Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Electrocardiol ; 72: 120-127, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35468456

RESUMO

PURPOSE: Cardiac resynchronization therapy (CRT) reduces ventricular activation times and electrical dyssynchrony, however the effect on repolarization is unclear. In this study, we sought to investigate the effect of CRT and left ventricular (LV) remodeling on dispersion of repolarization using electrocardiographic imaging (ECGi). METHODS: 11 patients with heart failure and electrical dyssynchrony underwent ECGi 1-day and 6-months post CRT. Reconstructed epicardial electrograms were used to create maps of activation time, repolarization time (RT) and activation recovery intervals (ARI) and calculate measures of RT, ARI and their dispersion. ARI was corrected for heart rate (cARI). RESULTS: Compared to baseline rhythm, LV cARI dispersion was significantly higher at 6 months (28.2 ± 7.7 vs 36.4 ± 7.2 ms; P = 0.03) but not after 1 day (28.2 ± 7.7 vs 34.4 ± 6.8 ms; P = 0.12). There were no significant differences from baseline to CRT for mean LV cARI or RT metrics. Significant LV remodeling (>15% reduction in end-systolic volume) was an independent predictor of increase in LV cARI dispersion (P = 0.04) and there was a moderate correlation between the degree of LV remodeling and the relative increase in LV cARI dispersion (R = -0.49) though this was not statistically significant (P = 0.12). CONCLUSION: CRT increases LV cARI dispersion, but this change was not fully apparent until 6 months post implant. The effects of CRT on LV cARI dispersion appeared to be dependent on LV reverse remodeling, which is in keeping with evidence that the risk of ventricular arrhythmia after CRT is higher in non-responders compared to responders.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Disfunção Ventricular Esquerda , Arritmias Cardíacas , Eletrocardiografia , Humanos , Resultado do Tratamento , Remodelação Ventricular/fisiologia
2.
Nature ; 523(7562): 576-9, 2015 07 30.
Artigo em Inglês | MEDLINE | ID: mdl-26223625

RESUMO

Dielectric materials, which store energy electrostatically, are ubiquitous in advanced electronics and electric power systems. Compared to their ceramic counterparts, polymer dielectrics have higher breakdown strengths and greater reliability, are scalable, lightweight and can be shaped into intricate configurations, and are therefore an ideal choice for many power electronics, power conditioning, and pulsed power applications. However, polymer dielectrics are limited to relatively low working temperatures, and thus fail to meet the rising demand for electricity under the extreme conditions present in applications such as hybrid and electric vehicles, aerospace power electronics, and underground oil and gas exploration. Here we describe crosslinked polymer nanocomposites that contain boron nitride nanosheets, the dielectric properties of which are stable over a broad temperature and frequency range. The nanocomposites have outstanding high-voltage capacitive energy storage capabilities at record temperatures (a Weibull breakdown strength of 403 megavolts per metre and a discharged energy density of 1.8 joules per cubic centimetre at 250 degrees Celsius). Their electrical conduction is several orders of magnitude lower than that of existing polymers and their high operating temperatures are attributed to greatly improved thermal conductivity, owing to the presence of the boron nitride nanosheets, which improve heat dissipation compared to pristine polymers (which are inherently susceptible to thermal runaway). Moreover, the polymer nanocomposites are lightweight, photopatternable and mechanically flexible, and have been demonstrated to preserve excellent dielectric and capacitive performance after intensive bending cycles. These findings enable broader applications of organic materials in high-temperature electronics and energy storage devices.

3.
J Electrocardiol ; 68: 117-123, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34416669

RESUMO

AIMS: Electrocardiographic imaging (ECGi) and the ECG belt are body surface potential mapping systems which can assess electrical dyssynchrony in patients undergoing cardiac resynchronization therapy (CRT). ECGi-derived dyssynchrony metrics are calculated from reconstructed epicardial potentials based on body surface potentials combined with a thoracic CT scan, while the ECG belt relies on body surface potentials alone. The relationship between dyssynchrony metrics from these two systems is unknown. In this study we aim to compare intra-ventricular and inter-ventricular dyssynchrony metrics between ECGi and the ECG belt. METHODS: Seventeen patients underwent ECGi after CRT. A subsample of 40 body surface potentials was used to simulate the ECG belt. ECGi dyssynchrony metrics, calculated from reconstructed epicardial potentials, and ECG belt dyssynchrony metrics, calculated from the sampled body surface potentials were compared. RESULTS: There was a strong positive correlation between ECGi left ventricular activation time (LVAT) and ECG belt left thorax activation time (LTAT) (R = 0.88 ; P < 0.001) and between ECGi standard deviation of activation times (SDAT) and ECG belt-SDAT (R = 0.76; P < 0.001) during intrinsic rhythm. The correlation for both pairs was also strong during biventricular pacing. Ventricular electrical uncoupling, a well validated ECGi inter-ventricular dyssynchrony metric, correlated strongly with ECG belt-SDAT during intrinsic rhythm (R = 0.76; P < 0.001) but not biventricular pacing (R = 0.29; P = 0.26). Cranial or caudal displacement of the simulated ECG belt did not affect LTAT or SDAT. CONCLUSION: ECGi- and ECG belt-derived intra-ventricular and inter-ventricular dyssynchrony metrics were strongly correlated. The ECG belt may offer comparable dyssynchrony assessment to ECGi, with associated practical and cost advantages.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Mapeamento Potencial de Superfície Corporal , Eletrocardiografia , Insuficiência Cardíaca/terapia , Ventrículos do Coração/diagnóstico por imagem , Humanos
4.
J Electrocardiol ; 58: 96-102, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31805438

RESUMO

INTRODUCTION: Cardiac resynchronisation therapy (CRT) corrects electrical dyssynchrony. However, the temporal changes in the electrical timing according to substrate are unclear. We used electrocardiographic imaging (ECGi) for serial non-invasive assessment of the underlying electrical substrate and its response to resynchronisation. MATERIAL AND METHODS: ECGi activation maps were constructed 1 day and 6 months post CRT implant. ECGi maps were analysed offline to determine the total ventricular activation time (TVaT) and the time for the bulk of ventricular activation (10th to 90th percentile activation; VaT10-90 Index). Statistical analysis was performed using repeated measures ANOVA with post-hoc pairwise comparisons using paired t-tests. The % relative change within each time point was also calculated and compared between the two time points. RESULTS: Eleven CRT patients were studied. Both total and bulk ventricular activation significantly decreased with CRT turned ON at day 1. Intrinsic (CRT OFF) TVaT and VaT10-90 Index at day 1 were 143 ± 23 and 84 ± 20 ms, respectively, and they significantly decreased post CRT to 115 ± 26 ms (P < 0.001) and 49 ± 17 ms (P < 0.05), respectively. The relative change at day 1 was also statistically significant for TVaT (19 ± 12%, P < 0.001) and VaT10-90 Index (39 ± 25%, P < 0.001). After 6 months, the relative decrease in TVaT with CRT ON remained stable (19% vs. 18% at day 1 and 6 months, respectively) whereas reduction the in VaT10-90 Index was decreased 39% vs. 26% at day 1 and 6 months, respectively. In non-ischaemic patients both total and bulk activation times reduced following CRT. Volumetric responders exhibited an electrical remodelling for bulk activation not apparent in Non-responders, after 6 months of CRT ON. CONCLUSIONS: Intrinsic bulk myocardium activation becomes more rapid and synchronous with CRT. The bulk activation time is more susceptible to improvement by CRT in ischaemic patients and volumetric responders. These observations are consistent with CRT causing reverse electrophysiological remodelling in the bulk myocardium, but not in late-activating ischaemic or fibrotic regions.


Assuntos
Remodelamento Atrial , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Eletrocardiografia , Insuficiência Cardíaca/terapia , Ventrículos do Coração/diagnóstico por imagem , Humanos , Resultado do Tratamento , Remodelação Ventricular
5.
J Cardiovasc Electrophysiol ; 29(12): 1675-1681, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30106206

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) is typically delivered via quadripolar leads that allow stimulation using either true bipolar pacing, where stimulation occurs between two electrodes (BP) on the quadripolar lead, or extended bipole (EBP) left ventricular (LV) pacing, with the quadripolar electrodes and right ventricular coil acting as the cathode and anode, respectively. True bipolar pacing is associated with reductions in mortality and it has been postulated that these differences are the result of enhanced electrical activation. MATERIALS AND METHODS: Patients undergoing a CRT underwent an electrocardiographic imaging study where electrical activation data were recorded while different LV pacing vectors were temporarily programmed. RESULTS: There were no differences in the total electrical activation times or dispersion of electrical activation between biventricular pacing with bipolar or corresponding EBP LV vector configurations (left ventricular total activation time [LVtat] BP 74.70 ± 18.07 vs EBP 72.4 ± 22.64; P = 0.45). When dichotomized according to etiology, no difference was observed in the activation time with either BP or EBP pacing (LVtat BP ischemic cardiomyopathy 72.2 ± 17.4 vs BP dilated cardiomyopathy 79.9 ± 18.9; P = 0.38). CONCLUSIONS: Bipolar pacing alters the mechanical activation sequence of the LV and is associated with reductions in all-cause mortality. It has been postulated these benefits derive from improvements in electromechanical activation of the LV. Our study would suggest that true bipolar pacing does not necessarily result in more favorable activation of the LV or improved electrical resynchronization and other mechanisms should be explored.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Desfibriladores Implantáveis , Cardiopatias/fisiopatologia , Cardiopatias/cirurgia , Função Ventricular Esquerda/fisiologia , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Resultado do Tratamento
6.
Pacing Clin Electrophysiol ; 41(2): 155-160, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29314081

RESUMO

BACKGROUND: A proportion of patients who undergo an initial lead extraction procedure will require a second, repeat extraction. Data regarding this clinical entity are scarce and neither the predisposing risk factors for, nor outcomes from, these procedures have been described previously. We sought to determine the incidence, risk factors, and outcomes of repeat lead extraction. METHODS: A database of extraction procedures from 2001 to 2015 was analyzed. Repeat extraction procedures were identified and the indication for extraction was dichotomized into infection and lead-related problems. Univariate and multivariate analyses were performed to identify predictors of repeat extraction. RESULTS: 807 extraction procedures were identified in 755 patients of whom 6% required a repeat extraction. At multivariate analysis, only suffering a major complication at the initial extraction procedure (odds ratio [OR] 21.5, 95% confidence interval [CI] 2.69-171.92; P < 0.01), complexity of device (cardiac resynchronization devices/implantable cardioverter defibrillators) (OR 2.58, 95% CI 1.2-5.2; P = 0.01), and age (OR 1.02 per year, 95% CI 1.0-1.4; P  =  0.03) were significant predictors of repeat extraction. When repeat extraction was required for infection there was a significant increase in mortality compared with those who did not require a second procedure (36% vs 23%; P  =  0.02). CONCLUSIONS: Repeat lead extraction is required in 6% of cases. Complexity of device, age at extraction, and a major complication at the first extraction were predictors of repeat extraction. Mortality is significantly increased where the repeat procedure is for infection. Clinicians should alert patients to the potential need for further extraction and the increased risks of repeat procedures when indicated for infection.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/métodos , Eletrodos Implantados/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Idoso , Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
7.
J Electrocardiol ; 51(4): 714-719, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29997019

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) is now generally delivered via quadripolar leads. Assessment of the effect of different vector programs from quadripolar leads on ventricular activation can be now done using non-invasive electrocardiographic mapping (ECM). MATERIAL AND METHODS: In nineteen patients with quadripolar LV leads, activation maps were constructed. The total ventricular activation time (TVaT) and the time for the bulk of ventricular activation (VaT10-90) were calculated. RESULTS: CRT delivered via a quadripolar lead significantly reduced TVaT and VaT10-90 by a mean of 16 ms and 31 ms, respectively, compared to baseline. There was a marked reduction in ventricular activation between the most and least synchronous vectors: 28% difference in baseline TVaT and 37% difference in VaT10-90. CONCLUSION: Changes in the configuration of an LV quadripolar lead significantly affected ventricular activation timings in both ischaemic and non-ischaemic subjects. This suggests that programming of the optimal pacing vector may need to be individually tailored.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca/métodos , Eletrocardiografia , Eletrodos Implantados , Insuficiência Cardíaca/terapia , Idoso , Feminino , Insuficiência Cardíaca/fisiopatologia , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
8.
Europace ; 19(6): 1031-1037, 2017 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-27353321

RESUMO

AIMS: Cardiac perforations caused by pacemaker or implantable cardioverter-defibrillator (ICD) leads are uncommon but potentially fatal events. The optimal approach to such cases is unclear. The aim of this study was to identify the optimal imaging modality and management strategy for cardiac perforation. METHODS AND RESULTS: All patients presenting to a single institution with cardiac perforation >24 h since implant between 2011 and 2015 were identified retrospectively. Assessment of the diagnostic performance of pre-extraction chest radiography, transthoracic echocardiography (TTE), and computed tomography (CT) was carried out by blinded review. The method of lead extraction and any associated complications were examined. Eighteen cases of cardiac perforation were identified from 426 lead extraction procedures. Sixteen patients had abnormal electrical parameters at device interrogation. In all cases, the perforating lead was an active fixation model, and in four cases, this was an ICD coil. The accuracy of CT imaging for the diagnosis of cardiac perforation was 92.9%, with sensitivity and specificity of 100 and 85.7%, respectively. This was superior to both TTE (accuracy 62.7%, sensitivity and specificity 41.2 and 84.2%, respectively) and chest radiography (accuracy 61.1%, sensitivity and specificity 27.7 and 94.4%, respectively). Transvenous lead extraction (TLE) was performed in 17 patients, and a hybrid surgical approach in 1 patient. Of those who underwent TLE, there was 100% complete procedural success as per Heart Rhythm Society definitions. CONCLUSION: In the setting of cardiac perforation, CT is the imaging modality of choice. Transvenous lead extraction can be recommended as a safe, efficacious, and versatile intervention.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo , Ecocardiografia , Traumatismos Cardíacos/diagnóstico por imagem , Traumatismos Cardíacos/cirurgia , Doença Iatrogênica , Marca-Passo Artificial/efeitos adversos , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Bases de Dados Factuais , Remoção de Dispositivo/efeitos adversos , Feminino , Traumatismos Cardíacos/etiologia , Humanos , Londres , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Desenho de Prótese , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
9.
J Cardiovasc Electrophysiol ; 27(2): 203-9, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26463874

RESUMO

INTRODUCTION: Many heart failure patients with dyssynchrony do not reverse remodel (RR) in response to cardiac resynchronization therapy (CRT). The presence of focal and diffuse interstitial myocardial fibrosis may explain this high nonresponse rate. T1 mapping is a new cardiac magnetic resonance imaging (CMR) technique that overcomes the limitations of conventional contrast CMR and provides reliable quantitative assessment of diffuse myocardial fibrosis. The study tested the hypothesis that focal and diffuse fibrosis quantification would correlate with a lack of left ventricular (LV) RR to CRT. METHODS AND RESULTS: In a prospective study of 48 consecutive patients (27 ischemic cardiomyopathy, 21 dilated cardiomyopathy) LV scar burdens were quantified (scar core and gray zone using late gadolinium enhancement LGE CMR; interstitial fibrosis using T1 mapping) before CRT implant. LV RR was defined by a ≥ 15% reduction in LV end-systolic volume 6 months postimplant. Twenty-seven (56%) patients were responders with RR. Association between scar quantification and LV RR was assessed using the Poisson regression model. Univariate analysis showed that QRS duration/morphology, scar core, and gray zone volumes expressed as % of LV mass and extracellular volume index (ECV) (a measure of interstitial fibrosis from T1 mapping) to be significant predictors of LV RR. Multivariable-adjusted analyses demonstrated scar core quantification (≥ 13.7% LV mass) to be the only independent predictor of LV RR (prevalence ratio 0.40, P = 0.038). CONCLUSIONS: Focal scar burden detected by LGE CMR is associated with a poor response to CRT. Diffuse interstitial fibrosis assessment by T1 mapping, however, is not independently predictive of CRT response.


Assuntos
Terapia de Ressincronização Cardíaca , Cardiomiopatia Dilatada/patologia , Cicatriz/patologia , Insuficiência Cardíaca/terapia , Imagem Cinética por Ressonância Magnética , Miocárdio/patologia , Função Ventricular Esquerda , Remodelação Ventricular , Idoso , Cardiomiopatia Dilatada/complicações , Cardiomiopatia Dilatada/fisiopatologia , Cicatriz/complicações , Cicatriz/fisiopatologia , Meios de Contraste , Feminino , Fibrose , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/patologia , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Compostos Organometálicos , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Fatores de Tempo , Resultado do Tratamento
10.
Pacing Clin Electrophysiol ; 39(6): 531-41, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27001004

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) with biventricular epicardial (BV-CS) or endocardial left ventricular (LV) stimulation (BV-EN) improves LV hemodynamics. The effect of CRT on right ventricular function is less clear, particularly for BV-EN. Our objective was to compare the simultaneous acute hemodynamic response (AHR) of the right and left ventricles (RV and LV) with BV-CS and BV-EN in order to determine the optimal mode of CRT delivery. METHODS: Nine patients with previously implanted CRT devices successfully underwent a temporary pacing study. Pressure wires measured the simultaneous AHR in both ventricles during different pacing protocols. Conventional epicardial CRT was delivered in LV-only (LV-CS) and BV-CS configurations and compared with BV-EN pacing in multiple locations using a roving decapolar catheter. RESULTS: Best BV-EN (optimal AHR of all LV endocardial pacing sites) produced a significantly greater RV AHR compared with LV-CS and BV-CS pacing (P < 0.05). RV AHR had a significantly increased standard deviation compared to LV AHR (P < 0.05) with a weak correlation between RV and LV AHR (Spearman rs = -0.06). Compromised biventricular optimization, whereby RV AHR was increased at the expense of a smaller decrease in LV AHR, was achieved in 56% of cases, all with BV-EN pacing. CONCLUSIONS: BV-EN pacing produces significant increases in both LV and RV AHR, above that achievable with conventional epicardial pacing. RV AHR cannot be used as a surrogate for optimizing LV AHR; however, compromised biventricular optimization is possible. The beneficial effect of endocardial LV pacing on RV function may have important clinical benefits beyond conventional CRT.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Hemodinâmica , Função Ventricular Esquerda , Função Ventricular Direita , Idoso , Endocárdio , Feminino , Humanos , Masculino
11.
Curr Cardiol Rep ; 18(7): 64, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27216844

RESUMO

Cardiac resynchronization therapy (CRT) reduces the morbidity and mortality of patients with symptomatic heart failure and intraventricular conduction delay. However, its clinical outcomes are non-uniform and up to one third of treated patients are subsequently classified as non-responders. Multisite pacing (MSP), i.e. stimulating the myocardium from multiple locations, has emerged as a potential therapeutic option in patients requiring CRT. The rationale for MSP is based on the hypothesis that increasing the pacing locations in the left ventricle results in a more physiologic and coordinated myocardial systole. MSP can be achieved by additional leads in the right or left ventricle but this can lead to high battery drain and more frequent generator replacements. Multipolar left ventricular leads can deliver pacing at multiple sites, and therefore, a single lead can be used for MSP. However, the optimal programming settings and the outcomes of this approach remain yet to be determined.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/terapia , Terapia de Ressincronização Cardíaca/tendências , Dispositivos de Terapia de Ressincronização Cardíaca , Humanos , Disfunção Ventricular Esquerda/fisiopatologia , Disfunção Ventricular Esquerda/terapia
12.
Practitioner ; 259(1786): 21-4, 2-3, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26738248

RESUMO

Heart failure affects nearly one million people in the UK. Half of these patients have normal, or near normal, left ventricular ejection fraction and are classified as heart failure with preserved ejection fraction (HFpEF). Newer imaging techniques have confirmed that systolic function in HFpEF patients is not completely normal, with reduced long axis function and extensive but subtle changes on exercise. Patients are likely to be older women with a history of hypertension. Other cardiovascular risk factors, such as diabetes mellitus, atrial fibrillation and coronary artery disease are prevalent in the HFpEF population. Clinical symptoms and signs in HFpEF are often nonspecific although the primary symptoms are breathlessness, fatigue and fluid retention. There is still no single diagnostic test for HFpEF and the cornerstone in the assessment remains a thorough medical history and physical examination. The duration and extent of the symptoms are relevant and it is useful to classify patients according to the NYHA functional assessment. Physical examination should include the patient's BMI and weight, heart rate and rhythm, lying and standing blood pressure and auscultation to rule out valvular disease and pulmonary congestion. Estimating the jugular venous pressure and the presence of peripheral oedema allows assessment of the patient's volume status. Patients with heart failure should be referred to heart failure nurses and have follow-up with local cardiology services as these have both been shown to reduce mortality.


Assuntos
Gerenciamento Clínico , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Volume Sistólico/fisiologia , Humanos
13.
PLOS Digit Health ; 2(11): e0000395, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38019808

RESUMO

Materially deprived communities in the UK have excess morbidity and mortality from cardiovascular disease (CVD) but are less likely to engage with formal care pathways. Community engagement and e-health may be more effective ways to promote risk-reducing lifestyle change. The "Healthy Hearts Project" website was designed for use by community health workers (CHWs) for cardiovascular risk assessment and lifestyle goal setting, or for independent use by community members. This paper describes the website's development and evaluation. The website was developed using interactive wire frame prototypes in a user-led approach. Qualitative evaluation of the completed website's usability and acceptability was conducted using the "Thinking Aloud" method in a purposive sample of 10 participants (one voluntary sector employee, three CHWs, two community members and four healthcare professionals). Thinking Aloud interview transcripts were thematically analysed using an inductive approach. A separate quantitative evaluation of usability and the effect of using the website on CVD knowledge and beliefs was conducted. A random sample of 134 participants, recruited using the online platform Prolific, completed the "Attitudes and Beliefs About Cardiovascular Disease" (ABCD) questionnaire before and after using the website, along with the System Usability Scale (SUS). Qualitative evaluation-Four key themes were identified: 1) Website functionality and design-participants generally found the website easy to use and understood the risk communication graphics and the feedback and goal-setting features,; 2) Inclusivity and representation-most participants considered the website inclusive of a range of users/cultures; 3) Language and comprehension-participants found the language used easy to understand but suggested reducing the amount of text; 4) Motivation and barriers to change-participants liked the personalized feedback and empowerment offered by goal-setting but commented on the need for self-motivation. Quantitative evaluation-The mean score across all domains of the ABCD questionnaire (from 2.99 to 3.11, p<0.001) and in the sub-domains relating to attitudes and beliefs around healthy eating and exercise increased after using the website. The mean(sd) score on the SUS was 77.5 (13.5). The website's usability was generally rated well by both quantitative and qualitative measures, and measures of CVD knowledge improved after use. A number of general recommendations for the design of eHealth behaviour change tools are made based on participants' suggestions to improve the website.

16.
Eur Heart J Case Rep ; 5(11): ytab331, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34816081

RESUMO

BACKGROUND: LMNA cardiomyopathy is a cause of dilated cardiomyopathy (DCM) characterized by aggressive heart failure, high risk of arrhythmias, and sudden cardiac death. We present a case of a male presenting with an LMNA mutation with an aggressive DCM leading to sudden cardiac death (SCD). CASE SUMMARY: A 42-year-old male presented with the feeling of lethargy and intermittent dizziness. Electrocardiogram demonstrated atrioventricular block in keeping with Mobitz type 1, at a rate of 40 b.p.m. and cardiac monitoring showed non-sustained ventricular tachycardia. Cardiac magnetic resonance imaging showed preserved left ventricular (LV) ejection function (59%) but features suggesting DCM. These included mild LV dilatation with an end diastolic volume (EDV) of 213 mL and late enhancement showing a single mid myocardial focus of high signal over the distal right ventricular insertion point inferiorly and a linear area of high signal over the basal septum. After discussion at the cardiology multi-disciplinary meeting, a pacemaker was implanted so that beta-blockers could be initiated to suppress the ventricular arrhythmias. A laminopathy was suspected and if this was confirmed from genetic testing the plan was to upgrade to an implantable defibrillator. Due to stability, this was decided to be done in an outpatient setting. He unfortunately had an out-of-hospital VF arrest and died. Post-mortem showed subtle cardiomyopathy in keeping with a DCM. Genetic tests results were returned a few months later which confirmed a pathogenic variant in LMNA. DISCUSSION: Because of the complexity of LMNA-related cardiac disease, they should be managed and followed up in centres with special expertise in inherited cardiomyopathy.

17.
JACC Cardiovasc Imaging ; 14(12): 2275-2285, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34886993

RESUMO

OBJECTIVES: The aim of this study was to examine the value of first-phase ejection fraction (EF1), to predict response to cardiac resynchronization therapy (CRT) and clinical outcomes after CRT. BACKGROUND: CRT is an important treatment for patients with chronic heart failure. However, even in carefully selected cases, up to 40% of patients fail to respond. EF1, the ejection fraction up to the time of maximal ventricular contraction, is a novel sensitive echocardiographic measure of early systolic function and might relate to response to CRT. METHODS: An initial retrospective study was performed in 197 patients who underwent CRT between 2009 and 2018 and were followed to determine clinical outcomes at King's Health Partners in London. A validation study (n = 100) was performed in patients undergoing CRT at Barts Heart Centre in London. RESULTS: Volumetric response rate (reduction in end-systolic volume ≥15%) was 92.3% and 12.1% for those with EF1 in the highest and lowest tertiles (P < 0.001). A cutoff value of 11.9% for EF1 had >85% sensitivity and specificity for prediction of response to CRT; on multivariate binary logistic regression analysis incorporating previously defined predictors, EF1 was the strongest predictor of response (odds ratio [OR]: 1.56 per 1% change in EF1; 95% CI: 1.37-1.78; P < 0.001). EF1 was also the strongest predictor of improvement in clinical composite score (OR: 1.11; 95% CI: 1.04-1.19; P = 0.001). Improvement in EF1 at 6 months after CRT implantation (6.5% ± 5.8% vs 1.8% ± 4.3% in responders vs nonresponders; P < 0.001) was the best predictor of heart failure rehospitalization and death after median follow-up period of 20.3 months (HR: 0.81; 95% CI: 0.73-0.90; P < 0.001). In the validation cohort, EF1 was a similarly 1strong predictor of response (OR: 1.45; 95% CI: 1.23-1.70; P < 0.001) as in the original cohort. CONCLUSIONS: EF1 is a promising marker to identify patients likely to respond to CRT.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Humanos , Valor Preditivo dos Testes , Estudos Retrospectivos , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
18.
Mar Environ Res ; 172: 105489, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34619503

RESUMO

Aquatic ecosystems face numerous anthropogenic threats associated with coastal urbanization, with boat activity being among the most prevalent. The present study aimed to evaluate a potential relationship between boat activity and shark space use in Biscayne Bay, Florida (USA), a coastal waterway exposed to high levels of boating. Spatiotemporal patterns in boat density and traffic were determined from aerial surveys and underwater acoustic recorders, respectively. These data were then compared with residency patterns of bull (Carcharhinus leucas), nurse (Ginglymostoma cirratum) and great hammerhead (Sphyrna mokarran) sharks quantified through passive acoustic telemetry. Results were mixed, with no detectable relationship between boat density and shark residency for any of the species. Hourly presence of G. cirratum decreased with increasing boat traffic, a relationship not seen in the other two species. Explanations for these results include habituation of sharks to the high levels of chronic boat activity in the study area and interspecific differences in hearing sensitivity.


Assuntos
Tubarões , Animais , Ecossistema , Florida , Navios , Telemetria
19.
Heart Rhythm O2 ; 2(4): 365-373, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34430942

RESUMO

BACKGROUND: Patients who improve following cardiac resynchronization therapy (CRT) have left ventricular (LV) remodeling and improved cardiac output (CO). Effects on the systemic circulation are unknown. OBJECTIVE: To explore the effects of CRT on aortic and pulmonary blood flow and systemic afterload. METHODS: At CRT implant patients underwent a noninvasive assessment of central hemodynamics, including wave intensity analysis (n = 28). This was repeated at 6 months after CRT. A subsample (n = 11) underwent an invasive electrophysiological and hemodynamic assessment immediately following CRT. CRT response was defined as reduction in LV end-systolic volume ≥15% at 6 months. RESULTS: In CRT responders (75% of those in the noninvasive arm), there was a significant increase in CO (from 3 ± 2 L/min to 4 ± 2 L/min, P = .002) and LV dP/dtmax (from 846 ± 162 mm Hg/s to 958 ± 194 mm Hg/s, P = .001), immediately after CRT in those in the invasive arm. They demonstrated a significant increase in aortic forward compression wave (FCW) both acutely and at follow-up. The relative change in LV dP/dtmax strongly correlated with changes in the aortic FCW (R s 0.733, P = .025). CRT responders displayed a significant reduction in afterload, and a decrease in systemic vascular resistance and pulse wave velocity acutely; there was a significant decrease in acute pulmonary afterload measured by the pulmonary FCW and forward expansion wave. CONCLUSION: Improved cardiac function following CRT is attributable to a combination of changes in the cardiac and cardiovascular system. The relative importance of these 2 mechanisms may then be important for optimizing CRT.

20.
Cardiol Res Pract ; 2019: 4351693, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30918721

RESUMO

STUDY HYPOTHESIS: We sought to investigate the association between echocardiographic optimisation and ventricular activation time in cardiac resynchronisation therapy (CRT) patients, obtained through the use of electrocardiographic mapping (ECM). We hypothesised that echocardiographic optimisation of the pacing delay between the atrial and ventricular leads-atrioventricular delay (AVD)-and the delay between ventricular leads-interventricular pacing interval (VVD)-would correlate with reductions in ventricular activation time. BACKGROUND: Optimisation of AVD and VVD may improve CRT patient outcome. Optimal delays are currently set based on echocardiographic indices; however, acute studies have found that reductions in bulk ventricular activation time correlate with improvements in acute haemodynamic performance. MATERIALS AND METHODS: Twenty-one patients with established CRT criteria were recruited. After implantation, patients underwent echo-guided optimisation of the AVD and VVD. During this procedure, the participants also underwent noninvasive ECM. ECM maps were constructed for each AVD and VVD. ECM maps were analysed offline. Total ventricular activation time (TVaT) and a ventricular activation time index (VaT10-90) were calculated to identify the optimal AVD and VVD timings that gave the minimal TVaT and VaT10-90 values. We correlated cardiac output with these electrical timings. RESULTS: Echocardiographic programming optimisation was not associated with the greatest reductions in biventricular activation time (VaT10-90 and TVaT). Instead, bulk activation times were reduced by a further 20% when optimised with ECM. A significant inverse correlation was identified between reductions in bulk ventricular activation time and improvements in LVOT VTI (p < 0.001), suggesting that improved ventricular haemodynamics are a sequelae of more rapid ventricular activation. CONCLUSIONS: EAM-guided programming optimisation may achieve superior fusion of activation wave fronts leading to improvements in CRT response.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA