Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Small ; 19(36): e2301161, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37127870

RESUMO

Cdx Hg1- x Se/HgS/Cdy Zn1- y S core/multi-shell quantum dots (QDs) exhibiting bright tissue-penetrating shortwave infrared (SWIR; 1000-1700 nm) photoluminescence (PL) are engineered. The new structure consists of a quasi-type-II Cdx Hg1- x Se/HgS core/inner shell domain creating luminescent bandgap tunable across SWIR window and a wide-bandgap Cdy Zn1- y S outer shell boosting the PL quantum yield (QY). This compositional sequence also facilitates uniform and coherent shell growth by minimizing interfacial lattice mismatches, resulting in high QYs in both organic (40-80%) and aqueous (20-70%) solvents with maximum QYs of 87 and 73%, respectively, which are comparable to those of brightest visible-to-near infrared QDs. Moreover, they maintain bright PL in a photocurable resin (QY 40%, peak wavelength ≈ 1300 nm), enabling the fabrication of SWIR-luminescent composites of diverse morphology and concentration. These composites are used to localize controlled amounts of SWIR QDs inside artificial (Intralipid) and porcine tissues and quantitatively evaluate the applicability as luminescent probes for deep-tissue imaging.

2.
Small ; 18(25): e2107888, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35607749

RESUMO

A great deal of research has focused on small-scale robots for biomedical applications and minimally invasive delivery of therapeutics (e.g., cells, drugs, and genes) to a target area. Conventional fabrication methods, such as two-photon polymerization, can be used to build sophisticated micro- and nanorobots, but the long fabrication cycle for a single microrobot has limited its practical use. This study proposes a biodegradable spherical gelatin methacrylate (GelMA) microrobot for mass production in a microfluidic channel. The proposed microrobot is fabricated in a flow-focusing droplet generator by shearing a mixture of GelMA, photoinitiator, and superparamagnetic iron oxide nanoparticles (SPIONs) with a mixture of oil and surfactant. Human nasal turbinate stem cells (hNTSCs) are loaded on the GelMA microrobot, and the hNTSC-loaded microrobot shows precise rolling motion in response to an external rotating magnetic field. The microrobot is enzymatically degraded by collagenase, and released hNTSCs are proliferated and differentiated into neuronal cells. In addition, the feasibility of the GelMA microrobot as a cell therapeutic delivery system is investigated by measuring electrophysiological activity on a multielectrode array. Such a versatile and fully biodegradable microrobot has the potential for targeted stem cell delivery, proliferation, and differentiation for stem cell-based therapy.


Assuntos
Gelatina , Metacrilatos , Sistemas de Liberação de Medicamentos/métodos , Humanos , Campos Magnéticos , Células-Tronco
3.
Adv Mater ; 35(13): e2208747, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36640750

RESUMO

Functional restoration by the re-establishment of cellular or neural connections remains a major challenge in targeted cell therapy and regenerative medicine. Recent advances in magnetically powered microrobots have shown potential for use in controlled and targeted cell therapy. In this study, a magnetic neurospheroid (Mag-Neurobot) that can form both structural and functional connections with an organotypic hippocampal slice (OHS) is assessed using an ex vivo model as a bridge toward in vivo application. The Mag-Neurobot consists of hippocampal neurons and superparamagnetic nanoparticles (SPIONs); it is precisely and skillfully manipulated by an external magnetic field. Furthermore, the results of patch-clamp recordings of hippocampal neurons indicate that neither the neuronal excitabilities nor the synaptic functions of SPION-loaded cells are significantly affected. Analysis of neural activity propagation using high-density multi-electrode arrays shows that the delivered Mag-Neurobot is functionally connected with the OHS. The applications of this study include functional verification for targeted cell delivery through the characterization of novel synaptic connections and the functionalities of transported and transplanted cells. The success of the Mag-Neurobot opens up new avenues of research and application; it offers a test platform for functional neural connections and neural regenerative processes through cell transplantation.


Assuntos
Nanopartículas de Magnetita , Neurônios , Neurônios/fisiologia , Hipocampo/fisiologia , Medicina Regenerativa , Terapia Baseada em Transplante de Células e Tecidos , Campos Magnéticos , Nanopartículas de Magnetita/química
4.
Adv Healthc Mater ; 11(11): e2102529, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35137568

RESUMO

Robotic magnetic manipulation systems offer a wide range of potential benefits in medical fields, such as precise and selective manipulation of magnetically responsive instruments in difficult-to-reach vessels and tissues. However, more preclinical/clinical studies are necessary before robotic magnetic interventional systems can be widely adopted. In this study, a clinically translatable, electromagnetically controllable microrobotic interventional system (ECMIS) that assists a physician in remotely manipulating and controlling microdiameter guidewires in real time, is reported. The ECMIS comprises a microrobotic guidewire capable of active magnetic steering under low-strength magnetic fields, a human-scale electromagnetic actuation (EMA) system, a biplane X-ray imaging system, and a remote guidewire/catheter advancer unit. The proposed ECMIS demonstrates targeted real-time cardiovascular interventions in vascular phantoms through precise and rapid control of the microrobotic guidewire under EMA. Further, the potential clinical effectiveness of the ECMIS for real-time cardiovascular interventions is investigated through preclinical studies in coronary, iliac, and renal arteries of swine models in vivo, where the magnetic steering of the microrobotic guidewire and control of other ECMIS modules are teleoperated by operators in a separate control booth with X-ray shielding. The proposed ECMIS can help medical physicians optimally manipulate interventional devices such as guidewires under minimal radiation exposure.


Assuntos
Campos Magnéticos , Magnetismo , Animais , Desenho de Equipamento , Imagens de Fantasmas , Suínos
5.
Adv Healthc Mater ; 10(19): e2100801, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34160909

RESUMO

Targeted stem cell delivery with microrobots has emerged as a potential alternative therapeutic strategy in regenerative medicine, and intranasal administration is an effective approach for minimally invasive delivery of therapeutic agents into the brain. In this study, a magnetically powered stem cell-based microrobot ("Cellbot") is used for minimally invasive targeted stem cell delivery to the brain through the intranasal passage. The Cellbot is developed by internalizing superparamagnetic iron oxide nanoparticles (SPIONs) into human nasal turbinate stem cells. The SPIONs have no influence on hNTSC characteristics, including morphology, cell viability, and neuronal differentiation. The Cellbots are capable of proliferation and differentiation into neurons, neural precursor cells, and neurogliocytes. The Cellbots in the microfluidic channel can be reliably manipulated by an external magnetic field for orientation and position control. Using an ex vivo model based on brain organoids, it is determined that the Cellbots can be transplanted into brain tissue. Using a murine model, it is demonstrated that the Cellbots can be intranasally administered and magnetically guided to the target tissue in vivo. This approach has the potential to effectively treat central nervous system disorders in a minimally invasive manner.


Assuntos
Nanopartículas de Magnetita , Células-Tronco Neurais , Administração Intranasal , Animais , Encéfalo , Sobrevivência Celular , Campos Magnéticos , Camundongos
6.
Sci Adv ; 6(39)2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32978164

RESUMO

There has been a great deal of interest in the development of technologies for actively manipulating neural networks in vitro, providing natural but simplified environments in a highly reproducible manner in which to study brain function and related diseases. Platforms for these in vitro neural networks require precise and selective neural connections at the target location, with minimal external influences, and measurement of neural activity to determine how neurons communicate. Here, we report a neuron-loaded microrobot for selective connection of neural networks via precise delivery to a gap between two neural clusters by an external magnetic field. In addition, the extracellular action potential was propagated from one cluster to the other through the neurons on the microrobot. The proposed technique shows the potential for use in experiments to understand how neurons communicate in the neural network by actively connecting neural clusters.

7.
Adv Healthc Mater ; 8(21): e1900739, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31596550

RESUMO

A silicon carbonitride (SICN) ceramic microrobot, biocompatible and magnetically activable, is developed for the delivery of viable cells to defective tissue by sequential steps of microstructuring, magnetization, and cell loading. The ceramic carrier of porous cylindrical framework is fabricated by 3D laser lithography using a photocurable preceramic polymer, chemically modified polyvinylsilazane, and subsequent pyrolysis at 600 °C under an inert atmosphere. Magnetic nanoparticles (MNP) are integrated into the surface-modified ceramic carrier by thiol-ene click reaction. Finally, the microrobot is loaded with fibroblast cells, which can be guided by a rotating external magnetic field. The proposed ceramic microrobot is mechanically durable, adequately controllable with external magnetic field, and quite compatible with mammalian cells.


Assuntos
Materiais Biocompatíveis/química , Cerâmica/química , Sistemas de Liberação de Medicamentos , Magnetismo , Polímeros/química , Compostos de Silício/química , Nanopartículas Metálicas/química
8.
Soft Robot ; 6(1): 54-68, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30312145

RESUMO

Magnetically actuated soft robots may improve the treatment of disseminated intravascular coagulation. Significant progress has been made in the development of soft robotic systems that steer catheters. A more challenging task, however, is the development of systems that steer sub-millimeter-diameter guidewires during intravascular treatments; a novel microrobotic approach is required for steering. In this article, we develop a novel, magnetically actuated, soft microrobotic system, increasing the steerability of a conventional guidewire. The soft microrobot is attached to the tip of the guidewire, and it is magnetically steered by changing the direction and intensity of an external magnetic field. The microrobot is fabricated via replica molding and features a soft body made of polydimethylsiloxane, two permanent magnets, and a microspring. We developed a mathematical model mapping deformation of the soft microrobot using a feed-forward approach toward steering. Then, we used the model to steer a guidewire. The angulation of the microrobot can be controlled from 21.1° to 132.7° by using a magnetic field of an intensity of 15 mT. Steerability was confirmed by two-dimensional in vitro tracking. Finally, a guidewire with the soft microrobot was tested by using a three-dimensional (3D) phantom of the coronary artery to verify steerability in 3D space.


Assuntos
Magnetismo/instrumentação , Robótica/instrumentação , Cateterismo/instrumentação , Vasos Coronários/fisiologia , Humanos , Campos Magnéticos , Modelos Teóricos , Imagens de Fantasmas
9.
Sci Robot ; 4(30)2019 05 29.
Artigo em Inglês | MEDLINE | ID: mdl-33137727

RESUMO

Magnetic microrobots were developed for three-dimensional culture and the precise delivery of stem cells in vitro, ex vivo, and in vivo. Hippocampal neural stem cells attached to the microrobots proliferated and differentiated into astrocytes, oligodendrocytes, and neurons. Moreover, microrobots were used to transport colorectal carcinoma cancer cells to tumor microtissue in a body-on-a-chip, which comprised an in vitro liver-tumor microorgan network. The microrobots were also controlled in a mouse brain slice and rat brain blood vessel. Last, microrobots carrying mesenchymal stem cells derived from human nose were manipulated inside the intraperitoneal cavity of a nude mouse. The results indicate the potential of microrobots for the culture and delivery of stem cells.

10.
Micromachines (Basel) ; 9(12)2018 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-30477149

RESUMO

Magnetically driven microrobots have been widely studied for various biomedical applications in the past decade. An important application of these biomedical microrobots is heart disease treatment. In intravascular treatments, a particular challenge is the submillimeter-sized guidewire steering; this requires a new microrobotic approach. In this study, a flexible microrobot was fabricated by the replica molding method, which consists of three parts: (1) a flexible polydimethylsiloxane (PDMS) body, (2) two permanent magnets, and (3) a micro-spring connector. A mathematical model was developed to describe the relationship between the magnetic field and the deformation. A system identification approach and an algorithm were proposed for steering. The microrobot was fabricated, and the models for steering were experimentally validated under a magnetic field intensity of 15 mT. Limitations to control were identified, and the microrobot was steered in an arbitrary path using the proposed model. Furthermore, the flexible microrobot was steered using the guidewire within a three-dimensional (3D) transparent phantom of the right coronary artery filled with water, to show the potential application in a realistic environment. The flexible microrobot presented here showed promising results for enhancing guidewire steering in percutaneous coronary intervention (PCI).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA