Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
J Appl Clin Med Phys ; 25(1): e14235, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38059633

RESUMO

PURPOSE: The purpose of this investigation was to assess the effect of visceral adipose tissue volume (VA) on reader efficacy in diagnosing and characterizing small bowel Crohn's disease using lower exposure CT enterography (CTE). Secondarily, we investigated the effect of lower exposure and VA on reader diagnostic confidence. METHODS: Prospective paired investigation of 256 CTE, 129 with Crohn's disease, were reconstructed at 100% and simulated 50% and 30% exposure. The senior author provided the disease classification for the 129 patients with Crohn's disease. Patient VA was measured, and exams were evaluated by six readers for presence or absence of Crohn's disease and phenotype using a 0-10-point scale. Logistic regression models assessed the effect of VA on sensitivity and specificity. RESULTS: The effect of VA on sensitivity was significantly reduced at 30% exposure (odds radio [OR]: 1.00) compared to 100% exposure (OR: 1.12) (p = 0.048). There was no statistically significant difference among the exposures with respect to the effect of visceral fat on specificity (p = 0.159). The study readers' probability of agreement with the senior author on disease classification was 60%, 56%, and 53% at 100%, 50%, and 30% exposure, respectively (p = 0.004). When detecting low severity Crohn's disease, readers' mean sensitivity was 83%, 75%, and 74% at 100%, 50%, and 30% exposure, respectively (p = 0.002). In low severity disease, sensitivity also tended to increase as visceral fat increased (ORs per 1000 cm3 increase in visceral fat: 1.32, 1.31, and 1.18, p = 0.010, 0.016, and 0.100, at 100%, 50%, and 30% exposure). CONCLUSIONS: While the interaction is complex, VA plays a role in detecting and characterizing small bowel Crohn's disease when exposure is altered, particularly in low severity disease.


Assuntos
Doença de Crohn , Enteropatias , Humanos , Doença de Crohn/diagnóstico por imagem , Gordura Intra-Abdominal/diagnóstico por imagem , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos
2.
Radiographics ; 40(1): 291-302, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31756124

RESUMO

Uterine transplantation (UT) is a novel treatment for absolute uterine factor infertility (AUFI) that is currently being performed under experimental protocols in multiple medical centers worldwide. At the time of this publication, there have been at least 10 live births by women with a transplanted uterus. As successful outcomes from this innovative procedure increase, it is likely that more centers will perform UT. Imaging is performed in multiple steps of the UT process, including preoperative imaging of potential donors and recipients, posttransplant surveillance, and monitoring of pregnancy. Fetal imaging is performed by maternal-fetal medicine professionals, but most imaging examinations in UT are performed by radiologists. Given the significant role of imaging in this groundbreaking surgery, radiologists must be familiar with the causes of AUFI and the role of imaging in establishing this diagnosis. Radiologists working in medical centers where UT is performed should understand the role of imaging in preoperative planning and postoperative surveillance. While data regarding complications of UT are preliminary at best, radiologists must be aware of the risk of vascular compromise and graft failure and their imaging features. The authors provide a brief history of UT and define the radiologist's role in pre- and postoperative imaging assessments.©RSNA, 2019.


Assuntos
Infertilidade Feminina/diagnóstico por imagem , Infertilidade Feminina/cirurgia , Papel do Médico , Radiologistas , Útero/transplante , Feminino , Humanos , Complicações Pós-Operatórias/diagnóstico por imagem , Gravidez , Diagnóstico Pré-Natal/métodos , Transplante Homólogo
3.
AJR Am J Roentgenol ; 208(5): 1171-1175, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28177646

RESUMO

OBJECTIVE: The purpose of this study was to determine whether digital breast tomosynthesis (DBT) is a cost-effective alternative to full-field digital mammography (FFDM) for both Medicare and privately insured patients undergoing screening mammography. MATERIALS AND METHODS: A retrospective data analysis was performed between July 15, 2013, and July 14, 2014, with data on women presenting for screening mammography that included any additional radiologic workup (n = 6319). Patients chose to undergo DBT or FFDM on the basis of personal preference, physician suggestion, and cost difference. The summation of findings over the 1-year period were used to calculate recall rates, cancer detection rates, and billing costs for a regional private insurer and Medicare. RESULTS: Data from the 6319 patients who participated were divided: 3655 patients underwent DBT, and 2664 underwent FFDM during the year of screening. Private insurance billing cost $2.9 million, and Medicare cost $1.2 million for screening, follow-up imaging, and radiologic procedures. Per-person costs were approximately $40 higher for the DBT group using both forms of insurance. However, cost per cancer detected was lower in the DBT group for both private and governmental insurance, leading to potentially $3.7 million and $899,000 saved per 100 cancers found. After standardization of the difference in cancer detection rates between the two groups, DBT was a cost-equivalent alternative to FFDM for private insurance billing but was a cost-inefficient alternative with respect to Medicare costs. CONCLUSION: In a community-based setting, DBT is a cost-equivalent or potentially cost-effective alternative to FFDM and has the capacity for improving cancer detection and recall rates.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Análise Custo-Benefício , Seguro Saúde/economia , Mamografia/economia , Medicare/economia , Biópsia/métodos , Feminino , Humanos , Estudos Retrospectivos , Estados Unidos
5.
J Am Coll Radiol ; 2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38527644

RESUMO

OBJECTIVE: The purpose of this investigation was to assess gaps in radiologists' medical knowledge using abdominal subspecialty online longitudinal assessment (OLA)-type questions. Secondarily, we evaluated what question-centric factors influenced radiologists to pursue self-directed additional reading on topics presented. METHODS: A prospective OLA-type test was distributed nationally to radiologists over a 4-month period. Questions were divided into multiple groupings, including arising from three different time periods of literature (≤5 years, 6-15 years, and >20 years), relating to common versus uncommon modalities, and guideline-based versus knowledge-based characterization. After each question, participants rated their confidence in diagnosis and perceived question relevance. Answers were provided, and links to answer explanations and references were provided and tracked. A series of regression models were used to test potential predictors of correct response, participant confidence, and perceived question relevance. RESULTS: In all, 119 participants initiated the survey, with 100 answering at least one of the questions. Participants had significantly lower perceived relevance (mean: 51.3, 59.2, and 62.1 for topics ≤5 years old, 6-15 years old, and >20 years old, respectively; P < .001) and confidence (mean: 48.4, 57.8, and 63.4, respectively; P < .001) with questions on newer literature compared with older literature. Participants were significantly more likely to read question explanations for questions on common modalities compared with uncommon (46% versus 40%; P = .005) and on guideline-based questions compared with knowledge-based questions (49% versus 43%; P = .01). DISCUSSION: OLA-type questions function by identifying areas in which radiologists lack knowledge or confidence and highlight areas in which participants have interest in further education.

6.
Radiol Clin North Am ; 61(5): 889-899, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37495295

RESUMO

Uterus transplantation (UTx) is a novel procedure being studied as a treatment of absolute uterine factor infertility. Imaging plays an important role throughout the life cycle of a uterus transplant. In this review, we will first describe the surgical technique of UTx. The article will then focus on the importance of imaging in the evaluation of potential recipients and donors and during the immediate post-surgical time course as graft viability is established. Imaging as part of including in vitro fertilization, pregnancy, and complications will also be discussed.


Assuntos
Infertilidade Feminina , Gravidez , Feminino , Humanos , Infertilidade Feminina/diagnóstico por imagem , Infertilidade Feminina/cirurgia , Útero/cirurgia , Útero/transplante , Ductos Paramesonéfricos
7.
Clin Exp Emerg Med ; 3(4): 239-244, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28168230

RESUMO

OBJECTIVE: Patients with implanted cardiac devices may wait extended periods for interrogation in emergency departments (EDs). Our purpose was to determine if device interrogation could be done safely and faster by ED staff. METHODS: Prospective randomized, standard therapy controlled, trial of ED staff device interrogation vs. standard process (SP), with 30-day follow-up. Eligibility criteria: ED presentation with a self-report of a potential device related complaint, with signed informed consent. SP interrogation was by company representative or hospital employee. RESULTS: Of 60 patients, 42 (70%) were male, all were white, with a median (interquartile range) age of 71 (64 to 82) years. No patient was lost to follow up. Of all patients, 32 (53%) were enrolled during business hours. The overall median (interquartile range) ED vs. SP time to interrogation was 98.5 (40 to 260) vs. 166.5 (64 to 412) minutes (P=0.013). While ED and SP interrogation times were similar during business hours, 102 (59 to 138) vs. 105 (64 to 172) minutes (P=0.62), ED interrogation times were shorter vs. SP during non-business hours; 97 (60 to 126) vs. 225 (144 to 412) minutes, P=0.002, respectively. There was no difference in ED length of stay between the ED and SP interrogation, 249 (153 to 390) vs. 246 (143 to 333) minutes (P=0.71), regardless of time of presentation. No patient in any cohort suffered an unplanned medical contact or post-discharge adverse device related event. CONCLUSION: ED staff cardiac device interrogations are faster, and with similar 30-day outcomes, as compared to SP.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA