Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Surg Endosc ; 38(4): 2288-2296, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38488871

RESUMO

BACKGROUND: Thin delivery system stents can be inserted directly without the need for a tract dilation step and are expected to reduce bile leakage during endoscopic ultrasound-guided biliary drainage (EUS-BD). The present study retrospectively compared the safety and efficacy of EUS-BD using a thin metal stent (< 7.5 Fr) with those of EUS-BD using a conventional stent (≥ 7.5 Fr). METHODS: The present study enrolled 112 patients who underwent EUS-BD using metal stents for unresectable malignant biliary obstruction between April 2016 and July 2022. The primary endpoint was the rate of adverse events (AEs). The secondary endpoints were clinical success rate, procedure time, procedure success rate in the absence of the tract dilation step, recurrent biliary obstruction rate, time to biliary obstruction, and overall survival. Risk factors associated with early AEs were also evaluated. RESULTS: The rate of early AEs was significantly lower (12% vs. 35%, P = 0.013) and the procedure success without the tract dilation step was significantly higher (82% vs. 33%, P < 0.001) in the thin than in the conventional delivery system stent group. None of the other secondary endpoints differed significantly between the two groups. Multivariate analysis showed that employing the tract dilation step during EUS-BD was a significant independent risk factor for early AEs (skipping vs. employing; HR, 9.66; 95% CI, 1.13-83.0, P = 0.028). CONCLUSION: Employing the tract dilation step during EUS-BD was a significant risk factor for early AEs. Metal stents with a delivery diameter < 7.5 Fr can be inserted directly without the tract dilation step, resulting in lower early AE rates.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica , Colestase , Humanos , Estudos Retrospectivos , Colangiopancreatografia Retrógrada Endoscópica/efeitos adversos , Dilatação/efeitos adversos , Colestase/etiologia , Colestase/cirurgia , Endossonografia/métodos , Stents/efeitos adversos , Drenagem/efeitos adversos , Drenagem/métodos , Ultrassonografia de Intervenção/efeitos adversos
2.
Int J Clin Oncol ; 2024 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-38972023

RESUMO

BACKGROUND: Few studies have compared endoscopic ultrasound (EUS)-guided hepaticogastrostomy (HGS) with EUS-guided antegrade metal stent placement (AGMS). The purpose of this study was to compare times to recurrent biliary obstruction (TRBO) in patients who underwent HGS using metal stents (MS) and those who underwent AGMS keeping access routes with plastic stents (AGMS-AR). METHODS: This study retrospectively evaluated consecutive patients who underwent HGS or AGMS between September 2016 and December 2022. TRBO, overall survival (OS), and adverse event (AE) rates were compared in the two groups. The risk factors for RBO were determined using a multivariable Cox proportional hazards model. RESULTS: This study included 32 patients in the HGS group and 30 in the AGMS-AR group. Technical success rate was significantly higher in the HGS than in the AGMS-AR group (100 vs. 80%; P = 0.009). The technical success rate without tract dilation was significantly higher in the AGMS-AR than in the HGS group (83 vs. 38%; P < 0.001). RBO rates were significantly higher in the HGS than in the AGMS-AR group (53 vs. 17%; P = 0.024), whereas AE rates did not differ significantly. TRBO differed significantly in the HGS and AGMS-AR groups (159 days vs. not reached, P = 0.011), whereas OS did not differ significantly. Multivariable analysis revealed that HGS was an independent risk factor for RBO (hazard ratio, 6.48, P = 0.014). CONCLUSION: TRBO was significantly longer in patients who underwent AGMS with PS than HGS. AGMS with PS may be effective after the failure of ERCP in patients with malignant biliary obstruction.

3.
Int J Clin Oncol ; 29(3): 286-296, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38280972

RESUMO

BACKGROUND AND AIMS: Sarcopenia is an important prognostic factor for cancer patients. The aim of this study was to assess the ability of sarcopenia to predict recurrent biliary obstruction (RBO) in patients with unresectable cancer after EUS-guided biliary drainage (EUS-BD). METHODS: The study enrolled 113 patients who underwent EUS-BD using the self-expandable metal stent (SEMS) for unresectable malignant biliary obstruction (MBO) between April 2016 and December 2021 at Wakayama Medical University Hospital. The skeletal muscle index at the third lumbar spine level (L3) was calculated from computed tomography images. We analyzed the cumulative incidence of RBO at 180 days after stent insertion. Univariate and multivariate analyses were performed to identify variables significantly associated with RBO. RESULTS: Seventy-six patients were assigned to the sarcopenia group, and 37 were assigned to the non-sarcopenia group. The 180-day cumulative incidence of RBO was 11% in the non-sarcopenia group and 29% in the sarcopenia group (p = 0.034). The time to RBO was significantly shorter for the sarcopenia group (p = 0.028; Gray's test). Multivariate analyses identified sarcopenia as an independent prognostic factor for RBO (present vs absent; HR 4.61; 95% CI 1.76-12.10, p = 0.001). The rates of biliary sludge/food impaction were significantly higher in the sarcopenia group for the causes of RBO (p = 0.048). There were no significant differences between the sarcopenia and the non-sarcopenia groups with respect to related EUS-BD adverse events. CONCLUSION: Sarcopenia is an independent indicator of RBO in patients with MBO who receive EUS-BD with SEMS.


Assuntos
Colestase , Neoplasias , Sarcopenia , Humanos , Sarcopenia/complicações , Sarcopenia/diagnóstico por imagem , Stents/efeitos adversos , Colestase/diagnóstico por imagem , Colestase/etiologia , Colestase/cirurgia , Neoplasias/complicações , Drenagem/efeitos adversos , Drenagem/métodos
4.
Dig Endosc ; 2024 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-39129171

RESUMO

OBJECTIVES: Detective flow imaging endoscopic ultrasonography (DFI-EUS) is a recent imaging modality developed for detecting fine vessels without the need for ultrasound contrast agents. The aim of the present study was to evaluate the utility of DFI-EUS for solid pancreatic lesions and to compare the diagnostic ability for pancreatic cancer (PC) between DFI-EUS, directional power Doppler (eFLOW) EUS, and contrast-enhanced harmonic (CH)-EUS. METHODS: Patients with a pancreatic lesion who underwent DFI-EUS, eFLOW-EUS, and CH-EUS between March 2019 and November 2023 were retrospectively enrolled. Final diagnoses were confirmed by pathologic examination of EUS-guided tissue acquisition and/or resected specimens. Lesions were categorized into the three patterns of poor, mild, and rich vascularity on DFI-EUS and eFLOW-EUS, and hypo-, iso-, and hypervascular on CH-EUS. PC was defined as a poor pattern on DFI-EUS and eFLOW-EUS, and a hypovascular pattern on CH-EUS. RESULTS: The final diagnoses of 90 examined tumors were PC (n = 57), inflammatory mass (n = 6), autoimmune pancreatitis (n = 13), neuroendocrine tumor (n = 9), and others (n = 5). The sensitivity, specificity, and accuracy for diagnosis of PC were 93%, 82%, and 88%, respectively, on DFI-EUS, 97%, 42%, and 77% on eFLOW-EUS, and 95%, 89%, and 92% on CH-EUS. The accuracy of DFI-EUS was significantly superior to eFLOW-EUS (P = 0.005), but no significant difference was found between DFI-EUS and CH-EUS. CONCLUSION: DFI-EUS is more sensitive for depicting vasculature than eFLOW-EUS, and has higher diagnostic sensitivity for PC. Evaluation of vascularity on DFI-EUS is useful for the differential diagnosis of pancreatic lesions without the need for intravenous contrast agent.

5.
Artigo em Inglês | MEDLINE | ID: mdl-38911353

RESUMO

Endoscopic ultrasound-guided tissue acquisition (EUS-TA), including fine-needle aspiration (EUS-FNA) and fine-needle biopsy (EUS-FNB), has revolutionized specimen collection from intra-abdominal organs, especially the pancreas. Advances in personalized medicine and more precise treatment have increased demands to collect specimens with higher cell counts, while preserving tissue structure, leading to the development of EUS-FNB needles. EUS-FNB has generally replaced EUS-FNA as the procedure of choice for EUS-TA of pancreatic cancer. Various techniques have been tested for their ability to enhance the diagnostic performance of EUS-TA, including multiple methods of sampling at the time of puncture, on-site specimen evaluation, and specimen processing. In addition, advances in next-generation sequencing have made comprehensive genomic profiling of EUS-TA samples feasible in routine clinical practice. The present review describes updates in EUS-TA sampling techniques of pancreatic lesions, as well as methods for their evaluation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA