%). Of note, approach A and B could be performed with significant less working time (-95% and - 91% working time) compared to gold standard. In sum, we show that a combination of attribute-based and pattern recognition analysis (approach B) can reproduce VA burden with acceptable accuracy without using manual supervision. Since this approach allowed analyses to be performed with distinct time saving it represents a valuable approach for cost and time efficient analysis of large preclinical ECG datasets.


Assuntos
Arritmias Cardíacas , Eletrocardiografia , Animais , Masculino , Macaca fascicularis , Estudos de Viabilidade , Arritmias Cardíacas/diagnóstico , Computadores
17.
Circ Arrhythm Electrophysiol ; 16(6): e011179, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37183678

RESUMO

BACKGROUND: Particle therapy is a noninvasive, catheter-free modality for cardiac ablation. We previously demonstrated the efficacy for creating ablation lesions in the porcine heart. Despite several earlier studies, the exact mechanism of early biophysical effects of proton and photon beam delivery on the myocardium remain incompletely resolved. METHODS: Ten normal and 9 infarcted in situ porcine hearts received proton beam irradiation (40 Gy) delivered to the left ventricular myocardium with follow-up for 8 weeks. High-resolution electroanatomical mapping of the left ventricular was performed at baseline and follow-up. Bipolar voltage amplitude, conduction velocity, and connexin-43 were determined within the irradiated and nonirradiated areas. RESULTS: The irradiated area in normal hearts showed a significant reduction of bipolar voltage amplitude (10.1±4.9 mV versus 5.7±3.2, P<0.0001) and conduction velocity (85±26 versus 55±13 cm/s, P=0.03) beginning at 4 weeks after irradiation. In infarcted myocardium after irradiation, bipolar voltage amplitude of the infarct scar (2.0±2.9 versus 0.8±0.7 mV, P=0.008) was significantly reduced as well as the conduction velocity in the infarcted heart (43.7±15.7 versus 26.3±11.4 cm/s, P=0.02). There were no significant changes in bipolar voltage amplitude and conduction velocity in nonirradiated myocardium. Myocytolysis, capillary hyperplasia, and dilation were seen in the irradiated myocardium 8 weeks after irradiation. Active caspase-3 and reduction of connexin-43 expression began in irradiated myocardium 1 week after irradiation and decreased over 8 weeks. CONCLUSIONS: Irradiation of the myocardium with proton beams reduce connexin-43 expression, conduction velocity, and bipolar conducted electrogram amplitude in a large porcine model. The changes in biomarkers preceded electrophysiological changes after proton beam therapy.


Assuntos
Ablação por Cateter , Terapia com Prótons , Taquicardia Ventricular , Suínos , Animais , Prótons , Miocárdio/patologia , Conexinas
18.
Phys Imaging Radiat Oncol ; 25: 100406, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36655216

RESUMO

A novel quality assurance process for electroanatomical mapping (EAM)-to-radiotherapy planning imaging (RTPI) target transport was assessed within the multi-center multi-platform framework of the RAdiosurgery for VENtricular TAchycardia (RAVENTA) trial. A stand-alone software (CARDIO-RT) was developed to enable platform independent registration of EAM and RTPI of the left ventricle (LV), based on pre-generated radiotherapy contours (RTC). LV-RTC were automatically segmented into the American-Heart-Association 17-segment-model and a manual 3D-3D method based on EAM 3D-geometry data and a semi-automated 2D-3D method based on EAM screenshot projections were developed. The quality of substrate transfer was evaluated in five clinical cases and the structural analyses showed substantial differences between manual target transfer and target transport using CARDIO-RT.

19.
Radiother Oncol ; 189: 109910, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37709052

RESUMO

BACKGROUND: Stereotactic arrhythmia radioablation (STAR) appears to be beneficial in selected patients with therapy-refractory ventricular tachycardia (VT). However, high-dose radiotherapy used for STAR-treatment may affect functioning of the patients' implantable cardioverter defibrillator (ICD) by direct effects of radiation on ICD components or cardiac tissue. Currently, the effect of STAR on ICD functioning remains unknown. METHODS: A retrospective pre-post multicenter study evaluating ICD functioning in the 12-month before and after STAR was performed. Patients with (non)ischemic cardiomyopathies with therapy-refractory VT and ICD who underwent STAR were included and the occurrence of ICD-related adverse events was collected. Evaluated ICD parameters included sensing, capture threshold and impedance. A linear mixed-effects model was used to investigate the association between STAR, radiotherapy dose and changes in lead parameters over time. RESULTS: In total, 43 patients (88% male) were included in this study. All patients had an ICD with an additional right atrial lead in 34 (79%) and a ventricular lead in 17 (40%) patients. Median ICD-generator dose was 0.1 Gy and lead tip dose ranged from 0-32 Gy. In one patient (2%), a reset occurred during treatment, but otherwise, STAR and radiotherapy dose were not associated with clinically relevant alterations in ICD leads parameters. CONCLUSIONS: STAR treatment did not result in major ICD malfunction. Only one radiotherapy related adverse event occurred during the study follow-up without patient harm. No clinically relevant alterations in ICD functioning were observed after STAR in any of the leads. With the reported doses STAR appears to be safe.


Assuntos
Desfibriladores Implantáveis , Isquemia Miocárdica , Taquicardia Ventricular , Humanos , Masculino , Feminino , Desfibriladores Implantáveis/efeitos adversos , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/terapia , Estudos Retrospectivos , Arritmias Cardíacas/etiologia , Isquemia Miocárdica/etiologia , Resultado do Tratamento
20.
J Clin Med ; 11(9)2022 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-35566556

RESUMO

Mobile health technologies are gaining importance in clinical decision-making. With the capability to monitor the patient's heart rhythm, they have the potential to reduce the time to confirm a diagnosis and therefore are useful in patients eligible for screening of atrial fibrillation as well as in patients with symptoms without documented symptom rhythm correlation. Such is crucial to enable an adequate arrhythmia management including the possibility of a catheter ablation. After ablation, wearables can help to search for recurrences, in symptomatic as well as in asymptomatic patients. Furthermore, those devices can be used to search for concomitant arrhythmias and have the potential to help improving the short- and long-term patient management. The type of wearable as well as the adequate technology has to be chosen carefully for every situation and every individual patient, keeping different aspects in mind. This review aims to describe and to elaborate a potential workflow for the role of wearables for cardiac rhythm monitoring regarding detection and management of arrhythmias before and after cardiac electrophysiological procedures.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA