Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Exp Physiol ; 2024 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-39102430

RESUMO

To examine the feasibility, utility and safety of superimposed lower body negative pressure (LBNP) and tilt during supine cycling in individuals suffering from persisting post-concussive symptoms (PPCS). Eleven individuals aged 17-31 (6 females/5 males) participated in two randomized separate visits, 1 week apart. A ramp-incremental test was performed during both visits until volitional failure. Visits included no pressure (control) or LBNP at -40 Torr (experimental) with head-up tilt at 15 degrees (females) or 30 degrees (males). Transcranial Doppler ultrasound was utilized to quantify middle cerebral artery velocity (MCAv), while symptom reports were filled out before and 0, 10, and 60 min post-exertion. Ratings of exertion and overall condition followed similar trends for participants across both tests. The relative increase in MCAv was blunted during the experimental condition (8%) compared to control (24%), while a greater heart rate (17 beats/min) was achieved during the LBNP condition (P = 0.047). Symptom severity at the 0 and 10 min post-exertion time points displayed negligible-to-small effect sizes between conditions (Wilcoxon's r < 0.11). Symptom reporting was lower at the 60 min post-exertion time point with these displaying a moderate effect size (Wilcoxon's r = 0.31). The combination of LBNP and tilt during supine cycling did not change the participants' subjective interpretation of the exertional test but attenuated the hyperpnia-induced vasodilatory MCAv response, while also enabling participants to achieve a higher heart rate during exercise and reduced symptoms 1 h later. As this protocol is safe and feasible, further research is warranted in this area for developing PPCS treatment options. HIGHLIGHTS: What is the central question of this study? What are the feasibility, safety and utility of combining head-up tilt with lower body negative pressure during supine cycling for blunting the increase in cerebral blood velocity seen during moderate-intensity exercise in individuals experiencing persisting post-concussion symptoms? What is the main finding and its importance? Although no differences were found in symptoms between conditions within the first 10 min following exertion, symptom severity scores showed a clinically meaningful reduction 60 min following the experimental condition compared to the non-experimental control condition.

2.
Exp Physiol ; 2024 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-39382938

RESUMO

There are differences within the literature regarding the upper frequency cut-off point of the dynamic cerebral autoregulation (CA) high-pass filter. The projection pursuit regression approach has demonstrated that the upper frequency limit is ∼0.07 Hz, whereas another approach [transfer function analysis (TFA) phase approaching zero] indicated a theoretical upper frequency limit for the high-pass filter of 0.24 Hz. We investigated how these limits accurately represent the CA upper frequency limit, in addition to extending earlier findings with respect to biological sexes and across the cardiac cycle. Sixteen participants (nine females and seven males) performed repeated squat-stand manoeuvres at frequencies of 0.05, 0.10, 0.15, 0.20 and 0.25 Hz, with insonation of the middle and posterior cerebral arteries. Linear regression modelling with adjustment for sex and order of squat completion was used to compared TFA gain and phase with 0.25 Hz (above the theoretical limit of CA). The upper frequency limit of CA with TFA gain was within the range of 0.05-0.10 Hz, whereas TFA phase was within the range of 0.20-0.25 Hz, and consistent between vessels, between sexes and across the cardiac cycle. Females displayed greater middle cerebral artery gain compared with males (all P < 0.047), and no phase differences were present (all P > 0.072). Although sex-specific differences were present for specific TFA metrics at a given frequency, the upper frequency limit of autoregulation was similar between cerebral conduit vessels, cardiac cycle phase and biological sex. Future work is warranted to determine whether an upper frequency limit exists with respect to hysteresis analyses.

3.
Sensors (Basel) ; 24(8)2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38676247

RESUMO

Frequency-domain near-infrared spectroscopy (FD-NIRS) has been used for non-invasive assessment of cortical oxygenation since the late 1990s. However, there is limited research demonstrating clinical validity and general reproducibility. To address this limitation, recording duration for adequate validity and within- and between-day reproducibility of prefrontal cortical oxygenation was evaluated. To assess validity, a reverse analysis of 10-min-long measurements (n = 52) at different recording durations (1-10-min) was quantified via coefficients of variation and Bland-Altman plots. To assess within- and between-day within-subject reproducibility, participants (n = 15) completed 2-min measurements twice a day (morning/afternoon) for five consecutive days. While 1-min recordings demonstrated sufficient validity for the assessment of oxygen saturation (StO2) and total hemoglobin concentration (THb), recordings ≥4 min revealed greater clinical utility for oxy- (HbO) and deoxyhemoglobin (HHb) concentration. Females had lower StO2, THb, HbO, and HHb values than males, but variability was approximately equal between sexes. Intraclass correlation coefficients ranged from 0.50-0.96. The minimal detectable change for StO2 was 1.15% (95% CI: 0.336-1.96%) and 3.12 µM for THb (95% CI: 0.915-5.33 µM) for females and 2.75% (95%CI: 0.807-4.70%) for StO2 and 5.51 µM (95%CI: 1.62-9.42 µM) for THb in males. Overall, FD-NIRS demonstrated good levels of between-day reliability. These findings support the application of FD-NIRS in field-based settings and indicate a recording duration of 1 min allows for valid measures; however, data recordings of ≥4 min are recommended when feasible.


Assuntos
Hemoglobinas , Oxigênio , Córtex Pré-Frontal , Espectroscopia de Luz Próxima ao Infravermelho , Humanos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Masculino , Feminino , Córtex Pré-Frontal/diagnóstico por imagem , Córtex Pré-Frontal/metabolismo , Adulto , Reprodutibilidade dos Testes , Oxigênio/metabolismo , Oxigênio/análise , Hemoglobinas/análise , Hemoglobinas/metabolismo , Saturação de Oxigênio/fisiologia , Adulto Jovem , Oxiemoglobinas/metabolismo , Oxiemoglobinas/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA