Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 32(6): 1584-1593, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33772926

RESUMO

BACKGROUND: The assessment of noninvasive markers of left atrial (LA) low-voltage substrate (LVS) enables the identification of atrial fibrillation (AF) patients at risk for arrhythmia recurrence after pulmonary vein isolation (PVI). METHODS: In this prospective multicenter study, 292 consecutive AF patients (72% male, 62 ± 11 years, 65% persistent AF) underwent high-density LA voltage mapping in sinus rhythm. LA-LVS (<0.5 mV) was considered as significant at 2 cm2  or above. Preprocedural clinical electrocardiogram and echocardiographic data were assessed to identify predictors of LA-LVS. The role of the identified LA-LVS markers in predicting 1-year arrhythmia freedom after PVI was assessed in 245 patients. RESULTS: Significant LA-LVS was identified in 123 (42%) patients. The amplified sinus P-wave duration (APWD) best predicted LA-LVS, with a 148-ms value providing the best-balanced sensitivity (0.81) and specificity (0.88). An APWD over 160 ms was associated with LA-LVS in 96% of patients, whereas an APWD under 145 ms in 15%. Remaining gray zones improved their accuracy by introduction of systolic pulmonary artery pressure (sPAP) of 35 mmHg or above, age, and sex. According to COX regression, the risk of arrhythmia recurrence 12 months following PVI was twofold and threefold higher in patients with APWD 145-160 and over 160 ms, compared to APWD under 145 ms. Integration of pulmonary hypertension further improved the outcome prediction in the intermediate APWD group: Patients with APWD 145-160 ms and normal sPAP had similar outcome than patients with APWD under 145 ms (hazard ratio [HR] 1.62, p = .14), whereas high sPAP implied worse outcome (HR 2.56, p < .001). CONCLUSIONS: The APWD identifies LA-LVS and risk for arrhythmia recurrence after PVI. Our prediction model becomes optimized by means of integration of the pulmonary artery pressure.


Assuntos
Fibrilação Atrial , Remodelamento Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ecocardiografia , Eletrocardiografia , Feminino , Átrios do Coração/diagnóstico por imagem , Humanos , Masculino , Estudos Prospectivos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
2.
Europace ; 20(2): 279-287, 2018 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-28011800

RESUMO

Aims: The number of pulmonary vein isolation (PVI) ablation procedures is steadily increasing worldwide resulting in a substantial radiation exposure to patients and operators. The aim of our study was to reduce radiation exposure during these procedures to a critical amount without compromising patient safety. Methods and results: First, we assessed radiation exposure for primary PVI procedures over time (2005-2015) at the University Heart Center Freiburg-Bad Krozingen. Second, we prospectively evaluated in 52 patients, the efficacy and safety of a novel radiation reduction program (particularly applying an enhanced fluoroscopy pulse dose-reduction and optimized 3D-mapping system use). In 2035 primary PVI procedures, radiation exposure, assessed as estimated effective dose (eED in mSv, dose area product * 0.002 * conversion factor for females), fluoroscopy-time, and procedure-time decreased significantly from 2005 to 2015 (e.g. eED decreased from 9.3 (interquartile range (IQR) 6.4-13.4) mSv to 0.9 (IQR 0.5-1.6) mSv, p for trend <0.001). Importantly, application of the enhanced radiation reduction program further reduced eED to 0.4 mSv (IQR 0.3-0.6, P < 0.001 vs. control), a value not significantly different from slow-pathway ablation procedures (P = 0.41). Multiple linear regression analysis identified the radiation reduction program as the only independent variable associated with a decrease in radiation exposure. Conclusion: Radiation exposure during PVI decreased over the last decade and can further be reduced significantly by the implementation of an enhanced radiation reduction program.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Doses de Radiação , Exposição à Radiação/prevenção & controle , Radiografia Intervencionista , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Feminino , Alemanha , Humanos , Masculino , Pessoa de Meia-Idade , Avaliação de Programas e Projetos de Saúde , Estudos Prospectivos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/fisiopatologia , Exposição à Radiação/efeitos adversos , Radiografia Intervencionista/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
3.
Radiology ; 275(3): 683-91, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25559233

RESUMO

PURPOSE: To evaluate an automated method for the quantification of fat in the right ventricular (RV) free wall on multidetector computed tomography (CT) images and assess its diagnostic value in arrhythmogenic RV cardiomyopathy (ARVC). MATERIALS AND METHODS: This study was approved by the institutional review board, and all patients gave informed consent. Thirty-six patients with ARVC (mean age ± standard deviation, 46 years ± 15; seven women) were compared with 36 age- and sex-matched subjects with no structural heart disease (control group), as well as 36 patients with ischemic cardiomyopathy (ischemic group). Patients underwent contrast material-enhanced electrocardiography-gated cardiac multidetector CT. A 2-mm-thick RV free wall layer was automatically segmented and myocardial fat, expressed as percentage of RV free wall, was quantified as pixels with attenuation less than -10 HU. Patient-specific segmentations were registered to a template to study fat distribution. Receiver operating characteristic (ROC) analysis was performed to assess the diagnostic value of fat quantification by using task force criteria as a reference. RESULTS: Fat extent was 16.5% ± 6.1 in ARVC and 4.6% ± 2.7 in non-ARVC (P < .0001). No significant difference was observed between control and ischemic groups (P = .23). A fat extent threshold of 8.5% of RV free wall was used to diagnose ARVC with 94% sensitivity (95% confidence interval [CI]: 82%, 98%) and 92% specificity (95% CI: 83%, 96%). This diagnostic performance was higher than the one for RV volume (mean area under the ROC curve, 0.96 ± 0.02 vs 0.88 ± 0.04; P = .009). In patients with ARVC, fat correlated to RV volume (R = 0.63, P < .0001), RV function (R = -0.67, P = .001), epsilon waves (R = 0.39, P = .02), inverted T waves in V1-V3 (R = 0.38, P = .02), and presence of PKP2 mutations (R = 0.59, P = .02). Fat distribution differed between patients with ARVC and those without, with posterolateral RV wall being the most ARVC-specific area. CONCLUSION: Automated quantification of RV myocardial fat on multidetector CT images is feasible and performs better than RV volume in the diagnosis of ARVC. Online supplemental material is available for this article.


Assuntos
Tecido Adiposo/patologia , Displasia Arritmogênica Ventricular Direita/diagnóstico por imagem , Meios de Contraste , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Tomografia Computadorizada Multidetectores , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
4.
J Cardiovasc Electrophysiol ; 25(7): 701-8, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24575734

RESUMO

INTRODUCTION: Pulmonary vein reconnection (PVR) is an important cause of AF recurrence after ablation. With the advent of force sensing catheters, catheter-tissue contact can be determined quantitatively. Since contact force (CF) plays a major role in determining the characteristics of RF lesion, we prospectively assessed the mechanisms of PVR with regard to catheter-contact and lesion distances in patients undergoing AF ablation. METHODS AND RESULTS: Forty symptomatic AF patients underwent wide circumferential PV isolation (PVI) with SmartTouch™ CF catheter. The exact locations of acute PVI and spontaneous or adenosine-provoked PVR were annotated on CARTO. One thousand nine hundred and twenty-six RF lesions isolated 153 PVs. PVR occurred in 35 (23%) PVs: 22 (63%) adenosine-provoked and 13 (37%) spontaneous. CF was significantly lower at PVR versus PVI sites for RF lesions within 6 mm from these sites: mean CF 5 versus 11 g (P < 0.0001) and force-time integral (FTI) 225 versus 415 gs (P < 0.0001); 86% of PVR occurred with a mean CF < 10 g (FTI < 400 gs); and the remaining 14% occurred at ablation sites with a long interlesion distance (≥5 mm) despite mean CF ≥ 10 g. Eighty percent of PVR sites were located anteriorly. There were no significant differences in regard to arrhythmia freedom between the patients without (69%) versus with PVR (67%; P = 1.0). CONCLUSIONS: Acutely durable PVI can be achieved when RF lesions are delivered with a mean CF ≥ 10 g and an interlesion distance <5 mm. The majority of PVR occur anteriorly due to inadequate CF or long interlesion distances.


Assuntos
Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/efeitos adversos , Ablação por Cateter/efeitos adversos , Veias Pulmonares/cirurgia , Adenosina , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Recidiva , Fatores de Tempo , Transdutores de Pressão , Resultado do Tratamento
5.
J Cardiovasc Electrophysiol ; 25(5): 479-484, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24384060

RESUMO

BACKGROUND: Transseptal puncture (TP) is a prerequisite for LA ablations. LA access can be gained by catheter probing in case of PFO (trans-PFO method) or puncture of the interatrial septum (IAS) using a transseptal needle. A 2nd access can again be gained via PFO, a 2nd TP or catheter probing of the previous puncture site (probe-TS method). This study investigates the risk factors and complications related to the mode of transseptal access. METHODS AND RESULTS: From August 2010 to August 2012, a total of 544 LA ablations, were performed. The mode of LA access was either a double TP or a single TP followed by the probe-TS or the trans-PFO method, respectively. TP was always guided by TEE and was successfully performed without complications in all cases. In contrast, 6/410 patients (1.5%) in whom catheter probing was performed (probe-TS, n = 4, trans-PFO, n = 2) had a dissection of the superior IAS originating from inside the oval fossa (n = 5) or perforation above the oval fossa (n = 1). Perforation into the pericardial space occurred in 4/6 patients, leading to one cardiac tamponade. In 5/6 patients, LA ablation was successfully completed, after repeated TP, despite effective anticoagulation. Patients with complications had the following characteristics: LA size 46 ± 4 mm, persistent AF (5/6), a repeat transseptal procedure (3/6) and a right-sided pouch (RSP, 5/6). CONCLUSIONS: Interatrial septum dissection/perforation, occasionally with perforation into the pericardial space, is an unreported complication of TP, especially with the catheter-probing techniques. An RSP is an unrecognized risk factor in this context and can be visualized by TEE.


Assuntos
Fibrilação Atrial/cirurgia , Flutter Atrial/cirurgia , Septo Interatrial , Cateterismo Cardíaco/métodos , Ablação por Cateter/métodos , Átrios do Coração/cirurgia , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Flutter Atrial/diagnóstico , Flutter Atrial/fisiopatologia , Septo Interatrial/diagnóstico por imagem , Septo Interatrial/lesões , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Tamponamento Cardíaco/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/instrumentação , Ecocardiografia Doppler em Cores , Ecocardiografia Transesofagiana , Feminino , Forame Oval Patente/diagnóstico por imagem , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Traumatismos Cardíacos/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Punções , Radiografia Intervencionista , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Resultado do Tratamento
6.
Circulation ; 125(18): 2184-96, 2012 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-22492578

RESUMO

BACKGROUND: Catheter ablation of ventricular tachycardia (VT) is effective and particularly useful in patients with frequent defibrillator interventions. Various substrate modification techniques have been described for unmappable or hemodynamically intolerable VT. Noninducibility is the most frequently used end point but is associated with significant limitations, so the optimal end point remains unclear. We hypothesized that elimination of local abnormal ventricular activities (LAVAs) during sinus rhythm or ventricular pacing would be a useful and effective end point for substrate-based VT ablation. As an adjunct to this strategy, we used a new high-density mapping catheter and frequently used epicardial mapping. METHODS AND RESULTS: Seventy patients (age, 67±11 years; 7 female) with VT and structurally abnormal ventricle(s) were prospectively enrolled. Conventional mapping was performed in sinus rhythm in all, and a high-density Pentaray mapping catheter was used in the endocardium (n=35) and epicardially. LAVAs were recorded in 67 patients (95.7%; 95% confidence interval, 89.2-98.9). Catheter ablation was performed targeting LAVA with an irrigated-tip catheter placed endocardially via a transseptal or retrograde aortic approach or epicardially via the subxiphoid approach. LAVAs were successfully abolished or dissociated in 47 of 67 patients (70.1%; 95% confidence interval, 58.7-80.1). In multivariate analysis, LAVA elimination was independently associated with a reduction in recurrent VT or death (hazard ratio, 0.49; 95% confidence interval, 0.26-0.95; P=0.035) during long-term follow-up (median, 22 months). CONCLUSIONS: LAVAs can be identified in most patients with scar-related VT. Elimination of LAVAs is feasible and safe and is associated with superior survival free from recurrent VT.


Assuntos
Ablação por Cateter/métodos , Fibrilação Ventricular/cirurgia , Idoso , Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/instrumentação , Cicatriz/cirurgia , Mapeamento Epicárdico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação/instrumentação , Reoperação/métodos , Resultado do Tratamento , Fibrilação Ventricular/mortalidade
7.
J Cardiovasc Electrophysiol ; 24(12): 1328-35, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23889915

RESUMO

INTRODUCTION: Irrigated tip radiofrequency (RF) catheter ablation is the most frequently used technology for pulmonary vein isolation (PVI). The purpose of this study was to compare the efficiency and the safety of 2 different open irrigated tip RF ablation catheters. METHODS AND RESULTS: A total of 160 patients with symptomatic AF (29% persistent, 68% male, 61 ± 10 years) were randomized to circumferential PVI using 2 different irrigated tip catheters: (1) the novel Thermocool SF(®) with a porous tip (56 holes) or (2) the Thermocool(®) catheter with 6 irrigation holes at the distal tip in both power- and temperature-controlled modes. PVI procedural time and RF duration were significantly shorter with SF(®) versus Thermocool(®) catheter: 104.5 versus 114 minutes (P = 0.023) and 35.4 minutes versus 39.9 minutes (P < 0.001), respectively. Similarly, the total fluoroscopy time and dose were shorter with SF(®) versus. Thermocool(®) catheter: 21 minutes versus 24 minutes (P = 0.02) and 1014.5 µGy*m(2) versus 1377 µGy*m(2) (P < 0.0001), respectively. Irrigation volume was lower with SF(®): 600 mL versus 1100 mL, (P < 0.0001) and the rates of complications were not significantly different (0.6% vs 0.49%, P = 0.66). At 20.5 ± 7.5 months follow-up, there were no significant differences with regard to arrhythmia freedom between SF(®) (59.2%) and TC® groups (59.3%), (P = 0.61). CONCLUSIONS: Using the novel irrigated tip SF catheter, PVI is achieved within a shorter ablation and procedural durations. The underlying mechanisms and potential differences in RF lesion size remain to be elucidated.


Assuntos
Fibrilação Atrial/cirurgia , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Veias Pulmonares/cirurgia , Irrigação Terapêutica/instrumentação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Desenho de Equipamento , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Porosidade , Estudos Prospectivos , Veias Pulmonares/fisiopatologia , Doses de Radiação , Radiografia Intervencionista/métodos , Fatores de Tempo , Resultado do Tratamento
8.
Front Cardiovasc Med ; 10: 1110165, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37051067

RESUMO

Introduction: Outcomes of catheter ablation for non-paroxysmal atrial fibrillation (AF) remain suboptimal. Non-invasive stratification of patients based on the presence of atrial cardiomyopathy (ACM) could allow to identify the best responders to pulmonary vein isolation (PVI). Methods: Observational multicentre retrospective study in patients undergoing cryoballoon-PVI for non-paroxysmal AF. The duration of amplified P-wave (APW) was measured from a digitally recorded 12-lead electrocardiogram during the procedure. If patients were in AF, direct-current cardioversion was performed to allow APW measurement in sinus rhythm. An APW cut-off of 150 ms was used to identify patients with significant ACM. We assessed freedom from arrhythmia recurrence at long-term follow-up in patients with APW ≥ 150 ms vs. APW < 150 ms. Results: We included 295 patients (mean age 62.3 ± 10.6), of whom 193 (65.4%) suffered from persistent AF and the remaining 102 (34.6%) from long-standing persistent AF. One-hundred-forty-two patients (50.2%) experienced arrhythmia recurrence during a mean follow-up of 793 ± 604 days. Patients with APW ≥ 150 ms had a significantly higher recurrence rate post ablation compared to those with APW < 150 ms (57.0% vs. 41.6%; log-rank p < 0.001). On a multivariable Cox-regression analysis, APW≥150 ms was the only independent predictor of arrhythmia recurrence post ablation (HR 2.03 CI95% 1.28-3.21; p = 0.002). Conclusion: APW duration predicts arrhythmia recurrence post cryoballoon-PVI in persistent and long-standing persistent AF. An APW cut-off of 150 ms allows to identify patients with significant ACM who have worse outcomes post PVI. Analysis of APW represents an easy, non-invasive and highly reproducible diagnostic tool which allows to identify patients who are the most likely to benefit from PVI-only approach.

9.
J Cardiovasc Electrophysiol ; 23(7): 697-707, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22429828

RESUMO

INTRODUCTION: Persistent atrial fibrillation (AF) ablation may lead to partial disconnection of the coronary sinus (CS). As a result, disparate activation sequences of the local CS versus contiguous left atrium (LA) may be observed during atrial tachycardia (AT). We aimed to evaluate the prevalence of this phenomenon and its impact on activation mapping. METHODS: AT occurring after persistent AF ablation were investigated in 74 consecutive patients. Partial CS disconnection during AT was suspected when double potentials with disparate activation sequences were observed on the CS catheter. Endocardial mapping facing CS bipoles was performed to differentiate LA far-field from local CS potentials. RESULTS: A total of 149 ATs were observed. Disparate LA-CS activations were apparent in 20 ATs after magnifying the recording scale (13%). The most common pattern (90%) was distal to proximal endocardial LA activation against proximal to distal CS activation, the latter involving the whole CS or its distal part. Perimitral macroreentry was more common when disparate LA-CS activations were observed (67% vs 29%; P = 0.002). Partial CS disconnection also resulted in "pseudo" mitral isthmus (MI) block during LA appendage pacing in 20% of patients as local CS activation was proximal to distal despite distal to proximal activation of the contiguous LA. CONCLUSION: Careful analysis of CS recordings during AT following persistent AF ablation often reveals disparate patterns of activation. Recognizing when endocardial LA activation occurs in the opposite direction to the more obvious local CS signals is critical to avoid misleading interpretations during mapping of AT and evaluation of MI block.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Seio Coronário/fisiopatologia , Taquicardia Supraventricular/diagnóstico , Imagens com Corantes Sensíveis à Voltagem , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Estimulação Cardíaca Artificial , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Feminino , França , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prevalência , Taquicardia Supraventricular/epidemiologia , Taquicardia Supraventricular/fisiopatologia , Fatores de Tempo
10.
J Cardiovasc Electrophysiol ; 23(5): 489-96, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22229972

RESUMO

OBJECTIVE: To evaluate the safety and outcomes of mitral isthmus (MI) linear ablation with temporary spot occlusion of the coronary sinus (CS). BACKGROUND: CS blood flow cools local tissue precluding transmurality and bidirectional block across MI lesion. METHODS: In a randomized, controlled trial (CS-occlusion = 20, Control = 22), MI ablation was performed during continuous CS pacing to monitor the moment of block. CS was occluded at the ablation site using 1 cm spherical balloon, Swan-Ganz catheter with angiographic confirmation. Ablation was started at posterior mitral annulus and continued up to left inferior pulmonary vein (LIPV) ostium using an irrigated-tip catheter. If block was achieved, balloon was deflated and linear block confirmed. If not, additional ablation was performed epicardially (power ≤25 W). Ablation was abandoned after ∼30 minutes, if block was not achieved. RESULTS: CS occlusion (mean duration -27 ± 9 minutes) was achieved in all cases. Complete MI block was achieved in 13/20 (65%) and 15/22 (68%) patients in the CS-occlusion and control arms, respectively, P = 0.76. Block was achieved with significantly small number (0.5 ± 0.8 vs 1.9 ± 1.1, P = 0.0008) and duration (1.2 ± 1.7 vs 4.2 ± 3.5 minutes, P = 0.009) of epicardial radiofrequency (RF) applications and significantly lower amount of epicardial energy (1.3 ± 2.4 vs 6.3 ± 5.7 kJ, P = 0.006) in the CS-occlusion versus control arm, respectively. There was no difference in total RF (22 ± 9 vs 23 ± 11 minutes, P = 0.76), procedural (36 ± 16 vs 39 ± 20 minutes, P = 0.57), and fluoroscopic (13 ± 7 vs 15 ± 10 minutes, P = 0.46) durations for MI ablation between the 2 arms. Clinically uneventful CS dissection occurred in 1 patient CONCLUSIONS: Temporary spot occlusion of CS is safe and significantly reduces the requirement of epicardial ablation to achieve MI block. It does not improve overall procedural success rate and procedural duration. Tissue cooling by CS blood flow is just one of the several challenges in MI ablation.


Assuntos
Fibrilação Atrial/cirurgia , Oclusão com Balão , Ablação por Cateter , Seio Coronário , Valva Mitral/cirurgia , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Oclusão com Balão/efeitos adversos , Ablação por Cateter/efeitos adversos , Distribuição de Qui-Quadrado , Angiografia Coronária , Seio Coronário/diagnóstico por imagem , Técnicas Eletrofisiológicas Cardíacas , Estudos de Viabilidade , Feminino , França , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
11.
JACC Clin Electrophysiol ; 8(9): 1067-1076, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35780035

RESUMO

BACKGROUND: The Octaray (Biosense Webster) is a novel, multispline mapping catheter with 48 closely spaced microelectrodes enabling high-resolution electroanatomical mapping. OBJECTIVES: This study sought to report the initial clinical mapping experience with this novel catheter in a variety of cardiac arrhythmias and to compare the mapping performance with the 5-spline Pentaray. METHODS: Fifty consecutive procedures among 46 patients were retrospectively analyzed regarding safety, efficacy, and acute procedural success defined as termination or noninducibility of clinical tachycardia, conduction block across an ablation line, or pulmonary vein isolation. In addition, another 10 patients with sustained atrial tachycardia mapped with the 5-spline catheter (2-5-2 spacing) or the novel 8-spline catheter (2-2-2-2-2 spacing) were analyzed. RESULTS: Left atrial and ventricular mapping by either transseptal (n = 41) or retroaortic (n = 2) access was feasible without any complications related to the multispline design of the novel catheter. The acute procedural success rate was 94%. In sustained atrial tachycardia compared with the 5-spline catheter, the novel 8-spline catheter recorded more electrograms per map (3,628 ± 714 vs 11,350 ± 1,203; P < 0.001) in a shorter mapping time (13 ± 2 vs 9 ± 1 minutes; P = 0.08) resulting in a higher point density (18 ± 4 vs 59 ± 10 electrograms/cm2; P < 0.01) and point acquisition rate (308 ± 69 vs 1,332 ± 208 electrograms/min.; P < 0.01). CONCLUSIONS: In this initial experience, mapping with the novel catheter was safe and efficient with a high electroanatomical resolution. In sustained atrial tachycardia the novel 8-spline catheter demonstrated a marked increase in point density and mapping speed compared with those of the 5-spline catheter. These initial results should be validated in a larger multicenter cohort with longer follow-up.


Assuntos
Ablação por Cateter , Veias Pulmonares , Taquicardia Supraventricular , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Catéteres , Humanos , Veias Pulmonares/cirurgia , Estudos Retrospectivos , Taquicardia Supraventricular/cirurgia
12.
J Cardiovasc Electrophysiol ; 22(11): 1217-23, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21668561

RESUMO

BACKGROUND: Achievement of complete conduction block across left mitral isthmus (MI) is a challenging endpoint of linear lesion, and recognizing the precise moment of block is important during ongoing ablation. The objective of this study is to evaluate the changes in P wave morphology and local MI potential at the moment of block during ongoing radiofrequency (RF) application. METHODS AND RESULTS: We evaluated 69 patients (procedures) in whom successful MI linear conduction block was achieved during coronary sinus (CS) pacing. P wave morphology and/or local MI potential could be evaluated in 64 (93%) and 69 (100%) procedures, respectively. The achievement of MI block was associated with substantial instantaneous changes in 57/69 (82.6%) procedures. P wave morphology changed in 44 (64%) procedures with the change restricted to lateral leads in 39 (57%). Abrupt prolongation of local conduction delay from 106 ± 24 ms to 167 ± 39 ms (P < 0.0001) was observed on proximal bipole of ablation catheter in 34/69 (49.3%) procedures during ongoing RF application. In addition, prolongation of conduction delay was associated with significant change in the electrogram amplitude and polarity in 11 and 19 procedures, respectively. The substantial change in P wave morphology was not observed in any patients without achievement of complete block. CONCLUSIONS: The achievement of conduction block across MI line is associated with recognizable changes in the local MI electrograms and the P wave morphology especially in the lateral leads. These instantaneous critical changes may assist catheter ablation and indicate the requirement for prolonged RF application, if necessary.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Valva Mitral/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Mapeamento Epicárdico , Feminino , França , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/fisiopatologia , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
13.
J Cardiovasc Electrophysiol ; 22(8): 846-50, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21288279

RESUMO

INTRODUCTION: We investigated the impact of the mode of left atrial (LA) access via patent foramen ovale (PFO) versus transseptal (TS) puncture on LA linear lesions during atrial fibrillation (AF) ablation. METHODS AND RESULTS: We investigated 139 (PFO: 25) consecutive patients who underwent mitral isthmus (MI) and/or LA roof linear ablation. Technical endpoint was completeness of linear lesions and duration of radiofrequency (RF) application. During the initial procedure, complete MI and LA roof blocks were created in 13 of 19 (68%) and 14 of 17 (82%) patients in the PFO group, and in 57 of 94 (61%) and 54 of 70 (74%) patients in the TS group, respectively (P = NS). There was no significant difference in RF durations at MI (11.1 ± 8.9 and 15.1 ± 7.6 minutes, P = 0.11), and LA roof (10.1 ± 3.5 and 8.3 ± 5.0 minutes, P = 0.21) between the 2 groups. Among 28 patients who underwent repeat linear ablation, complete MI and LA roof blocks were created in 3 of 4 (75%) and 0 of 1 (0%) patients in the PFO group, and in 16 of 21 (76%) and 7 of 10 (70%) patients in the TS group, respectively (P = NS). There was no significant difference in RF durations at MI (15.3 ± 8.3 and 19.5 ± 18.3 minutes, P = 0.71), and LA roof (19.0 and 10.3 ± 5.4 minutes, P = 0.19) between the 2 groups. Clinical outcomes at 12 months were also similar. CONCLUSION: There were no significant differences in the procedural success rates, durations of RF application, 12-month clinical outcomes, and complication rates of LA linear ablation between the PFO and TS groups. Accessing the LA via a PFO is not an unfavorable approach toward LA linear ablation.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Forame Oval Patente/cirurgia , Idoso , Fibrilação Atrial/fisiopatologia , Feminino , Seguimentos , Forame Oval Patente/fisiopatologia , Átrios do Coração/patologia , Átrios do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade
14.
J Cardiovasc Electrophysiol ; 22(7): 739-45, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21235678

RESUMO

INTRODUCTION: Creating complete linear block with point-by-point ablation is challenging in the left atrium (LA). The purpose of this study was to evaluate the efficacy of LA linear ablation using a hexapolar linear multielectrode mapping/ablation catheter. METHODS AND RESULTS: Seventeen patients (age 57 ± 10, 14 male, 6 paroxysmal AF (PAF)) were studied and underwent linear ablation at the mitral isthmus (MI) and LA roof. Ablation was performed with 90 second, 60 °C applications of duty-cycled bipolar/unipolar radiofrequency in a 1:1 ratio simultaneously at all selected electrode pairs. The result could not be evaluated in 2 patients because AF persisted despite cardioversion. Roof line block was confirmed in 9 of 15 (60%) patients. The mean number of applications and the procedural time with and without block was 5.4 ± 2.4 and 4.5 ± 2.2 applications, and 15 ± 8 and 13 ± 7 minutes. MI block was confirmed in 4 of 15 (27%) patients. The mean number of RF applications with and without block was 5.3 ± 2.2 and 9.9 ± 4.4 applications, and the procedural time was 20 ± 9 and 27 ± 10 minutes, respectively. For patients with underlying persistent AF, power was lower than those with PAF but improved when ablation was performed in sinus rhythm. Char was observed in 2 cases; however, no procedure-related complications were observed. CONCLUSIONS: In our initial experience, a linear multielectrode catheter using duty-cycled bipolar and unipolar RF energy was inferior to conventional single point irrigated ablation in achieving LA linear block. However, successful linear block was obtained within a short period of time, when it was achieved.


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/terapia , Função do Átrio Esquerdo/fisiologia , Ablação por Cateter/instrumentação , Ablação por Cateter/métodos , Idoso , Eletrodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
15.
Europace ; 12(10): 1502-4, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20525724

RESUMO

Recently, a novel linear multielectrode mapping/ablation catheter was developed. We present a case in which mitral isthmus line ablation was undertaken with this catheter and showed repeated conduction recovery at the same site on the line. Mapping with this multielectrode catheter along the whole lesion allowed recording of abrupt conduction resumption.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/instrumentação , Idoso , Flutter Atrial/cirurgia , Bloqueio Atrioventricular/cirurgia , Estimulação Cardíaca Artificial , Átrios do Coração/fisiopatologia , Átrios do Coração/cirurgia , Humanos , Masculino , Resultado do Tratamento
17.
Ann Noninvasive Electrocardiol ; 14(1): 96-8, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19149800

RESUMO

A 19-year-old girl was referred to our cardiology department for catheter ablation (isolation of the pulmonary veins) of paroxysmal atrial fibrillation (AF). The diagnosis was made upon a 12-lead ECG of the arrhythmia documented in the emergency room. The ECG showed an irregular tachycardia without wide QRS complexes. Careful assessment revealed the irregularity of the rhythm was a sweep artifact due to a mechanic failure of the ECG-machine to advance the article smoothly. During EP study a concealed anteroseptal accessory pathway causing an orthodromic AV reentrant tachycardia was eliminated by radio-frequency ablation. This example emphasizes the need for careful assessment of an ECG tracing, including printed legends and technical data.


Assuntos
Fibrilação Atrial/diagnóstico , Eletrocardiografia , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Artefatos , Fibrilação Atrial/cirurgia , Ablação por Cateter , Diagnóstico Diferencial , Feminino , Humanos , Sensibilidade e Especificidade , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Adulto Jovem
19.
JACC Clin Electrophysiol ; 4(7): 920-932, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-30025693

RESUMO

OBJECTIVES: This study hypothesized that P-wave morphology and timing under left atrial appendage (LAA) pacing change characteristically immediately upon anterior mitral line (AML) block. BACKGROUND: Perimitral flutter commonly occurs following ablation of atrial fibrillation and can be cured by an AML. However, confirmation of bidirectional block can be challenging, especially in severely fibrotic atria. METHODS: The study analyzed 129 consecutive patients (66 ± 8 years, 64% men) who developed perimitral flutter after atrial fibrillation ablation. We designed electrocardiography criteria in a retrospective cohort (n = 76) and analyzed them in a validation cohort (n = 53). RESULTS: Bidirectional AML block was achieved in 110 (85%) patients. For ablation performed during LAA pacing without flutter (n = 52), we found a characteristic immediate V1 jump (increase in LAA stimulus to P-wave peak interval in lead V1) as a real-time marker of AML block (V1 jump ≥30 ms: sensitivity 95%, specificity 100%, positive predictive value 100%, negative predictive value 88%). As V1 jump is not applicable when block coincides with termination of flutter, absolute V1 delay was used as a criterion applicable in all cases (n = 129) with a delay of 203 ms indicating successful block (sensitivity 92%, specificity 84%, positive predictive value 90%, negative predictive value 87%). Furthermore, an initial negative P-wave portion in the inferior leads was observed, which was attenuated in case of additional cavotricuspid isthmus ablation. Computational P-wave simulations provide mechanistic confirmation of these findings for diverse ablation scenarios (pulmonary vein isolation ± AML ± roof line ± cavotricuspid isthmus ablation). CONCLUSIONS: V1 jump and V1 delay are novel real-time electrocardiography criteria allowing fast and straightforward assessment of AML block during ablation for perimitral flutter.


Assuntos
Ablação por Cateter/métodos , Eletrocardiografia/métodos , Sistema de Condução Cardíaco , Valva Mitral/fisiopatologia , Idoso , Fibrilação Atrial/cirurgia , Flutter Atrial/cirurgia , Feminino , Sistema de Condução Cardíaco/diagnóstico por imagem , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA