Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Anal Bioanal Chem ; 2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-39078455

RESUMO

Nanocatalytic medicine, which aims to accurately target and effectively treat tumors through intratumoral in situ catalytic reactions triggered by tumor-specific environments or markers, is an emerging technology. However, the relative lack of catalytic activity of nanoenzymes in the tumor microenvironment (TME) has hampered their use in biomedical applications. Therefore, it is crucial to develop a highly sensitive probe that specifically responds to the TME or disease markers in the TME for precision diagnosis and treatment of diseases. In this work, a chiral photoacoustic (PA) nanoprobe (D/L-Ce@MoO3) based on the H2O2-catalyzed TME activation reaction was constructed in a one-step method using D-cysteine (D-Cys) or L-cysteine (L-Cys), polymolybdate, and cerium nitrate as raw materials. The designed and synthesized D/L-Ce@MoO3 chiral nanoprobe can perform in situ, non-invasive, and precise imaging of pharmacological acute liver injury. In vivo and in vitro experiments have shown that the D/L-Ce@MoO3 probe had chiral properties, the CD signal decreased upon reaction with H2O2, and the absorption and PA signals increased with increasing H2O2 concentration. This is because of the catalytic reaction between Ce ions doped in the nanoenzyme and the high expression of H2O2 caused by drug-induced liver injury to produce ·OH, which has a strong oxidizing property to kill tumor cells and destroy the Mo-S bond in the probe, thus converting the chiral probe into an achiral polyoxometalate (POM) with PA signal.

2.
Mikrochim Acta ; 191(2): 92, 2024 01 13.
Artigo em Inglês | MEDLINE | ID: mdl-38217642

RESUMO

Sensors for which the output signal is an intensity change for a single-emission peak are easily disturbed by many factors, such as the stability of the instrument, intensity of the excitation light, and biological background. However, for ratiometric fluorescence sensors, the output signal is a change in the intensity ratio of two or more emission peaks. The fluorescence intensity of these emission peaks is similarly affected by external factors; thus, these sensors have the ability to self-correct, which can greatly improve the accuracy and reliability of the detection results. To accurately image glutathione (GSH) in cells, gold nanoclusters (AuNCs) with intrinsic double emission at wavelengths of 606 nm and 794 nm were synthesized from chloroauric acid. With the emission peak at 606 nm as the recognition signal and the emission peak at 794 nm as the reference signal, a near-infrared dual-emission ratio fluorescence sensing platform was constructed to accurately detect changes in the GSH concentration in cells. In vitro and in vivo analyses showed that the ratiometric fluorescent probe specifically detects GSH and enables ultrasensitive imaging, providing a new platform for the accurate detection of active small molecules.


Assuntos
Corantes Fluorescentes , Nanopartículas Metálicas , Corantes Fluorescentes/toxicidade , Limite de Detecção , Reprodutibilidade dos Testes , Glutationa
3.
Sci Total Environ ; 929: 172761, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38670357

RESUMO

Presently, the hydroxyl radical oxidation mechanism is widely acknowledged for the degradation of organic pollutants based on hydrodynamic cavitation technology. The presence and production mechanism of other potential reactive oxygen species (ROS) in the cavitation systems are still unclear. In this paper, singlet oxygen (1O2) and superoxide radical (·O2-) were selected as the target ROS, and their generation rules and mechanism in vortex-based hydrodynamic cavitation (VBHC) were analyzed. Computational fluid dynamics (CFD) were used to simulate and analyze the intensity characteristics of VBHC, and the relationship between the generation of ROS and cavitation intensity was thoroughly revealed. The results show that the operating conditions of the device have a significant and complicated influence on the generation of 1O2 and ·O2-. When the inlet pressure reaches to 4.5 bar, it is more favorable for the generation of 1O2 and ·O2- comparing with those lower pressure. However, higher temperature (45 °C) and aeration rate (15 (L/min)/L) do not always have positive effect on the 1O2 and ·O2- productions, and their optimal parameters need to be analyzed in combination with the inlet pressure. Through quenching experiments, it is found that 1O2 is completely transformed from ·O2-, and ·O2- comes from the transformation of hydroxyl radicals and dissolved oxygen. Higher cavitation intensity is captured and shown more disperse in the vortex cavitation region, which is consistent with the larger production and stronger diffusion of 1O2 and ·O2-. This paper shed light to the generation mechanism of 1O2 and ·O2- in VBHC reactors and the relationship with cavitation intensity. The conclusion provides new ideas for the research of effective ROS in hydrodynamic cavitation process.

4.
J Cardiothorac Surg ; 18(1): 360, 2023 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-38115087

RESUMO

BACKGROUND: To summarize the anesthesia management experience for pediatric day-case patent ductus arteriosus (PDA) ligation under robot-assisted thoracoscopy and explore the key points of anesthesia management for this procedure. METHODS: The clinical data of 72 pediatric patients who underwent robot-assisted thoracoscopic day-case PDA ligation at the Children's Hospital, Zhejiang University School of Medicine from April 2021 to February 2023 were retrospectively analyzed. 0.3% ropivacaine local infiltration combined with S-ketamine 0.2 mg/kg intravenous injection was used for postoperative analgesia The patient's basic information and intraoperative conditions were analyzed, which included gender, age, weight, surgery time, anesthesia time, extubation time, intraoperative blood loss, MAP before pneumothorax, PaCO2 before pneumothorax, etc. Postoperative conditions were also monitored, such as PACU stay time, agitation during the recovery period, pain, and the incidence of nausea and vomiting. After discharge, the recovery status was assessed. RESULTS: A total of 70 pediatric patients who met the criteria for day-case PDA ligation were included in this study. Before the occurrence of pneumothorax, the mean arterial pressure (MAP) of these 70 patients was 69.58 ± 12.52 mmHg, and during controlled hypotension, the MAP was 54.96 ± 11.23 mmHg. Before the occurrence of pneumothorax, the partial pressure of carbon dioxide (PaCO2) was 38.69 ± 3.38 mmHg, and during controlled hypotension, the PaCO2 was 51.42 ± 4.05 mmHg. Three cases experienced agitation during the recovery period, and four cases had mild pain, but there was no moderate or severe pain, nausea, or vomiting. Only 1 case of postoperative respiratory tract infection and 1 case of postoperative pneumothorax occurred. Within 30 days after discharge, the unplanned revisit rate, unplanned readmission rate, and surgical wound infection rate were all 0. The residual shunt rate detected by echocardiography was 0 after 1 month. CONCLUSIONS: The children under the robot-assisted thoracoscopic day case PDA surgeries in this study have limited trauma, little bleeding, and little postoperative pain, though still at a risk of respiratory infection and pneumothorax.


Assuntos
Anestesia , Permeabilidade do Canal Arterial , Pneumotórax , Robótica , Humanos , Criança , Estudos Retrospectivos , Permeabilidade do Canal Arterial/cirurgia , Toracoscopia , Ligadura/métodos , Dor , Náusea , Vômito
5.
World J Pediatr Surg ; 3(1): e000126, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-38607939

RESUMO

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has spread widely and persistently over 100 countries. New challenges have occurred in the perioperative management of airway and anesthesia in children diagnosed with SARS-CoV-2 infection. According to current publications and to our own experiences in anesthesia management for cases with SARS-CoV-2 suspected, we reviewed concerns about the perioperative prevention of SARS-CoV-2 to medical staff and the anesthesia strategy to the patient.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA