Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 35(2): 278-287, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38073051

RESUMO

INTRODUCTION: Transvenous lead extraction (TLE), while mostly a safe procedure, has risk of serious periprocedural complications. As such, overnight hospitalization remains a routine practice. In our center, we routinely discharge patients on the same day following an uncomplicated TLE. METHODS: This is a retrospective study of 265 consecutive patients who underwent uncomplicated TLE in our center between 2019 and 2021. Same-day discharge (SDD) patients are compared with those who stayed at least overnight for observation after the TLE procedure (non-SDD group). To assess the safety of an SDD strategy after uncomplicated TLE, the main study endpoint was to compare the rate of major procedure-related complications at 1-, 7-, and 30-days. To identify the factors influencing the operator's decision to discharge the patient on the same day, the secondary endpoint was to analyze clinical and procedural predictors of SDD. RESULTS: A total of 153 patients were discharged the same day after uncomplicated TLE (SDD), while 112 stayed at least overnight after the procedure (non-SDD). There was no significant difference in major procedure-related complications at 1-day (SDD 0% vs. non-SDD 1.8%, p value = ns), while patients in the SDD group had a lower rate of 7- and 30-day complications when compared with those in the non-SDD group (2.1% vs. 8.2%, p value = .0308; and 3.5% vs. 16%, p value = .0049, respectively). Noninfectious indication for TLE (OR 16.1, 95% confidence interval [CI] 4.29-77.6) and procedure end time before 12:00 (OR 2.82, 95% CI 1.11-7.27) were the only independent predictors of SDD. CONCLUSION: SDD discharge following uncomplicated TLE in selected patients (i.e., those without device infection and when the TLE procedure is completed in the morning) is feasible and safe.


Assuntos
Hospitalização , Alta do Paciente , Humanos , Remoção de Dispositivo , Estudos de Viabilidade , Estudos Retrospectivos , Resultado do Tratamento
2.
J Cardiovasc Electrophysiol ; 34(2): 348-355, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36448428

RESUMO

INTRODUCTION: Early and safe ambulation can facilitate same-day discharge (SDD) following catheter ablation, which can reduce resource utilization and healthcare costs and improve patient satisfaction. This study evaluated procedure success and safety of the VASCADE MVP venous vascular closure system in patients with atrial fibrillation (AF). METHODS: The AMBULATE SDD Registry is a two-stage series of postmarket studies in patients with paroxysmal or persistent AF undergoing catheter ablation followed by femoral venous access-site closure with VASCADE MVP. Efficacy endpoints included SDD success, defined as the proportion of patients discharged the same day who did not require next-day hospital intervention for procedure/access site-related complications, and access site sustained success within 15 days of the procedure. RESULTS: Overall, 354 patients were included in the pooled study population, 151 (42.7%) treated for paroxysmal AF and 203 (57.3%) for persistent AF. SDD was achieved in 323 patients (91.2%) and, of these, 320 (99.1%) did not require subsequent hospital intervention based on all study performance outcomes. Nearly all patients (350 of 354; 98.9%) achieved total study success, with no subsequent hospital intervention required. No major access-site complications were recorded. Patients who had SDD were more likely to report procedure satisfaction than patients who stayed overnight. CONCLUSION: In this study, 99.7% of patients achieving SDD required no additional hospital intervention for access site-related complications during follow-up. SDD appears feasible and safe for eligible patients after catheter ablation for paroxysmal or persistent AF in which the VASCADE MVP is used for venous access-site closure.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Alta do Paciente , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Satisfação do Paciente , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Sistema de Registros , Resultado do Tratamento
3.
J Cardiovasc Electrophysiol ; 32(10): 2781-2784, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34411376

RESUMO

INTRODUCTION: Watchman FLX has been recently approved for left atrial appendage occlusion (LAAO) in the US. Intracardiac echocardiography (ICE) - which is already commonly used to guide trans-septal access - can serve as an alternative to TEE, simplifying the procedure and reducing associated costs. Herein, we report our experience with ICE-guided LAAO with Watchman FLX. METHODS AND RESULTS: This cohort study included the first 190 consecutive patients who underwent LAAO with Watchman FLX in our center. LAAO was successful in all patients without significant peri-procedural, device-related complications in either group. Compared to TEE, we observed a significant reduction in procedural times when using ICE. In addition, there was a potentially clinically relevant reduction in fluoroscopy dose, mainly secondary to fewer cine acquisition runs. At follow-up, no cases of device embolism were noted, whereas the rate of device-related thrombosis and peri-device leaks were comparable between groups. CONCLUSION: ICE-guided LAAO with Watchman FLX is safe and feasible, with a significant reduction in procedural time and potential reduction in fluoroscopy dose when compared to TEE.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/efeitos adversos , Estudos de Coortes , Ecocardiografia Transesofagiana , Humanos , Resultado do Tratamento , Ultrassonografia de Intervenção
4.
J Cardiovasc Electrophysiol ; 32(4): 973-981, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33442937

RESUMO

BACKGROUND: The creation of effective and permanent lesions is a crucial factor in determining the success rate of atrial fibrillation (AF) ablation. By increasing the efficacy of radiofrequency (RF) energy-mediated lesion formation, half-normal saline (HNS) as an irrigant for open-irrigated ablation catheters has the potential to reduce procedural times and improve acute and long-term outcomes. METHODS: This is a double-blind randomized clinical trial of 99 patients undergoing first-time RF catheter ablation for AF. Patients enrolled were randomly assigned in a 1:1 fashion to perform ablation using HNS or normal saline (NS) as an irrigant for the ablation catheter. RESULTS: The use of HNS is associated with shorter RF times (26 vs. 33 min; p = .02) with comparable procedure times (104 vs. 104 min). The rate of acute pulmonary vein reconnections (16% vs. 18%) was comparable, with a median of 1 vein reconnection in the HNS arm versus 2 in the NS arm. There was no difference in procedure-related complications, including the incidence of postprocedural hyponatremia when using HNS. Over the 1-year follow-up, there is no significant difference between the HNS and NS with respect to the recurrence of any atrial arrhythmia (off antiarrhythmic drugs [AAD]: 47% vs. 52%; hazard ratio [HR]: 1.17, 95% confidence interval [CI]: 0.66-2.06; off/on AAD: 66% vs. 66%, HR: 1.06, 95% CI: 0.53-2.12), with a potential benefit of using HNS when considering the paroxysmal AF cohort (on/off AAD 73% vs. 62%, HR: 0.72, 95% CI: 0.19-2.70). CONCLUSIONS: In a mixed cohort of patients undergoing first-time AF ablation, irrigation of open-irrigated RF ablation catheters with HNS is associated with shorter RF times, with a comparably low rate of procedure-related complications. In the long term, there is no significant difference with respect to the recurrence of any atrial arrhythmia. Larger studies with a more homogeneous population are necessary to determine whether HNS improves clinical outcomes.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Catéteres , Desenho de Equipamento , Humanos , Veias Pulmonares/cirurgia , Recidiva , Solução Salina , Resultado do Tratamento
5.
J Cardiovasc Electrophysiol ; 30(4): 511-516, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30623500

RESUMO

INTRODUCTION: Electrical isolation of the left atrial appendage (LAA) is an important adjunctive ablation strategy in patients with nonparoxysmal atrial fibrillation (AF). Patients who have impaired LAA contractility following isolation may require long-term oral anticoagulant (OAC) therapy irrespective of their CHADS2 -VASc score. Percutaneous LAA occlusion (LAAO) is a potential alternative to life-long OAC therapy. We aimed to assess the rate of OAC discontinuation and thromboembolic (TE) events following percutaneous LAAO in patients who underwent LAA electrical isolation (LAAI). METHODS: This is a retrospective two-center study of patients who underwent percutaneous LAAO following LAAI. Patients with at least 3-month follow-up were included in the study. The antithrombotic therapy and TE events at the time of the last follow-up were noted. RESULTS: The LAA was successfully occluded in 162 (with Watchman device in 140 [86.4%] and Lariat in 22 [13.6%]). A total of 32 patients had leaks detected on the 45-day transesophageal echocardiogram (TEE); 21 (15%) Watchman and 11 (50%) Lariat cases (P = 0.0001). Two (one Watchman and one Lariat) of the 32 leaks were more than 5 mm. After the 45-day TEE, 150 (92.6%) patients were off-OAC. No TE events were reported in the 150 patients who stopped the anticoagulants. Four (2.47%) patients experienced stroke following the LAAO (three Watchman and one Lariat) procedure while on-OAC, two of which were fatal. At the median follow-up of 18.5 months, 159 (98.15%) patients were off-anticoagulant. CONCLUSION: Up to 98% of patients with LAAI could safely discontinue OAC after undergoing the appendage closure procedure.


Assuntos
Anticoagulantes/administração & dosagem , Apêndice Atrial/efeitos dos fármacos , Fibrilação Atrial/terapia , Cateterismo Cardíaco , Ablação por Cateter , Acidente Vascular Cerebral/prevenção & controle , Tromboembolia/prevenção & controle , Idoso , Anticoagulantes/efeitos adversos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/mortalidade , Fibrilação Atrial/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Ablação por Cateter/efeitos adversos , Ablação por Cateter/mortalidade , Esquema de Medicação , Ecocardiografia Doppler em Cores , Ecocardiografia Transesofagiana , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/mortalidade , Acidente Vascular Cerebral/fisiopatologia , Tromboembolia/diagnóstico , Tromboembolia/mortalidade , Tromboembolia/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
6.
Am Heart J ; 205: 145-148, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30144981

RESUMO

The objective of this study was to evaluate the long-term efficacy of FIRM ablation with PVAI vs PVAI plus posterior wall isolation (PWI) and non-PV trigger ablation in persistent (PeAF) and long-standing persistent AF (LSPAF) patients. The procedure time was recorded to be 180.6 ±â€¯35.9 and 124.03 ±â€¯45.4 minutes in the FIRM+PVI and PVI + PWI + non-PV trigger ablation group respectively. At 24-month follow-up, 24% (95% CI 8.7%-37.8%) in the FIRM-ablation group and 48% (95% CI 27.6-63.3%) in the non-PV trigger ablation group remained arrhythmia-free off-antiarrhythmic drugs after a single procedure. Clinical Trial Registration:ClinicalTrials.gov (Identifier: NCT02533843).


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Frequência Cardíaca/fisiologia , Idoso , Fibrilação Atrial/fisiopatologia , Mapeamento Potencial de Superfície Corporal , Eletrocardiografia Ambulatorial , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Tempo , Resultado do Tratamento
7.
Europace ; 20(9): e124-e132, 2018 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-29016788

RESUMO

Aims: Superior vena cava (SVC) isolation might be difficult to achieve because of the vicinity of the phrenic nerve (PN) and sinus node. Based on its embryogenesis, we hypothesized the presence of preferential conduction from the right atrial (RA) posterior wall, making it possible to isolate the SVC antrally, sparing its anterior and lateral aspect. Methods and results: This is a descriptive cohort study of 105 consecutive patients in which SVC isolation was obtained with radiofrequency ablation, starting in the septal aspect of the SVC-RA junction and continued posteriorly and inferiorly targeting sites of early activation until electrical isolation was obtained. Acute SVC isolation was achieved in 103 (98%) patients; the mean distance between the site of SVC isolation and the SVC-RA junction was 19.9 ± 5.3 (range 9.7-33.7) mm. During follow-up, 2 (2%) patients developed symptomatic diaphragmatic paralysis due to transient right PN injury; 13 patients underwent a repeat ablation: SVC reconnection was observed in 5 patients, and re-isolation was easily achieved by targeting the corresponding sites of early activation. Conclusion: Superior vena cava isolation can be completed by targeting its septal segment and sites of early activation in the posterior SVC-RA junction and RA posterior wall; this is a feasible alternative ablation strategy in patients in which SVC isolation cannot be completed with the standard approach. The risk of sinus node injury or SVC stenosis are eliminated; PN injury is still possible but can easily be prevented with high-output pacing to exclude a true posterior course of the PN.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Átrios do Coração/cirurgia , Veia Cava Superior/cirurgia , Idoso , Estudos de Coortes , Feminino , Humanos , Complicações Intraoperatórias/epidemiologia , Masculino , Pessoa de Meia-Idade , Traumatismos dos Nervos Periféricos/epidemiologia , Nervo Frênico/lesões , Estudos Prospectivos , Ablação por Radiofrequência/métodos
8.
J Cardiovasc Electrophysiol ; 27(4): 399-403, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26756289

RESUMO

INTRODUCTION: Because of the absence of a dedicated reversal agent, the outcome of pericardial effusion (PE) following procedures performed with uninterrupted apixaban or rivaroxaban is unknown. We report the characteristics of PEs presenting with tamponade in patients undergoing AF ablation with uninterrupted factor Xa inhibition (FXaI) to understand their management and prognosis. METHODS AND RESULTS: We performed a multicenter cross-sectional survey in 10 centers across the United States. Patient data were obtained by chart review. In all patients the procedure was performed with uninterrupted FXaI. A total of 16 PEs requiring intervention were reported from 5 centers. Two patients were on apixaban 5 mg BD, the remaining on rivaroxaban 20 mg OD. Eleven PEs occurred in the periprocedural setting, and 5 PEs occurred from 1 to 28 days after the procedure. Pericardiocentesis and drainage were performed in all cases. Protamine and 4-factor prothrombin complex concentrate (4F-PCC) were given in all periprocedural cases. Two patients required surgery: in one case coagulation of the pericardial blood prevented effective drainage, and in the other bleeding was secondary to a steam pop-induced atrial tear. None of the postprocedural cases required FXaI reversal and the dose of rivaroxaban was temporarily reduced. No fatal outcomes or thromboembolic events were reported. CONCLUSION: Pericardiocentesis and drainage with FXaI reversal proved effective in the management of acute PEs with tamponade occurring periprocedurally in patients undergoing AF ablation with uninterrupted FXaI. Early postprocedural effusions can be treated with pericardiocentesis without the need of a reversal agent.


Assuntos
Fibrilação Atrial/cirurgia , Oclusão com Balão/métodos , Ablação por Cateter/efeitos adversos , Inibidores do Fator Xa/administração & dosagem , Derrame Pericárdico/prevenção & controle , Tromboembolia/prevenção & controle , Idoso , Anticoagulantes/administração & dosagem , Fibrilação Atrial/complicações , Estudos Transversais , Relação Dose-Resposta a Droga , Esquema de Medicação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Derrame Pericárdico/etiologia , Complicações Pós-Operatórias/prevenção & controle , Pré-Medicação/métodos , Prognóstico , Tromboembolia/etiologia , Resultado do Tratamento , Estados Unidos
9.
J Cardiovasc Electrophysiol ; 26(8): 819-825, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25884325

RESUMO

BACKGROUND: This study examined incidence of AF following cavotricuspid isthmus (CTI) ablation alone or CTI plus prophylactic pulmonary vein isolation (PVI) in patients presenting with isolated atrial flutter (AFL) with no history of AF. METHODS AND RESULTS: We enrolled 216 patients with isolated typical atrial flutter and randomized them to CTI alone (group 1, n = 108, 61.2 ± 9.7 year, 75% male) or CTI+PVI ablation (group 2, n = 108, 62.4 ± 9.3 year, 73% male). Insertible loop recorder (ILR) was implanted in 21 and 19 patients from groups 1 and 2, respectively. Remaining patients were monitored with event recorders, ECG, 7-day Holter. Follow-up period was for 18 ± 6 months. Compared to group 1, group 2 had significantly longer procedural duration (75.9 ± 33 min vs. 161 ± 48 min [P < 0.001]) and fluoroscopy time (15.9 ± 12.3 min vs. 56.4+21 min [P < 0.001]). At the end of follow-up, 65 (60.2%) in group 1 and 77 (71.3%) in group 2 were arrhythmia free off-AAD (log-rank P = 0.044). A subgroup analysis was performed with 55 year age cut-off. In the <55 age group the CTI only population had similar success as in CTI+PVI, (21 of 24 [83.3%] vs. 19 of 22 [86.4%], respectively, log-rank P = 0.74). In the ≥55 group, having CTI+PVI showed significantly higher success compared to CTI only; 45 of 84 (53.6%) were AF/AT free in CTI only group versus 58 of 86 (67.4%) with CTI+PVI (log-rank P = 0.029). CONCLUSION: Prophylactic PVI reduced new-onset AF in patients with lone atrial flutter.


Assuntos
Fibrilação Atrial/prevenção & controle , Flutter Atrial/cirurgia , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/fisiopatologia , Flutter Atrial/diagnóstico , Flutter Atrial/epidemiologia , Flutter Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Intervalo Livre de Doença , Eletrocardiografia Ambulatorial , Feminino , Frequência Cardíaca , Humanos , Incidência , Itália/epidemiologia , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Modelos de Riscos Proporcionais , Veias Pulmonares/fisiopatologia , Fatores de Risco , Telemetria , Fatores de Tempo , Resultado do Tratamento , Estados Unidos/epidemiologia
10.
J Cardiovasc Electrophysiol ; 25(6): 579-84, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25013875

RESUMO

INTRODUCTION: Atrioesophageal fistula (AEF) is a rare but devastating complication of radiofrequency catheter ablation (RFCA) of atrial fibrillation (AF). Surgical repair and esophageal stents are available treatment options for AEF. We report outcomes of these 2 management strategies. METHODS: Nine patients with AEF post-RFCA for AF were included in this study. AEF was diagnosed based on symptoms and chest CT imaging. Of the 9 patients, 5 received stents and 4 underwent surgical repair of fistula. RESULTS: AF ablation was performed under general anesthesia (n = 4) or conscious sedation (n = 5). During ablation, RF power was maintained between 25 and 35 Watts in areas close to the esophagus and energy delivery discontinued when esophageal temperature reached 38 °C. Seven patients underwent ablation with 3.5-mm open-irrigated catheter, 1 with 8-mm nonirrigated catheter, and 1 had surgical epicardial ablation. Seven patients received proton pump inhibitor and sucralfate before and after procedure. AEF symptoms developed within 2­6 weeks from ablation. Esophageal stenting was performed in 5 patients (median age 58 years, median time from RFCA 4 weeks) and 4 underwent surgical repair (median age 54 years, median time from RFCA 4 weeks) within 2­4 hours from diagnosis. All 5 patients receiving stents died within 1 week of the procedure due to cerebral embolism, septic shock, or respiratory failure. On the other hand, the 4 patients that received surgical repair were alive at median follow-up of 2.1 years (P = 0.005). CONCLUSIONS: Esophageal stenting should be discouraged and prompt surgical repair is crucial for survival in patients with atrioesophageal fistula.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Fístula Esofágica/etiologia , Átrios do Coração/lesões , Complicações Pós-Operatórias/etiologia , Stents , Adulto , Fibrilação Atrial/diagnóstico , Estudos de Coortes , Fístula Esofágica/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico , Resultado do Tratamento
11.
J Cardiovasc Electrophysiol ; 25(10): 1057-64, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24903064

RESUMO

BACKGROUND: Impact of catheter ablation on exercise performance, quality of life (QoL) and symptom perception in asymptomatic longstanding persistent AF (LSP-AF) patients has not been reported yet. METHODS AND RESULTS: Sixty-one consecutive patients (mean age 62 ±13 years, 71% males) with asymptomatic LSP-AF undergoing first catheter ablation were enrolled. Extended pulmonary vein antrum isolation plus ablation of complex fractionated atrial electrograms and nonpulmonary vein triggers was performed in all. QoL survey was taken at baseline and 12-months postablation, using Short Form-36 (SF-36). Information on arrhythmia perception was obtained using a standard questionnaire and corroborating symptoms with documented evidence of arrhythmia. Exercise tests were performed on 38 patients at baseline and 5 months after procedure. Recurrence was assessed using event recorder, cardiology evaluation, electrocardiogram, and 7-day holter monitoring. After 20 ± 5 months follow-up, 36 (57%) patients remained recurrence-free off-AAD. Of the 25 patients experiencing recurrence, 21 (84%) were symptomatic. Compared to baseline, follow-up SF-36 scores improved significantly in many measures. For patients with successful ablation, physical component summary (PCS) and mental component summary (MCS) demonstrated substantial improvement ( MCS: 64.2 ± 22.3 to 70.1 ± 18.6 [P = 0.041]; PCS: 62.6 ± 18.4 to 70.0 ± 14.4 [P = 0.032]). Postablation exercise study in recurrence-free patients showed significant reduction in resting and peak heart rate (75 ± 11 vs. 90 ± 17 and 132 ± 20 vs. 154.5 ± 36, respectively, P < 0.001), increase in peak oxygen pulse (13.4 ± 3 vs. 18.9 ± 16 mL/beat, Δ5.5 ± 15, P = 0.001), peak VO2 /kg (19.7 ± 5 to 23.4 ± 13 mL/kg/min [Δ 3.7 ± 10, P = 0.043]), and corresponding MET (5.6 ± 1 to 6.7 ± 4 [Δ1.1 ± 3, P = 0.03]). No improvement was observed in patients with failed procedures. CONCLUSION: Successful ablation improves exercise performance and QoL in asymptomatic LSP-AF patients.


Assuntos
Fibrilação Atrial/epidemiologia , Fibrilação Atrial/psicologia , Ablação por Cateter/psicologia , Ablação por Cateter/normas , Teste de Esforço/estatística & dados numéricos , Satisfação do Paciente/estatística & dados numéricos , Qualidade de Vida/psicologia , Fibrilação Atrial/diagnóstico , Atitude Frente a Saúde , Doença Crônica , Intervalo Livre de Doença , Teste de Esforço/psicologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Fatores de Risco , Texas/epidemiologia , Resultado do Tratamento
12.
J Cardiovasc Electrophysiol ; 25(9): 930-938, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24903158

RESUMO

INTRODUCTION: Metabolic syndrome (MS) and obstructive sleep apnea (OSA) are well-known independent risk factors for atrial fibrillation (AF) recurrence. This study evaluated ablation outcome in AF patients with coexistent MS and OSA and influence of lifestyle modifications (LSM) on arrhythmia recurrence. METHODS AND RESULTS: We included 1,257 AF patients undergoing first catheter ablation (30% paroxysmal AF). Patients having MS + OSA were classified into Group 1 (n = 126; 64 ± 8 years; 76% male). Group 2 (n = 1,131; 62 ± 11 years; 72% male) included those with either MS (n = 431) or OSA (n = 112; no CPAP users) or neither of these comorbidities (n = 588). Patients experiencing recurrence after first procedure were divided into 2 subgroups; those having sporadic events (frequency < 2 months) remained on previously ineffective antiarrhythmic drugs (AAD) and aggressive LSM, while those with persistent arrhythmia (incessant or ≥2 months) underwent repeat ablation. After 34 ± 8 months of first procedure, 66 (52%) in Group 1 and 386 (34%) in Group 2 had recurrence (P < 0.001). Recurrence rate in only-MS, only-OSA, and without MS/OSA groups were 40%, 38%, and 29%, respectively. Patients with MS + OSA experienced substantially higher recurrence compared to those with lone MS or OSA (52% vs. 40% vs. 38%; P = 0.036). Of the 452 patients having recurrence, 250 underwent redo-ablation and 194 remained on AAD and LSM. At 20 ± 6 months, 76% of the redo group remained arrhythmia-free off AAD whereas 74% of the LSM group were free from recurrence (P = 0.71), 33% of which were off AAD. CONCLUSIONS: MS and OSA have additive negative effect on arrhythmia recurrence following single procedure. Repeat ablation or compliant LSM increase freedom from recurrent AF.


Assuntos
Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Ablação por Cateter , Estilo de Vida , Síndrome Metabólica/complicações , Apneia Obstrutiva do Sono/complicações , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recidiva , Reoperação , Fatores de Tempo , Resultado do Tratamento
13.
Pacing Clin Electrophysiol ; 37(10): 1297-305, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25195955

RESUMO

BACKGROUND: Preprocedural multidetector computed tomography (MDCT) may identify patients at risk for mechanical complications during lead extraction. METHODS: To describe the use and feasibility of computed tomography scanning for preprocedural planning of lead extraction, we conducted a retrospective study of high-risk patients, who underwent electrocardiogram (ECG)-gated MDCT before planned lead extraction between January 1, 2012, and March 30, 2013. RESULTS: Among 30 patients the mean age was 63 ± 15 years, 60% were male, and 20% had prior sternotomy. Most devices were left sided (93%) and 24 had implantable defibrillators (80%). Indications for extraction included lead malfunction (n = 15; 50%), class I lead advisories (n = 11; 37%), and infection (n = 10; 33%). Overall, there were 65 leads extracted (mean 2.1 leads per patient). One extraction procedure was deferred due to MDCT evidence of significant myocardial perforation with the lead tip > 1 cm beyond the epicardium (n = 1, 3%). MDCT suggestion of lead adherence to central venous structures (n = 13, 43%) was associated with significantly longer laser times (88 ± 71 seconds vs 30 ± 37 seconds, P = 0.02) and larger sheath size (14.9 ± 1.3 vs 13.5 ± 1.2 French, P = 0.02). MDCT evidence of central venous occlusion or stenosis was not associated with increased laser times. Excluding the patient with MDCT evidence of significant perforation, clinical success was achieved in all patients (n = 29/29). CONCLUSIONS: ECG-gated MDCT scanning before lead extraction may facilitate the identification of significant perforation and patients at high risk for mechanical complication.


Assuntos
Remoção de Dispositivo/efeitos adversos , Eletrocardiografia , Complicações Intraoperatórias/etiologia , Complicações Intraoperatórias/prevenção & controle , Tomografia Computadorizada Multidetectores , Cuidados Pré-Operatórios , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
14.
Pacing Clin Electrophysiol ; 36(3): 372-80, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23305443

RESUMO

INTRODUCTION: Patients with congenital heart disease (CHD) and implanted cardiac rhythm management devices have a high rate of endocardial lead issues requiring lead extraction. Laser lead extraction (LLE) is a promising modality for lead management though few studies have evaluated this technique in CHD. METHODS: This is a retrospective, case-controlled (gender- and age-matched, without CHD) analysis of all CHD patients from 2002-2010 at a single institution who underwent LLE as a primary extraction modality. The aim is to evaluate the utility of LLE in patients with CHD compared with controls without CHD. The primary outcome is LLE clinical success. Secondary outcomes include procedural success, complications, and factors related to LLE failure. RESULTS: Twenty-two patients with CHD underwent 24 LLE procedures to extract 35 leads. These were compared with 22 patients without CHD who underwent 24 LLE procedures to extract 37 leads. LLE clinical success was achieved for 26 of 35 leads (74%) in patients with CHD versus 35 of 37 leads (92%) in patients without CHD [P = 0.02]. No factors within the CHD group predicted LLE failure. Six of the nine leads for which LLE was unsuccessful were extracted using other methods. No complications were observed in the CHD group. CONCLUSIONS: Patients with CHD are less likely to have successful LLE than gender- and age-matched controls without CHD. LLE failures in CHD may be related to calcified adhesions. Mechanical-rotational devices and the femoral snare technique are useful for LLE failures. LLE provides an effective first-line approach for patients with CHD.


Assuntos
Remoção de Dispositivo/métodos , Cardiopatias Congênitas/terapia , Cardiopatias/congênito , Cardiopatias/terapia , Terapia a Laser , Marca-Passo Artificial , Adolescente , Adulto , Estudos de Casos e Controles , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
15.
J Cardiovasc Electrophysiol ; 23(8): 820-6, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22509886

RESUMO

INTRODUCTION: The Hansen Robotic system has been utilized in ablation procedures for atrial fibrillation (AF). However, because of the lack of tactile feedback and the rigidity of the robotic sheath, this approach could result in higher risk of complications. This worldwide survey reports a multicenter experience on the methodology, efficacy, and safety of the Hansen system in AF ablations. METHODS AND RESULTS: A questionnaire addressing questions on patient's demographics, procedural parameters, ablation success rate and safety information was sent to all centers where more than 50 robotic AF ablation cases have been performed. From June 2007 to December 2009, 1,728 procedures were performed at 12 centers utilizing the Hansen robotic navigation technology. The overall complication rate was 4.7% and the success rate was 67.1% after 18 ± 4 months of follow-up. In 5 low volume centers there appeared to be a learning curve of about 50 cases (complication rate 11.2% for the first 50 cases vs 3.7% for the 51-100 cases; P = 0.044) and a trend showing a decrease of complication rate with increasing case volume. However, in the remaining 7 centers no learning curve was present and the complication rate was stable over time (3.7% for the first 50 cases vs 3.6% for the 51st case thereafter; P = 0.942). CONCLUSION: The Hansen robotic system can be used for AF ablation safely. In low volume centers, there appeared to be a learning curve of the first 50 cases after which the complication rate decreased. With a higher case volume, the success rate increased.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/estatística & dados numéricos , Segurança do Paciente/estatística & dados numéricos , Padrões de Prática Médica/estatística & dados numéricos , Robótica/estatística & dados numéricos , Cirurgia Assistida por Computador/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Ablação por Cateter/efeitos adversos , Ablação por Cateter/instrumentação , Competência Clínica/estatística & dados numéricos , Desenho de Equipamento , Feminino , Pesquisas sobre Atenção à Saúde , Hospitais com Alto Volume de Atendimentos/estatística & dados numéricos , Humanos , Curva de Aprendizado , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Robótica/instrumentação , Cirurgia Assistida por Computador/efeitos adversos , Cirurgia Assistida por Computador/instrumentação , Inquéritos e Questionários , Fatores de Tempo , Resultado do Tratamento
16.
Circ Arrhythm Electrophysiol ; 15(6): e010975, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35617267

RESUMO

BACKGROUND: Following left atrial appendage (LAA) electrical isolation, the decision on whether to continue oral anticoagulation after successful atrial fibrillation ablation is based on the study of its mechanical function on transesophageal echocardiography (TEE). In this cohort, LAA contraction is absent and the incorrect interpretation of emptying flow velocities can lead to unwanted clinical sequelae. METHODS: One hundred and sixty consecutive TEE exams performed to evaluate the LAA mechanical function following its electrical isolation were reviewed by an experienced operator blinded to the original diagnosis of LAA dysfunction. The rate of diagnostic discrepancy in the assessment LAA dysfunction and its clinical implications were evaluated. RESULTS: Diagnostic discrepancy with misclassification of the LAA mechanical function occurred 36% (58/160) of TEE exams. In most cases (57/58), such discrepancy was observed in the setting of an incorrect original diagnosis of a normal LAA mechanical function despite absent/reduced or inconsistent LAA contraction. This main source of this wrong diagnosis was the wrong interpretation of passive LAA flows (34/57; 60%), followed by failure to identify dissociated firing (15/57; 26%). In rare cases (8/57; 14%), velocities of surrounding structures were interpreted as LAA flow due to misplacement of the pulsed-wave Doppler sample volume. Following LAA isolation, the proportion of patients who experienced a cerebrovascular event while off oral anticoagulation due to the misclassification of their LAA mechanical function was 70% (7/10 [95% CI, 40%-89%]). CONCLUSIONS: Underdiagnosis of LAA mechanical dysfunction is common in TEEs performed following LAA electrical isolation, and it is associated with an increased risk of cerebrovascular events owing to oral anticoagulation discontinuation despite absent/reduced LAA contraction. Careful review of the TEE exam by an operator with specific expertise in LAA imaging and familiar with the functional implications of LAA isolation is necessary before interrupting oral anticoagulation in this cohort.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Anticoagulantes/uso terapêutico , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ecocardiografia Transesofagiana/métodos , Humanos
17.
J Cardiovasc Electrophysiol ; 22(2): 169-74, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20731744

RESUMO

UNLABELLED: INTRODUCTION: Cardiovascular magnetic resonance imaging (cMRI) may provide a noninvasive method to test for pulmonary vein (PV) isolation after ablation for atrial fibrillation (AF) by detecting changes in PV contraction. METHODS: PV contraction (the maximal percentage change in PV cross-sectional area [CSA] during the cardiac cycle) measured 1 month before and 2 months after PV isolation was compared in 63 PVs from 16 patients with medically refractory AF. Repeat cMRI imaging and invasive catheter mapping was performed prior to repeat PV ablation in 50 PVs from 14 additional patients with recurrent AF. Contraction in PVs with sustained isolation after the initial ablation was compared to contraction in PVs with electrical reconnection to adjacent atrium. Receiver operating characteristic (ROC) curve analysis was performed to determine the optimal cutoff PV contraction value for prediction of PV-atrial reconnection after ablation. The cutoff value was then prospectively tested in 40 PVs from 12 additional patients. RESULTS: PV contraction decreased after AF ablation (22.4 ± 10% variation in CSA before ablation vs 10.1 ± 8% variation in CSA after ablation, P < 0.00001). PVs with sustained isolation on invasive mapping contracted less than PVs with electrical reconnection to adjacent atrium (13.7 ± 10.6% vs 21.4 ± 9.3%, P = 0.021). PV contraction produced a c-index of 0.74 for prediction of PV-atrial reconnection after ablation and >17% variation in PV CSA predicted reconnection with a sensitivity of 84.6% and specificity of 66.7%. CONCLUSION: PV contraction is reduced by ablation. PV contraction measurement may provide a noninvasive method to test for PV isolation after ablation procedures.


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter , Contração Muscular , Músculo Liso/fisiopatologia , Veias Pulmonares/fisiopatologia , Veias Pulmonares/cirurgia , Idoso , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Resultado do Tratamento , Vasoconstrição
18.
Europace ; 13(12): 1717-22, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21821855

RESUMO

AIMS: Chronic kidney disease (CKD) is increasingly prevalent, and is an independent risk factor for cardiovascular mortality. Clinical trials of the implantable cardioverter-defibrillator (ICD) have demonstrated a survival benefit over medical therapy for the prevention of sudden cardiac death, but its benefit in patients with concomitant CKD is unclear. METHODS AND RESULTS: We studied 199 subjects with CKD, defined as an estimated glomerular filtration rate (eGFR) <60 mL/min/1.73 m(2), who underwent ICD implantation in the Duke Electrophysiology Genetic and Genomic Studies (EPGEN) biorepository. The mean age of the cohort was 67.8 ± 9.3 years, and the mean eGFR was 41.1 ± 13.2 mL/min/1.73 m(2). There were 63 deaths over a mean follow-up of 31.1 ± 18.8 months, corresponding to an annual mortality rate of 12.2%. Additionally, there was a 7% annual rate of appropriate ICD therapy. Using Cox regression analysis, older age, lower ejection fraction, and lower eGFR were found to be significant predictors of mortality. There was a gradient of risk associated with lower renal function: a 10 mL/min reduction in eGFR conferred a 48% increase in the risk of death (P < 0.001). Further adjustment for appropriate ICD therapy did not modify these associations. CONCLUSION: In patients with CKD treated with a defibrillator, more advanced renal dysfunction is associated with reduced survival despite appropriate defibrillator therapy. This may be due to competing mortality risks in this population that attenuate the benefit of the ICD in reducing arrhythmic death. Age, ejection fraction, and kidney disease severity can be used to risk stratify patients before device implantation.


Assuntos
Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/terapia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Nefropatias/complicações , Nefropatias/fisiopatologia , Fatores Etários , Idoso , Arritmias Cardíacas/epidemiologia , Doença Crônica , Estudos de Coortes , Comorbidade , Feminino , Seguimentos , Taxa de Filtração Glomerular/fisiologia , Ventrículos do Coração/fisiopatologia , Humanos , Estimativa de Kaplan-Meier , Nefropatias/epidemiologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Volume Sistólico/fisiologia , Taxa de Sobrevida
19.
J Cardiovasc Electrophysiol ; 21(8): 849-52, 2010 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-20158561

RESUMO

INTRODUCTION: Catheter-directed atrial fibrillation (AF) ablation is contraindicated among patients with left atrial appendage (LAA) thrombus. The prevalence of LAA thrombus among fully anticoagulated patients undergoing AF ablation is unknown. METHODS AND RESULTS: We retrospectively evaluated the prevalence of LAA thrombus among 192 consecutive patients undergoing AF ablation between July 2006 and January 2009. Seven of 192 patients (3.6%) had evidence of thrombus on transesophageal echocardiogram (TEE) despite being fully anticoagulated on warfarin (international normalized ratio [INR] 2-3) for 4 consecutive weeks prior to echocardiogram. Univariate analysis demonstrated that structural heart disease, large left atrial dimension, and number of AF ablations were associated with thrombus. Three patients with thrombus had paroxysmal AF with normal LV function. CONCLUSION: Despite full anticoagulation, 3.6% of patients undergoing AF ablation had LAA thrombus. We recommend that all patients, regardless of LV function or left atrial size, should undergo preprocedural TEE to exclude the presence of LAA thrombus.


Assuntos
Anticoagulantes/uso terapêutico , Fibrilação Atrial/cirurgia , Ablação por Cateter , Trombose/epidemiologia , Adulto , Idoso , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/epidemiologia , Ablação por Cateter/efeitos adversos , Distribuição de Qui-Quadrado , Ecocardiografia Transesofagiana , Enoxaparina/uso terapêutico , Feminino , Humanos , Coeficiente Internacional Normatizado , Masculino , Pessoa de Meia-Idade , North Carolina , Prevalência , Estudos Retrospectivos , Trombose/diagnóstico por imagem , Trombose/prevenção & controle , Fatores de Tempo , Resultado do Tratamento , Varfarina/uso terapêutico
20.
JACC Clin Electrophysiol ; 6(13): 1701-1710, 2020 12 14.
Artigo em Inglês | MEDLINE | ID: mdl-33334450

RESUMO

OBJECTIVES: This study sought to compare the effect of high-dose dobutamine (DBT) with that of high-dose isoproterenol (IPN) in eliciting triggers during atrial fibrillation (AF) ablation. BACKGROUND: High-dose IPN is commonly used to elicit triggers during AF ablation. However, it is not available worldwide and, in the United States, its cost per dose has significantly increased. DBT is a similarly nonselective ß-agonist and, as such, is a potential alternative. METHODS: This was a prospective, randomized 2×2 crossover study of patients undergoing AF ablation. Patients were assigned to receive IPN (20 to 30 µg/min for 10 min) followed by DBT (40 to 50 µg/kg/min for 10 min) or vice versa in a 1:1 fashion. The type, number, and location of triggers as well as heart rate, blood pressure, and side effects were noted. RESULTS: Fifty patients were included in the study. Both drugs caused a significant increase in heart rate, with a consistently lower peak for DBT. Blood pressure significantly increased with DBT, while there was a significant reduction with IPN, despite phenylephrine support. Atrial arrhythmias induced during DBT were comparable to that induced during IPN. In patients with IPN-inducible outflow tract premature ventricular contractions, a similar effect was noted with DBT. No major complications occurred during either drug challenge. CONCLUSIONS: High-dose DBT is safe and comparable to high-dose IPN in respect of eliciting AF triggers, with the advantage to maintain systemic pressure without the need of additional vasopressor support. This study supports the use of high-dose DBT in electrophysiology laboratories in which IPN is not readily available and for those patients in whom hypotension is a concern.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/cirurgia , Estudos Cross-Over , Dobutamina/efeitos adversos , Humanos , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA