1.
Clin Lab ; 67(1)2021 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-33491429

RESUMO

BACKGROUND: Numerous studies indicate that most error sources in hemostasis laboratories occur during the pre preanalytical phase through biological product sampling. OBJECTIVES: The purpose of this study was documentation, monitoring, and reduction of preanalytical errors through operator training. METHODS: For a period of 4 months in the "St. SpiridonË® Hospital from Iasi, 978 specimens were identified with non-conformities, due to the following causes: insufficiently-collected, hemolyzed- and coagulated samples. Data collection was conducted in two stages: before and after training of medical staff in clinical departments, upon improving the coagulation specimen sampling practices. RESULTS: The study pointed out that subsequent to training, a reduction of the coagulated samples has been registered as follows: in medical departments from 33.33% to 16.78%, in surgery from 27.20% to 17.02%, ICU (intensive care units) from 10.63% to 8.74%, and slightly in EU (emergency) from 10.63% to 8.74%. Moreover, we noticed that the incidence of hemolyzed samples increased in clinical sections, as follows: EU from 4.50% to 14.89%, medical departments from 3.42% to 9.21%, surgery from 1.44% to 6.38%, and 4.50% to 14.89% for ICU. The insufficiently sampled volume persisted during the study in almost all sections: surgery from 1.80% to 4.96%, medical from 2.52% to 4.96%, EU from 1.80% to 3.78% with a slight decrease in ICU from 1.26% to 1.18%. CONCLUSIONS: Nurses traditionally represent the core of quality medical services. Peer education is effective and implementation and compliance of sample collection procedure rules ultimately providing patient safety.


Assuntos
Fase Pré-Analítica , Manejo de Espécimes , Humanos , Laboratórios , Erros Médicos/prevenção & controle , Corpo Clínico , Segurança do Paciente
2.
Clin Lab ; 66(9)2020 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-32902218

RESUMO

BACKGROUND: The selection and rejection of non-conforming coagulation specimens is essential in safeguarding quality management in hemostasis laboratories that provide routine testing for bleeding and thrombotic disorders. In order to increase quality, it is important to reduce pre-analytical errors that generally account for 60 - 70% of total laboratory failure. The accidental presence of clots in vitro, in the pre-analytical phase of the coagulation, is a reason for coagulation specimen rejection, given that the reliability of test results can be adversely compromised. This study aimed to ascertain the effect of clots identified in the post-analytical phase within the blood sample sediments upon standard laboratory tests such as PT (prothrombin time) and APTT (activated partial thromboplastin time). METHODS: From a total of 24,670 coagulation specimens gathered and prospectively collected and analyzed at the Haematology Laboratory of the Ë®Sf. SpiridonË® Emergency County Hospital Iasi, Romania, during four months, 671 were identified with clot. Of the coagulated samples, 153 (22.80%) were considered for this study, including those specimens pinpointed with sediment clot through a post-analytical new reverification procedure. RESULTS: The comparative study of the PT and APTT results obtained based on the samples identified with sediment clots in relation to the actual results recorded after the repetition of the sampling, pointed out 43.93% false results for PT1 test, with a significant difference between the variances of the values at the two evaluated moments (t = 2.961, p = 0.0037). The pattern was congruent in the case of the APTT test as well, exhibiting 69.04% false results, for which the variances of values at the two evaluated moments displayed significant differences (t = 2.208, p = 0.0306). In both of the cases significantly lower mean values were noted in the second determination of PT (PT1: 33.1 ± 39.6 vs. PT2: 25.8 ± 30.5) and APTT (APTT1: 42.8 ± 42.7 vs. APTT2: 38.1 ± 26.1. Results are important as they highlight the actual interference between the clot in the erythrocyte sediment and the evaluation of the patient's hemostasis. CONCLUSIONS: Our results confirm that the presence of clots in the erythrocyte sediment, with no identification prior to centrifugation, significantly affect the PT and APTT analysis, their accurate results being critical for the proper diagnosis and monitoring of anticoagulant therapy.


Assuntos
Eritrócitos , Hemostasia , Testes de Coagulação Sanguínea , Humanos , Tempo de Tromboplastina Parcial , Tempo de Protrombina , Reprodutibilidade dos Testes , Romênia
3.
Clin Lab ; 65(11)2019 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-31721542

RESUMO

BACKGROUND: Monitoring of anticoagulation therapy is based on screening tests: prothrombin time (PT) and activated partial thromboplastin time (APTT). The accidental presence of a clot in the coagulation samples determines a false prolongation of PT by fibrinogen (FI) consumption and the false or delayed prolongation of APTT, depending on FI consumption or activation. The purpose of this study is to document from the present data re-garding procedures used to exclude the accidental presence of clot in the sample. METHODS: For a more efficient approach, we conducted a study based on research from the main databases that included original and peer-reviewed studies. RESULTS: We have reported studies in which pre-analytical procedures have been recommended and studies that have also presented post-analytical protocols. A correlation between the efficiency of the procedures in terms of additional laboratory costs has been performed, as well. CONCLUSIONS: Focusing on patient safety, it remains a continuous challenge for each laboratory to be able to establish its own pre-analytical and post-analytical procedure for highlighting accidental clot presence, thus ensuring provision of results with maximum confidence to the clinicians.


Assuntos
Testes de Coagulação Sanguínea/métodos , Técnicas de Laboratório Clínico/métodos , Tempo de Tromboplastina Parcial , Tempo de Protrombina , Trombose/diagnóstico , Coagulação Sanguínea , Fibrinogênio/metabolismo , Humanos