Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Synchrotron Radiat ; 26(Pt 5): 1751-1762, 2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-31490167

RESUMO

X-ray ptychography is a coherent diffraction imaging technique with a high resolving power and excellent quantitative capabilities. Although very popular in synchrotron facilities nowadays, its implementation with X-ray energies above 15 keV is very rare due to the challenges imposed by the high energies. Here, the implementation of high-energy X-ray ptychography at 17 and 33.6 keV is demonstrated and solutions to overcome the important challenges are provided. Among the particular aspects addressed are the use of an efficient high-energy detector, a long synchrotron beamline for the high degree of spatial coherence, a beam with 1% monochromaticity providing high flux, and efficient multilayer coated Kirkpatrick-Baez X-ray optics to shape the beam. The constraints imposed by the large energy bandwidth are carefully analyzed, as well as the requirements to sample correctly the high-energy diffraction patterns with small speckle size. In this context, optimized scanning trajectories allow the total acquisition time to be reduced by up to 35%. The paper explores these innovative solutions at the ID16A nano-imaging beamline by ptychographic imaging of a 200 nm-thick gold lithography sample.


Assuntos
Óptica e Fotônica/instrumentação , Intensificação de Imagem Radiográfica/instrumentação , Síncrotrons , Desenho de Equipamento , Ouro/química , Modelos Teóricos , Difração de Raios X , Raios X
2.
J Synchrotron Radiat ; 24(Pt 6): 1226-1236, 2017 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-29091066

RESUMO

The detection system is a key part of any imaging station. Here the performance of the novel sCMOS-based detection system installed at the ID17 biomedical beamline of the European Synchrotron Radiation Facility and dedicated to high-resolution computed-tomography imaging is analysed. The system consists of an X-ray-visible-light converter, a visible-light optics and a PCO.Edge5.5 sCMOS detector. Measurements of the optical characteristics, the linearity of the system, the detection lag, the modulation transfer function, the normalized power spectrum, the detective quantum efficiency and the photon transfer curve are presented and discussed. The study was carried out at two different X-ray energies (35 and 50 keV) using both 2× and 1× optical magnification systems. The final pixel size resulted in 3.1 and 6.2 µm, respectively. The measured characteristic parameters of the PCO.Edge5.5 are in good agreement with the manufacturer specifications. Fast imaging can be achieved using this detection system, but at the price of unavoidable losses in terms of image quality. The way in which the X-ray beam inhomogeneity limited some of the performances of the system is also discussed.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA