Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Circ J ; 84(2): 178-185, 2020 01 24.
Artigo em Inglês | MEDLINE | ID: mdl-31941850

RESUMO

BACKGROUND: The risks of ventricular fibrillation (Vfib) associated with frequency-domain optical coherence tomography (OCT)/optical frequency domain imaging (OFDI) remain undetermined.Methods and Results:We retrospectively studied the occurrence of Vfib during OCT/OFDI for unselected indications. The frequency of Vfib and patient and procedural characteristics were investigated. A total of 4,467 OCT/OFDI pullback examinations were performed in 1,754 patients (median of 2.0 [2.0-3.0] pullbacks for 1.0 [1.0-1.3] vessels). OCT/OFDI was performed during PCI in 899 patients (51.3%). The contrast injection volume per pullback was 14.4 (11.7-17.2) mL with a flow rate of 3.4 (3.2-3.5) mL/s. Vfib occurred in 31 pullbacks (0.69%) in 30 patients (1.7%). No cases of Vfib occurred when using low-molecular-weight dextran. On multivariate analysis, contrast volume was the only independent factor for predicting Vfib (odds ratio, 1.080; 95% confidence interval, 1.008-1.158, P=0.029). The best cutoff value of contrast volume for predicting Vfib was 19.2 mL (area under the curve, 0.713, P<0.001; diagnostic accuracy, 87.1%). CONCLUSIONS: The present large, single-center registry study indicated that Vfib during OCT/OFDI was rare for unselected indications. Contrast injection volume used to displace blood should be limited to avoid Vfib.


Assuntos
Meios de Contraste/efeitos adversos , Vasos Coronários/diagnóstico por imagem , Frequência Cardíaca , Iopamidol/efeitos adversos , Tomografia de Coerência Óptica/efeitos adversos , Fibrilação Ventricular/epidemiologia , Idoso , Meios de Contraste/administração & dosagem , Feminino , Humanos , Incidência , Injeções , Iopamidol/administração & dosagem , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/fisiopatologia
2.
J Artif Organs ; 22(3): 194-199, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30968273

RESUMO

The ideal blood-salvaging strategies for off-pump coronary artery bypass graft procedures have not been determined. We developed a new blood-salvaging system that uses a cardiotomy suction. The purpose of this study was to examine the efficacy of this novel method. This was a retrospective study involving 50 consecutive patients undergoing off-pump coronary artery bypass grafting. In 25 patients, a simple cardiotomy suction system was used (cardiotomy suction group). These individuals were compared with 25 historical cohorts who were treating with the conventional cell saver system (cell saver group). There was no in-hospital mortality in either group. In the cell saver group, there was one major complication (stroke) and two minor complications (saphenous vein graft occlusion, superficial wound infection). In the cardiotomy suction group, there was one minor complication (subclinical pulmonary emboli). The cardiotomy suction group received significantly fewer transfused RBC (cardiotomy: 0.56 ± 1.4 units vs. cell saver: 2.46 ± 3.3 units, p = 0.005). The serum total protein and albumin levels were significantly higher in the cardiotomy group. Our newly developed simple cardiotomy suction system, when compared with the conventional cell saver system, produced similar clinical results and attenuated postoperative hemodilution. Our system may emerge as a preferable alternative for blood salvage during off-pump coronary artery bypass grafting.


Assuntos
Ponte de Artéria Coronária sem Circulação Extracorpórea/métodos , Recuperação de Sangue Operatório/métodos , Sucção/métodos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sucção/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA