Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Proc Natl Acad Sci U S A ; 119(50): e2211713119, 2022 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-36469770

RESUMO

The origin of the seed magnetic field that is amplified by the galactic dynamo is an open question in plasma astrophysics. Aside from primordial sources and the Biermann battery mechanism, plasma instabilities have also been proposed as a possible source of seed magnetic fields. Among them, thermal Weibel instability driven by temperature anisotropy has attracted broad interests due to its ubiquity in both laboratory and astrophysical plasmas. However, this instability has been challenging to measure in a stationary terrestrial plasma because of the difficulty in preparing such a velocity distribution. Here, we use picosecond laser ionization of hydrogen gas to initialize such an electron distribution function. We record the 2D evolution of the magnetic field associated with the Weibel instability by imaging the deflections of a relativistic electron beam with a picosecond temporal duration and show that the measured [Formula: see text]-resolved growth rates of the instability validate kinetic theory. Concurrently, self-organization of microscopic plasma currents is observed to amplify the current modulation magnitude that converts up to ~1% of the plasma thermal energy into magnetic energy, thus supporting the notion that the magnetic field induced by the Weibel instability may be able to provide a seed for the galactic dynamo.

2.
J Xray Sci Technol ; 31(6): 1227-1243, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37638471

RESUMO

BACKGROUND: Inverse Compton scattering (ICS) source can produce quasi-monoenergetic micro-focus X-rays ranging from keV to MeV level, with potential applications in the field of high-resolution computed tomography (CT) imaging. ICS source has an energy-angle correlated feature that lower photon energy is obtained at larger emission angle, thus different photon energies are inherently contained in each ICS pulse, which is especially advantageous for dual- or multi-energy CT imaging. OBJECTIVE: This study proposes a dual-energy micro-focus CT scheme based on the energy-angle correlation of ICS source and tests its function using numerical simulations. METHODS: In this scheme, high- and low-energy regions are chosen over the angular direction of each ICS pulse, and dual-energy projections of the object are obtained by an angularly-splicing scanning method. The field-of-view (FOV) of ICS source is extended simultaneously through this scanning method, thus the scale of the imaging system can be efficiently reduced. A dedicated dual-energy CT algorithm is developed to reconstruct the monoenergetic attenuation coefficients, electron density, and effective atomic number distributions of the object. RESULTS: A test object composed of different materials (carbon, aluminium, titanium, iron and copper) and line pairs with different widths (15/24/39/60 µm) is imaged by the proposed dual-energy CT scheme using numerical simulations, and high-fidelity monoenergetic attenuation coefficient, electron density, and effective atomic number distributions are obtained. All the line pairs are well identified, and the contrast ratio of the 15 µm lines is 22%, showing good accordance with the theoretical predictions. CONCLUSIONS: The proposed dual-energy CT scheme can reconstruct fine inner structures and material compositions of the object simultaneously, opening a new possibility for the application of ICS source in the field of non-destructive testing.


Assuntos
Algoritmos , Tomografia Computadorizada por Raios X , Cobre , Frequência Cardíaca , Fótons
3.
Opt Express ; 29(6): 9624-9634, 2021 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-33820386

RESUMO

We demonstrate a highly efficient method for the generation of a high-field terahertz (THz) pulse train via optical rectification (OR) in congruent lithium niobate (LN) crystals driven by temporally shaped laser pulses. A narrowband THz pulse has been successfully achieved with sub-percent level conversion efficiency and multi MV/cm peak field at 0.26 THz. For the single-cycle THz generation, we achieved a THz pulse with 373-µJ energy in a LN crystal excited by a 100-mJ laser pulse at room temperature. The conversion efficiency is further improved to 0.77 % pumped by a 20-mJ laser pulse with a smaller pump beam size (6 mm in horizontal and 15 mm in vertical). This method holds great potential for generating mJ-level narrow-band THz pulse trains, which may have a major impact in mJ-scale applications like terahertz-based accelerators and light sources.

4.
Opt Lett ; 46(11): 2795-2798, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-34061116

RESUMO

This Letter demonstrates a novel, to the best of our knowledge, method to measure the fluence distribution of an intense short laser pulse based on the radiochromic effect. We discovered that an intense short laser pulse can induce the color reaction with a radiochromic film (RCF). Further, the net optical density of an irradiated RCF is proportional to the fluence of the incident laser pulse in a large range (${2 {-} 120}\;{{{\rm mJ}/{\rm cm}}^2}$). This method supports a large detection area up to near square-meter scale by splicing multi-pieces of RCFs (${8} \times 10\;{{\rm inch}^2}$ each). The spatial resolution reaches as high as 60 lines/mm. It offers a thin-film (${\sim}{100}\;{\unicode{x00B5}{\rm m}}$ thick), flexible, vacuum-compatible solution to intense short laser measurements, especially to laser facilities above petawatt, with beam sizes up to near square-meter scale, e.g., extreme light infrastructure.

5.
Phys Rev Lett ; 127(17): 174801, 2021 Oct 22.
Artigo em Inglês | MEDLINE | ID: mdl-34739290

RESUMO

Plasma wakefield acceleration in the blowout regime is particularly promising for high-energy acceleration of electron beams because of its potential to simultaneously provide large acceleration gradients and high energy transfer efficiency while maintaining excellent beam quality. However, no equivalent regime for positron acceleration in plasma wakes has been discovered to date. We show that after a short propagation distance, an asymmetric electron beam drives a stable wakefield in a hollow plasma channel that can be both accelerating and focusing for a positron beam. A high charge positron bunch placed at a suitable distance behind the drive bunch can beam-load or flatten the longitudinal wakefield and enhance the transverse focusing force, leading to high efficiency and narrow energy spread acceleration of the positrons. Three-dimensional quasistatic particle-in-cell simulations show that an over 30% energy extraction efficiency from the wake to the positrons and a 1% level energy spread can be simultaneously obtained. Further optimization is feasible.

6.
Phys Rev Lett ; 125(25): 255001, 2020 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-33416364

RESUMO

The temporal evolution of the magnetic field associated with electron thermal Weibel instability in optical-field ionized plasmas is measured using ultrashort (1.8 ps), relativistic (45 MeV) electron bunches from a linear accelerator. The self-generated magnetic fields are found to self-organize into a quasistatic structure consistent with a helicoid topology within a few picoseconds and such a structure lasts for tens of picoseconds in underdense plasmas. The measured growth rate agrees well with that predicted by the kinetic theory of plasmas taking into account collisions. Magnetic trapping is identified as the dominant saturation mechanism.

7.
Nat Commun ; 11(1): 2787, 2020 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-32493931

RESUMO

Availability of relativistically intense, single-cycle, tunable infrared sources will open up new areas of relativistic nonlinear optics of plasmas, impulse IR spectroscopy and pump-probe experiments in the molecular fingerprint region. However, generation of such pulses is still a challenge by current methods. Recently, it has been proposed that time dependent refractive index associated with laser-produced nonlinear wakes in a suitably designed plasma density structure rapidly frequency down-converts photons. The longest wavelength photons slip backwards relative to the evolving laser pulse to form a single-cycle pulse within the nearly evacuated wake cavity. This process is called photon deceleration. Here, we demonstrate this scheme for generating high-power (~100 GW), near single-cycle, wavelength tunable (3-20 µm), infrared pulses using an 810 nm drive laser by tuning the density profile of the plasma. We also demonstrate that these pulses can be used to in-situ probe the transient and nonlinear wakes themselves.

8.
Sci Rep ; 9(1): 7796, 2019 05 24.
Artigo em Inglês | MEDLINE | ID: mdl-31127147

RESUMO

Phase-contrast imaging using X-ray sources with high spatial coherence is an emerging tool in biology and material science. Much of this research is being done using large synchrotron facilities or relatively low-flux microfocus X-ray tubes. An alternative high-flux, ultra-short and high-spatial-coherence table-top X-ray source based on betatron motions of electrons in laser wakefield accelerators has the promise to produce high quality images. In previous phase-contrast imaging studies with betatron sources, single-exposure images with a spatial resolution of 6-70 µm were reported by using large-scale laser systems (60-200 TW). Furthermore, images obtained with multiple exposures tended to have a reduced contrast and resolution due to the shot-to-shot fluctuations. In this article, we demonstrate that a highly stable multiple-exposure betatron source, with an effective average source size of 5 µm, photon number and pointing jitters of <5% and spectral fluctuation of <10%, can be obtained by utilizing ionization injection in pure nitrogen plasma using a 30-40 TW laser. Using this source, high quality phase-contrast images of biological specimens with a 5-µm resolution are obtained for the first time. This work shows a way for the application of high resolution phase-contrast imaging with stable betatron sources using modest power, high repetition-rate lasers.

9.
Rev Sci Instrum ; 88(6): 063307, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28667955

RESUMO

In China, Tsinghua Thomson Scattering X-ray Source (TTX) is the dedicated hard X-ray source based on the Thomson scattering between a terawatt ultrashort laser and a relativistic electron beam. In the TTX, two synchronized Ti: sapphire laser systems generate the terawatt ultrashort infrared scattering laser and the ultraviolet driving laser for the photocathode RF gun to produce the electron beam; measuring the timing jitter between the electron beam and the laser beam is an essential task for the X-ray source. In the present study, we report on a single shot, non-collinear cross correlator with fs resolution and measured the timing jitter between the two synchronized laser systems with a pulse-to-pulse method, which is beneficial to estimate the jitter of the X-ray yield in the TTX system. Although it is more important to synchronize the scattering laser to the electron beam and not of the driving laser, the laser-laser jitter measurement would be a good first step towards that goal, and the result generated can be considered as the error signal for the potential feedback stabilization.

10.
mBio ; 8(5)2017 10 17.
Artigo em Inglês | MEDLINE | ID: mdl-29042498

RESUMO

Large icosahedral viruses that infect bacteria represent an extreme of the coevolution of capsids and the genomes they accommodate. One subset of these large viruses is the jumbophages, tailed phages with double-stranded DNA genomes of at least 200,000 bp. We explored the mechanism leading to increased capsid and genome sizes by characterizing structures of several jumbophage capsids and the DNA packaged within them. Capsid structures determined for six jumbophages were consistent with the canonical phage HK97 fold, and three had capsid geometries with novel triangulation numbers (T=25, T=28, and T=52). Packaged DNA (chromosome) sizes were larger than the genome sizes, indicating that all jumbophages use a head-full DNA packaging mechanism. For two phages (PAU and G), the sizes appeared very much larger than their genome length. We used two-dimensional DNA gel electrophoresis to show that these two DNAs migrated abnormally due to base modifications and to allow us to calculate their actual chromosome sizes. Our results support a ratchet model of capsid and genome coevolution whereby mutations lead to increased capsid volume and allow the acquisition of additional genes. Once the added genes and larger capsid are established, mutations that restore the smaller size are disfavored.IMPORTANCE A large family of viruses share the same fold of the capsid protein as bacteriophage HK97, a virus that infects bacteria. Members of this family use different numbers of the capsid protein to build capsids of different sizes. Here, we examined the structures of extremely large capsids and measured their DNA content relative to the sequenced genome lengths, aiming to understand the process that increases size. We concluded that mutational changes leading to larger capsids become locked in by subsequent changes to the genome organization.


Assuntos
Bacteriófagos/genética , Bacteriófagos/ultraestrutura , Evolução Biológica , Capsídeo/ultraestrutura , Genoma Viral , DNA Viral/genética , Eletroforese em Gel Bidimensional , Mutação
11.
Rev Sci Instrum ; 88(4): 045110, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28456250

RESUMO

As Thomson scattering x-ray sources based on the collision of intense laser and relativistic electrons have drawn much attention in various scientific fields, there is an increasing demand for the effective methods to reconstruct the spectrum information of the ultra-short and high-intensity x-ray pulses. In this paper, a precise spectrum measurement method for the Thomson scattering x-ray sources was proposed with the diffraction of a Highly Oriented Pyrolytic Graphite (HOPG) crystal and was demonstrated at the Tsinghua Thomson scattering X-ray source. The x-ray pulse is diffracted by a 15 mm (L) ×15 mm (H)× 1 mm (D) HOPG crystal with 1° mosaic spread. By analyzing the diffraction pattern, both x-ray peak energies and energy spectral bandwidths at different polar angles can be reconstructed, which agree well with the theoretical value and simulation. The higher integral reflectivity of the HOPG crystal makes this method possible for single-shot measurement.

12.
Rev Sci Instrum ; 85(8): 083307, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25173262

RESUMO

Thomson scattering x-ray sources can produce ultrashort, energy tunable x-ray pulses characterized by high brightness, quasi-monochromatic, and high spatial coherence, which make it an ideal source for in-line phase-contrast imaging. We demonstrate the capacity of in-line phase-contrast imaging based on Tsinghua Thomson scattering X-ray source. Clear edge enhancement effect has been observed in the experiment.

13.
Rev Sci Instrum ; 84(5): 053301, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23742539

RESUMO

Tsinghua Thomson Scattering X-ray Source (TTX) is the first-of-its-kind dedicated hard X-ray source in China based on the Thomson scattering between a terawatt ultrashort laser and relativistic electron beams. In this paper, we report the experimental generation and characterization of the first hard X-ray pulses (51.7 keV) via head-on collision of an 800 nm laser and 46.7 MeV electron beams. The measured yield is 1.0 × 10(6) per pulse with an electron bunch charge of 200 pC and laser pulse energy of 300 mJ. The angular intensity distribution and energy spectra of the X-ray pulse are measured with an electron-multiplying charge-coupled device using a CsI scintillator and silicon attenuators. These measurements agree well with theoretical and simulation predictions. An imaging test using the X-ray pulse at the TTX is also presented.

14.
Rev Sci Instrum ; 81(3): 036110, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20370233

RESUMO

We have demonstrated single-shot continuously time-resolved MeV ultrafast electron diffraction using a static single crystal gold sample. An MeV high density electron pulse was used to probe the sample and then streaked by an rf deflecting cavity. The single-shot, high quality, streaked diffraction pattern allowed structural information within several picoseconds to be continuously temporally resolved with an approximately 200 fs resolution. The temporal resolution can be straightforwardly improved to 100 fs by increasing the streaking strength. We foresee that this system would become a powerful tool for ultrafast structural dynamics studies.


Assuntos
Microscopia Eletrônica de Transmissão/instrumentação , Microscopia Eletrônica de Transmissão/métodos , Ouro , Lasers , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA