Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Am J Ophthalmol ; 136(1): 171-2, 2003 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12834685

RESUMO

PURPOSE: To determine the immediate effect on corneal thickness of cataract extraction using phacoemulsification. DESIGN: Prospective consecutive nonrandomized humans undergoing standard small-incision phacoemulsification and intraocular lens insertion. METHODS: Corneal thickness was measured immediately preoperative and postoperatively in 58 consecutive patients undergoing phacoemulsification in the absence of other ocular abnormalities. Corneal thickness was determined centrally and in the midperiphery of four quadrants. The last 17 eyes were also evaluated for the effect of pressure from a Honan balloon on corneal thickness. SETTING: Faculty practice in medical school and university hospital. The cornea thinned in all five of the measured locations, with statistical significance being reached only in the four midperipheral quadrants. Pressure from the Honan balloon resulted in a negligible increase in corneal thickness preoperatively. CONCLUSIONS: Corneas were found to have thinned statistically significantly immediately after phacoemulsification; however, the degree of thinning has doubtful clinical significance and does not represent a significant dehydration of the cornea during the surgical procedure.


Assuntos
Córnea/patologia , Facoemulsificação , Complicações Pós-Operatórias/patologia , Humanos , Implante de Lente Intraocular , Lentes Intraoculares , Estudos Prospectivos
2.
Eye Contact Lens ; 31(6): 257-62, 2005 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16284504

RESUMO

PURPOSE: Computerized videokeratography (CVK) has become the standard method for measuring the corneal curvature after refractive surgery. However, few resources exist on the use of CVK data for postoperative contact lens fitting, and no recommendations exist on the selection of the best topographic algorithm relevant to gas-permeable (GP) lens fitting. This study assessed the optimal use of topographic data to fit spherical GP contact lenses on patients who have undergone laser in situ keratomileusis. METHODS: A retrospective analysis of CVK maps from eight post-LASIK eyes fitted with spherical GP lenses was performed in the Contact Lens Service of the Department of Ophthalmology at Case Western Reserve University and University Hospitals of Cleveland. Axial and tangential maps from the Dicon CT 200 (version 3.50) or Humphrey Atlas (version A8) topographer were analyzed. Averaged dioptric curvatures from different locations (inferior, superior, and temporal) at various distances (2.0 mm, 2.5 mm, 3.0 mm, 3.5 mm, and 4.0 mm) from the vertex normal of each eye were compared with the base curves of the prescribed GP contact lenses. RESULTS: One-way analysis of variance, Pearson correlation analysis, and paired t tests showed that the best topographic predictors of a successful GP base curve were the average curvatures at the 4.0 mm distance on the axial maps (r=0.8078, P=0.05) and at the 2.0 mm distance on the tangential maps (r=0.9738, P=0.0002). The mean dioptric powers of the GP base curve, axial map 4.0 mm curvature, and tangential map 2.0 mm curvature were 41.50 diopters (D), 42.65 D, and 42.67 D, respectively. CONCLUSION: To simplify and guide GP fitting after LASIK, the average dioptric curvature 4.0 mm from the vertex normal on axial maps or 2.0 mm from the vertex normal on tangential maps are the best predictors of accurate GP base curve selection.


Assuntos
Algoritmos , Lentes de Contato de Uso Prolongado , Córnea/anatomia & histologia , Topografia da Córnea/métodos , Ceratomileuse Assistida por Excimer Laser In Situ , Seguimentos , Humanos , Período Pós-Operatório , Ajuste de Prótese/métodos , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA