Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 96(2): 500-503, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31977150

RESUMO

Aortic insufficiency (AI) is a frequent problem after continuous-flow left ventricular assist device (LVAD) implantation and results in increased morbidity and mortality. Advances in transcatheter aortic valve replacement (TAVR) technology have resulted in this being discussed as a potential option for LVAD patients with AI. While small case series have been published, we report the first case of TAVR thrombosis in an LVAD patient. This case highlights a major diagnostic and management dilemma that should become more present if this strategy becomes more widespread.


Assuntos
Anticoagulantes/administração & dosagem , Insuficiência da Valva Aórtica/cirurgia , Insuficiência Cardíaca/terapia , Coração Auxiliar , Choque Cardiogênico/terapia , Trombose/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Função Ventricular Esquerda , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Esquema de Medicação , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Próteses Valvulares Cardíacas , Humanos , Pessoa de Meia-Idade , Assistência Perioperatória , Fatores de Risco , Choque Cardiogênico/diagnóstico , Choque Cardiogênico/fisiopatologia , Trombose/diagnóstico por imagem , Trombose/tratamento farmacológico , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento
3.
Catheter Cardiovasc Interv ; 87(6): 1164-72, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27145743

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is an established therapy in high-risk patients with severe aortic stenosis. Among patients with reduced left ventricular ejection fraction (LVEF), it is unclear which patients will derive maximal benefit from TAVR. METHODS: Clinical and echocardiographic data of patients with severe aortic stenosis and low LVEF (≤50%) who underwent TAVR at a single institution during 2009-2013 were retrospectively analyzed. Patients were divided into 2 groups post-TAVR based on improved LV function (Group A = ΔLVEF ≥ 10%) versus persistent LV dysfunction (Group B = ΔLVEF<10%). Echocardiographic parameters were assessed for their association with LVEF change post-TAVR. Kaplan-Meier analysis was performed to generate survival estimates. RESULTS: Of 382 patients who underwent TAVR, 60 patients had low LVEF, LV function failed to improve ≥10% in 50% of patients following the procedure (Group B). At baseline echocardiograms, Group B had higher LVEF, stroke volume (SV), SV index; and lower E, E/E', and estimated pulmonary arterial systolic pressure (PASP) compared to Group A. Higher mortality was found in Group B compared to the Group A (p = 0.003) with a significantly shorter survival (Group A = 3.3 ± 0.1 years vs Group B = 2.7 ± 0.2 years, p = 0.003). One-year event free survival was 53.3% in Group B compared to 93.3% in Group A, with a stable trend over ensuing years (5-year survival; 53.3% versus 90.0%, p = 0.003). CONCLUSIONS: In patients undergoing TAVR with depressed LV function, those who failed to improve were more likely to have relatively higher LVEF, SV, and SVI; and lower E, E/E', and PASP at baseline. Mortality rates were found to be higher in persistent LV dysfunction group. © 2015 Wiley Periodicals, Inc.


Assuntos
Estenose da Valva Aórtica/diagnóstico , Valva Aórtica/diagnóstico por imagem , Ecocardiografia/métodos , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/métodos , Função Ventricular Esquerda/fisiologia , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Sístole
4.
Catheter Cardiovasc Interv ; 86(5): 888-94, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25963625

RESUMO

OBJECTIVE: Transcatheter aortic valve replacement (TAVR) has emerged as an alternative to high-risk surgery in patients with comorbid conditions. The role of TAVR in patients with liver disease has not been examined. METHODS: We examined the procedural and intermediate to long-term follow-up outcomes of patients with severe symptomatic aortic valve stenosis and chronic liver disease, identified by liver biopsy or from a combination of clinical findings. All patients were treated with balloon-expandable transfemoral (TF) or transapical (TA) TAVR between November 2007 and February 2014. RESULTS: A total of 17 of 706 (2.41%) patients treated at our institution with TF [n=14] or TA [n=3] TAVR had chronic liver disease (mean age 77.65±9.06 years, 7 women, mean STS score 8.37, mean Charlson score 5.00, mean MELD score 11.35, Child-Turcotte-Pugh (CTP) Class A [n=11], B [n=6], C [n=0], biopsy proven liver disease [n=5]). Median follow-up was 466 days (range=12-1,403 days). The mean post-procedure length of hospital stay was 5.88±3.08 days. Procedural success was achieved in all cases. In-hospital mortality was 5.88% and 90-day mortality was 17.65%. Safety and efficacy endpoints as defined by the valve academic research consortium (VARC) were significant for one perioperative death from a proximate cardiac cause (post-operative day 14), one death after hospital discharge of unknown cause (post-operative day 12), two late deaths from non-cardiac causes (post-operative days 50 and 487, respectively), and one late death of unknown cause (post-operative day 1,005). There were no life-threatening or major bleeding complications. One patient had an MI, one had a transient ischemic attack, four had transient, Stage I, acute kidney injury and one had transient, Stage II, acute kidney injury. CONCLUSION: TF and TA TAVR are feasible methods for treating aortic stenosis in patients with chronic liver disease. In patients with mild to moderate chronic liver disease there are acceptable rates of early and late complications, however, outcomes in patients with advanced liver disease (MELD>20 or CTP class C) warrant further study.


Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Hepatopatias/complicações , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Bioprótese , Biópsia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Doença Crônica , Estudos de Viabilidade , Feminino , Artéria Femoral , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Mortalidade Hospitalar , Humanos , Hepatopatias/diagnóstico , Hepatopatias/mortalidade , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
5.
J Cardiothorac Vasc Anesth ; 29(1): 240-5, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25620147

RESUMO

The functional aortic annulus represents a sound clinical framework for understanding the components of the aortic root complex. Recent three-dimensional imaging analysis has demonstrated that the aortic annulus frequently is elliptical rather than circular. Comprehensive three-dimensional quantification of this aortic annular geometry by transesophageal echocardiography and/or multidetector computed tomography is essential to guide precise prosthesis sizing in transcatheter aortic valve replacement to minimize paravalvular leak for optimal clinical outcome. Furthermore, three-dimensional transesophageal echocardiography accurately can quantify additional parameters of the functional aortic annulus such as coronary height for complete sizing profiles for all valve types in transcatheter aortic valve replacement. Although it is maturing rapidly as a clinical imaging modality, its role in transcatheter aortic valve replacement is seen best as complementary to multidetector computed tomography in a multidisciplinary heart team model.


Assuntos
Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Ecocardiografia Tridimensional/métodos , Implante de Prótese de Valva Cardíaca/métodos , Assistência Perioperatória/métodos , Substituição da Valva Aórtica Transcateter/métodos , Ecocardiografia Transesofagiana/métodos , Humanos
6.
J Clin Med ; 12(6)2023 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-36983430

RESUMO

PURPOSE: We report on the clinical course and management of patients supported with durable implantable LVADs who developed outflow graft obstructions at a large academic center. METHODS: We performed a retrospective review of patients receiving LVAD support from 2012 through 2020. Patients who developed an outflow graft obstruction diagnosed by computed tomography angiography (CTA) or angiogram were identified, and patient characteristics and outcomes were reported. RESULTS: Of the 324 patients supported by LVAD at our institution, 11 patients (3.4%) were diagnosed with outflow graft obstructions. The most common presentation was low flow alarms, which was present in 10/11 patients, and the remaining patient presented with lightheadedness. Patients had minimal LDH elevation with 8/11 presenting with less than 2-fold the upper limit of normal. Transthoracic echocardiograms were not diagnostic, but CTA enabled non-invasive diagnoses in 8/11 of the patients. Three patients with extrinsic compression of the outflow graft successfully underwent endovascular stent placement, and three patients with outflow cannula kinks received supportive care. Of the five patients diagnosed with intraluminal thromboses, one received a heart transplant, one underwent an outflow graft revision, and three received supportive care due to comorbidities. CONCLUSION: Outflow graft obstructions remain a rare, but serious complication. The true prevalence of this entity is likely underestimated due to the non-specific clinical presentation. CTA is a pivotal non-invasive diagnostic step. Patients with external compression were successfully treated with endovascular stenting.

7.
Platelets ; 23(6): 463-6, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22686448

RESUMO

Essential thrombocythemia (ET) is a myeloproliferative disorder characterized by hemorrhagic and thrombotic complications. We describe a rare case of ST-segment elevation myocardial infarction (STEMI) in a patient with previously undiagnosed ET, confirmed by gene mutation. A 68-year-old man presented with severe acute chest pain and was diagnosed with STEMI. Primary coronary angiography showed severe stenosis with thrombus in the proximal left anterior descending coronary artery. Percutaneous aspiration thrombectomy was performed with no residual stenosis. The patient was discharged on antiplatelet agents, aspirin, and clopidogrel. Further investigations for intracoronary thrombus with no underlying atherosclerotic disease revealed positive Janus kinase 2 (JAK2) V617F gene mutation, and this was consistent with a diagnosis of ET with elevated platelet count. This case describes a rare initial presentation of previously undiagnosed ET with acute STEMI and highlights the potential importance of secondary workup for non-atherosclerotic causes of STEMI with isolated intracoronary thrombus otherwise normal coronary vasculature with no focal atherosclerosis.


Assuntos
Trombose Coronária/diagnóstico , Janus Quinase 2/genética , Infarto do Miocárdio/diagnóstico , Trombectomia , Trombocitemia Essencial/diagnóstico , Idoso , Angioplastia Coronária com Balão , Plaquetas/patologia , Angiografia Coronária , Trombose Coronária/complicações , Trombose Coronária/genética , Trombose Coronária/cirurgia , Vasos Coronários , Eletrocardiografia , Humanos , Masculino , Mutação , Infarto do Miocárdio/complicações , Infarto do Miocárdio/genética , Infarto do Miocárdio/cirurgia , Contagem de Plaquetas , Trombocitemia Essencial/complicações , Trombocitemia Essencial/genética , Trombocitemia Essencial/cirurgia
8.
POCUS J ; 6(1): 29-32, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-36895500

RESUMO

Background: Focused cardiac ultrasound (FCU) is a safe and efficient diagnostic intervention for internal medicine physicians. FCU is a highly teachable skill, but is used in routine cardiac assessment in only 20% of surveyed training programs.We developed an FCU curriculum for internal medicine residents and an assessment tool to evaluate the impact of the curriculum on trainee knowledge and confidence. Methods: Internal medicine residents rotating through clinical cardiology services underwent 30 minutes of didactic and 60 minutes of hands-on teaching on acquisition and interpretation of FCU. A 20 item pre and post-curriculum online survey was administered (November 2018-December 2019) to assess confidence and knowledge in FCU. Results: 79 of 116 (68%) residents completed the pre-survey and 50 completed the post-survey, of whom 34 received the curriculum. The mean change in confidence score in those who received versus did not receive the curriculum was 0.99 versus 0.39 (p=0.046) on a 5-point Likert scale. Among 33 residents who had paired pre- and post-surveys the mean change in confidence score was 1.2 versus 0.85 (p<0.001) in those who received versus did not receive the curriculum. The mean increase in knowledge score was 13% versus 7% respectively (p<0.0001). Conclusions: We instituted a novel curriculum for internal medicine residents to gain experience in image acquisition and interpretation. Both confidence and knowledge in FCU improved following the curriculum, indicating that this is a highly teachable skill. Additional analysis of the of the FCU study images will be useful for informing future interventions.

9.
J Card Surg ; 25(1): 62-4, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-19811575

RESUMO

Kommerell's diverticulum of an aberrant left subclavian artery associated with a right-sided aortic arch is a rare congenital aortic anomaly. This communication reports two cases of this congenital anomaly leading to severe dysphagia. Both cases were successfully repaired with a staged open approach rather than an endovascular approach, which would not have addressed the presenting symptom of dysphagia.


Assuntos
Aorta Torácica/cirurgia , Síndromes do Arco Aórtico/cirurgia , Transtornos de Deglutição/cirurgia , Divertículo/cirurgia , Artéria Subclávia/anormalidades , Doenças Vasculares/cirurgia , Aorta Torácica/patologia , Síndromes do Arco Aórtico/patologia , Transtornos de Deglutição/etiologia , Transtornos de Deglutição/patologia , Divertículo/complicações , Divertículo/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Subclávia/patologia , Artéria Subclávia/cirurgia , Doenças Vasculares/complicações , Doenças Vasculares/patologia
10.
Heart ; 106(15): 1132-1141, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32354800

RESUMO

Since its recognition in December 2019, covid-19 has rapidly spread globally causing a pandemic. Pre-existing comorbidities such as hypertension, diabetes, and cardiovascular disease are associated with a greater severity and higher fatality rate of covid-19. Furthermore, COVID-19 contributes to cardiovascular complications, including acute myocardial injury as a result of acute coronary syndrome, myocarditis, stress-cardiomyopathy, arrhythmias, cardiogenic shock, and cardiac arrest. The cardiovascular interactions of COVID-19 have similarities to that of severe acute respiratory syndrome, Middle East respiratory syndrome and influenza. Specific cardiovascular considerations are also necessary in supportive treatment with anticoagulation, the continued use of renin-angiotensin-aldosterone system inhibitors, arrhythmia monitoring, immunosuppression or modulation, and mechanical circulatory support.


Assuntos
Doenças Cardiovasculares/epidemiologia , Infecções por Coronavirus/epidemiologia , Pneumonia Viral/epidemiologia , Antagonistas de Receptores de Angiotensina/uso terapêutico , Enzima de Conversão de Angiotensina 2 , Inibidores da Enzima Conversora de Angiotensina/uso terapêutico , Anticoagulantes/uso terapêutico , Azitromicina/uso terapêutico , Betacoronavirus , Biomarcadores/sangue , COVID-19 , Doenças Cardiovasculares/terapia , Cloroquina/uso terapêutico , Comorbidade , Infecções por Coronavirus/mortalidade , Síndrome da Liberação de Citocina/epidemiologia , Coagulação Intravascular Disseminada/epidemiologia , Oxigenação por Membrana Extracorpórea , Humanos , Hidroxicloroquina/uso terapêutico , Imunossupressores/uso terapêutico , Influenza Humana/mortalidade , Pulmão/metabolismo , Pulmão/patologia , Miocárdio/metabolismo , Miocárdio/patologia , Pandemias , Peptidil Dipeptidase A/metabolismo , SARS-CoV-2 , Síndrome Respiratória Aguda Grave/mortalidade , Troponina/sangue , Tromboembolia Venosa/epidemiologia , Tromboembolia Venosa/prevenção & controle
12.
J Am Soc Echocardiogr ; 31(3): 289-296, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29111122

RESUMO

BACKGROUND: Contrast-enhanced echocardiography (CE) helps to improve image quality in patients with suboptimal acoustic windows. Despite current recommendations, contrast use remains low. The aim of this study was to identify populations that would benefit more from contrast use. METHODS: A total of 176 subjects (137 men; mean age, 60.8 ± 13.7 years) with technically difficult transthoracic echocardiographic studies who received clinically indicated intravenous contrast were prospectively studied. The impact on clinical decision making (including alterations in medical therapy, referral, imaging, or clinical procedures) was evaluated. RESULTS: The use of CE enabled biplane left ventricular (LV) ejection fraction measurement in 97.2% of studies and the interpretation of regional wall motion in 95% of studies. CE allowed definitive assessment of the presence or absence of LV thrombus in 99% of the cases. In the 174 patients whose ordering physicians could be reached at the time of image interpretation, changes in management occurred in 51% of subjects. There was no difference in the proportion of management changes between inpatients and outpatients (60.0% vs 48.1%, P = .225). Subjects with heart failure, cardiomyopathy, and arrhythmia had a higher proportion of changes (61.4% vs 44.2% [P = .031], 62.5% vs 45.0% [P = .028], and 72.0% vs 47.7% [P = .030], respectively). The proportion of management change after CE increased as pre-CE estimated ejection fraction decreased. Logistic regression showed that pre-CE estimated LV ejection fraction < 50% was the only significant predictor of change of management after contrast (P = .004). CONCLUSIONS: The use of CE has a significant impact on clinical decision making in patients with suboptimal acoustic windows, especially in those with depressed pre-CE LV ejection fractions.


Assuntos
Tomada de Decisão Clínica/métodos , Meios de Contraste/farmacologia , Ecocardiografia Doppler/métodos , Insuficiência Cardíaca/diagnóstico , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia , Feminino , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes
14.
JACC Cardiovasc Interv ; 11(14): 1377-1387, 2018 07 23.
Artigo em Inglês | MEDLINE | ID: mdl-29960755

RESUMO

OBJECTIVES: The aim of this study was to determine factors affecting paravalvular leak (PVL) in transcatheter aortic valve replacement (TAVR) with the Edwards SAPIEN 3 (S3) valve in extremely large annuli. BACKGROUND: The largest recommended annular area for the 29-mm S3 is 683 mm2. However, experience with S3 TAVR in annuli >683 mm2 has not been widely reported. METHODS: From December 2013 to July 2017, 74 patients across 16 centers with mean area 721 ± 38 mm2 (range: 684 to 852 mm2) underwent S3 TAVR. The transfemoral approach was used in 95%, and 39% were under conscious sedation. Patient, anatomic, and procedural characteristics were retrospectively analyzed. Valve Academic Research Consortium-2 outcomes were reported. RESULTS: Procedural success was 100%, with 2 deaths, 1 stroke, and 2 major vascular complications at 30 days. Post-dilatation occurred in 32%, with final balloon overfilling (1 to 5 ml extra) in 70% of patients. Implantation depth averaged 22.3 ± 12.4% at the noncoronary cusp and 20.7 ± 9.9% at the left coronary cusp. New left bundle branch block occurred in 17%, and 6.3% required new permanent pacemakers. Thirty-day echocardiography showed mild PVL in 22.3%, 6.9% moderate, and none severe. There was no annular rupture or coronary obstruction. Mild or greater PVL was associated with larger maximum annular and left ventricular outflow tract (LVOT) diameters, larger LVOT area and perimeter, LVOT area greater than annular area, and higher annular eccentricity. CONCLUSIONS: TAVR with the 29-mm S3 valve beyond the recommended range by overexpansion is safe, with acceptable PVL and pacemaker rates. Larger LVOTs and more eccentric annuli were associated with more PVL. Longer term follow-up will be needed to determine durability of S3 TAVR in this population.


Assuntos
Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Feminino , Humanos , Masculino , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
15.
J Clin Endocrinol Metab ; 92(12): 4609-14, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17848406

RESUMO

CONTEXT: Polycystic ovary syndrome (PCOS) is associated with comorbidities that may contribute to increased risk of cardiovascular disease. PCOS is associated with increased risk of metabolic syndrome, dyslipidemia, and diabetes, but it remains unclear whether traditional cardiovascular (CV) risk factors can help predict coronary artery disease in this population. OBJECTIVE: The objectives of the study were to detect early-onset subclinical coronary atherosclerosis (using coronary artery calcium as a marker) in young women with PCOS, compared with age- and body mass index-matched controls, and to compare traditional CV risk factors and inflammatory markers in the two groups. DESIGN: This was a prospective case-control study. SETTING: The study was conducted at a university hospital. SUBJECTS: Twenty-four obese (body mass index >or= 30 kg/m2) PCOS subjects and 24 obese controls participated. OUTCOME MEASURES: Coronary artery calcium, inflammatory markers (high-sensitivity C-reactive protein, IL-6, TNFalpha, adiponectin, leptin), fasting blood tests (glucose, lipids, insulin), and dual-energy x-ray absorptiometry scan for body fat distribution were measured. RESULTS: Coronary artery calcium was detected in eight of 24 PCOS subjects (33%) and two of 24 controls (8%) (odds ratio 5.5, 95% confidence interval 1.03, 29.45, P < 0.03). Traditional CV risk factors did not differ significantly between the two groups, nor did markers of inflammation or adiposity, body fat distribution, or metabolic parameters with the exception of significantly lower quantitative insulin sensitivity check index (marker for insulin resistance) in the PCOS group (P < 0.05). CONCLUSIONS: Young, obese women with PCOS have a high prevalence of early asymptomatic coronary atherosclerosis, compared with obese controls. This increased risk is independent of traditional CV risk factors and novel markers of inflammation. These findings underscore the need to screen and aggressively counsel and treat these women to prevent symptomatic CV disease.


Assuntos
Doença da Artéria Coronariana/complicações , Obesidade/complicações , Síndrome do Ovário Policístico/complicações , Absorciometria de Fóton , Adiposidade/fisiologia , Adulto , Biomarcadores , Cálcio/análise , Cálcio/metabolismo , Doenças Cardiovasculares/complicações , Doenças Cardiovasculares/patologia , Estudos de Casos e Controles , Doença Crônica , Doença da Artéria Coronariana/patologia , Vasos Coronários/metabolismo , Feminino , Humanos , Mediadores da Inflamação/sangue , Resistência à Insulina/fisiologia , Pessoa de Meia-Idade , Obesidade/patologia , Síndrome do Ovário Policístico/patologia , Estudos Prospectivos , Fatores de Risco , Tomografia Computadorizada por Raios X
17.
J Invasive Cardiol ; 29(7): 239-245, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28570260

RESUMO

BACKGROUND: Accurate measurement of aortic annulus is crucial before transcatheter aortic valve replacement (TAVR). Computed tomography (CT) angiography is the most commonly utilized method, but requires contrast administration. Cardiovascular magnetic resonance (CMR) imaging is a promising alternative modality to provide aortic annulus measurements. Few studies have compared the clinical feasibility and accuracy of non-contrast CMR to contrast-enhanced computed tomography (CT) angiography in order to provide a non-contrast alternative to CT annular sizing. METHODS: Twenty-one consecutive patients (mean age, 85.7 ± 5.2 years) with severe aortic stenosis (mean aortic valve area, 0.6 ± 0.1 cm²) underwent pre-TAVR CT angiography and a non-contrast CMR at 1.5 T. CT measurements were performed during systole as the clinical non-invasive standard. CMR measurements were performed during systole and diastole and included three-dimensional (3D) and two-dimensional (2D) methods. Interobserver differences were assessed using intraclass correlation. We recorded scan time in each patient. RESULTS: The mean systolic annular area was not significantly different between CT and 3D-CMR (480.0 ± 77.9 mm² vs 479.4 ± 66.2 mm²; P=.98) in systole. There was no clinically relevant systematic difference between area measurements [mean difference, 0.6 mm²; limits of agreement -38.2 mm²; 39.3 mm²] using Bland-Altman analyses. Interobserver correlation was excellent. The diagnostic systolic 3D-CMR annular sizing scan was achieved in 4.4 ± 2.7 min. CONCLUSION: Non-contrast CMR protocol for the measurement of aortic annulus area is feasible and accurate. 3D-CMR could provide an alternative for annular sizing pre-TAVR assessment in patients who cannot undergo contrast-enhanced CT studies.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Cateterismo Cardíaco/métodos , Angiografia por Tomografia Computadorizada/métodos , Imagem Cinética por Ressonância Magnética/métodos , Tomografia Computadorizada Multidetectores/métodos , Substituição da Valva Aórtica Transcateter/métodos , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Meios de Contraste , Ecocardiografia Transesofagiana/métodos , Feminino , Seguimentos , Humanos , Masculino , Cuidados Pré-Operatórios/métodos , Estudos Prospectivos , Curva ROC
18.
Int J Cardiovasc Imaging ; 32(1): 173-9, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26319217

RESUMO

There is an established sex difference in cardiovascular disease among pre-menopausal women and age-matched men, with men having greater susceptibility to cardiovascular and coronary artery disease. Cardiovascular calcification may be linked to the atherosclerotic process and resulting disease, but the sex difference regarding coronary artery disease susceptibility and calcification is incompletely understood. We thought to measure calcium volume in different chest vascular beds in very elderly men and women with severe aortic stenosis (AS). Computed tomography scans of 94 patients with severe AS were calcium volume scored on Aquarius iNtuition Terarecon (Terarecon Inc., CA, USA) work stations. Coronary beds, aortic valve, mitral valve apparatus, and the thoracic aorta were examined. A significant sex difference in the mean total calcium volume of the coronary arteries was found in elderly (p = 0.001), with men having greater levels of calcification. There is also a significant sex difference in the amount of aortic valve calcium (p = 0.003). Furthermore, aortic and coronary calcification was independently correlated with sex. This study demonstrates a significant sex impact on calcification in the coronary beds and aortic valve in elderly patients with severe AS.


Assuntos
Estenose da Valva Aórtica/complicações , Valva Aórtica/patologia , Calcinose/complicações , Doença da Artéria Coronariana/complicações , Calcificação Vascular/complicações , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Aorta Torácica/diagnóstico por imagem , Doenças da Aorta/complicações , Doenças da Aorta/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico por imagem , Aortografia/métodos , Calcinose/diagnóstico por imagem , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Feminino , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Fatores Sexuais , Tomografia Computadorizada por Raios X , Calcificação Vascular/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA