Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 32(4): 941-948, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33527562

RESUMO

Catheter ablation is an established effective approach for the treatment of atrial fibrillation (AF) in patients with heart failure, however, the role of cryoablation in this setting is unclear. Procedural success and left ventricular systolic dysfunction (LVEF) improvement in patients with LVEF ≤ 45% undergoing index catheter ablation with cryoablation were evaluated. Freedom from AF recurrence was seen in 43% rising to 59% following repeat procedure. There were significant improvements in LVEF and functional status at long-term follow-up. Results were comparable to a contemporaneous cohort of heart failure patients undergoing index ablation with radiofrequency ablation. Cryoablation is an effective first-line AF ablation approach in the setting of heart failure.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Insuficiência Cardíaca Sistólica , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
2.
J Cardiovasc Electrophysiol ; 29(3): 395-403, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29364554

RESUMO

INTRODUCTION: This study sought to validate a novel wavefront mapping system utilizing whole-chamber basket catheters (CARTOFINDER, Biosense Webster). The system was validated in terms of (1) mapping atrial-paced beats and (2) mapping complex wavefront patterns in atrial tachycardia (AT). METHODS AND RESULTS: Patients undergoing catheter ablation for AT and persistent AF were included. A 64-pole-basket catheter was used to acquire unipolar signals that were processed by CARTOFINDER mapping system to generate dynamic wavefront propagation maps. The left atrium was paced from four sites to demonstrate focal activation. ATs were mapped with the mechanism confirmed by conventional mapping, entrainment, and response to ablation. Twenty-two patients were included in the study (16 with AT and 6 with AF initially who terminated to AT during ablation). In total, 172 maps were created with the mapping system. It correctly identified atrial-pacing sites in all paced maps. It accurately mapped 9 focal/microreentrant and 18 macroreentrant ATs both in the left and right atrium. A third and fourth observer independently identified the sites of atrial pacing and the AT mechanism from the CARTOFINDER maps, while being blinded to the conventional activation maps. CONCLUSIONS: This novel mapping system was effectively validated by mapping focal activation patterns from atrial-paced beats. The system was also effective in mapping complex wavefront patterns in a range of ATs in patients with scarred atria. The system may therefore be of practical use in the mapping and ablation of AT and could have potential for mapping wavefront activations in AF.


Assuntos
Potenciais de Ação , Técnicas Eletrofisiológicas Cardíacas , Taquicardia Supraventricular/diagnóstico , Idoso , Cateteres Cardíacos , Estimulação Cardíaca Artificial , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Taquicardia Supraventricular/fisiopatologia , Taquicardia Supraventricular/cirurgia , Resultado do Tratamento
4.
Int J Cardiol ; 303: 49-53, 2020 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-32063280

RESUMO

BACKGROUND: Maintenance of sinus rhythm is challenging in patients with longstanding persistent atrial fibrillation (PeAF). Minimally invasive surgical AF ablation may improve outcomes when combined with catheter ablation (the 'convergent' procedure). This study evaluates the safety and efficacy of the convergent procedure versus catheter ablation alone in longstanding PeAF. METHODS: 43 consecutive patients with longstanding PeAF underwent subxiphoid endoscopic ablation of the posterior left atrium followed by catheter ablation from 2013 to 2018. The primary outcome was AF-free survival at 12 months; secondary outcomes included change in EHRA class, echocardiographic data, procedural complications, freedom from anti-arrhythmic drugs (AADs), and long term arrhythmia-free survival. Outcomes were compared with a matched group of 43 patients who underwent catheter ablation alone. Both groups underwent multiple catheter ablations as required. Baseline characteristics were similar between groups. RESULTS: After 12 months, the convergent procedure was associated with increased AF-free survival on AADs (60.5% versus 25.6%, p = .002) and off AADs (37.2% versus 13.9%, p = .025), versus catheter ablation. Allowing for multiple procedures, after 30.5 ±â€¯13.3 months' follow-up the convergent procedure was associated with increased arrhythmia-free survival on AADs (58.1% versus 30.2%, p = .016) and off AADs (32.5% versus 11.6%, p = .036) versus catheter ablation. There were more complications in the convergent procedure group (11.6% versus 2.3%, p = .2). Multivariate analysis identified only the convergent procedure (OR 3.06 (1.23-7.6), p = .017) as predictive of arrhythmia-free survival long term. CONCLUSIONS: In longstanding PeAF, the convergent procedure is associated with improved arrhythmia-free survival versus catheter ablation alone. Complication rates are significant but have been shown to depreciate with experience.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Átrios do Coração/diagnóstico por imagem , Sistema de Condução Cardíaco/fisiopatologia , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Pontuação de Propensão , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Intervalo Livre de Doença , Ecocardiografia , Feminino , Seguimentos , Átrios do Coração/fisiopatologia , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
5.
Data Brief ; 30: 105417, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32258280

RESUMO

In patients with longstanding persistent atrial fibrillation (AF), outcomes from catheter ablation remain suboptimal. The convergent procedure combines minimally invasive surgical ablation with subsequent catheter ablation, and may contribute towards maintenance of sinus rhythm in this patient group. We performed the convergent procedure on 43 patients with longstanding persistent AF from 2013-2018. Patients underwent clinical review at 3, 6, and 12 months and thereafter as necessitated by their symptoms. Our dataset describes patients' baseline characteristics and rhythm control protocols, as well as outcomes including arrhythmia recurrence, the need for antiarrhythmic drugs, requirement for repeat rhythm control procedures, and complications. These data provide a real world insight into the risks and benefits of the convergent procedure in patients with longstanding persistent AF.

6.
Int J Cardiol ; 278: 114-119, 2019 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-30391065

RESUMO

BACKGROUND: Low voltage zones (LVZs) are associated with conduction velocity (CV) slowing. Rate-dependent CV slowing may play a role in reentry mechanisms. METHODS: Patients undergoing catheter ablation for AT were enrolled. Aim was to assess the relationship between rate-dependent CV slowing and sites of localized reentrant atrial tachycardias (AT). On a bipolar voltage map regions were defined as non-LVZs [≥0.5 mV], LVZs [0.2-0.5 mV] and very-LVZs [<0.2 mV]. Unipolar electrograms were recorded with a 64-pole basket catheter during uninterrupted atrial pacing at four pacing intervals (PIs) during sinus rhythm. CVs were measured between pole pairs along the wavefront path. Sites of rate-dependent CV slowing were defined as exhibiting a reduction in CV between PI = 600 ms and 250 ms of ≥20% more than the mean CV reduction seen between these PIs for that voltage zone. Rate-dependent CV slowing sites were correlated to sites of localized reentrant ATs as confirmed with conventional mapping, entrainment and response to ablation. RESULTS: Eighteen patients were included (63 ±â€¯10 years). Mean CV at 600 ms was 1.53 ±â€¯0.19 m/s in non-LVZs, 1.14 ±â€¯0.15 m/s in LVZs, and 0.73 ±â€¯0.13 m/s in very-LVZs respectively (p < 0.001). Rate-dependent CV slowing sites were predominantly in LVZs [0.2-0.5 mV] (74.4 ±â€¯10.3%; p < 0.001). Localized reentrant ATs were mapped to these sites in 81.8% of cases (sensitivity 81.8%, 95% CI 48.2-97.9% and specificity 83.9%, 95% CI 81.8-86.0%). Macro-reentrant or focal ATs were not mapped to sites of rate-dependent CV slowing. CONCLUSIONS: Rate-dependent CV slowing sites are predominantly confined to LVZs [0.2-0.5 mV] and the resultant CV heterogeneity may promote reentry mechanisms. These may represent a novel adjunctive target for AT ablation.


Assuntos
Fibrilação Atrial/fisiopatologia , Ablação por Cateter/métodos , Átrios do Coração/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca/fisiologia , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/tendências , Feminino , Átrios do Coração/diagnóstico por imagem , Sistema de Condução Cardíaco/diagnóstico por imagem , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos
7.
J Interv Card Electrophysiol ; 56(2): 199-203, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29858762

RESUMO

PURPOSE: Audit has played a key role in monitoring and improving clinical practice. However, audit often fails to drive change as summative institutional data alone may be insufficient to do so. We hypothesised that the practice of attributed audit, wherein each individual's procedural performance is presented will have a greater impact on clinical practice. This hypothesis was tested in an observational study evaluating improvement in fluoroscopy times for AF ablation. METHODS: Retrospective analyses of fluoroscopy times in AF ablations at the Barts Heart Centre (BHC) from 2012-2017. Fluoroscopy times were compared pre- and post- the introduction of attributed audit in 2012 at St Bartholomew's Hospital (SBH). In order to test the hypothesis, this concept was introduced to a second group of experienced operators from the Heart Hospital (HH) as part of a merger of the two institutions in 2015 and change in fluoroscopy times recorded. RESULTS: A significant drop in fluoroscopy times (33.3 ± 9.14 to 8.95 ± 2.50, p < 0.0001) from 2012-2014 was noted after the introduction of attributed audit. At the time of merger, a significant difference in fluoroscopy times between operators from the two centres was seen in 2015. Each operator's procedural performance was shared openly at the audit meeting. Subsequent audits showed a steady decrease in fluoroscopy times for each operator with the fluoroscopy time (min, mean±SD) decreasing from 13.29 ± 7.3 in 2015 to 8.84 ± 4.8 (p < 0.0001) in 2017 across the entire group. CONCLUSIONS: Systematic improvement in fluoroscopy times for AF ablation procedures was noted byevaluating individual operators' performance. Attributing data to physicians in attributed audit can promptsignificant improvement and hence should be adopted in clinical practice.


Assuntos
Fibrilação Atrial/cirurgia , Técnicas Eletrofisiológicas Cardíacas/normas , Auditoria Médica , Ablação por Cateter , Estudos Transversais , Feminino , Fluoroscopia , Humanos , Londres , Masculino , Duração da Cirurgia , Melhoria de Qualidade , Radiografia Intervencionista , Estudos Retrospectivos
9.
Mol Cell Biol ; 7(9): 3098-106, 1987 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-2823117

RESUMO

The isolation of mutant cell lines affecting the activity of cyclic AMP (cAMP)-dependent protein kinase (PK-A) has made it possible to determine the function of this kinase in mammalian cells. We found that both a CHO cell mutant with a defective regulatory subunit (RI) for PK-A and a transfectant cell line expressing the same mutant kinase were sensitive to multiple drugs, including puromycin, adriamycin, actinomycin D, and some antimitotic drugs. The mutant and transfectant cells, after treatment with a concentration of the antimitotic drug colcemid that had no marked effect on the wild-type parent cell, had a severely disrupted microtubule network. The phenotype of hypersensitivity to the antimitotic drug colcemid was used to select revertants of the transfectant and the original mutant. These revertants simultaneously regained normal multiple drug resistance and cAMP sensitivity, thus establishing that the characteristics of colcemid sensitivity and cAMP resistance are linked. Four revertants of the transfectant reverted because of loss or rearrangement of the transfected mutant RI gene. These revertants, as well as one revertant selected from the original mutant, had PK-A activities equal to or higher than that of the parent. In these genetic studies, in which linkage of expression of a PK-A mutation with drug sensitivity is demonstrated, it was established that the PK-A system is involved in regulating resistance of mammalian cells to multiple drugs.


Assuntos
AMP Cíclico/fisiologia , Resistência a Medicamentos , Proteínas Quinases/fisiologia , Receptores de AMP Cíclico/fisiologia , Animais , Linhagem Celular , Colchicina/toxicidade , Cricetinae , Demecolcina/toxicidade , Genes , Microtúbulos/fisiologia , Mutação , Fosfoproteínas/fisiologia , Transfecção
10.
J Colloid Interface Sci ; 309(2): 194-224, 2007 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-17368660

RESUMO

In this report, the status quo and recent progress in electrokinetics are reviewed. Practical rules are recommended for performing electrokinetic measurements and interpreting their results in terms of well-defined quantities, the most familiar being the zeta-potential or electrokinetic potential. This potential is a property of charged interfaces and it should be independent of the technique used for its determination. However, often the zeta-potential is not the only property electrokinetically characterizing the electrical state of the interfacial region; the excess conductivity of the stagnant layer is an additional parameter. The requirement to obtain the zeta-potential is that electrokinetic theories be correctly used and applied within their range of validity. Basic theories and their application ranges are discussed. A thorough description of the main electrokinetic methods is given; special attention is paid to their ranges of applicability as well as to the validity of the underlying theoretical models. Electrokinetic consistency tests are proposed in order to assess the validity of the zeta-potentials obtained. The recommendations given in the report apply mainly to smooth and homogeneous solid particles and plugs in aqueous systems; some attention is paid to nonaqueous media and less ideal surfaces.

11.
Heart ; 103(18): 1413-1418, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-27613170

RESUMO

INTRODUCTION: Supraventricular tachycardias (SVTs) are a common cause of acute hospital presentations. Adenosine is an effective treatment. To date, no studies have directly compared paramedic-with hospital-delivered treatment of acute SVT with adenosine. METHOD: Randomised controlled trial comparing the treatment of SVT and discharge by paramedics with conventional emergency department (ED)-based care. Patients were excluded if they had structural heart disease or contraindication to adenosine. Discharge time, follow-up management, costs and patient satisfaction were compared. RESULTS: Eighty-six patients were enrolled: 44 were randomised to paramedic-delivered adenosine (PARA) and 42 to conventional care (ED). Of the 37 patients in the PARA group given adenosine, the tachycardia was successfully terminated in 81%. There was a 98% correlation between the paramedics' ECG diagnosis and that of two electrophysiologists. No patients had any documented adverse events in either group. The discharge time was lower in the PARA group than in the ED group (125 min (range 55-9513) vs 222 min (range 72-26 153); p=0.01), and this treatment strategy was more cost-effective (£282 vs £423; p=0.01). The majority of patients preferred this management approach. Being treated and discharged by paramedics did not result in the patients being less likely to receive ongoing management of their arrhythmia and cardiology follow-up. CONCLUSIONS: Patients with SVT can effectively and safely be treated with adenosine delivered by trained paramedics. Implementation of paramedic-delivered acute SVT care has the potential to reduce healthcare costs without compromising patient care. TRIAL REGISTRATION NUMBER: NCT02216240.


Assuntos
Adenosina/administração & dosagem , Pessoal Técnico de Saúde , Eletrocardiografia/efeitos dos fármacos , Serviços Médicos de Emergência/métodos , Satisfação do Paciente , Taquicardia Supraventricular/tratamento farmacológico , Antiarrítmicos/administração & dosagem , Análise Custo-Benefício , Relação Dose-Resposta a Droga , Serviços Médicos de Emergência/economia , Serviço Hospitalar de Emergência , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taquicardia Supraventricular/economia , Taquicardia Supraventricular/fisiopatologia , Resultado do Tratamento
12.
Int J Cardiol ; 228: 280-285, 2017 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-27865198

RESUMO

BACKGROUND: Subcutaneous implantable cardioverter defibrillators (S-ICD) have become more widely available. However, comparisons with conventional transvenous ICDs (TV-ICD) are scarce. METHODS: We conducted a propensity matched case-control study including all patients that underwent S-ICD implantation over a five-year period in a single tertiary centre. Controls consisted of all TV-ICD implant patients over a contemporary time period excluding those with pacing indication, biventricular pacemakers and those with sustained monomorphic ventricular tachycardia requiring anti-tachycardia pacing. Data was collected on device-related complications and mortality rates. A cost efficacy analysis was performed. RESULTS: Sixty-nine S-ICD cases were propensity matched to 69 TV-ICD controls. During a mean follow-up of 31±19 (S-ICD) and 32±21months (TV-ICD; p=0.88) there was a higher rate of device-related complications in the TV-ICD group predominantly accounted for by lead failures (n=20, 29% vs. n=6, 9%; p=0.004). The total mean cost for each group, including the complication-related costs was £9967±4511 ($13,639±6173) and £12,601±1786 ($17,243±2444) in the TV-ICD and S-ICD groups respectively (p=0.0001). Even though more expensive S-ICD was associated with a relative risk reduction of device-related complication of 70% with a HR of 0.30 (95%CI 0.12-0.76; p=0.01) compared to TV-ICDs. CONCLUSIONS: TV-ICDs are associated with increased device-related complication rates compared to a propensity matched S-ICD group during a similar follow-up period. Despite the existing significant difference in unit cost of the S-ICD, overall S-ICD costs may be mitigated versus TV-ICDs over a longer follow-up period.


Assuntos
Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/terapia , Análise Custo-Benefício , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica/métodos , Segurança do Paciente , Adulto , Idoso , Arritmias Cardíacas/diagnóstico , Estudos de Casos e Controles , Causas de Morte , Desfibriladores Implantáveis/economia , Cardioversão Elétrica/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Pontuação de Propensão , Estudos Retrospectivos , Medição de Risco , Índice de Gravidade de Doença , Taxa de Sobrevida , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/mortalidade , Taquicardia Ventricular/terapia , Resultado do Tratamento
13.
Lymphology ; 39(2): 84-94, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16910099

RESUMO

FOXC2 mutations cause the lymphatic/ocular disorder Lymphedema-Distichiasis (LD), and Foxc2 haploinsufficient mice mimic this disorder. To determine if FOXC2 overexpression might also cause lymphatic and/or ocular abnormalities, we performed dynamic lymphatic imaging (Evans blue dye), ocular tissue examination, and metabolic profiles in mice: transgenic for FOXC2 with an adipocyte (aP2) promoter (aP2-FOXC2 Tg), heterozygous for targeted disruption of Foxc2 (Foxc2+/-), or compound heterozygous and transgenic (Foxc2+/-, Tg) compared to wild-type controls (WT). Foxc2+/-; aP2-FOXC2 Tg; and Foxc2+/-, Tg, exhibited LD's distinctive hyperplastic lymphatic phenotype characterized by increased number of lymphatic channels and lymph nodes as well as retrograde lymph reflux. Foxc2+/-, and Foxc2+/-, Tg but not aP2-FOXC2 Tg or WT showed an abnormal ocular phenotype. Previously described alterations in brown/ white fat distribution and lean phenotype in aP2-FOXC2 transgenics were confirmed. AP2-FOXC2 Tg immunohistochemistry disclosed aberrant FOXC2 expression in ectopic sites, especially embryonic heart. Lymphatic system links with fat metabolism are discussed.


Assuntos
Modelos Animais de Doenças , Pestanas/anormalidades , Fatores de Transcrição Forkhead/fisiologia , Linfedema/genética , Adipócitos/química , Animais , Proteínas de Ligação a Ácido Graxo/genética , Ácidos Graxos/metabolismo , Feminino , Fatores de Transcrição Forkhead/genética , Glucose/metabolismo , Heterozigoto , Humanos , Técnicas Imunoenzimáticas , Insulina/metabolismo , Anormalidades Linfáticas/genética , Anormalidades Linfáticas/patologia , Linfedema/metabolismo , Masculino , Camundongos , Camundongos Knockout , Camundongos Transgênicos
14.
Br J Hosp Med (Lond) ; 77(8): 460-6, 2016 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-27487056

RESUMO

The management of atrial fibrillation extends from stroke prevention to rate or rhythm control strategies. The role of an invasive strategy is expanding and it remains important to identify suitable candidates early in the disease process.


Assuntos
Fibrilação Atrial/terapia , Antiarrítmicos/uso terapêutico , Anticoagulantes/uso terapêutico , Ablação por Cateter , Gerenciamento Clínico , Cardioversão Elétrica , Humanos
15.
Int J Cardiol ; 222: 57-61, 2016 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-27454616

RESUMO

BACKGROUND: Current guidelines for epicardial catheter ablation for ventricular tachycardia (VT) advocate that epicardial access is avoided in anticoagulated patients and should be performed prior to heparinisation. Recent studies have shown that epicardial access may be safe in heparinised patients. However, no data exist for patients on oral anticoagulants. We investigated the safety of obtaining epicardial access on uninterrupted warfarin. METHODS: A prospective registry of patients undergoing epicardial VT ablation over two years was analysed. Consecutive patients in whom epicardial access was attempted were included. All patients were heparinised prior to epicardial access with a target activated clotting time (ACT) of 300-350s. Patients who had procedures performed on uninterrupted warfarin (in addition to heparin) were compared to those not taking an oral anticoagulant. RESULTS: 46 patients were included of which 13 were taking warfarin. There was no significant difference in clinical and procedural characteristics (except INR and AF) between the two groups. Epicardial access was achieved in all patients. There were no deaths and no patients required surgery. A higher proportion of patients in the warfarin group had a drop in haemoglobin of >2g/dL compared to the no-warfarin group (38.5% versus 27.3%, p=0.74) and delayed pericardial drain removal (7.8% versus 3.03%, p=0.47). There was no difference in overall procedural complication rate. No patients required warfarin reversal or blood transfusion. CONCLUSION: Epicardial access can be achieved safely and effectively in patients' anticoagulated with warfarin and heparinised with therapeutic ACT. This may be an attractive option for patients with a high stroke risk.


Assuntos
Ablação por Cateter , Heparina , Complicações Intraoperatórias/prevenção & controle , Pericárdio/cirurgia , Complicações Pós-Operatórias/prevenção & controle , Acidente Vascular Cerebral , Taquicardia Ventricular , Varfarina , Idoso , Anticoagulantes/administração & dosagem , Anticoagulantes/efeitos adversos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Feminino , Heparina/administração & dosagem , Heparina/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Assistência Perioperatória/métodos , Assistência Perioperatória/estatística & dados numéricos , Sistema de Registros/estatística & dados numéricos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/tratamento farmacológico , Taquicardia Ventricular/cirurgia , Reino Unido , Varfarina/administração & dosagem , Varfarina/efeitos adversos
16.
Int J Cardiol ; 207: 157-63, 2016 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-26803233

RESUMO

BACKGROUND: Implantable cardioverter defibrillators (ICDs) reduce mortality in patients with ischaemic cardiomyopathy at high risk of ventricular arrhythmias (VA). However, the current indication for ICD prescription needs improvement. Telomere and telomerase in leucocytes have been shown to associate with biological ageing and pathogenesis of cardiovascular diseases. We hypothesised that leucocyte telomere length, load-of-short telomeres and/or telomerase activity are associated with VA occurrence in ischaemic cardiomyopathy patients. METHODS AND RESULTS: 90 ischaemic cardiomyopathy patients with primary prevention ICDs were recruited. 35 had received appropriate therapy from the ICD for potentially-fatal VA while the remaining 55 patients had not. No significant differences in baseline demographic data relevant to telomere biology were seen between the two groups. There was no significant difference in the age and sex adjusted mean telomere length analysed by qPCR between the groups (p=0.88). In contrast, the load-of-short telomeres assessed by Universal-STELA method and telomerase activity by TRAP assay were both higher in patients who had appropriate ICD therapy and were significantly associated with incidence of ICD therapy (p=0.02, p=0.02). ROC analyses demonstrated that the sensitivity and specificity of these telomere dynamics in predicting potentially-fatal VA was higher than the current gold-standard - left ventricular ejection fraction (AUC 0.82 versus 0.47). CONCLUSION: The load-of-short telomeres and telomerase activity had a significant association with ICD therapy (for VA) in ischaemic cardiomyopathy patients. These biomarkers should be tested in prospective studies to assess their clinical utility in predicting VA after myocardial infarction and guiding primary prevention ICD prescription.


Assuntos
Cardiomiopatias/metabolismo , Desfibriladores Implantáveis , Isquemia Miocárdica/metabolismo , Taquicardia Ventricular/metabolismo , Telomerase/metabolismo , Encurtamento do Telômero/fisiologia , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Biomarcadores/metabolismo , Cardiomiopatias/diagnóstico , Cardiomiopatias/terapia , Estudos de Casos e Controles , Estudos Transversais , Ativação Enzimática/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/terapia , Estudos Retrospectivos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Telomerase/sangue
17.
J Colloid Interface Sci ; 264(2): 502-8, 2003 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-16256671

RESUMO

Diffusing-wave spectroscopy (DWS) has been used to study the stability of sodium-caseinate-stabilized emulsions. The emulsions underwent creaming as a result of depletion flocculation when excess sodium caseinate was added. The creaming process was monitored over a 3-h period and each autocorrelation function was collected for 2 min to ensure adequate signal-to-noise ratio. The temporal variation of average particle size times the coefficient of viscosity of the continuous phase was derived from the backscattering measurements, and the variation of the scattering mean free path length with time was found from the backscattering and transmission measurements. It was confirmed that the creaming process was delayed at high oil concentrations, presumably due to the formation of oil droplet networks.

18.
J Fam Pract ; 25(5): 451-7, 1987 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-3681205

RESUMO

To investigate the incidence and correlates of childhood depression in a family practice clinic, Kovacs Childhood Depression Inventory (CDI) was administered to 64 patients, aged 6 to 12 years. Accompanying parents completed the short form of Beck's Depression Inventory (BDI) and reported on the children's behavior problems. One half of the children studied scored within the depressed range on the CDI. Thirty-nine percent of the parents scored at least mildly depressed on the BDI. Depression appeared to cluster in families. Every parent who scored in the severe depression range was accompanying a child who rated himself or herself as depressed. All parents who scored above the cutoff for mild depression rated their children as having behavior problems. Children's self-reported depression was also related to negative parental rating of the children's behavior.


Assuntos
Transtorno Depressivo/diagnóstico , Criança , Comportamento Infantil , Pré-Escolar , Transtorno Depressivo/epidemiologia , Transtorno Depressivo/genética , Medicina de Família e Comunidade , Feminino , Humanos , Masculino , Inventário de Personalidade , Psicologia da Criança , Suicídio/psicologia
19.
Int J Cardiol ; 167(5): 1984-9, 2013 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-22626840

RESUMO

CONTEXT: Transcatheter ablation of atrial fibrillation (AF) has undergone important development, with acceptable midterm results in terms of the safety and recurrence. A meta-analysis was performed to identify the periprocedural complications, midterm success rates and predictors of recurrence after AF ablation. METHODS AND RESULTS: 4357 patients with paroxysmal AF, 1083 with persistent AF and 1777 with long standing AF were included. The pooled analysis showed that there was an in-hospital complication rate of tamponade requiring drainage of 0.99% (0.44-1.54; CI 99%), stroke with neurological persistent impairment of 0.22% (0.04-0.47; CI 99%), and stroke without of 0.36% (0.03-0.70; CI 99%) After a follow up of 22 (13-28) months and 1.23 (1.19-1.5; CI 99%) procedures per patient, the AF recurrence rate was 31.20% (24.87-34.81; CI 99%). The persistent AF patients exhibited a greater risk of recurrence after the first ablation (OR 1.78 [1.14, 2.77] CI 99%), but a trend towards non significance was present in the patients with more than one procedure (OR 1.69 [0.95, 3.00] CI 99%). The most powerful predictors of an AF ablation failure in the overall population were a recurrence within 30-days (OR 4.30; 2.00-10.80), valvular AF (OR 5.20; 2.22-9.50) and a left atrium diameter of more than 50mm (OR 5.10 2.00-12.90; all CI 95%). CONCLUSIONS: Persistent AF remains burdened from higher recurrence rates, however not so following redo-procedures. Three predictors, valvular AF, a left atrium diameter longer than 50mm and recurrence within 30 days, could be appraised to drive selection of patients and therapeutic strategy.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Cateterismo Cardíaco/tendências , Ablação por Cateter/tendências , Fibrilação Atrial/fisiopatologia , Humanos , Valor Preditivo dos Testes , Recidiva , Reprodutibilidade dos Testes , Resultado do Tratamento
20.
Heart ; 96(17): 1372-8, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20483892

RESUMO

OBJECTIVES: To investigate long-term efficacy of catheter ablation for atrial fibrillation (AF) and the impact of ablating complex or fractionated electrograms (CFEs) in addition to pulmonary vein isolation and linear lesions in persistent AF (PeAF). METHODS: Consecutive cases from 2002-2007 were analysed. All the patients underwent a wide-area circumferential ablation with confirmation of electrical isolation. For PeAF, linear lesions were added, with additional targeting of CFE from 2005. Data were collected in a prospective database. Attempts were made to contact all patients for follow-up. RESULTS: 285 patients underwent 530 procedures. The mean (SD) age was 57 (11) years, 75% were male, 20% had structural heart disease and 53% had paroxysmal AF (PAF). The mean number of procedures was 1.9 per patient (1.7 for PAF and 2.0 for PeAF). Procedural complications included stroke or transient ischemic attack in 0.6% and pericardial effusion requiring drainage in 1.7%. During 2.7 years (0.2 to 7.4 years) of follow-up from the last procedure, there were seven deaths (unrelated to their ablation or AF) and three strokes or transient ischemic attack (0.3% per year). Freedom from AF/atrial tachyarrhythmia was 86% for PAF and 68% for PeAF. Late recurrence was 3 per 100 years of follow-up after >3 years. The Kaplan-Meier analysis showed that CFE ablation improved the outcome for PeAF after the first cluster of procedures (p=0.049), with a trend towards improved final outcome (p=0.130). CONCLUSIONS: Long-term freedom from AF is achievable in most patients with PAF and PeAF with low rates of late recurrence. Additional targeting of CFE improves outcome for PeAF. Late adverse events including stroke are few.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Idoso , Ablação por Cateter/efeitos adversos , Ablação por Cateter/estatística & dados numéricos , Eletrocardiografia , Métodos Epidemiológicos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA