Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Small ; 19(10): e2206485, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36650990

RESUMO

Pulsed laser fragmentation of microparticles (MPs) in liquid is a synthesis method for producing high-purity nanoparticles (NPs) from virtually any material. Compared with laser ablation in liquids (LAL), the use of MPs enables a fully continuous, single-step synthesis of colloidal NPs. Although having been employed in several studies, neither the fragmentation mechanism nor the efficiency or scalability have been described. Starting from time-resolved investigations of the single-pulse fragmentation of single IrO2 MPs in water, the contribution of stress-mediated processes to the fragmentation mechanism is highlighted. Single-pulse, multiparticle fragmentation is then performed in a continuously operated liquid jet. Here, 2 nm-sized nanoclusters (NCs) accompanied by larger fragments with sizes ranging between several ten nm and several µm are generated. For the nanosized product, an unprecedented efficiency of up to 18 µg J-1 is reached, which exceeds comparable values reported for high-power LAL by one order of magnitude. The generated NCs exhibit high catalytic activity and stability in oxygen evolution reactions while simultaneously expressing a redox-sensitive fluorescence, thus rendering them promising candidates in electrocatalytic sensing. The provided insights will pave the way for laser fragmentation of MPs to become a versatile, scalable yet simple technique for nanomaterial design and development.

2.
Opt Express ; 31(26): 43017-43034, 2023 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-38178405

RESUMO

We draw comparisons between the ablation and damage mechanisms that occur for both film and substrate irradiation using atomic force microscopy, scanning electron microscopy, and pump-probe reflectometry. For substrate irradiation, energy absorbed at the film-substrate interface creates a confined energy situation, resulting in a photomechanical lift-off. A partial ablation at the edges of the ablated zone formed the burr and was reduced in height by minimizing the area subject to the partial ablation threshold fluence. Substrate damage is understood to arise from free electron diffusion from indium tin oxide and subsequent laser heating. We establish a process window for substrate irradiation in a single-pulse ablation regime between approximately two to three times the ablation threshold of 0.18 J/cm2, validating the process window seen in literature and provide a crucial understanding for the ablation mechanisms of transparent conductive films.

3.
Environ Sci Technol ; 57(48): 19999-20009, 2023 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-37971371

RESUMO

Cyclic volatile methyl siloxanes (cVMS) are ubiquitous in hair care products (HCPs). cVMS emissions from HCPs are of concern, given the potential adverse impact of siloxanes on the environment and human health. To characterize cVMS emissions and exposures during the use of HCPs, realistic hair care experiments were conducted in a residential building. Siloxane-based HCPs were tested using common hair styling techniques, including straightening, curling, waving, and oiling. VOC concentrations were measured via proton-transfer-reaction time-of-flight mass spectrometry. HCP use drove rapid changes in the chemical composition of the indoor atmosphere. cVMS dominated VOC emissions from HCP use, and decamethylcyclopentasiloxane (D5) contributed the most to cVMS emissions. cVMS emission factors (EFs) during hair care routines ranged from 110-1500 mg/person and were influenced by HCP type, styling tools, operation temperatures, and hair length. The high temperature of styling tools and the high surface area of hair enhanced VOC emissions. Increasing the hair straightener temperature from room temperature to 210 °C increased cVMS EFs by 50-310%. Elevated indoor cVMS concentrations can result in substantial indoor-to-outdoor transport of cVMS via ventilation (0.4-6 tons D5/year in the U.S.); thus, hair care routines may augment the abundance of cVMS in the outdoor atmosphere.


Assuntos
Preparações para Cabelo , Compostos Orgânicos Voláteis , Humanos , Siloxanas/análise , Espectrometria de Massas , Atmosfera , Preparações para Cabelo/análise , Monitoramento Ambiental
4.
Opt Express ; 29(10): 14561-14581, 2021 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-33985177

RESUMO

In this work, we investigate single-pulse laser ablation of bulk stainless steel (AISI304), aluminium (Al) and copper (Cu) and its dependence on the pulse duration. We measured the reflectivity, ablation thresholds and volumes under the variation of pulse duration and fluence. The known drop of efficiency with increasing pulse duration is confirmed for single-pulse ablation in all three metals. We attribute the efficiency drop to a weakened photomechanically driven ablation process and a stronger contribution of photothermal phase explosion. The highest energetic efficiency and precision is achieved for pulse durations below the mechanical expansion time of 3-5 ps, where the stress confinement condition is fulfilled.

5.
Opt Express ; 29(19): 30062-30076, 2021 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-34614737

RESUMO

The interaction of ultrashort laser pulses above the ablation threshold of thin-film indium tin oxide (ITO) is examined with pump-probe microscopy. We are able to observe photomechanical spallation at delay times of hundreds of picoseconds, which plays a stronger role near the ablation threshold of 0.17 J/cm2. A phase explosion may also be observed at tens of picoseconds, playing a stronger role for increasing peak fluences. As one exceeds the material removal efficiency maximum near 0.6 J/cm2, a second spallation is observable in the center of the irradiated spot at a delay time of one nanosecond and corresponds to a crater depth of 50 nanometers. No discernable ridge formation has been observed. We recommend an industrial processing window of at least two pulses per position with a peak fluence between 0.6-1.0 J/cm2.

6.
Environ Sci Technol ; 55(24): 16477-16488, 2021 12 21.
Artigo em Inglês | MEDLINE | ID: mdl-34851619

RESUMO

Building mechanical ventilation systems are a major driver of indoor air chemistry as their design and operation influences indoor ozone (O3) concentrations, the dilution and transport of indoor-generated volatile organic compounds (VOCs), and indoor environmental conditions. Real-time VOC and O3 measurements were integrated with a building sensing platform to evaluate the influence of mechanical ventilation modes and human occupancy on the dynamics of skin oil ozonolysis products (SOOPs) in an office in a LEED-certified building during the winter. The ventilation system operated under variable recirculation ratios (RRs) from RR = 0 (100% outdoor air) to RR = 1 (100% recirculation air). Time-resolved source rates for 6-methyl-5-hepten-2-one (6-MHO), 4-oxopentanal (4-OPA), and decanal were highly dynamic and changed throughout the day with RR and occupancy. Total SOOP source rates during high-occupancy periods (10:00-18:00) varied from 2500-3000 µg h-1 when RR = 0.1 to 6300-6700 µg h-1 when RR = 1. Source rates for gas-phase reactions, outdoor air, and occupant-associated emissions generally decreased with increasing RR. The recirculation air source rate increased with RR and typically became the dominant source for RR > 0.5. SOOP emissions from surface reservoirs were also a prominent source, contributing 10-50% to total source rates. Elevated per person SOOP emission factors were observed, potentially due to multiple layers of soiled clothing worn during winter.


Assuntos
Poluentes Atmosféricos , Poluição do Ar em Ambientes Fechados , Óleos Voláteis , Ozônio , Compostos Orgânicos Voláteis , Poluentes Atmosféricos/análise , Poluição do Ar em Ambientes Fechados/análise , Monitoramento Ambiental , Humanos , Ozônio/análise , Respiração Artificial , Ventilação
7.
Environ Sci Technol ; 54(2): 714-725, 2020 01 21.
Artigo em Inglês | MEDLINE | ID: mdl-31851821

RESUMO

Mobile sampling studies have revealed enhanced levels of secondary organic aerosol (SOA) in source-rich urban environments. While these enhancements can be from rapidly reacting vehicular emissions, it was recently hypothesized that nontraditional emissions (volatile chemical products and upstream emissions) are emerging as important sources of urban SOA. We tested this hypothesis by using gas and aerosol mass spectrometry coupled with an oxidation flow reactor (OFR) to characterize pollution levels and SOA potentials in environments influenced by traditional emissions (vehicular, biogenic), and nontraditional emissions (e.g., paint fumes). We used two SOA models to assess contributions of vehicular and biogenic emissions to our observed SOA. The largest gap between observed and modeled SOA potential occurs in the morning-time urban street canyon environment, for which our model can only explain half of our observation. Contributions from VCP emissions (e.g., personal care products) are highest in this environment, suggesting that VCPs are an important missing source of precursors that would close the gap between modeled and observed SOA potential. Targeted OFR oxidation of nontraditional emissions shows that these emissions have SOA potentials that are similar, if not larger, compared to vehicular emissions. Laboratory experiments reveal large differences in SOA potentials of VCPs, implying the need for further characterization of these nontraditional emissions.


Assuntos
Poluentes Atmosféricos , Aerossóis , Oxirredução , Emissões de Veículos
8.
Opt Express ; 24(16): 17572-92, 2016 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-27505728

RESUMO

Ultrashort pulsed lasers offer a high potential in precise and efficient material processing and deep understanding of the fundamental laser-material interaction aspects is of great importance. The transient pulse reflectivity in conjunction with the transient absorption influences decisively the laser-material interaction. Direct measurements of the absorption properties by ultrafast time-resolved ellipsometry are missing to date. In this work, a unique pump-probe ellipsometry microscope is presented allowing the determination of the transient complex refractive index with a sub-ps temporal resolution. Measurements on molybdenum show ultrafast optical penetration depth changes of -6% to + 77% already within the first 10 ps after the laser pulse impact. This indicates a significant absorption variation of the pump pulse or subsequent pulses irradiating the sample on this timescale and paves the road towards a better understanding of pulse duration dependent laser ablation efficiency, double or burst mode laser ablation and lattice modifications in the first ps after the laser pulse impact.

9.
Photoacoustics ; 38: 100627, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38974141

RESUMO

This study reports an imaging method for gigahertz surface acoustic waves in transparent layers using infrared subpicosecond laser pulses in the ablation regime and an optical pump-probe technique. The reflectivity modulations due to the photoelastic effect of generated multimodal surface acoustic waves were imaged by an sCMOS camera illuminated by the time-delayed, frequency-doubled probe pulses. Moving the delay time between 6 . 0 n s to 11 . 5 n s , image stacks of wave field propagation were created. Two representative samples were investigated: wafers of isotropic fused silica and anisotropic x-cut quartz. Rayleigh (SAW) and longitudinal dominant high-velocity pseudo-surface acoustic wave (HVPSAW) modes could be observed and tracked along a circular grid around the excitation center, allowing the extraction of angular profiles of the propagation velocity. In quartz, the folding of a PSAW was observed. A finite element simulation was developed to predict the measurement results. The simulation and measurement were in good agreement with a relative error of 2 % to 5 %. These results show the potential for fast and full-field imaging of laser-generated ultrasonic surface wave modes, which can be utilized for the characterization of thin transparent samples such as semiconductor wafers or optical crystals in the gigahertz frequency range.

10.
Nat Commun ; 15(1): 7983, 2024 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-39266550

RESUMO

Owing to their exceptional mechanical, electronic, and phononic transport properties, compositionally complex alloys, including high-entropy alloys, represent an important class of materials. However, the interplay between chemical disorder and electronic correlations, and its influence on electronic structure-derived properties, remains largely unexplored. This is addressed for the archetypal CrMnFeCoNi alloy using resonant and valence band photoemission spectroscopy, electrical resistivity, and optical conductivity measurements, complemented by linear response calculations based on density functional theory. Utilizing dynamical mean-field theory, correlation signatures and damping in the spectra are identified, highlighting the significance of many-body effects, particularly in states distant from the Fermi edge. Electronic transport remains dominated by disorder and potentially short-range order, especially at low temperatures, while visible-spectrum optical conductivity and high-temperature transport are influenced by short quasiparticle lifetimes. These findings improve our understanding of element-specific electronic correlations in compositionally complex alloys and facilitate the development of advanced materials with tailored electronic properties.

11.
Ann Work Expo Health ; 67(4): 546-551, 2023 04 21.
Artigo em Inglês | MEDLINE | ID: mdl-36728003

RESUMO

We conducted an experimental case study to demonstrate the application of proton transfer reaction time-of-flight mass spectrometry (PTR-TOF-MS) for mobile breathing zone (BZ) monitoring of volatile chemical exposures in workplace environments during COVID-19 disinfection activities. The experiments were conducted in an architectural engineering laboratory-the Purdue zero Energy Design Guidance for Engineers (zEDGE) Tiny House, which served as a simulated workplace environment. Controlled disinfection activities were carried out on impermeable high-touch indoor surfaces, including the entry door, kitchen countertop, toilet bowl, bathroom sink, and shower. Worker inhalation exposure to volatile organic compounds (VOCs) was evaluated by attaching the PTR-TOF-MS sampling line to the researcher's BZ while the disinfection activity was carried out throughout the entire building. The results demonstrate that significant spatiotemporal variations in VOC concentrations can occur in the worker's BZ during multi-surface disinfection events. Application of high-resolution monitoring techniques, such as PTR-TOF-MS, are needed to advance characterization of worker exposures towards the development of appropriate mitigation strategies for volatile disinfectant chemicals.


Assuntos
COVID-19 , Exposição Ocupacional , Humanos , Prótons , Desinfecção , Espectrometria de Massas/métodos , Local de Trabalho
12.
Biomed Opt Express ; 14(5): 2276-2292, 2023 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-37206114

RESUMO

In the present study, we investigated the dynamics of a femtosecond (fs) laser induced bio-printing with cell-free and cell-laden jets under the variation of laser pulse energy and focus depth, by using time-resolved imaging. By increasing the laser pulse energy or decreasing the focus depth thresholds for a first and second jet are exceeded and more laser pulse energy is converted to kinetic jet energy. With increasing jet velocity, the jet behavior changes from a well-defined laminar jet, to a curved jet and further to an undesired splashing jet. We quantified the observed jet forms with the dimensionless hydrodynamic Weber and Rayleigh numbers and identified the Rayleigh breakup regime as the preferred process window for single cell bioprinting. Herein, the best spatial printing resolution of 42 ± 3 µm and single cell positioning precision of 12.4 µm are reached, which is less than one single cell diameter about 15 µm.

13.
Opt Express ; 20(9): 10330-8, 2012 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-22535122

RESUMO

Ultrafast pump-probe microscopy is a common method for time and space resolved imaging of short and ultra-short pulse laser ablation. The temporal delay between the ablating pump pulse and the illuminating probe pulse is tuned either by an optical delay, resulting in several hundred femtoseconds temporal resolution for delay times up to a few ns, or by an electronic delay, resulting in several nanoseconds resolution for longer delay times. In this work we combine both delay types for temporally high resolved observations of complete ablation processes ranging from femtoseconds to microseconds, while ablation is initiated by an ultrafast 660 fs laser pump pulse. For this purpose, we also demonstrate the calibration of the delay time zero point, the synchronization of both probe sources, as well as a method for image quality enhancing. In addition, we present for the first time to our knowledge pump-probe microscopy investigations of the complete substrate side selective ablation process of molybdenum films on glass. The initiation of mechanical film deformation is observed at about 400 ps, continues until approximately 15 ns, whereupon a Mo disk is sheared off free from thermal effects due to a directly induced laser lift-off ablation process.


Assuntos
Lasers de Estado Sólido , Microscopia/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento
14.
Light Sci Appl ; 11(1): 68, 2022 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-35322802

RESUMO

Laser ablation in liquids is a highly interdisciplinary method at the intersection of physics and chemistry that offers the unique opportunity to generate surfactant-free and stable nanoparticles from virtually any material. Over the last decades, numerous experimental and computational studies aimed to reveal the transient processes governing laser ablation in liquids. Most experimental studies investigated the involved processes on timescales ranging from nanoseconds to microseconds. However, the ablation dynamics occurring on a sub-nanosecond timescale are of fundamental importance, as the conditions under which nanoparticles are generated are established within this timeframe. Furthermore, experimental investigations of the early timescales are required to test computational predictions. We visualize the complete spatiotemporal picosecond laser-induced ablation dynamics of gold immersed in air and water using ultrafast pump-probe microscopy. Transient reflectivity measurements reveal that the water confinement layer significantly influences the ablation dynamics on the entire investigated timescale from picoseconds to microseconds. The influence of the water confinement layer includes the electron injection and subsequent formation of a dense plasma on a picosecond timescale, the confinement of ablation products within hundreds of picoseconds, and the generation of a cavitation bubble on a nanosecond timescale. Moreover, we are able to locate the temporal appearance of secondary nanoparticles at about 600 ps after pulse impact. The results support computational predictions and provide valuable insight into the early-stage ablation dynamics governing laser ablation in liquids.

15.
Sci Adv ; 8(8): eabj9156, 2022 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-35213219

RESUMO

Surface cleaning using commercial disinfectants, which has recently increased during the coronavirus disease 2019 pandemic, can generate secondary indoor pollutants both in gas and aerosol phases. It can also affect indoor air quality and health, especially for workers repeatedly exposed to disinfectants. Here, we cleaned the floor of a mechanically ventilated office room using a commercial cleaner while concurrently measuring gas-phase precursors, oxidants, radicals, secondary oxidation products, and aerosols in real-time; these were detected within minutes after cleaner application. During cleaning, indoor monoterpene concentrations exceeded outdoor concentrations by two orders of magnitude, increasing the rate of ozonolysis under low (<10 ppb) ozone levels. High number concentrations of freshly nucleated sub-10-nm particles (≥105 cm-3) resulted in respiratory tract deposited dose rates comparable to or exceeding that of inhalation of vehicle-associated aerosols.

16.
Micromachines (Basel) ; 12(10)2021 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-34683222

RESUMO

Femtosecond laser pulses have been successfully used for film-free single-cell bioprinting, enabling precise and efficient selection and positioning of individual mammalian cells from a complex cell mixture (based on morphology or fluorescence) onto a 2D target substrate or a 3D pre-processed scaffold. In order to evaluate the effects of higher pulse durations on the bioprinting process, we investigated cavitation bubble and jet dynamics in the femto- and picosecond regime. By increasing the laser pulse duration from 600 fs to 14.1 ps, less energy is deposited in the hydrogel for the cavitation bubble expansion, resulting in less kinetic energy for the jet propagation with a slower jet velocity. Under appropriate conditions, single cells can be reliably transferred with a cell survival rate after transfer above 95% through the entire pulse duration range. More cost efficient and compact laser sources with pulse durations in the picosecond range could be used for film-free bioprinting and single-cell transfer.

17.
J Hazard Mater Lett ; 2: 100042, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34977843

RESUMO

The COVID-19 pandemic has resulted in increased usage of ethanol-based disinfectants for surface inactivation of SARS-CoV-2 in buildings. Emissions of volatile organic compounds (VOCs) and particles from ethanol-based disinfectant sprays were characterized in real-time (1 Hz) via a proton transfer reaction time-of-flight mass spectrometer (PTR-TOF-MS) and a high-resolution electrical low-pressure impactor (HR-ELPI+), respectively. Ethanol-based disinfectants drove sudden changes in the chemical composition of indoor air. VOC and particle concentrations increased immediately after application of the disinfectants, remained elevated during surface contact time, and gradually decreased after wiping. The disinfectants produced a broad spectrum of VOCs with mixing ratios spanning the sub-ppb to ppm range. Ethanol was the dominant VOC emitted by mass, with concentrations exceeding 103 µg m-3 and emission factors ranging from 101 to 102 mg g-1. Listed and unlisted diols, monoterpenes, and monoterpenoids were also abundant. The pressurized sprays released significant quantities (104-105 cm-3) of nano-sized particles smaller than 100 nm, resulting in large deposited doses in the tracheobronchial and pulmonary regions of the respiratory system. Inhalation exposure to VOCs varied with time during the building disinfection events. Much of the VOC inhalation intake (>60 %) occurred after the disinfectant was sprayed and wiped off the surface. Routine building disinfection with ethanol-based sprays during the COVID-19 pandemic may present a human health risk given the elevated production of volatile chemicals and nano-sized particles.

18.
EClinicalMedicine ; 42: 101207, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34841237

RESUMO

BACKGROUND: COVID-19 has caused a worldwide pandemic, making the early detection of the virus crucial. We present an approach for the determination of COVID-19 infection based on breath analysis. METHODS: A high sensitivity mass spectrometer was combined with artificial intelligence and used to develop a method for the identification of COVID-19 in human breath within seconds. A set of 1137 positive and negative subjects from different age groups, collected in two periods from two hospitals in the USA, from 26 August, 2020 until 15 September, 2020 and from 11 September, 2020 until 11 November, 2020, was used for the method development. The subjects exhaled in a Tedlar bag, and the exhaled breath samples were subsequently analyzed using a Proton Transfer Reaction Time-of-Flight Mass Spectrometer (PTR-ToF-MS). The produced mass spectra were introduced to a series of machine learning models. 70% of the data was used for these sub-models' training and 30% was used for testing. FINDINGS: A set of 340 samples, 95 positives and 245 negatives, was used for the testing. The combined models successfully predicted 77 out of the 95 samples as positives and 199 out of the 245 samples as negatives. The overall accuracy of the model was 81.2%. Since over 50% of the total positive samples belonged to the age group of over 55 years old, the performance of the model in this category was also separately evaluated on 339 subjects (170 negative and 169 positive). The model correctly identified 166 out of the 170 negatives and 164 out of the 169 positives. The model accuracy in this case was 97.3%. INTERPRETATION: The results showed that this method for the identification of COVID-19 infection is a promising tool, which can give fast and accurate results.

19.
J Biophotonics ; 11(10): e201700373, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29845754

RESUMO

Several studies on hard tissue laser ablation demonstrated that ultrafast lasers enable precise material removal without thermal side effects. Although the principle ablation mechanisms have been thoroughly investigated, there are still open questions regarding the influence of material properties on transient dynamics. In this investigation, we applied pump-probe microscopy to record ablation dynamics of biomaterials with different tensile strengths (dentin, chicken bone, gallstone and kidney stones) at delay times between 1 picosecond and 10 microseconds. Transient reflectivity changes, pressure and shock wave velocities and elastic constants were determined. The result revealed that absorption and excitation show the typical well-known transient behavior of dielectric materials. We observed for all samples a photomechanical laser ablation process, where ultrafast expansion of the excited volume generates pressure waves leading to fragmentation around the excited region. In addition, we identified tensile-strength-related differences in the size of ablated craters and ejected particles. The elastic constants derived were in agreement with literature values. In conclusion, pressure-wave-assisted material removal seems to be a general mechanism for hard tissue ablation with ultrafast lasers. This photomechanical process increases ablation efficiency and removes heated material, thus ultrafast laser ablation is of interest for clinical application where heating of the tissue must be avoided.


Assuntos
Terapia a Laser , Animais , Fenômenos Biomecânicos , Dureza , Humanos , Cinética , Microscopia , Resistência à Tração
20.
PLoS One ; 13(5): e0195479, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29718923

RESUMO

Laser-induced cell transfer has been developed in recent years for the flexible and gentle printing of cells. Because of the high transfer rates and the superior cell survival rates, this technique has great potential for tissue engineering applications. However, the fact that material from an inorganic sacrificial layer, which is required for laser energy absorption, is usually transferred to the printed target structure, constitutes a major drawback of laser based cell printing. Therefore alternative approaches using deep UV laser sources and protein based acceptor films for energy absorption, have been introduced. Nevertheless, deep UV radiation can introduce DNA double strand breaks, thereby imposing the risk of carcinogenesis. Here we present a method for the laser-induced transfer of hydrogels and mammalian cells, which neither requires any sacrificial material for energy absorption, nor the use of UV lasers. Instead, we focus a near infrared femtosecond (fs) laser pulse (λ = 1030 nm, 450 fs) directly underneath a thin cell layer, suspended on top of a hydrogel reservoir, to induce a rapidly expanding cavitation bubble in the gel, which generates a jet of material, transferring cells and hydrogel from the gel/cell reservoir to an acceptor stage. By controlling laser pulse energy, well-defined cell-laden droplets can be transferred with high spatial resolution. The transferred human (SCP1) and murine (B16F1) cells show high survival rates, and good cell viability. Time laps microscopy reveals unaffected cell behavior including normal cell proliferation.


Assuntos
Células/citologia , Células/efeitos da radiação , Raios Infravermelhos , Lasers , Animais , Linhagem Celular Tumoral , Proliferação de Células , Sobrevivência Celular , Humanos , Camundongos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA