Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 35(2): 230-237, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38047467

RESUMO

INTRODUCTION: The extravascular implantable cardioverter defibrillator (EV ICD) has extended projected battery longevity compared to the subcutaneous implantable cardioverter defibrillator (S-ICD). This study used modeling to characterize the need for generator changes, long-term complications, and overall costs for both the EV ICD and S-ICD in healthcare systems of various countries. METHODS: Battery longevity data were modeled using a Markov model from averages reported in device labeling for the S-ICD and with engineering estimates based on real life usage from EV ICD Pivotal Study patient data to introduce variability. Clinical demographic data were derived from published literature. The primary outcomes were defined as the number of generator replacement surgeries, complications, and total healthcare system costs due to battery depletion over the expected lifetime of patients receiving EV ICD or S-ICD therapy. RESULTS: Average modeled battery longevity was determined to be 7.3 years for the S-ICD versus 11.8 years for the EV ICD. The probability of a complication after a replacement procedure was 1.4%, with an operative mortality rate of 0.02%. The use of EV ICD was associated with 1.4-1.6 fewer replacements on average over an expected patient lifetime as compared to S-ICD and a 24.3%-26.0% reduction in cost. A one-way sensitivity analysis of the model for the US healthcare system found that use of an EV ICD resulted in a reduction in replacement surgeries of greater than 1 (1.1-1.6) along with five-figure cost savings in all scenarios ($18 602-$40 948). CONCLUSION: The longer projected battery life of the EV ICD has the potential to meaningfully reduce long-term morbidity and healthcare resources related to generator changes from the perspective of multiple diverse healthcare systems.


Assuntos
Desfibriladores Implantáveis , Humanos , Falha de Equipamento , Cardioversão Elétrica/efeitos adversos , Previsões , Redução de Custos
2.
Artigo em Inglês | MEDLINE | ID: mdl-39080873

RESUMO

BACKGROUND: Implantable cardioverter-defibrillators are used globally and are reliable, but complications related to transvenous leads remain a concern. Evidence related to the incidence and costs of those complications is heterogeneous with respect to scope and healthcare system. This analysis aims to create estimates of the incidence and costs of tricuspid valve (TV) complications, lead failures, and lead extractions from a single large real-world data set. METHODS AND RESULTS: This retrospective longitudinal cohort study used the deidentified Medicare Fee for Service administrative claims database. A total of 116 036 patients with de novo transvenous ICD implant were analyzed. Mean hospital costs were $26 903 for tricuspid valve complications, $20 851 for lead failures, and $22 278 for lead extractions. CONCLUSIONS: Transvenous ICD lead complications incur significant costs to patients, hospitals, and payers when they occur. Advancements in lead technology that reduce these complications could bring significant clinical and economic value.

3.
Europace ; 26(7)2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38890126

RESUMO

AIMS: Cardiac implantable electronic device (CIED) infections are a burden to hospitals and costly for healthcare systems. Chronic kidney disease (CKD) increases the risk of CIED infections, but its differential impact on healthcare utilization, costs, and outcomes is not known. METHODS AND RESULTS: This retrospective analysis used de-identified Medicare Fee-for-Service claims to identify patients implanted with a CIED from July 2016 to December 2020. Outcomes were defined as hospital days and costs within 12 months post-implant, post-infection CKD progression, and mortality. Generalized linear models were used to calculate results by CKD and infection status while controlling for other comorbidities, with differences between cohorts representing the incremental effect associated with CKD. A total of 584 543 patients had a CIED implant, of which 26% had CKD and 1.4% had a device infection. The average total days in hospital for infected patients was 23.5 days with CKD vs. 14.5 days (P < 0.001) without. The average cost of infection was $121 756 with CKD vs. $55 366 without (P < 0.001), leading to an incremental cost associated with CKD of $66 390. Infected patients with CKD were more likely to have septicaemia or severe sepsis than those without CKD (11.0 vs. 4.6%, P < 0.001). After infection, CKD patients were more likely to experience CKD progression (hazard ratio 1.26, P < 0.001) and mortality (hazard ratio 1.89, P < 0.001). CONCLUSION: Cardiac implantable electronic device infection in patients with CKD was associated with more healthcare utilization, higher cost, greater disease progression, and greater mortality compared to patients without CKD.


Assuntos
Desfibriladores Implantáveis , Progressão da Doença , Marca-Passo Artificial , Infecções Relacionadas à Prótese , Insuficiência Renal Crônica , Humanos , Insuficiência Renal Crônica/terapia , Insuficiência Renal Crônica/economia , Insuficiência Renal Crônica/mortalidade , Masculino , Feminino , Desfibriladores Implantáveis/economia , Desfibriladores Implantáveis/efeitos adversos , Estudos Retrospectivos , Idoso , Estados Unidos/epidemiologia , Infecções Relacionadas à Prótese/economia , Infecções Relacionadas à Prótese/mortalidade , Marca-Passo Artificial/economia , Marca-Passo Artificial/efeitos adversos , Marca-Passo Artificial/estatística & dados numéricos , Idoso de 80 Anos ou mais , Custos de Cuidados de Saúde/estatística & dados numéricos , Medicare/economia , Aceitação pelo Paciente de Cuidados de Saúde/estatística & dados numéricos , Tempo de Internação/estatística & dados numéricos , Tempo de Internação/economia
4.
BMC Cardiovasc Disord ; 23(1): 8, 2023 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-36624380

RESUMO

BACKGROUND: Pulmonary vein isolation (PVI) is recommended to treat paroxysmal and persistent atrial fibrillation (AF). This analysis aimed to assess the hospital efficiency of single-shot cryoballoon ablation (CBA) and point-by-point radiofrequency ablation (RFA). METHODS: The discrete event simulation used PVI procedure times from the FREEZE Cohort study to establish the electrophysiology (EP) lab occupancy time. 1000 EP lab days were simulated according to an illustrative German hospital, including 3 PVI cases per day using CBA at one site and RFA at the other. RESULTS: The analysis included 1560 CBA patients and 1344 RFA patients from the FREEZE Cohort. Some baseline patients' characteristics were different between groups (age, AF type, and some concomitant diseases), without being statistically associated to ablation procedure time. Mean procedure time was 122.2 ± 39.4 min for CBA and 160.3 ± 53.5 min for RFA (p < 0.0001). RFA was associated with a more than five-fold increase of cumulative overtime compared to CBA over the simulated period (1285 h with RFA and 253 h with CBA). 70.7% of RFA lab days included overtime versus 25.7% for CBA. CBA was associated with more days with an additional hour at the end of the EP lab shift compared to RFA (47.8% vs 11.5% days with one hour left, respectively). CONCLUSION: CBA is faster and more predictable than point-by-point RFA, and enables improvements in EP lab efficiency, including: fewer cumulative overtime hours, more days where overtime is avoided and more days with remaining time for the staff or for any EP lab usage. Clinical trial registration NCT01360008 (first registration 25/05/2011).


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Estudos de Coortes , Criocirurgia/efeitos adversos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Eletrofisiologia , Resultado do Tratamento , Recidiva
5.
Europace ; 23(9): 1446-1455, 2021 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-33755136

RESUMO

AIM: The Prevention of Arrhythmia Device Infection Trial (PADIT) infection risk score, developed based on a large prospectively collected data set, identified five independent predictors of cardiac implantable electronic device (CIED) infection. We performed an independent validation of the risk score in a data set extracted from U.S. healthcare claims. METHODS AND RESULTS: Retrospective identification of index CIED procedures among patients aged ≥18 years with at least one record of a CIED procedure between January 2011 and September 2014 in a U.S health claims database. PADIT risk factors and major CIED infections (with system removal, invasive procedure without system removal, or infection-attributable death) were identified through diagnosis and procedure codes. The data set was randomized by PADIT score into Data Set A (60%) and Data Set B (40%). A frailty model allowing multiple procedures per patient was fit using Data Set A, with PADIT score as the only predictor, excluding patients with prior CIED infection. A data set of 54 042 index procedures among 51 623 patients with 574 infections was extracted. Among patients with no history of prior CIED infection, a 1 unit increase in the PADIT score was associated with a relative 28% increase in infection risk. Prior CIED infection was associated with significant incremental predictive value (HR 5.66, P < 0.0001) after adjusting for PADIT score. A Harrell's C-statistic for the PADIT score and history of prior CIED infection was 0.76. CONCLUSION: The PADIT risk score predicts increased CIED infection risk, identifying higher risk patients that could potentially benefit from targeted interventions to reduce the risk of CIED infection. Prior CIED infection confers incremental predictive value to the PADIT score.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Infecções Relacionadas à Prótese , Adolescente , Adulto , Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/efeitos adversos , Atenção à Saúde , Eletrônica , Humanos , Marca-Passo Artificial/efeitos adversos , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/prevenção & controle , Estudos Retrospectivos , Fatores de Risco
6.
J Cardiovasc Electrophysiol ; 31(3): 712-717, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32009284

RESUMO

INTRODUCTION: Infections of cardiac implantable electronic devices remain a prevalent health concern necessitating the advent of novel preventative strategies. Based on the observation that bacterial infections of the Micra transcatheter pacemaker device are extremely rare, we examine the effect of parylene coating on bacterial adhesion and growth. METHODS: Bacterial growth was compared on polyurethane coated, bare, or parylene coated titanium surfaces. Eight test samples per bacterial species and material combination were incubated with Staphylococcus Aureus or Pseudomonas aeruginosa for 24 hours and then assayed for bacterial growth. The surface contact angle was also characterized by measuring the angle between the tangent to the surface of a liquid droplet made with the surface of the solid sample. RESULTS: The mean bacterial colony counts were significantly reduced for both parylene coated titanium versus bare samples (3.69 ± 0.27 and 4.80 ± 0.48 log[CFU/mL] respectively for S. aureus [P < .001] and 5.51 ± 0.27 and 6.08 ± 0.11 log[CFU/mL] respectively for P. aeruginosa [P < .001]), and for parylene coated titanium versus polyurethane samples (4.27 ± 0.42 and 5.40 ± 0.49 log[CFU/mL] respectively for S. aureus [P < .001] and 4.23 ± 0.42 and 4.84 ± 0.32 log[CFU/mL] respectively for P. aeruginosa [P = .006]). Parylene coated titanium samples had a higher contact angle compared with bare titanium, but lower compared with polyurethane (mean contact angle 87.5 ± 3.1 degrees parylene, 73.3 ± 3.7 degrees titanium [P < .001 vs parylene], and 94.8 ± 3.7 degrees polyurethane [P = .002 vs parylene]). CONCLUSIONS: Parylene coating significantly reduced the ability of bacteria to grow in colony count assays suggesting that this could contribute to the reduction of bacterial infections of Micra transcatheter pacemakers.


Assuntos
Antibacterianos/farmacologia , Aderência Bacteriana/efeitos dos fármacos , Materiais Revestidos Biocompatíveis , Contaminação de Equipamentos , Marca-Passo Artificial/microbiologia , Polímeros/farmacologia , Pseudomonas aeruginosa/efeitos dos fármacos , Staphylococcus aureus/efeitos dos fármacos , Xilenos/farmacologia , Contagem de Colônia Microbiana , Pseudomonas aeruginosa/crescimento & desenvolvimento , Staphylococcus aureus/crescimento & desenvolvimento
8.
Pacing Clin Electrophysiol ; 42(8): 1105-1110, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31232461

RESUMO

BACKGROUND: The Micra clinical trials have enrolled more than 2500 patients without any reported device-related infections that required removal during follow-up. Leadless pacemakers might be more resistant to bacterial seeding due to smaller surface area and a greater tendency for encapsulation. OBJECTIVE: To analyze the incidence and outcomes of serious infectious events (SIEs: bacteremia or endocarditis) that developed during follow-up in patients with history of Micra leadless pacemaker implantation. METHODS: SIE and outcomes were characterized based upon adverse event reports. Among 720 patients implanted with Micra in the investigational device exemption trial, we identified 16 patients who had documented 21 SIEs during follow-up. RESULTS: Among patients with SIEs, mean age was 71.9 ± 11.7 years. SIEs occurred at a mean 4.8 ± 4.5 months after implant and patients were followed for 13.1 ± 9.1 months after documentation of SIE. All events were adjudicated as unrelated to the Micra device or procedure. Bacteremia was documented to be related to a gram-positive organism in 13 events (seven Staphylococcus, three Streptococcus, two Enterococcus, and one uncharacterized gram-positive bacteria), and gram-negative organisms in three events. In five events, the type of organism was not characterized (two patients with endocarditis). No persistent cases of bacteremia after antibiotic cessation were seen over the duration of follow-up CONCLUSION: In this small series of Micra patients who developed SIEs postimplant, the occurrence of bacteremia and/or endocarditis did not appear to lead to persistent bacteremia off antibiotics; most events resolved with antibiotic treatment.


Assuntos
Bacteriemia/epidemiologia , Endocardite/epidemiologia , Marca-Passo Artificial/efeitos adversos , Infecções Relacionadas à Prótese/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Bacteriemia/etiologia , Estudos de Coortes , Endocardite/etiologia , Desenho de Equipamento , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Infecções Relacionadas à Prótese/etiologia , Resultado do Tratamento
11.
Pacing Clin Electrophysiol ; 37(7): 820-7, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24484075

RESUMO

BACKGROUND: Remote monitoring (RM) of defibrillators (implantable cardioverter defibrillators [ICDs]) and cardiac resynchronization therapy devices (CRTDs) has been shown to be cost effective, convenient, and associated with reduced mortality and a reduction in the time to physician intervention for actionable events. However, patient compliance with monitoring over time and what factors might influence such compliance have not been well described. This study sought to identify factors contributing to patient noncompliance with RM of ICDs and CRTDs in a large real-world population. METHODS: Deidentified data on U.S. patients enrolled in the Medtronic CareLink RM system were used to compare patients with no (noncompliant, n = 14,848) and with ≥ 2 RM transmissions (compliant, n = 103,284) during a 14-month period. RESULTS: Overall noncompliance with RM was 21%. Younger age (≤ 40), female sex, wanded device, Medicare Census Division, and small clinic size all predicted patient noncompliance (P < 0.01). Device type (ICD vs CRTD) did not (P = 0.52). Multivariate analysis suggested clinically important predictors of noncompliance to be: age ≤ 40, odds ratio (OR) 2.64 (95% confidence interval, 2.42-2.88); Medicare Census Division (Mountain vs West North Central), OR 2.15 (1.96-2.37); and small clinic size (1-4 vs >100 patients), OR 4.38 (3.92-4.91). CONCLUSIONS: There is room for improvement in RM usage among enrolled patients. Younger patients, smaller clinics, and certain geographic areas may be targets for research into interventions to further improve the use of RM.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Cooperação do Paciente/estatística & dados numéricos , Tecnologia de Sensoriamento Remoto , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
12.
J Med Econ ; 27(1): 62-68, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38084737

RESUMO

BACKGROUND: VAD therapy has revolutionized the treatment of end-stage heart failure, but infections remain an important complication. The objective of this study was to characterize the clinical and economic impacts of VAD-specific infections. METHODS: A retrospective analysis of a United States claims database identified members ≥ 18 years with a claim for a VAD implant procedure, at least 6 months of pre-implant baseline data, and 12 months of follow-up between 1 June 2016 and 31 December 2019. Cumulative incidence of infection was calculated. Infection and non-infection cohorts were compared regarding mortality, healthcare utilization, and total cost. Regression models were used to identify risk factors associated with infections and mortality. RESULTS: A total of 2,259 patients with a VAD implant were included, with 369 experiencing infection (12-month cumulative incidence 16.1%). Patients with infection were 2.1 times more likely to die (p < 0.001, 95% CI [1.5-2.9]). The mean 12-month total cost per US patient was $354,339 for the non-infection cohort and $397,546 for the infection cohort, a difference of $43,207 (p < 0.0001). CONCLUSIONS: VAD infections were associated with higher mortality, more healthcare utilization, and higher total cost. Strategies to minimize VAD-specific infections could lead to improved clinical and economic outcomes.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Estados Unidos/epidemiologia , Estudos Retrospectivos , Insuficiência Cardíaca/terapia , Coração Auxiliar/efeitos adversos , Revisão da Utilização de Seguros , Fatores de Risco , Resultado do Tratamento
13.
Cardiol J ; 2024 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-39136617

RESUMO

BACKGROUND: Cryoballoon ablation for treatment of atrial fibrillation (AF) reduces procedure times, but limited data is available about its impact on electrophysiology (EP) lab efficiency in Central and Eastern Europe (CEE). Using CEE-specific procedure data, the present study modeled cryoballoon ablation procedures on EP lab resource consumption to improve efficiency. METHODS: A discrete event simulation model was developed to assess EP efficiency with cryoballoon ablation. Model inputs were taken from CEE sites within the Cryo Global Registry, namely Czech Republic, Hungary, Poland, Serbia, and Slovakia. The main endpoints were percentage of days that resulted in overtime and percentage of days with time for one extra simple EP procedure. Use of the 'figure of 8' (Fo8) closure technique to reduce procedure time was also examined. RESULTS: The mean lab occupancy time across all CEE sites was 133 ± 47 minutes (min: 104 minutes, max:181 minutes). Cryoballoon ablation in the base-case scenario resulted in 14.6% of days with overtime and 64.8% of days with time for an extra simple EP procedure. Use of the Fo8 closure technique enhanced these values to 5.5% and 85.3%, respectively. Model endpoints were most sensitive to changes in lab occupancy times and overtime start time. CONCLUSIONS: In this CEE-specific analysis of EP lab efficiency it was found that 3 cryoballoon ablation procedures could be performed in 1 lab day, leaving time for a 4th simple EP procedure on most days. As such, use cryoballoon ablation for PVI is an effective way to improve EP lab efficiency.

14.
Medwave ; 24(8): e2918, 2024 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-39222517

RESUMO

Objective: Cryoballoon ablation for pulmonary vein isolation is a time-efficient procedure that can alleviate stress on electrophysiology lab resources. This analysis modeled the impact of cryoballoon ablation on electrophysiology lab operation using data from Latin America. Methods: Data from centers in Argentina, Mexico, Colombia, and Chile of the were used as inputs for an electrophysiology lab efficiency simulation model. The model used the assumption that either two (today's electrophysiology lab operations) or three (including electrophysiology lab operational changes) cryoballoon ablation procedures could be performed per day. The endpoints were the percentage of days that resulted in 1) overtime and 2) time left for an extra non-ablation electrophysiology procedure. Results: Data from a total of 232 procedures from six Latin American centers were included in the analysis. The average electrophysiology lab occupancy time for all procedures in Latin America was 132 ± 62 minutes. In the Current Scenario (two procedures per day), 7.4% of simulated days resulted in overtime, and 81.4% had enough time for an extra electrophysiology procedure. In the Enhanced Productivity Scenario (three procedures per day), 16.4% of days used overtime, while 67.4% allowed time for an extra non-ablation electrophysiology procedure. Conclusions: Using real-world, Latin American-specific data, we found that with operational changes, three ablation procedures could feasibly be performed daily, leaving time for an extra electrophysiology procedure on more than half of days. Thus, use of cryoballoon ablation is an effective tool to enhance electrophysiology lab efficiency in resource-constrained regions such as Latin America.


Objetivos: La ablación con criobalón para el aislamiento de venas pulmonares es un procedimiento que ahorra tiempo y puede ahorrar recursos del laboratorio de electrofisiología. Este análisis modeló el impacto de la ablación con criobalón en el funcionamiento del laboratorio de electrofisiología utilizando datos de América Latina. Métodos: Los datos de los centros de Argentina, México, Colombia y Chile del se utilizaron como datos de entrada para un modelo de simulación de la eficiencia del laboratorio de electrofisiología. El modelo partió del supuesto de que se podían realizar dos (operaciones actuales del laboratorio de electrofisiología) o tres (incluidos los cambios operativos del laboratorio de electrofisiología) procedimientos de ablación con criobalón por día. Los criterios de valoración eran el porcentaje de días en los que se producían 1) horas extraordinarias y 2) tiempo restante para un procedimiento electrofisiológico adicional no relacionado con la ablación. Resultados: Se incluyeron en el análisis los datos un total de 232 procedimientos de seis centros latinoamericanos. El tiempo medio de ocupación del laboratorio de electrofisiología para todos los procedimientos en Latinoamérica fue de 132 ± 62 minutos. En el escenario actual (dos procedimientos por día), el 7,4% de los días simulados resultaron en horas extras, y el 81,4% tuvo tiempo suficiente para un procedimiento de electrofisiología adicional. En el escenario de productividad mejorada (tres procedimientos por día), el 16,4% de los días utilizó horas extraordinarias, mientras que el 67,4% dispuso de tiempo suficiente para un procedimiento electrofisiológico extra sin ablación. Conclusiones: Utilizando datos del mundo real específicos de América Latina, descubrimos que, aplicando cambios operativos, es factible realizar tres procedimientos de ablación al día, lo que deja tiempo para un procedimiento de electrofisiología adicional en más de la mitad de los días. Por lo tanto, el uso de la ablación con criobalón es una herramienta eficaz para mejorar la eficiencia de los laboratorios de electrofisiología en regiones con recursos limitados como América Latina.


Assuntos
Fibrilação Atrial , Criocirurgia , Veias Pulmonares , Sistema de Registros , Humanos , Criocirurgia/métodos , Veias Pulmonares/cirurgia , Fibrilação Atrial/cirurgia , América Latina , Fatores de Tempo
15.
JACC Clin Electrophysiol ; 10(5): 916-926, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38520434

RESUMO

BACKGROUND: Past clinical trials have shown the benefit of implantable cardioverter-defibrillators (ICDs) for reducing sudden cardiac death in at-risk patients. However, heart failure management and ICD technology have changed since these trials were first published. An updated assessment of ICD mortality benefit is needed. OBJECTIVES: The purpose of this study was to compare mortality rates between patients with a primary prevention (PP) indication for an ICD who did or did not receive an ICD using a contemporary, real-world data set. METHODS: Data was obtained from a large electronic health record data set covering patients in the United States from 2012 through 2020 who had a PP indication for an ICD and survived at least 1-year postindication. RESULTS: A total of 25,296 patients were identified as having a PP indication for ICD implantation, of which 2,118 (8.4%) were treated with an ICD within a year. Treated patients were younger than nontreated patients (age 63.4 years vs 66.1 years) with a smaller proportion of women (25.0% vs 36.7%). After 4-to-1 propensity matching, treated patients had similar clinical characteristics to nontreated patients. A Cox proportional hazard model estimated a 24.3% lower risk of all-cause mortality in patients when treated vs not treated with an ICD (HR: 0.757; 95% CI: 0.678-0.835; P <0.001). There was no detectable difference in ICD benefit between patients with ischemic and nonischemic heart disease (P = 0.50). CONCLUSIONS: ICD treatment of patients with a PP indication is associated with improved mortality even in the context of evolving adjunctive HF treatment, consistent with earlier landmark trials.


Assuntos
Morte Súbita Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Prevenção Primária , Humanos , Desfibriladores Implantáveis/estatística & dados numéricos , Feminino , Masculino , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/terapia , Pessoa de Meia-Idade , Idoso , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/epidemiologia , Estados Unidos/epidemiologia , Estudos Retrospectivos
16.
PLoS One ; 17(11): e0277685, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36395168

RESUMO

Cost collection using UB-04 forms for economic evaluation is challenging, as UB-04 collection is time and effort intensive and compliance is imperfect. Alternative data sources could overcome those challenges. The objective of this study is to determine the usefulness of UB-04 data in estimating hospital costs compared to clinical case report form (CRF) data. Health care utilization costs were compared from financial information in UB-04s and from an assignment process using CRF data, from the WRAP-IT (23 infections) and the Micra IDE trials (61 adverse events and 108 implants). Charge-based costs were calculated by multiplying charges in UB-04s and hospital-specific Cost-to-Charge ratios from the Centers for Medicare and Medicaid Services cost reports. The cost assignment process used clinical information to find comparable encounters in real world data and assigned an average cost. Paired difference tests evaluated whether both methods yield similar results. The mean difference in total infection related costs between methods in the WRAP-IT trial was $152 +/-$22,565. In the Micra IDE trial, the mean difference in total adverse event related costs between methods was -$355 +/-$8,298 while the mean difference in total implant related costs between methods was $-3,488 +/-$13,859. Wilcoxon tests and generalized linear models could not reject the difference in costs between methods in the first two cases. Cost assignment methods achieve results similar to costs obtained through UB-04s, without the additional investment in time and effort. The use of UB-04 information for services that are not mature in a health care system may present unexpected challenges, necessitating a tradeoff with other methods of cost assignment.


Assuntos
Custos Hospitalares , Medicare , Estados Unidos , Preços Hospitalares , Análise Custo-Benefício
17.
J Cardiol ; 79(6): 734-739, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35016809

RESUMO

BACKGROUND: Automated optimization algorithm (AdaptivCRT; Medtronic, Mounds View, MN, USA) allowing automated optimization of cardiac resynchronization therapy (CRT), has been introduced. However, little is known concerning its cost-effectiveness. This study aims to evaluate the potential economic benefits of AdaptivCRT of CRT. METHODS: Markov modelling was informed by empirical data sourced from the AdaptivCRT Clinical Trial. Published meta-analyses were used to derive the impact of increasing response to hospitalization and mortality risks. Response was assessed via the clinical composite score. RESULTS: Deterministic results suggested a mean survival of 10.97 years with adaptive algorithms against 10.5 years without (+0.47 in favour of novel algorithms). Heart failure hospitalization costs were modelled to ¥1,382,753 (US $12,686) with novel devices against ¥1,524,747 (US $13,989) with previous technology models. Sensitivity analyses show CRT with Adaptive algorithm was projected to provide cost savings in all scenarios. CONCLUSIONS: The use of AdaptivCRT was projected to improve average patient survival and avoid costs in a Japanese healthcare setting.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Terapia de Ressincronização Cardíaca/métodos , Dispositivos de Terapia de Ressincronização Cardíaca , Análise Custo-Benefício , Insuficiência Cardíaca/terapia , Hospitalização , Humanos , Resultado do Tratamento
18.
JACC Clin Electrophysiol ; 8(1): 101-111, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34600848

RESUMO

OBJECTIVES: This study aimed to identify risk factors for infection after secondary cardiac implantable electronic device (CIED) procedures. BACKGROUND: Risk factors for CIED infection are not well defined and techniques to minimize infection lack supportive evidence. WRAP-IT (World-wide Randomized Antibiotic Envelope Infection Prevention trial), a large study that assessed the safety and efficacy of an antibacterial envelope for CIED infection reduction, offers insight into procedural details and infection prevention strategies. METHODS: This analysis included 2,803 control patients from the WRAP-IT trial who received standard preoperative antibiotics but not the envelope (44 patients with major infections through all follow-up). A multivariate least absolute shrinkage and selection operator machine learning model, controlling for patient characteristics and procedural variables, was used for risk factor selection and identification. Risk factors consistently retaining predictive value in the model (appeared >10 times) across 100 iterations of imputed data were deemed significant. RESULTS: Of the 81 variables screened, 17 were identified as risk factors with 6 being patient/device-related (nonmodifiable) and 11 begin procedure-related (potentially modifiable). Patient/device-related factors included higher number of previous CIED procedures, history of atrial arrhythmia, geography (outside North America and Europe), device type, and lower body mass index. Procedural factors associated with increased risk included longer procedure time, implant location (non-left pectoral subcutaneous), perioperative glycopeptide antibiotic versus nonglycopeptide, anticoagulant, and/or antiplatelet use, and capsulectomy. Factors associated with decreased risk of infection included chlorhexidine skin preparation and antibiotic pocket wash. CONCLUSIONS: In WRAP-IT patients, we observed that several procedural risk factors correlated with infection risk. These results can help guide infection prevention strategies to minimize infections associated with secondary CIED procedures.


Assuntos
Desfibriladores Implantáveis , Infecções Relacionadas à Prótese , Antibioticoprofilaxia , Desfibriladores Implantáveis/efeitos adversos , Eletrônica , Humanos , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/prevenção & controle , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Risco
19.
J Invasive Cardiol ; 33(7): E522-E530, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34224381

RESUMO

BACKGROUND: The volume of atrial fibrillation (AF) catheter ablation procedures has increased to address the growing patient population with AF; however, the impact of cryoballoon ablation on electrophysiology (EP) lab throughput is under-studied when treating patients with persistent AF (PsAF). OBJECTIVE: To assess EP lab utilization associated with cryoballoon ablation for the treatment of patients with PsAF and to evaluate mechanisms that optimize hospital resources. METHODS: Procedural data derived from the STOP Persistent AF trial were input into a discrete event simulation to assess EP lab utilization during AF ablation procedures. Patient and physician delays and lab occupancy times were modeled in a nominal and efficient EP lab setting over 1000 days. Accounting for variation in procedural times, we evaluated the number of days in which preplanned pulmonary vein isolation (PVI) cases resulted in overtime or excess time for non-ablation EP cases within a given lab day. A sensitivity analysis determined the parameters that most strongly influenced EP lab throughput. RESULTS: Lab occupancy times for the Nominal Use (NU) case included 165 procedures, and the High-Efficiency Use (HEU) case was derived from 69 procedures conducted at sites with faster procedure times than average. The HEU case had shorter lab occupancy times than the NU case (158 ± 32 minutes vs 188 ± 51 minutes, respectively). In the NU case, a total of 2000 procedures were conducted, with 28 lab days (2.8%) extending into overtime and 900 lab days (90%) exhibiting excess time for a non-ablation EP case. In the HEU case, a total of 3000 procedures were conducted, with 87 lab days (8.7%) extending into overtime and 635 lab days (63.5%) exhibiting excess time for a non-ablation EP case. The model was most sensitive to lab occupancy duration and the time of day that overtime started. CONCLUSIONS: Cryoballoon ablation for the treatment of patients with PsAF confers EP lab efficiencies that can support 3 PVI cases in a lab day.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Eletrofisiologia , Seguimentos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
20.
J Med Econ ; 24(1): 173-180, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33471579

RESUMO

OBJECTIVE: The mortality benefit of implantable cardioverter defibrillators (ICDs) for primary prevention (PP) of sudden cardiac arrest (SCA) has been well-established, but ICD therapy remains globally underutilized. The results of the Improve SCA study showed a 49% relative risk reduction in all-cause mortality among ICD patients with 1.5 primary prevention (1.5PP) characteristics (patients with one or more risk factors, p < 0.0001). We evaluated the cost-effectiveness of ICD compared to no ICD therapy among patients with 1.5PP characteristics in three Latin American countries and analyzed the factors involved in cost-effectiveness. METHODS: We used a published Markov model that compares costs and outcomes of ICD to no ICD therapy from local payers' perspective and included country-specific and disease-specific inputs from the Improve SCA study and current literature. We used WHO-recommended willingness-to-pay (WTP) thresholds to assess cost-effectiveness and compared model outcomes between countries. RESULTS: Incremental costs per QALY (quality-adjusted life year) saved by ICD compared to no ICD therapy are Colombian Pesos COP$46,729,026 in Colombia, Mexican Pesos MXN$246,016 in Mexico, and Uruguayan Pesos UYU$1,213,614 in Uruguay in the base case scenario; all three figures are between 1-3-times GDP per capita for each country. One-way and probabilistic sensitivity analyses confirm the base case scenario results. Non-cardiac accumulated deaths are lower in Mexico, resulting in a comparatively increased cost-effective ICD therapy. LIMITATIONS: The Improve SCA study was not randomized, so clinical results could be biased; however, measures were taken to reduce this bias. Costs and benefits were modelled beyond the timeline of direct observation in the Improve SCA study. CONCLUSIONS: ICD therapy is cost-effective in Mexico and Uruguay and potentially cost-effective in Colombia for a 1.5PP population. Variability in ICER estimates by country can be explained by differences in non-cardiac deaths and cost inputs.


Assuntos
Desfibriladores Implantáveis , Análise Custo-Benefício , Morte Súbita Cardíaca/prevenção & controle , Humanos , América Latina , Prevenção Primária , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA