Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
BMC Microbiol ; 24(1): 206, 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38858614

RESUMO

OBJECTIVE: This study aims to examine the impact of PE/PPE gene mutations on the transmission of Mycobacterium tuberculosis (M. tuberculosis) in China. METHODS: We collected the whole genome sequencing (WGS) data of 3202 M. tuberculosis isolates in China from 2007 to 2018 and investigated the clustering of strains from different lineages. To evaluate the potential role of PE/PPE gene mutations in the dissemination of the pathogen, we employed homoplastic analysis to detect homoplastic single nucleotide polymorphisms (SNPs) within these gene regions. Subsequently, logistic regression analysis was conducted to analyze the statistical association. RESULTS: Based on nationwide M. tuberculosis WGS data, it has been observed that the majority of the M. tuberculosis burden in China is caused by lineage 2 strains, followed by lineage 4. Lineage 2 exhibited a higher number of transmission clusters, totaling 446 clusters, of which 77 were cross-regional clusters. Conversely, there were only 52 transmission clusters in lineage 4, of which 9 were cross-regional clusters. In the analysis of lineage 2 isolates, regression results showed that 4 specific gene mutations, PE4 (position 190,394; c.46G > A), PE_PGRS10 (839,194; c.744 A > G), PE16 (1,607,005; c.620T > G) and PE_PGRS44 (2,921,883; c.333 C > A), were significantly associated with the transmission of M. tuberculosis. Mutations of PE_PGRS10 (839,334; c.884 A > G), PE_PGRS11 (847,613; c.1455G > C), PE_PGRS47 (3,054,724; c.811 A > G) and PPE66 (4,189,930; c.303G > C) exhibited significant associations with the cross-regional clusters. A total of 13 mutation positions showed a positive correlation with clustering size, indicating a positive association. For lineage 4 strains, no mutations were found to enhance transmission, but 2 mutation sites were identified as risk factors for cross-regional clusters. These included PE_PGRS4 (338,100; c.974 A > G) and PPE13 (976,897; c.1307 A > C). CONCLUSION: Our results indicate that some PE/PPE gene mutations can increase the risk of M. tuberculosis transmission, which might provide a basis for controlling the spread of tuberculosis.


Assuntos
Mutação , Mycobacterium tuberculosis , Polimorfismo de Nucleotídeo Único , Tuberculose , Sequenciamento Completo do Genoma , Mycobacterium tuberculosis/genética , Mycobacterium tuberculosis/classificação , Mycobacterium tuberculosis/isolamento & purificação , China/epidemiologia , Humanos , Tuberculose/transmissão , Tuberculose/microbiologia , Tuberculose/epidemiologia , Genoma Bacteriano , Feminino , Masculino , Proteínas de Bactérias/genética , Adulto
2.
Micromachines (Basel) ; 15(4)2024 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-38675335

RESUMO

High-performance vector hydrophones have been gaining attention for underwater target-monitoring applications. Nevertheless, there exists the mutual constraint between sensitivity and bandwidth of a single hydrophone. To solve this problem, a four-unit array piezoelectric bionic MEMS vector hydrophone (FPVH) was developed in this paper, which has a cross-beam and a bionic fish-lateral-line-nerve-cell-cilia unit array structure. Simulation analysis and optimization in the design of the bionic microstructure have been performed by COMSOL 6.1 software to determine the structure dimensions and the lead zirconate titanate (PZT) thin film distribution. The FPVH was manufactured using MEMS technology and tested in a standing wave bucket. The results indicate that the FPVH has a sensitivity of up to -167.93 dB@1000 Hz (0 dB = 1 V/µPa), which is 12 dB higher than that of the one-unit piezoelectric MEMS vector hydrophone (OPVH). Additionally, the working bandwidth of the FPVH reaches 20 Hz~1200 Hz, exhibiting a good cosine curve with an 8-shape. This work paves a new way for the development of multi-unit piezoelectric vector hydrophones for underwater acoustic detectors.

3.
Micromachines (Basel) ; 14(8)2023 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-37630134

RESUMO

In response to the growing demand for high-sensitivity accelerometers in vector hydrophones, a piezoelectric MEMS accelerometer (PMA) was proposed, which has a four-cantilever beam integrated inertial mass unit structure, with the advantages of being lightweight and highly sensitive. A theoretical energy harvesting model was established for the piezoelectric cantilever beam, and the geometric dimensions and structure of the microdevice were optimized to meet the vibration pickup conditions. The sol-gel and annealing technology was employed to prepare high-quality PZT thin films on silicon substrate, and accelerometer microdevices were manufactured by using MEMS technology. Furthermore, the MEMS accelerometer was packaged for testing on a vibration measuring platform. Test results show that the PMA has a resonant frequency of 2300 Hz. In addition, there is a good linear relationship between the input acceleration and the output voltage, with V = 8.412a - 0.212. The PMA not only has high sensitivity, but also has outstanding anti-interference ability. The accelerometer structure was integrated into a vector hydrophone for testing in a calibration system. The results show that the piezoelectric vector hydrophone (PVH) has a sensitivity of -178.99 dB@1000 Hz (0 dB = 1 V/µPa) and a bandwidth of 20~1100 Hz. Meanwhile, it exhibits a good "8" shape directivity and consistency of each channel. These results demonstrate that the piezoelectric MEMS accelerometer has excellent capabilities suitable for use in vector hydrophones.

4.
Materials (Basel) ; 17(1)2023 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-38204056

RESUMO

Metal oxide semiconductors (MOSs) hold great promise for electronic devices such as gas sensors. The utilization of ZnO as a conductometric gas sensor material can be traced back to its early stages; however, its application has primarily been limited to high-temperature environments. A gas sensor based on highly porous and interconnected 3D networks of ZnO tetrapod (ZnO-T) micro-nano structures was fabricated via an easy chemical vapor deposition (CVD) method. Homemade instruments were utilized to evaluate the gas-sensing of the sample at room temperature. It exhibited good gas-sensing at room temperature, particularly with a response of up to 338.80% toward 1600 ppm ethanol, while also demonstrating remarkable repeatability, stability, and selectivity. Moreover, the unique gas-sensing properties of ZnO-T at room temperature can be reasonably explained by considering the effect of van der Waals forces in physical adsorption and the synergistic effect of carrier concentration and mobility. The aforementioned statement presents an opportunity for the advancement of gas sensors utilizing ZnO at room temperature.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA