Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Pediatr ; 243: 208-213.e3, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34952008

RESUMO

In this survey study of institutions across the US, marked variability in evaluation, treatment, and follow-up of adolescents 12 through 18 years of age with mRNA coronavirus disease 2019 (COVID-19) vaccine-associated myopericarditis was noted. Only one adolescent with life-threatening complications was reported, with no deaths at any of the participating institutions.


Assuntos
COVID-19 , Miocardite , Adolescente , COVID-19/prevenção & controle , Vacinas contra COVID-19/efeitos adversos , Humanos , Miocardite/epidemiologia , Miocardite/etiologia , RNA Mensageiro
2.
Pediatr Cardiol ; 43(8): 1857-1863, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35536424

RESUMO

Supraventricular tachycardia (SVT) is a common pediatric arrhythmia. The objective of this investigation was to investigate the existence and degree of the health disparities in the treatment of pediatric patients with supraventricular tachycardia based on sociodemographic factors. This was retrospective cohort study at a large academic medical center including children ages 5-18 years old diagnosed with SVT. Patients with congenital heart disease and myocarditis were excluded. Initial treatment and ultimate treatment with either medical management or ablation were determined. The odds of having an ablation procedure were determined based on patient age, sex, race, ethnicity, and insurance status. There was a larger portion of non-White patients (p = 0.033) within the cohort that did not receive an ablation during the study period. Patients that were younger, female, American Indian/Alaskan Native, unknown race, and had missing insurance information were less likely to receive ablation therapy during the study period. In this single center, regional evaluation, we demonstrated that disparities in the treatment of pediatric SVT are present based on multiple patient sociodemographic factors. This study adds evidence to the presence of inequities in health care delivery across pediatric populations.


Assuntos
Ablação por Cateter , Cardiopatias Congênitas , Taquicardia Supraventricular , Criança , Humanos , Feminino , Pré-Escolar , Adolescente , Estudos Retrospectivos , Ablação por Cateter/métodos , Resultado do Tratamento , Taquicardia Supraventricular/cirurgia , Taquicardia Supraventricular/diagnóstico , Cardiopatias Congênitas/cirurgia
3.
J Pediatr Nurs ; 59: 81-88, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33549955

RESUMO

BACKGROUND: Children who participate in youth sports are at risk for sudden cardiac arrest (SCA) related to undetected cardiac anomalies or abrupt impact to the chest. Nurse-led interventions may prevent sudden cardiac death by helping leagues implement an emergency action plan to respond to SCA and improve safety. A youth soccer league in the Southeast with participants between the ages of 5-19 years, led by volunteer board members and coaches, did not have reliable access to automated external defibrillators or receive standardized education on SCA and cardiopulmonary resuscitation with a site-specific action plan. METHODS: A nurse-led quality improvement pilot project used partnerships to provide league access to automated external defibrillators, institute preseason SCA and cardiopulmonary resuscitation training, and establish an emergency action plan for the league's volunteers. Anonymous pre- and post-training testing was conducted to measure participant knowledge, confidence, and willingness to respond to SCA. A cross-sectional survey, using a convenience sample of board members and coaches, evaluated sustainability of the intervention at midseason. INTERVENTION: Training targeted board members (Blue Shirts) to serve as leaders on the field during an SCA event and educated coaches on activating the emergency action plan. RESULTS: Blue Shirts and coaches showed significant (p < .05) improvement of knowledge, confidence, and willingness to respond to SCA after receiving the standardized preseason intervention; Blue Shirts' changes were sustained at midseason. CONCLUSION: Nurses are ideal for helping youth sports leagues implement a sustainable SCA action plan based on best-practice recommendations for emergency health and safety.


Assuntos
Serviços Médicos de Emergência , Esportes , Esportes Juvenis , Adolescente , Adulto , Criança , Pré-Escolar , Estudos Transversais , Morte Súbita Cardíaca/prevenção & controle , Humanos , Projetos Piloto , Adulto Jovem
4.
Curr Cardiol Rep ; 22(1): 5, 2020 01 16.
Artigo em Inglês | MEDLINE | ID: mdl-31950297

RESUMO

PURPOSE OF REVIEW: Pacing in pediatric and adult patients with congenital heart disease requires careful evaluation and thoughtful planning. Review of current guidelines with assessment of risk/benefit must be performed along with planning on a case-by-case basis in order to achieve maximal success and reduce risk in this specialized population of patients that is rapidly increasing in size. RECENT FINDINGS: Guidelines for pacing in pediatric and congenital heart disease patients span many years. Most recent consensus and summary guidelines address pacing in adult patients with or without congenital heart disease. Pediatric recommendations from prior documents must be included in current decision-making. Pacing in pediatric and congenital heart disease patients is important therapy. Creation of an individualized plan of care with attention to risk/benefit decision-making regarding when and how to pace is critical in this population to maximize beneficial outcome.


Assuntos
Estimulação Cardíaca Artificial/métodos , Cardiopatias Congênitas/cirurgia , Insuficiência Cardíaca/prevenção & controle , Adulto , Criança , Consenso , Humanos , Guias de Prática Clínica como Assunto , Fatores de Tempo
5.
Am Heart J ; 202: 104-108, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29920452

RESUMO

Sudden cardiac death in the young (SCDY) spans gender, race, ethnicity, and socioeconomic class. The loss of any pediatric patient is a matter of national and international public health concern, and focused efforts should be aimed at preventing these burdensome tragedies. Prepared by members of the Cardiac Safety Research Consortium, this White Paper summarizes and reports the dialogue at the second Think Tank related to the issues and the proposed solutions for the development of a national resource for screening and prevention of SCDY. This Think Tank, sponsored by the Cardiac Safety Research Consortium and the United States Food and Drug Administration, convened on February 18, 2016, in Miami, FL, to identify and resolve the barriers that prevent early identification of patients at risk for SCDY. All potential stakeholders including national and international experts from industry, medicine, academics, engineering, and community advocacy leaders had an opportunity to share ideas and collaborate.


Assuntos
Data Warehousing , Morte Súbita Cardíaca/prevenção & controle , Eletrocardiografia , Cardiopatias/diagnóstico , Programas de Rastreamento/normas , Criança , Consenso , Feminino , Humanos , Masculino , Valores de Referência
6.
Catheter Cardiovasc Interv ; 92(7): E471-E477, 2018 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-30208245

RESUMO

OBJECTIVES: To evaluate differences in radiation dose and image quality across institutions, fluoroscope vendors and generations of fluoroscopes for pediatric cardiac catheterization. BACKGROUND: Increased recognition of the potentially harmful effects of ionizing radiation has spurred technological advances in fluoroscopes, as well as increased focus on optimizing fluoroscope performance. There is currently little understanding of variability in the dose-image quality relationship across institutions, fluoroscope vendor and/or generation of equipment. METHODS: We evaluated latest generation fluoroscopes from Phillips, Siemens, GE, and Toshiba, and an older generation Phillips fluoroscope (release date 2003) at three different institutions. Radiation dose was measured using an anthropomorphic dose-assessment phantom with effective dose in mSv estimated from Monte Carlo simulations. Image quality phantom images were scored on a 12-point scale by three blinded reviewers. RESULTS: Fluoroscope effective doses ranged from 0.04 to 0.14 mSv/1,000 pulses for fluoroscopy with associated composite image quality scores ranging from 8.0 ± 0.6 to 10.4 ± 1.3. For cineangiography, effective doses ranged from 0.17 to 0.57 mSv/1,000 frames with image quality scores ranging from 10.1 ± 0.3 to 11.1 ± 0.3. There was modest correlation between effective dose and image quality (r = 0.67, P = 0.006). The older generation fluoroscope delivered consistently higher doses than the newer generation systems (2.3- to 3.5-fold higher for fluoroscopy; 1.1- to 3.4-fold higher for cineangiography) without appreciable differences in image quality. CONCLUSION: Technological advances have markedly improved fluoroscope performance. Comparing latest generation systems across vendors and institutions, we found variability in the dose-IQ relationship and speculate that this reflects both equipment and institutional optimization practices.


Assuntos
Cateterismo Cardíaco/instrumentação , Cineangiografia/instrumentação , Angiografia Coronária/instrumentação , Doses de Radiação , Exposição à Radiação , Radiografia Intervencionista/instrumentação , Cateterismo Cardíaco/efeitos adversos , Cineangiografia/efeitos adversos , Simulação por Computador , Angiografia Coronária/efeitos adversos , Desenho de Equipamento , Fluoroscopia/instrumentação , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Valor Preditivo dos Testes , Exposição à Radiação/efeitos adversos , Monitoramento de Radiação , Radiografia Intervencionista/efeitos adversos , Reprodutibilidade dos Testes
7.
Am Heart J ; 190: 123-131, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28760206

RESUMO

This White Paper, prepared by members of the Cardiac Safety Research Consortium, discusses important issues regarding sudden cardiac death in the young (SCDY), a problem that does not discriminate by gender, race, ethnicity, education, socioeconomic level, or athletic status. The occurrence of SCDY has devastating impact on families and communities. Sudden cardiac death in the young is a matter of national and international public health, and its prevention has generated deep interest from multiple stakeholders, including families who have lost children, advocacy groups, academicians, regulators, and the medical industry. To promote scientific and clinical discussion of SCDY prevention and to germinate future initiatives to move this field forward, a Cardiac Safety Research Consortium-sponsored Think Tank was held on February 21, 2015 at the US Food and Drug Administration's White Oak facilities, Silver Spring, MD. The ultimate goal of the Think Tank was to spark initiatives that lead to the development of a rational, reliable, and sustainable national health care resource focused on SCDY prevention. This article provides a detailed summary of discussions at the Think Tank and descriptions of related multistakeholder initiatives now underway: it does not represent regulatory guidance.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Recursos em Saúde/organização & administração , Vigilância da População/métodos , Pesquisa Qualitativa , Morte Súbita Cardíaca/epidemiologia , Humanos , Incidência , Estados Unidos/epidemiologia , Adulto Jovem
8.
Cardiol Young ; 27(2): 261-266, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27087659

RESUMO

BACKGROUND: Knowledge regarding factors that influence deviation of the QRS axis is important when seeking to differentiate between physiological and pathological changes. We hypothesised that, in contrast to those patients with an atrioventricular septal defect and common atrioventricular junction permitting only atrial shunting, those associated with ventricular shunting would show no relationship between the positions of the papillary muscles and the degree of the leftward deviation of the QRS axis. METHODS: We compared the positions of endocardial origin of the papillary muscles, and the frontal plane QRS axis, in patients with atrioventricular septal defects and common atrioventricular junction permitting exclusively atrial as opposed to atrial and ventricular shunting. RESULTS: We analysed 18 patients with atrial and ventricular shunting and 23 patients with exclusively atrial shunting. The correlation coefficient between the ratio of distances of the papillary muscles from the mid-septum and the amount of leftward deviation in the frontal plane QRS axis was 0.1 (p=0.4) in those with ventricular shunting and 0.26 (p=0.01) in those with exclusively atrial shunting. CONCLUSIONS: In contrast to patients with the so-called primum form of atrioventricular septal defect, in whom the locations of the papillary muscles correlate with the degree of QRS axis, such relationships are lacking in patients with defects permitting both atrial and ventricular shunting. It may be, therefore, that the presence of ventricular shunting and/or their younger age causes pressure overload, which negates the leftward QRS forces caused by the abnormally positioned papillary muscles.


Assuntos
Eletrocardiografia , Átrios do Coração/diagnóstico por imagem , Sistema de Condução Cardíaco/diagnóstico por imagem , Defeitos dos Septos Cardíacos/diagnóstico , Músculos Papilares/diagnóstico por imagem , Pré-Escolar , Ecocardiografia , Feminino , Seguimentos , Átrios do Coração/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Defeitos dos Septos Cardíacos/fisiopatologia , Humanos , Lactente , Masculino , Estudos Retrospectivos
9.
Pediatr Cardiol ; 37(8): 1534-1538, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27562131

RESUMO

The need to perform catheter ablation of ventricular arrhythmia from within the sinuses of Valsalva in a pediatric patient is uncommon. This has been reported in adults, but there are little data about the feasibility, safety or efficacy of catheter ablation in the sinuses of Valsalva in the pediatric patients. This is a retrospective review of all patients aged 18 years or less, at two separate institutions with no structural heart disease that underwent an ablation procedure for ventricular arrhythmia mapped to the sinus of Valsalva from 2010 to 2015. We identified 8 total patients meeting inclusion criteria. Median age was 16 years and the median weight was 61 kg. All patients were symptomatic or had developed arrhythmia-induced ventricular dysfunction. Ablation was performed in the left sinus in 4 patients and the right sinus in 4 patients. No ablations were required in the non-coronary sinus. All 8 patients had an acutely successful ablation using radiofrequency energy. There were no complications. At a mean follow-up of 7 months (4-15 months), all patients were known to be living. Follow-up data regarding arrhythmia were available in 6 of the 8 patients, and none had recurrence of their ventricular arrhythmia off of all antiarrhythmic medications. Radiofrequency catheter ablation of ventricular arrhythmia in the sinus of Valsalva can be done safely and effectively in pediatric patients.


Assuntos
Seio Aórtico , Adolescente , Ablação por Cateter , Eletrocardiografia , Humanos , Estudos Retrospectivos , Taquicardia Ventricular
10.
J Am Heart Assoc ; 10(17): e019887, 2021 09 07.
Artigo em Inglês | MEDLINE | ID: mdl-34459253

RESUMO

Background Pathogenic variation in the ATP1A3-encoded sodium-potassium ATPase, ATP1A3, is responsible for alternating hemiplegia of childhood (AHC). Although these patients experience a high rate of sudden unexpected death in epilepsy, the pathophysiologic basis for this risk remains unknown. The objective was to determine the role of ATP1A3 genetic variants on cardiac outcomes as determined by QT and corrected QT (QTc) measurements. Methods and Results We analyzed 12-lead ECG recordings from 62 patients (male subjects=31, female subjects=31) referred for AHC evaluation. Patients were grouped according to AHC presentation (typical versus atypical), ATP1A3 variant status (positive versus negative), and ATP1A3 variant (D801N versus other variants). Manual remeasurements of QT intervals and QTc calculations were performed by 2 pediatric electrophysiologists. QTc measurements were significantly shorter in patients with positive ATP1A3 variant status (P<0.001) than in patients with genotype-negative status, and significantly shorter in patients with the ATP1A3-D801N variant than patients with other variants (P<0.001). The mean QTc for ATP1A3-D801N was 344.9 milliseconds, which varied little with age, and remained <370 milliseconds throughout adulthood. ATP1A3 genotype status was significantly associated with shortened QTc by multivariant regression analysis. Two patients with the ATP1A3-D801N variant experienced ventricular fibrillation, resulting in death in 1 patient. Rare variants in ATP1A3 were identified in a large cohort of genotype-negative patients referred for arrhythmia and sudden unexplained death. Conclusions Patients with AHC who carry the ATP1A3-D801N variant have significantly shorter QTc intervals and an increased likelihood of experiencing bradycardia associated with life-threatening arrhythmias. ATP1A3 variants may represent an independent cause of sudden unexplained death. Patients with AHC should be evaluated to identify risk of sudden death.


Assuntos
Bradicardia , Hemiplegia , ATPase Trocadora de Sódio-Potássio , Fibrilação Ventricular , Arritmias Cardíacas , Bradicardia/genética , Pré-Escolar , Suscetibilidade a Doenças , Feminino , Genótipo , Hemiplegia/genética , Humanos , Masculino , Mutação , ATPase Trocadora de Sódio-Potássio/genética , Fibrilação Ventricular/genética
11.
J Electrocardiol ; 43(6): 566-71, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-21040826

RESUMO

Structural inhomogeneities in cardiac tissue have been associated with increased cellular repolarization alternans in animal experiments and increased T-wave alternans (TWA) in clinical studies. However, the effect of structural inhomogeneities on the relationship between cellular alternans and TWA has not been thoroughly investigated. We created 1-dimensional multicellular fiber models with and without a resistive barrier in various fiber regions and paced each model to induce cellular alternans. The models demonstrate that a resistive barrier in one fiber region substantially alters cellular repolarization alternans throughout the fiber. A midmyocardial or subepicardial barrier increase both TWA amplitude and maximum cellular alternans magnitude, relative to a fiber without a barrier. In addition, a direct relationship exists between TWA amplitude and maximum cellular alternans magnitude, which was highly dependent on barrier location. These results suggest that the position of a structural inhomogeneity within the myocardium may have substantial effects on dynamic repolarization instability and arrhythmogenicity.


Assuntos
Potenciais de Ação , Eletrocardiografia/métodos , Sistema de Condução Cardíaco/fisiopatologia , Modelos Cardiovasculares , Miócitos Cardíacos , Taquicardia Ventricular/fisiopatologia , Simulação por Computador , Diagnóstico por Computador/métodos , Humanos , Taquicardia Ventricular/diagnóstico
12.
J Cardiovasc Electrophysiol ; 20(2): 182-6, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18803560

RESUMO

BACKGROUND: The presence of a single left superior vena cava in the absence of complex congenital heart disease is uncommon, and, in the absence of hemodynamic consequences, it would not be expected to result in cardiovascular signs or symptoms. Single case reports and our anecdotal experience suggested to us that this anomaly is highly associated with cardiac arrhythmias. OBJECTIVE: We sought to describe the clinically important arrhythmias in a population of young patients having this anomaly. METHODS: A retrospective chart review was performed from all patients <20 years old and who were determined by echocardiography over an 11-year-period to have a single left superior vena cava and minor or no coexisting congenital heart defects. The prevalence of nonsinus pacemaker, age-corrected sinus rate percentile, and prevalence of brady- or tachyarrhythmias was compared with a control group of patients having bilateral superior vena cavae. RESULTS: Eight patients having a single left and 55 patients having bilateral superior vena cava(e) were identified. The existence of this anomaly tended to be associated with a lower age-corrected sinus rate percentile (17.5% vs 75%, P = 0.09), and was associated with a higher prevalence of arrhythmias (50% vs 7%, P = 0.014) compared with the control group. In the study group, one patient each had clinically relevant sinus node dysfunction, third-degree AV block, Wolff-Parkinson-White syndrome and atrial fibrillation, and AV nodal reentrant tachycardia. CONCLUSION: Even in the absence of symptoms, patients found to have a single left superior vena cava should be monitored long-term for clinically important arrhythmias.


Assuntos
Arritmias Cardíacas/etiologia , Veia Cava Superior/anormalidades , Adolescente , Arritmias Cardíacas/fisiopatologia , Fibrilação Atrial/etiologia , Bloqueio Atrioventricular/etiologia , Criança , Pré-Escolar , Ecocardiografia , Tolerância ao Exercício/fisiologia , Fadiga/etiologia , Feminino , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/fisiopatologia , Humanos , Lactente , Recém-Nascido , Masculino , Bloqueio Sinoatrial/etiologia , Síncope/etiologia , Taquicardia Supraventricular/etiologia , Veia Cava Superior/diagnóstico por imagem , Veia Cava Superior/fisiopatologia , Síndrome de Wolff-Parkinson-White/etiologia
13.
J Electrocardiol ; 42(6): 549-54, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19616219

RESUMO

T-wave alternans (TWA) is a useful marker of cardiac instability, but not much is known about the factors that affect its measurement, such as electrode placement. We used a 1-dimensional myocardial fiber computer model of alternans to investigate the effect of electrode position on TWA measurement. Results demonstrated that TWA amplitude and T-wave amplitude change proportionally if both recording electrodes are symmetrically moved toward or away from the tissue. However, TWA amplitude and T-wave amplitude change out of proportion to one another when one electrode is moved while the other electrode remains stationary. These disproportionate changes result from beatwise alternation in the asymmetric potential field around the tissue. In summary, nonlinear changes in tissue repolarization during alternans result in nonlinear changes in T-wave amplitude and TWA amplitude.


Assuntos
Potenciais de Ação , Arritmias Cardíacas/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Modelos Cardiovasculares , Miócitos Cardíacos , Animais , Simulação por Computador , Eletrocardiografia/métodos , Humanos
14.
J Electrocardiol ; 41(6): 474-9, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18804789

RESUMO

Long QT syndrome is a disease characterized by abnormal lengthening of the QT interval and by sudden cardiac death. It is a disease of development, with the incidence of a sudden event increasing during childhood. Repolarization instability during postnatal development could make the substrate susceptible to a fatal arrhythmia. Dynamic changes in repolarization that occur on a beat-to-beat basis, known as alternans, are a hallmark of electrical instability. T-wave alternans (TWA) in the electrocardiogram correlates with arrhythmia risk and long-term survival in adults. We determined TWA properties longitudinally in vivo in 7 propofol-sedated New Zealand white rabbits using transesophageal pacing weekly from 2 to 10 weeks of age. Furthermore, TWA induction after the onset of rapid pacing was characterized in vitro in 6 infant (2 weeks) and 6 adolescent (7 weeks) isolated, arterially perfused rabbit hearts. In vivo, TWA amplitude was maximum at 2 weeks and declined with age. Isoproterenol increased TWA at 8 weeks (adolescence). In vitro, large-amplitude TWA was induced with rapid pacing in both infant and adolescents but decreased to low, steady-state levels in infants. We conclude that TWA properties are age dependent in rabbit. Significant TWA is induced in rabbit at the onset of rapid pacing.


Assuntos
Envelhecimento , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Animais , Coelhos
16.
J Thorac Cardiovasc Surg ; 153(3): 638-645.e2, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27939495

RESUMO

OBJECTIVES: The study objective was to determine the predictors of new-onset arrhythmia among infants with single-ventricle anomalies during the post-Norwood hospitalization and the association of those arrhythmias with postoperative outcomes (ventilator time and length of stay) and interstage mortality. METHODS: After excluding patients with preoperative arrhythmias, we used data from the Pediatric Heart Network Single Ventricle Reconstruction Trial to identify risk factors for tachyarrhythmias (atrial fibrillation, atrial flutter, supraventricular tachycardia, junctional ectopic tachycardia, and ventricular tachycardia) and atrioventricular block (second or third degree) among 544 eligible patients. We then determined the association of arrhythmia with outcomes during the post-Norwood hospitalization and interstage period, adjusting for identified risk factors and previously published factors. RESULTS: Tachyarrhythmias were noted in 20% of subjects, and atrioventricular block was noted in 4% of subjects. Potentially significant risk factors for tachyarrhythmia included the presence of modified Blalock-Taussig shunt (P = .08) and age at Norwood (P = .07, with risk decreasing each day at age 8-20 days); the only significant risk factor for atrioventricular block was undergoing a concomitant procedure at the time of the Norwood (P = .001), with the greatest risk being in those undergoing a tricuspid valve procedure. Both tachyarrhythmias and atrioventricular block were associated with longer ventilation time and length of stay (P < .001 for all analyses). Tachyarrhythmias were not associated with interstage mortality; atrioventricular block was associated with mortality among those without a pacemaker in the unadjusted analysis (hazard ratio, 2.3; P = .02), but not after adding covariates. CONCLUSIONS: Tachyarrhythmias are common after the Norwood procedure, but atrioventricular block may portend a greater risk for interstage mortality.


Assuntos
Arritmias Cardíacas/etiologia , Cardiopatias Congênitas/cirurgia , Procedimentos de Norwood/efeitos adversos , Complicações Pós-Operatórias/etiologia , Sistema de Registros , Medição de Risco/métodos , Arritmias Cardíacas/epidemiologia , Feminino , Seguimentos , Humanos , Incidência , Lactente , Recém-Nascido , Masculino , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Fatores de Risco , Taxa de Sobrevida/tendências , Resultado do Tratamento , Estados Unidos/epidemiologia
17.
IEEE Trans Biomed Eng ; 53(8): 1708-11, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16916108

RESUMO

We present a high-efficiency, low-cost wavelength division multiplexer to record cardiac optical action potentials (APs) within the myocardial wall using optical fibers. APs with signal-to-noise ratio as high as 60, without spatial or temporal averaging, and as high as 200, with median-filtering, were recorded in rabbit ventricle.


Assuntos
Potenciais de Ação/fisiologia , Mapeamento Potencial de Superfície Corporal/instrumentação , Sistema de Condução Cardíaco/fisiologia , Microscopia de Fluorescência/instrumentação , Espectrometria de Fluorescência/instrumentação , Função Ventricular , Animais , Mapeamento Potencial de Superfície Corporal/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Técnicas In Vitro , Microscopia de Fluorescência/métodos , Coelhos , Espectrometria de Fluorescência/métodos
18.
Artigo em Inglês | MEDLINE | ID: mdl-16471436

RESUMO

Modifications were made to a commercial real-time, three-dimensional (3-D) ultrasound system for near simultaneous 3-D scanning with two matrix array transducers. As a first illustration, a transducer cable assembly was modified to incorporate two independent, 3-D intra-cardiac echo catheters, a 7 Fr (2.3 mm O.D.) side scanning catheter and a 14 Fr (4.7 mm O.D) forward viewing catheter with accessory port, each catheter using 85 channels operating at 5 MHz. For applications in treatment of atrial fibrillation, the goal is to place the sideviewing catheter within the coronary sinus to view the whole left atrium, including a pulmonary vein. Meanwhile, the forward-viewing catheter inserted within the left atrium is directed toward the ostium of a pulmonary vein for therapy using the integrated accessory port. Using preloaded, phasing data, the scanner switches between catheters automatically, at the push of a button, with a delay of about 1 second, so that the clinician can view the therapy catheter with the coronary sinus catheter and vice versa. Preliminary imaging studies in a tissue phantom and in vivo show that our system successfully guided the forward-viewing catheter toward a target while being imaged with the sideviewing catheter. The forward-viewing catheter then was activated to monitor the target while we mimicked therapy delivery. In the future, the system will switch between 3-D probes on a line-by-line basis and display both volumes simultaneously.


Assuntos
Algoritmos , Ecocardiografia Tridimensional/instrumentação , Aumento da Imagem/instrumentação , Interpretação de Imagem Assistida por Computador/instrumentação , Imageamento Tridimensional/instrumentação , Transdutores , Animais , Sistemas Computacionais , Cães , Ecocardiografia Tridimensional/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Armazenamento e Recuperação da Informação/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
20.
Ultrasound Med Biol ; 29(9): 1297-304, 2003 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-14553807

RESUMO

We have developed dual lumen probes incorporating a forward-viewing matrix array transducer with an integrated working lumen for delivery of tools in real-time 3-D (RT3-D) interventional echocardiography. The probes are of 14 Fr and 22 Fr sizes, with 112 channel 2-D arrays operating at 5 MHz. We obtained images of cardiac anatomy and simultaneous interventional device delivery with an in vivo sheep model, including: manipulation of a 0.36-mm diameter guidewire into the coronary sinus, guidance of a transseptal puncture using a 1.2-mm diameter Brockenbrough needle, and guidance of a right ventricular biopsy using 3 Fr biopsy forceps. We have also incorporated the 22 Fr probe within a 6-mm surgical trocar to obtain apical four-chamber ultrasound (US) scans from a subcostal position. Combining the imaging catheter with a working lumen in a single device may simplify cardiac interventional procedures by allowing clinicians to easily visualize cardiac structures and simultaneously direct interventional tools in a RT3-D image.


Assuntos
Ecocardiografia Tridimensional/instrumentação , Transdutores , Ultrassonografia de Intervenção/instrumentação , Animais , Biópsia/instrumentação , Biópsia/métodos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Ecocardiografia Tridimensional/métodos , Desenho de Equipamento , Estudos de Viabilidade , Modelos Animais , Imagens de Fantasmas , Punções/instrumentação , Punções/métodos , Ovinos , Ultrassonografia de Intervenção/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA