Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Am Acad Dermatol ; 90(6): 1161-1169, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38368952

RESUMO

BACKGROUND: Guidelines recommend that patients with melanoma undergo dermatologic examination at least annually. Adherence to follow-up and its impact on survival are unclear. OBJECTIVE: To determine the level of adherence to annual dermatologic follow-up in patients with primary cutaneous melanoma, identify predictors for better adherence, and evaluate whether adherence was associated with melanoma-related mortality. METHODS: Retrospective inception cohort analysis of adults with primary invasive melanoma in Ontario, Canada from 2010 to 2013 with follow-up until December 31, 2018. RESULTS: Adherence to dermatologic follow-up was variable with only 28.0% of patients seeing a dermatologist at least annually (median follow-up 5.0 years). Younger age, female sex, higher income, greater access to dermatology care, stage 2/3 melanoma, prior keratinocyte carcinoma, fewer comorbidities, and any outpatient visit in the 12 months prior to melanoma diagnosis were predictors for adherence. Greater adherence to annual dermatology visits was associated with reduced melanoma-specific mortality compared with lower levels of adherence (adjusted hazard ratio 0.64, 95% CI 0.52-0.78). LIMITATIONS: Observational study design and inability to identify skin examinations performed by non-dermatologists. CONCLUSION: Adherence to annual dermatology visits after melanoma diagnosis was low. Greater adherence may promote better patient survival but warrants confirmation in further research including randomized trials.


Assuntos
Dermatologia , Melanoma , Neoplasias Cutâneas , Humanos , Melanoma/mortalidade , Melanoma/terapia , Feminino , Masculino , Neoplasias Cutâneas/mortalidade , Neoplasias Cutâneas/patologia , Neoplasias Cutâneas/terapia , Pessoa de Meia-Idade , Estudos Retrospectivos , Idoso , Ontário/epidemiologia , Adulto , Dermatologia/estatística & dados numéricos , Seguimentos , Cooperação do Paciente/estatística & dados numéricos , Estadiamento de Neoplasias , Estudos de Coortes , Taxa de Sobrevida , Fatores Etários
2.
Int Ophthalmol ; 43(12): 4781-4789, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37695496

RESUMO

PURPOSE: This study was conducted to compare the ocular surface temperature in keratoconus eyes with that in normal eyes. METHODS: A total of 27 participants were enrolled, with 10 and 17 participants in the keratoconus and control groups, respectively. Participants in the control group underwent an ophthalmic slit lamp examination and ocular thermography, while an additional corneal tomography was performed for those in the keratoconus group. RESULTS: For patients with keratoconus, the mean upper eyelid temperature (UET) was 32.36 ± 1.02 °C, inner canthus temperature (ICT) was 34.25 ± 0.83 °C, outer canthus temperature (OCT) was 33.62 ± 0.96 °C, initial central corneal temperature (initial CCT) was 33.04 ± 1.03 °C, sixth-second CCT (6 s-CCT) was 32.67 ± 1.19 °C, and the mean change in CCT measured within 6 s (change in CCT within 6 s) was 0.36 ± 0.26 °C. For controls, the values for UET, ICT, OCT, initial CCT, 6 s-CCT, and change in CCT within 6 s were 32.35 ± 1.13 °C, 34.14 ± 0.91 °C, 33.51 ± 1.02 °C, 33.22 ± 1.01 °C, 32.99 ± 1.01 °C, and 0.22 ± 0.17 °C, respectively. Except for the change in CCT within 6 s (p = 0.022), no significant differences were observed in UET (p = 0.973), ICT (p = 0.659), OCT (p = 0.697), initial CCT (p = 0.556) or 6 s-CCT (p = 0.310) between the two groups. CONCLUSION: The keratoconus eyes showed faster changes in CCT and evaporation of tear film after opening the eyes. Therefore, the keratoconus eyes had a higher incidence of dry eye conditions.


Assuntos
Síndromes do Olho Seco , Ceratocone , Humanos , Ceratocone/complicações , Ceratocone/diagnóstico , Temperatura , Córnea , Síndromes do Olho Seco/diagnóstico , Síndromes do Olho Seco/etiologia , Termografia
3.
Appl Opt ; 59(13): 3942-3950, 2020 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-32400664

RESUMO

The principal motivation for this paper is to reduce stray light and line roughness in concave holographic gratings (CHG). Compared with other previously reported line-smoothing grating techniques such as dynamic-exposure near-field holography, we successfully improve the line smoothing of CHG to approximately 10 nm from 2 nm. Our method uses optimization technologies and a combination of photoresist hot-melting (PHM) and oxygen-ion ashing (OIA), thereby improving the degree of stray light before and after optimization by one order of magnitude; the level processed by OIA, PHM, and OIA successively is ${7.85} \times {{10}^{ - 5}}$7.85×10-5. Combining the two technologies, we achieve lower stray light and straighter groove lines for the concave gratings, which is more effective, easy to implement, and incurs a low cost.

4.
Appl Opt ; 59(30): 9614-9620, 2020 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-33104684

RESUMO

This paper reports a two-dimensional stretchable blazed wavelength-tunable grating based on polydimethylsiloxane (PDMS). In the elastic range, stretch the grating along (Y-axis) and perpendicular to (X-axis) the grating line, fix the position of the +1st-order spot to maintain the grating period, and only change the groove angle to tune the blazed wavelength. By stretching the grating up to 20% of the Y-axis, and 5.2% of the X-axis, the groove angle is reduced by 1.33°, and the blazed wavelength of the first-order diffraction shifts toward the short-wave direction by 42.3 nm. The sensitivity of a spectrometer can be enhanced by tuning the blazed wavelength of the PDMS grating to the wavelength of the spectrum peak under observation in the bands from 460.8 nm to 503.1 nm.

5.
Appl Opt ; 59(12): 3760-3765, 2020 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-32400503

RESUMO

A novel concentric spectrometer having one convex grating and one concave mirror, working at ${+}{1}$+1st order diffraction, and with a small size, high resolution, and high diffraction efficiency, is proposed. It can simultaneously achieve high resolution and compactness by increasing the grating groove density. A compact spectrometer operating at a wavelength of 740-790 nm with an excellent imaging quality is designed. Its spectral resolution reaches 0.049 nm, and its diffraction efficiency improves by 27% compared to the conventional Offner spectrometer with convex grating working at ${-}{1}$-1st order diffraction. This is suitable for small, light, and low-cost atmospheric gas monitoring satellites.

6.
Appl Opt ; 58(27): 7609-7614, 2019 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-31674416

RESUMO

This paper proposes an accommodative intraocular lens (IOL), which consists of a two-element Alvarez lens and an aspheric lens for changing focal power and refractive power, respectively. The four-freeform-surface Alvarez lens is optimized for a multiple field of view; further, the aspheric lens also corrects the aberrations induced by the corneal asphericity of the human eye over the whole range of accommodation. A simulation using optical design software demonstrates its excellent performance in that the values of the modulation transfer function at 100 cycles/mm all reach ∼0.4 with a ±5° field of view for 3 and 5 mm pupils.

7.
Appl Opt ; 58(18): 5040-5044, 2019 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-31503824

RESUMO

This paper describes a new type of multifacet echelle grating (MFEG) for use in an echelle spectrometer. This new type of echelle grating broadens the spectral distribution on the spectral plane. We built a geometric model of MFEG to analyze the influence of the blaze angle and number of facet shapes on the spectral evolution. A dual-facet echelle grating and a four-facet echelle grating with different parameters were fabricated by rotating ion-beam etching with a self-shadowing rotating mask, based on the existing single-facet echelle grating (SFEG) with a line density of 52.7 g/mm and a blaze angle of 63.5°. The distributions of diffraction efficiency for different orders were measured with a He-Ne laser (632.8 nm); furthermore, these echelle gratings were applied in an echelle spectrometer (ICP-OES, Plasma2000), and testing spectra were obtained. The experimental results demonstrate that the MFEG can broaden the intensity distribution on the spectral plane, overcoming the weak spectral margin signal of SFEG spectrometers.

8.
Molecules ; 24(19)2019 Sep 24.
Artigo em Inglês | MEDLINE | ID: mdl-31554191

RESUMO

Cutaneous T-cell lymphomas (CTCL) are the most common primary lymphomas of the skin. We have previously identified thymocyte selection-associated high mobility group (HMG) box protein (TOX) as a promising drug target in CTCL; however, there are currently no small molecules able to directly inhibit TOX. We aimed to address this unmet opportunity by developing anti-TOX therapeutics with the use of computer-aided drug discovery methods. The available NMR-resolved structure of the TOX protein was used to model its DNA-binding HMG-box domain. To investigate the druggability of the corresponding protein-DNA interface on TOX, we performed a pilot virtual screening of 200,000 small molecules using in silico docking and identified 'hot spots' for drug-binding on the HMG-box domain. We then performed a large-scale virtual screening of 7.6 million drug-like compounds that were available from the ZINC15 database. As a result, a total of 140 top candidate compounds were selected for subsequent in vitro validation. Of those, 18 small molecules have been characterized as selective TOX inhibitors.


Assuntos
Antineoplásicos/química , Antineoplásicos/farmacologia , Desenho de Fármacos , Descoberta de Drogas/métodos , Proteínas de Grupo de Alta Mobilidade/antagonistas & inibidores , Proteínas de Grupo de Alta Mobilidade/química , Animais , Antineoplásicos/uso terapêutico , Linhagem Celular Tumoral , Proliferação de Células/efeitos dos fármacos , Humanos , Linfoma Cutâneo de Células T/tratamento farmacológico , Camundongos , Simulação de Acoplamento Molecular , Simulação de Dinâmica Molecular , Ligação Proteica , Relação Quantitativa Estrutura-Atividade , Bibliotecas de Moléculas Pequenas
9.
Appl Opt ; 57(10): 2514-2518, 2018 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-29714235

RESUMO

A new method for measuring grating groove density is proposed using multiple diffraction orders and one standard wavelength to eliminate the eccentricity effect originated from the rotation of a diffraction grating. Based on the Littman configuration for autocollimation, the groove density can be obtained by measuring the internal angles between the zeroth-order and two nonzeroth-order diffracted beams for one laser wavelength at a certain incident angle. The method was applied to measure the groove density of a plane grating with a nominal groove density of 651 lines/mm, where the mean value of this grating was measured to be 650.76 lines/mm with a relative measurement error ΔN/N of 3.8×10-5.

11.
Blood ; 125(9): 1435-43, 2015 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-25548321

RESUMO

TOX is a nuclear factor essential for the development of CD4(+) T cells in the thymus. It is normally expressed in low amounts in mature CD4(+) T cells of the skin and the peripheral blood. We have recently discovered that the transcript levels of TOX were significantly increased in mycosis fungoides, the most common type of cutaneous T-cell lymphoma (CTCL), as compared to normal skin or benign inflammatory dermatoses. However, its involvement in advanced CTCL and its biological effects on CTCL pathogenesis have not been explored. In this study, we demonstrate that TOX expression is also enhanced significantly in primary CD4(+)CD7(-) cells from patients with Sézary syndrome, a leukemic variant of CTCL, and that high TOX transcript levels correlate with increased disease-specific mortality. Stable knockdown of TOX in CTCL cells promoted apoptosis and reduced cell cycle progression, leading to less cell viability and colony-forming ability in vitro and to reduced tumor growth in vivo. Furthermore, TOX knockdown significantly increased 2 cyclin-dependent kinase (CDK) inhibitors, CDKN1B and CDKN1C. Lastly, blocking CDKN1B and CDKN1C reversed growth inhibition of TOX knockdown. Collectively, these findings provide strong evidence that aberrant TOX activation is a critical oncogenic event for CTCL.


Assuntos
Apoptose , Regulação Neoplásica da Expressão Gênica , Proteínas de Grupo de Alta Mobilidade/metabolismo , Linfoma Cutâneo de Células T/patologia , Síndrome de Sézary/patologia , Neoplasias Cutâneas/patologia , Animais , Western Blotting , Estudos de Casos e Controles , Proliferação de Células , Inibidor de Quinase Dependente de Ciclina p57/genética , Inibidor de Quinase Dependente de Ciclina p57/metabolismo , Imunofluorescência , Proteínas de Grupo de Alta Mobilidade/antagonistas & inibidores , Proteínas de Grupo de Alta Mobilidade/genética , Humanos , Linfoma Cutâneo de Células T/metabolismo , Linfoma Cutâneo de Células T/mortalidade , Camundongos , Camundongos Endogâmicos NOD , Camundongos SCID , RNA Mensageiro/genética , RNA Interferente Pequeno/genética , Reação em Cadeia da Polimerase em Tempo Real , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Síndrome de Sézary/metabolismo , Síndrome de Sézary/mortalidade , Neoplasias Cutâneas/metabolismo , Neoplasias Cutâneas/mortalidade , Células Tumorais Cultivadas , Ensaios Antitumorais Modelo de Xenoenxerto
12.
Guang Pu Xue Yu Guang Pu Fen Xi ; 37(3): 946-51, 2017 Mar.
Artigo em Zh, Inglês | MEDLINE | ID: mdl-30160445

RESUMO

Echelle grating is a kind of special diffraction grating. Working with high diffraction orders and big diffraction angle, which has the advantages of high resolution and full wave shining. It has been widely used in high-end spectrum instrument, which greatly promoted the development of aerospace, astronomy, medical, military, environment and other cutting-edge technology. However, professional scoring system needs to be customized, and the price is very expensive. The use of sophisticated ultra precision machining equipment to process in the ladder grating can greatly reduce the preparation cost of the mother plate of the ladder grating. Due to the bad straightness and high accumulative error of ultra precision single point diamond lathe, it can't satisfy the demand of preparation when preparing the echelle grating, casuing the bad diffraction wave front. In order to reduce the straightness error, this paper comes up with the error compensation for the single point diamond lathe. Firstly, we make the first compensation based on the accumulative error curve. When the compensation ratio is 0.75 to 0.85, the peak valley value (pv) of the diffraction wave front is about 400 nm, reaching its greatest effect of the first straightness compensation. Secondly, we make the straightness compensation according to the diffraction wave front curve of the blazed order. The pv of the diffraction wave front is about 83nm. The results show that the diffraction wave front is greatly improved which is beneficial to improve the quality of the grating, and has a guiding role in the actual grating characterization.

13.
J Am Acad Dermatol ; 75(6): 1126-1133, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27567033

RESUMO

BACKGROUND: There are conflicting data about the correlation between hyperhidrosis (HH) and anxiety and depression. OBJECTIVE: We sought to determine the prevalence of anxiety and depression in patients with or without HH. METHODS: We examined 2017 consecutive dermatology outpatients from Vancouver, British Columbia, Canada, and Shanghai, China, using Patient Health Questionnaire-9 and Generalized Anxiety Disorder-7 scales for anxiety and depression assessments. Multivariable logistic regression analysis was performed to evaluate if the impact of HH on anxiety and depression is dependent on demographic factors and diagnoses of the patients' presenting skin conditions. RESULTS: The prevalence of anxiety and depression was 21.3% and 27.2% in patients with HH, respectively, and 7.5% and 9.7% in patients without HH, respectively (P value <.001 for both). There were positive correlations between HH severity and the prevalence of anxiety and depression. Multivariable analysis showed that HH-associated increase in anxiety and depression prevalence is independent of demographic factors and presenting skin conditions. LIMITATION: The data from the questionnaires relied on the accuracy of patients' self-reports. CONCLUSION: Both single variant and multivariable analyses showed a significant association between HH and the prevalence of anxiety and depression in a HH severity-dependent manner.


Assuntos
Ansiedade/epidemiologia , Depressão/epidemiologia , Hiperidrose/psicologia , Adulto , Ansiedade/etnologia , Sudeste Asiático/etnologia , Colúmbia Britânica/epidemiologia , China/epidemiologia , Depressão/etnologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Escalas de Graduação Psiquiátrica , Inquéritos e Questionários , População Branca/etnologia
14.
Opt Express ; 23(14): 18300-9, 2015 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-26191886

RESUMO

A novel bandwidth-tunable notch filter is proposed based on the guided-mode resonance effect. The notch is created due to the superposition spectra response of two guided-mode resonant filters. The compact, bandwidth tuning capability is realized by taking advantage the effect of spectra-to-polarization sensitivity in one-dimensional classical guided-mode resonance filter, and using a liquid crystal polarization rotator for precise and simple polarization control. The operation principle and the design of the device are presented, and we demonstrate it experimentally. The central wavelength is fixed at 766.4 nm with a relatively symmetric profile. The full width at half maximum bandwidth could be tuned from 8.6 nm to 18.2 nm by controlling the applied voltage in electrically-driving polarization rotator.

15.
Opt Lett ; 40(5): 713-6, 2015 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-25723414

RESUMO

A novel bandwidth-tunable filter is proposed based on nonpolarizing guided-mode resonance effect. The compact, electrically driving bandwidth-tunable optical filter is realized by taking advantage of the effect of bandwidth-to-polarization sensitivity and using a twisted nematic liquid crystal polarization rotator for simple and precise polarization control. The operation principle and the design of the device are presented. The center wavelength is fixed at 623.1 nm with a relatively symmetric line shape. The full-width at half-maximum bandwidth is tuned from 12 to 44.8 nm by controlling the voltage in the polarization rotator.

17.
ScientificWorldJournal ; 2014: 495820, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24701172

RESUMO

A new kind of subwavelength metal grating with relief structure is designed and analyzed, in which the shape of the grating lines is no longer a single rectangle, but a relief structure with multiple steps. GsolverV52 was used to determine the optimal values of the grating period, groove depth, and the number of steps. The optical performance of the novel structure is evaluated and compared in terms of the transmission efficiency and extinction ratio over the visible and near-infrared wavelength spectrum. It is shown that, in the near-infrared band, the maximum transmittance can be increased about 15% compared to the traditional metal grating under the same parameters. With the unique characteristics, the metal grating is expected to find applications in liquid crystal display fields, polarization imaging, optical communication, and so on.


Assuntos
Metais/química , Desenho de Equipamento , Luz
18.
Beijing Da Xue Xue Bao Yi Xue Ban ; 46(2): 195-9, 2014 Apr 18.
Artigo em Zh | MEDLINE | ID: mdl-24743805

RESUMO

OBJECTIVE: To investigate the clinical and histopathological characteristics of basal cell carcinoma (BCC) in Chinese patients. METHODS: Clinical and pathological data of BCC confirmed by histology from 2010 to 2012 in Peking University First Hospital were retrospectively analyzed. RESULTS: Among 418 patients enrolled, the male/female ratio was 0.77:1. The average age was (65.39±13.51) years. Among the patients younger than 60 years who occupied 29% of all the cases, the male/female ratio was 1.16:1. In terms of the histology subtypes of the BCCs, 81.8% were nodular, followed by superficial (9.8%), and the others were in very small proportion. The head and face were the most common sites of BCC (86.6%). All morpheaform subtypes, and the majority of the nodular subtypes were located on the head and face, whereas the trunk and extremities were the most common locations for the others. Clinically, 86.6% of the BCC were pigmented and 80.4% were not ulcerated. The diagnostic accordance rates of BCC on the head and face (84.7%) and on the trunk (79.1%) were higher than those on the extremities (46.2%, P<0.05). CONCLUSION: The most clinical and histopathological characteristics of our cases were similar to those of Caucasian. This study displays some unique characteristics. The young and middle aged patients occupied relative higher proportion, and their gender ration was different from that of the aged group. Tumor with hyperpigmentation was popular and few cases were ulcerated. In this study, multiple BCC cases were seldom, and the BCC patients with nevus sebaceous were older than those in other reports. The research of the diagnostic accordance rates of BCC revealed that both doctors and patients should pay more attention to BCC.


Assuntos
Carcinoma Basocelular/patologia , Neoplasias Cutâneas/patologia , Idoso , Extremidades/patologia , Face/patologia , Feminino , Cabeça/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
19.
Guang Pu Xue Yu Guang Pu Fen Xi ; 34(5): 1319-22, 2014 May.
Artigo em Zh | MEDLINE | ID: mdl-25095430

RESUMO

In the present paper, the methods of spin-coating and physical vapor deposition (PVD) were researched to prepare the coronene film for UV-CCD, and their properties were characterized and compared with each other. The results of the experiment show that the process of spin-coating is relatively simple, which takes advantage of materials and retains the inherent crystal structure of coronene. However, the roughness of the film is a little more than that of PVD method; the film prepared by PVD method can absorb ultraviolet more effectively and then emits fluorescence with more intensity. Compared with the method of spin-coating, the surface of PVD film is more smoothly, and the process of thermal evaporation changes the crystal structure of coronene and forms another new crystalline state according to the XRD graph. While the whole process of PVD is morecomplex and it needs larger cost of production than spin-coating method. Besides, the comparison research work provided theoretical direction for preparing the photoluminescence down-conversion film under different requirements, such as fluorescence intensity, surface roughness and cost of production.

20.
Guang Pu Xue Yu Guang Pu Fen Xi ; 34(3): 709-12, 2014 Mar.
Artigo em Zh | MEDLINE | ID: mdl-25208397

RESUMO

A low cost and less complicated expansion approach of wavelength responses with a Lumogen phosphor coating was adopted, as they increased the quantum efficiency of CCD and CMOS detectors in ultra-violet by absorbing UV light and then re emitting visible light. In this paper, the sensitivity enhancement of fluorescence coatings was studied by adding an anti-reflection film or barrier film to reduce the loss of the scattering and reflection on the incident interface. The Lumogen and MgF2/Lumogen film were deposited on quartz glasses by physical vacuum deposition. The surface morphology, transmittance spectrum, reflectance spectrum and fluorescence emission spectrum were obtained by atomic force microscope (AFM), spectrophotometer and fluorescence spectrometer, respectively. The results indicated that MgF2 film had obvious positive effect on reducing scattering and reflection loss in 500-700 nm, and enhancing the absorption of Lumogen coating in ultraviolet spectrum. Meanwhile, the fluorescent emission intensity had a substantial increase by smoothing the film surface and thus reducing the light scattering. At the same time, the MgF2 layer could protect Lumogen coating from damaging and contamination, which give a prolong lifetime of the UV-responsive CCD sensors with fluorescent coatings.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA