Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Biol Pharm Bull ; 45(3): 360-363, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-34937813

RESUMO

In this study, we investigated the effects of fosphenytoin (fPHT), a water-soluble prodrug of phenytoin, on the pain responses of a mouse herpes zoster (HZ) pain model. Transdermal herpes simplex virus type 1 (HSV-1) inoculation induced mechanical allodynia and hyperalgesia of the hind paw and spontaneous pain-like behaviors, such as licking the affected skin. Intravenous injection of fPHT (15 and 30 mg/kg) alleviated HSV-1-induced provoked pain (allodynia and hyperalgesia). The suppressive effects of fPHT on provoked pain were weaker than those of diclofenac and pregabalin which were used as positive controls. fPHT, diclofenac, and pregabalin significantly suppressed HSV-1-induced spontaneous pain-like behaviors. Among them, high-dose fPHT (30 mg/kg) showed the strongest suppression. Intravenous fPHT may become a viable option for an acute HZ pain, especially for spontaneous pain.


Assuntos
Herpes Simples , Herpesvirus Humano 1 , Animais , Herpes Simples/tratamento farmacológico , Hiperalgesia/tratamento farmacológico , Camundongos , Dor/tratamento farmacológico , Fenitoína/análogos & derivados , Fenitoína/farmacologia , Fenitoína/uso terapêutico
2.
PLoS One ; 19(5): e0303849, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38768185

RESUMO

PURPOSE: Random noise-moving images (noises) can make glaucoma patients with no subjective symptoms aware of visual field abnormalities. To explore this concept, we developed a noise using computer graphics (CG) and investigated the difference in the subjective perception of visual field abnormalities between CG and conventional analog noises. METHODS: We enrolled individuals with glaucoma (205 eyes), preperimetric glaucoma (PPG; 19 eyes), and normal eyes (35 eyes). For a CG noise, a series of still images was made by randomly selecting five monochromatic tones on 2-mm square dots, and these images were drawn at 60 frames per second (fps) to create a noise-moving image. The participants were asked to describe their perceived shadows on a paper. The results were categorized as follows based on the pattern deviation probability map of the Humphrey field analyzer (HFA): "agreement," "partial agreement," "disagreement," and "no response." The glaucoma stage was classified into four stages, from M1 to M4, based on the HFA's mean deviation. RESULT: The detection rates (agreement and partial agreement) were 80.5% and 65.4% for the CG and analog noises, respectively, with CG noise showing a significantly higher detection rate in all glaucoma eyes (P < 0.001). The detection rates tended to increase as the glaucoma stage progressed, and in Stage M3, these were 93.9% and 78.8% for the CG and analog noises, respectively. The PPG eyes did not exhibit subjective abnormalities for both noises. The specificity values were 97.1% and 100% for the CG and analog noises, respectively. CONCLUSION: The CG noise is more effective than the analog noise in evaluating the subjective perception of visual field abnormalities in patients with glaucoma.


Assuntos
Gráficos por Computador , Glaucoma , Campos Visuais , Humanos , Glaucoma/fisiopatologia , Campos Visuais/fisiologia , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Testes de Campo Visual/métodos , Adulto , Percepção Visual/fisiologia
3.
Eur Heart J Case Rep ; 6(2): ytac059, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35233498

RESUMO

BACKGROUND: Coronary access after transcatheter aortic valve implantation (TAVI) is challenging due to the changes in aortic geometry. The perpendicular (long-axis) view of the transcatheter heart valve (THV) is usually used as the primary fluoroscopic angle. However, it does not always provide sufficient information on the rotational axis needed for selective coronary ostia engagement. The en face (short-axis) view from the deep right-anterior-oblique cranial position gives us additional information about three-dimensional spatial relationship of the THV and coronary ostia. CASE SUMMARY: We present three cases of coronary access after TAVI. We were successful in the use of the 'en face' view along with the perpendicular view in these cases. DISCUSSION: The use of the en face view complements that of the perpendicular long-axis view since it allows the understanding of the three-dimensional spatial relationship of the THV and the coronary ostia during fluoroscopy and control of catheter manipulation in two directions (up/down for perpendicular and clockwise/counterclockwise for en face view). We believe that the en face view helps improve the technical success of coronary access after TAVI.

4.
J Cardiol ; 80(3): 190-196, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35469714

RESUMO

BACKGROUND: In transcatheter aortic valve replacement (TAVR) using SAPIEN 3 (S3) (Edwards Lifesciences, Irvine, CA, USA), some clinicians decrease or increase the delivery balloon volume (VOL) when deploying S3 or conducting post-dilatation. However, the effects of controlling VOL on transcatheter heart valve diameter (THVD) and valve function remain unclear. We assessed associations among VOL, THVD, and effective orifice area (EOA) of S3. METHODS: We enrolled patients undergoing TAVR using 23- and 26-mm S3 in Sendai Kousei Hospital between 2017 and 2019. VOL was controlled based on preprocedural computed tomography and intraprocedural transesophageal echocardiography (TEE). THVD were defined as the diameters of transcatheter heart valve at mid-level measured by TEE. RESULTS: In enrolled 332 patients (23-mm, n = 188; 26-mm, n = 144), one (0.3%) and two (0.6%) developed annulus rupture and moderate/severe paravalvular leak, respectively. VOL at deployment was positively correlated with THVD on deployment (23-mm, r = 0.44, p < 0.001; 26-mm, r = 0.57, p < 0.001) and EOA (23-mm, r = 0.23, p = 0.0019; 26-mm, r = 0.22, p = 0.0094). In multiple regression analyses, VOL and post-dilatation were significant determinants of THVD, although aortic annulus area, calcium volume, and pre-dilatation were not. The areas under the receiver operating characteristic curve that were used to evaluate the accuracy of the index obtained by dividing THVD by body surface area (indexed THVD) to predict patient-prosthesis mismatch (PPM) were 0.744 and 0.811 in the 23- and 26-mm cohorts, respectively. A cut-off indexed THVD of ≤11.5 and 12.1 mm/m2 well predicted PPM (23-mm, odds ratio, 5.20; 95% confidence interval, 1.33-20.3; 26-mm, odds ratio 14.1, 95% confidence interval 2.40-81.0). CONCLUSION: VOL was positively correlated with THVD and EOA. Smaller indexed THVD was associated with a higher incidence of PPM. Controlling VOL under on-site THVD evaluation may be useful in reducing the PPM incidence.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA