Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Angew Chem Int Ed Engl ; 62(30): e202306017, 2023 Jul 24.
Artigo em Inglês | MEDLINE | ID: mdl-37243414

RESUMO

Inducing strong metal-support interaction (SMSI) has been a useful way to control the structure of surface active sites. The SMSI often causes the encapsulation of metal particles with an oxide layer. Herein, an amorphous ceria shell was formed on Cu nanoparticles under a mild gas condition with high activity and durability for surface reaction. Cu-Ce solid solution promoted the transfer of surface oxygen species, which induced the ceria shell formation on Cu nanoparticles. This catalyst was used for CO2 hydrogenation, selectively producing CO with high low-temperature activity and good durability for operation at high temperature. CO2 activation and H2 spillover could occur at low temperatures, enhancing the activity. The shell prevented the sintering, assuring durability. This catalyst was applied to a bench-scale reactor without loss in performance, resulting in high CO productivity in all temperature ranges.

2.
Int J Mol Sci ; 23(24)2022 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-36555137

RESUMO

Breast cancer is the most commonly diagnosed cancer worldwide and ranks first in terms of both prevalence and cancer-related mortality in women. In this study, we aimed to evaluate the anticancer effect of mebendazole (MBZ) and radiotherapy (RT) concomitant use in triple-negative breast cancer (TNBC) cells and elucidate the underlying mechanisms of action. Breast cancer mouse models and several types of breast cancer cells, including TNBC-derived RT-resistant (RT-R) MDA-MB-231 cells, were treated with MBZ and/or RT. In mice, changes in body weight, renal and liver toxicity, tumor volume, and number of lung metastases were determined. In cells, cell viability, colony formation, scratch wound healing, Matrigel invasion, and protein expression using western blotting were determined. Our findings showed that MBZ and RT combined treatment increased the anticancer effect of RT without additional toxicity. In addition, we noted that cyclin B1, PH2AX, and natural killer (NK) cell-mediated cytotoxicity increased following MBZ + RT treatment compared to unaided RT. Our results suggest that MBZ + RT have an enhanced anticancer effect in TNBC which acquires radiation resistance through blocking cell cycle progression, initiating DNA double-strand breaks, and promoting NK cell-mediated cytotoxicity.


Assuntos
Mebendazol , Neoplasias de Mama Triplo Negativas , Humanos , Feminino , Camundongos , Animais , Mebendazol/farmacologia , Mebendazol/uso terapêutico , Linhagem Celular Tumoral , Neoplasias de Mama Triplo Negativas/tratamento farmacológico , Neoplasias de Mama Triplo Negativas/radioterapia , Neoplasias de Mama Triplo Negativas/patologia , Apoptose , Células Matadoras Naturais , Proliferação de Células
3.
Int J Mol Sci ; 22(19)2021 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-34638817

RESUMO

Local radiotherapy (RT) is important to manage metastatic triple-negative breast cancer (TNBC). Although RT primarily reduces cancer cells locally, this control can be enhanced by triggering the immune system via immunotherapy. RT and immunotherapy may lead to an improved systemic effect, known as the abscopal effect. Here, we analyzed the antitumor effect of combination therapy using RT with an anti-programmed cell death-1 (PD-1) antibody in primary tumors, using poorly immunogenic metastatic mouse mammary carcinoma 4T1 model. Mice were injected subcutaneously into both flanks with 4T1 cells, and treatment was initiated 12 days later. Mice were randomly assigned to three treatment groups: (1) control (no treatment with RT or immune checkpoint inhibitor (ICI)), (2) RT alone, and (3) RT+ICI. The same RT dose was prescribed in both RT-alone and RT+ICI groups as 10Gy/fx in two fractions and delivered to only one of the two tumor burdens injected at both sides of flanks. In the RT+ICI group, 200 µg fixed dose of PD-1 antibody was intraperitoneally administered concurrently with RT. The RT and ICI combination markedly reduced tumor cell growth not only in the irradiated site but also in non-irradiated sites, a typical characteristic of the abscopal effect. This was observed only in radiation-sensitive cancer cells. Lung metastasis development was lower in RT-irradiated groups (RT-only and RT+ICI groups) than in the non-irradiated group, regardless of the radiation sensitivity of tumor cells. However, there was no additive effect of ICI on RT to control lung metastasis, as was already known regarding the abscopal effect. The combination of local RT with anti-PD-1 blockade could be a promising treatment strategy against metastatic TNBC. Further research is required to integrate our results into a clinical setting.


Assuntos
Inibidores de Checkpoint Imunológico/farmacologia , Neoplasias Pulmonares/prevenção & controle , Neoplasias Mamárias Experimentais/terapia , Tolerância a Radiação/efeitos dos fármacos , Animais , Linhagem Celular Tumoral , Feminino , Neoplasias Pulmonares/imunologia , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/secundário , Neoplasias Mamárias Experimentais/imunologia , Neoplasias Mamárias Experimentais/patologia , Camundongos , Camundongos Endogâmicos BALB C , Metástase Neoplásica , Tolerância a Radiação/imunologia , Tolerância a Radiação/efeitos da radiação
4.
Molecules ; 26(17)2021 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-34500557

RESUMO

In this study, we aimed to evaluate the anticancer effect of benzimidazole derivatives on triple-negative breast cancer (TNBC) and investigate its underlying mechanism of action. Several types of cancer and normal breast cells including MDA-MB-231, radiotherapy-resistant (RT-R) MDA-MB-231, and allograft mice were treated with six benzimidazole derivatives including mebendazole (MBZ). Cells were analyzed for viability, colony formation, scratch wound healing, Matrigel invasion, cell cycle, tubulin polymerization, and protein expression by using Western blotting. In mice, liver and kidney toxicity, changes in body weight and tumor volume, and incidence of lung metastasis were analyzed. Our study showed that MBZ significantly induced DNA damage, cell cycle arrest, and downregulation of cancer stem cell markers CD44 and OCT3/4, and cancer progression-related ESM-1 protein expression in TNBC and RT-R-TNBC cells. In conclusion, MBZ has the potential to be an effective anticancer agent that can overcome treatment resistance in TNBC.


Assuntos
Antineoplásicos/farmacologia , Benzimidazóis/farmacologia , Mebendazol/farmacologia , Neoplasias de Mama Triplo Negativas/tratamento farmacológico , Animais , Biomarcadores Tumorais/metabolismo , Pontos de Checagem do Ciclo Celular/efeitos dos fármacos , Linhagem Celular Tumoral , Proliferação de Células/efeitos dos fármacos , Dano ao DNA/efeitos dos fármacos , Regulação para Baixo/efeitos dos fármacos , Feminino , Humanos , Rim/efeitos dos fármacos , Rim/metabolismo , Fígado/efeitos dos fármacos , Fígado/metabolismo , Neoplasias Pulmonares/metabolismo , Células MCF-7 , Camundongos , Camundongos Nus , Células-Tronco Neoplásicas/efeitos dos fármacos , Células-Tronco Neoplásicas/metabolismo , Neoplasias de Mama Triplo Negativas/metabolismo
5.
Gynecol Oncol ; 158(1): 117-122, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32354468

RESUMO

OBJECTIVE: This study aimed to assess the risks of intraoperative and postoperative urologic complications between laparoscopic radical hysterectomy (LRH) and abdominal radical hysterectomy (ARH). METHODS: Using the database of the National Health Insurance Service (NHIS) and Health Insurance Review & Assessment (HIRA), we identified all Korean women who underwent radical hysterectomy between 2006 and 2018. Intraoperative and postoperative urologic complications were compared between the ARH and LRH groups. RESULTS: A total of 11,399 patients were identified to ARH and 8435 patients to LRH. Urologic complications occurred in 292 of 19,774 patients (1.48%) who underwent radical hysterectomy. LRH was associated with higher complication rates than ARH, although with a borderline significance (OR: 1.23; 90% CI: 1.02-1.51, p = 0.066). There was no difference in intraoperative urologic complications between the ARH and the LRH groups (OR: 1.1 95% CI: 0.86-1.43, p < 0.435). The incidence of postoperative urologic complications was significantly higher in the LRH group (OR: 2.01; 95% CI: 1.18-3.47, p = 0.009). In terms of postoperative urologic complications, the risk of ureterovaginal fistula was not significant between the two groups (OR: 1.53; 95% CI: 0.54-4.24, p = 0.403), whereas the risk of vesicovaginal fistula was significantly higher in the LRH group (OR: 2.24; 95% CI: 1.09-4.58, p = 0.028). There were no significant differences in the overall and urinary tract-specific complications between ARH and LRH in groups under 40 years of age and during the second half (2013-2018), with 2012 as the boundary. CONCLUSION: Among specific urologic complications, the incidence of vesicovaginal fistula was significantly higher in the LRH group than in the ARH group.


Assuntos
Histerectomia/estatística & dados numéricos , Doenças Urológicas/epidemiologia , Adulto , Idoso , Feminino , Humanos , Histerectomia/efeitos adversos , Histerectomia/métodos , Incidência , Laparoscopia/efeitos adversos , Laparoscopia/métodos , Laparoscopia/estatística & dados numéricos , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etnologia , República da Coreia/epidemiologia , Doenças Urológicas/etiologia , Fístula Vesicovaginal/epidemiologia , Fístula Vesicovaginal/etiologia
6.
Angew Chem Int Ed Engl ; 59(46): 20691-20696, 2020 Nov 09.
Artigo em Inglês | MEDLINE | ID: mdl-32720448

RESUMO

Single-atom catalysts (SACs) have emerged as promising materials in heterogeneous catalysis. Previous studies reported controversial results about the relative level in activity for SACs and nanoparticles (NPs). These works have focused on the effect of metal atom arrangement, without considering the oxidation state of the SACs. Here, we immobilized Pt single atoms on defective ceria and controlled the oxidation state of Pt SACs, from highly oxidized (Pt0 : 16.6 at %) to highly metallic states (Pt0 : 83.8 at %). The Pt SACs with controlled oxidation states were then employed for oxidation of CO, CH4 , or NO, and their activities compared with those of Pt NPs. The highly oxidized Pt SACs presented poorer activities than Pt NPs, whereas metallic Pt SACs showed higher activities. The Pt SAC reduced at 300 °C showed the highest activity for all the oxidations. The Pt SACs with controlled oxidation states revealed a crucial missing link between activity and SACs.

7.
Environ Sci Technol ; 53(5): 2900-2907, 2019 03 05.
Artigo em Inglês | MEDLINE | ID: mdl-30785736

RESUMO

A lean NO x trap (LNT) catalyst has been widely used for removing NO x exhaust from lean-burn engines. However, the operation range of LNT has been limited because of the poor activity of LNT catalysts at low temperatures (≤300 °C), especially in urban driving conditions. To increase NO x removal efficiency during lean-rich cycle operation, a Cu/CeO2 (CC) catalyst was added to a Pt-BaO/CeO2 (PBC) catalyst. In comparison to PBC- or CC-only catalysts, the physical mixture of PBC and CC catalysts (PBC + CC) exhibited a significant synergy for both NO x storage and reduction efficiencies. In particular, low-temperature activity below 200 °C was greatly enhanced. A Pt-BaO-Cu/CeO2 (PBCC) catalyst, which was synthesized by depositing Pt and Cu together on a ceria support, showed poorer NO x removal efficiency. The origin of the synergistic effect over PBC + CC was investigated. Under lean conditions, the CC showed much better activity for NO oxidation, allowing for faster NO x storage on PBC. Under rich conditions, H2 was generated in situ on the CC by a water-gas shift reaction then accelerated the reduction of NO x, which had been stored on PBC, with a higher selectivity to N2. This simple modification in the catalyst can provide an important clue to enhance low-temperature activity of the commercial LNT system.


Assuntos
Temperatura Baixa , Emissões de Veículos , Catálise , Oxirredução , Temperatura
8.
Arch Orthop Trauma Surg ; 139(11): 1579-1586, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31278509

RESUMO

INTRODUCTION: When locking intramedullary nails, inserting the distal interlocking screw accurately and quickly with less radiation exposure is very important. The purpose of this randomized control study was to compare radiation exposure and accuracy of distal locking screws between free-hand fluoroscopic guidance and the use of a distal targeting system (DTS). MATERIALS AND METHODS: Inclusion criteria of this study were patients older than 60 years who need an intramedullary nailing due to unstable intertrochanteric and subtrochanteric fracture. The primary outcome was the attempt numbers of image intensifier during the insertion of distal locking screws. Secondary outcomes were operative time and angles between distal locking screws and nail. RESULTS: A total of 36 patients participated in the study. Eighteen patients using free-hand fluoroscopic guidance were assigned to Group I while 18 patients using DTS were assigned to Group II. The number of attempts of image intensifier during distal screw insertion (57.3 ± 31.42 vs. 11.5 ± 7.41, p < 0.001), ratio of attempt number for distal screws to the total attempts (0.33 ± 0.21 vs. 0.12 ± 0.08, p = 0.001), the number of hand exposure to image intensifier directly (75.0 ± 29.55 vs. 13.5 ± 19.07, p < 0.001), and the time of radiation exposure during distal screws insertion (42.57 ± 2.42 s vs. 12.72 ± 8.10 s, p < 0.001) were significantly lower in Group II compared to those in Group I. And, operation time (96.3 min ± 18.94 vs. 76.1 min ± 14.10, p < 0.001) was also statistically significantly lower in Group II. Both distal locking screws were significantly closer to perpendicular direction to the nail in Group II. CONCLUSION: The attempt number of image intensifier during the insertion of two distal locking screws was significantly reduced with DTS compared with that with free hand fluoroscopic guidance. Angle between distal locking screws and nail was also more accurate using DTS.


Assuntos
Fluoroscopia , Fixação Intramedular de Fraturas , Exposição à Radiação/estatística & dados numéricos , Cirurgia Assistida por Computador , Fluoroscopia/instrumentação , Fluoroscopia/métodos , Fluoroscopia/estatística & dados numéricos , Fixação Intramedular de Fraturas/instrumentação , Fixação Intramedular de Fraturas/métodos , Fixação Intramedular de Fraturas/estatística & dados numéricos , Humanos , Período Intraoperatório , Pessoa de Meia-Idade , Duração da Cirurgia , Cirurgia Assistida por Computador/instrumentação , Cirurgia Assistida por Computador/métodos , Cirurgia Assistida por Computador/estatística & dados numéricos
9.
J Am Chem Soc ; 140(30): 9558-9565, 2018 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-29975515

RESUMO

Minimizing the use of precious metal catalysts is important in many applications. Single-atom catalysts (SACs) have received much attention because all of the metal atoms can be used for surface reactions. However, SACs cannot catalyze some important reactions that require ensemble sites. Here, Rh catalysts were prepared by treating 2 wt % Rh/CeO2 hydrothermally at 750 °C for 25 h. Nearly 100% dispersion was obtained, but the surface Rh atoms were not isolated (denoted as ENS). They catalyzed the oxidation of C3H6 or C3H8 at low temperatures, but these oxidations did not occur on the Rh SAC. When the simultaneous oxidation of CO, C3H6, and C3H8 was performed, the T20 (temperature at conversion 20%) for CO oxidation increased significantly from 40 °C for sole CO oxidation to 180 °C on SAC due to the competitive adsorption of hydrocarbons. However, T20 increased much less on ENS, from 60 to 100 °C. ENS exhibited superior activity for low-temperature oxidation. During hydrothermal treatment for 25 h, the Rh size initially increased from 2.3 to 6.7 nm then decreased to 0.9 nm. The surface hydroxyl groups formed on the catalyst surface help detach Rh atoms from Rh clusters, while preventing the reaggregation of dispersed Rh atoms into Rh clusters. This fully dispersed catalyst would have maximum atom-efficiency while catalyzing various surface reactions.

10.
Acta Oncol ; 57(10): 1359-1366, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30004264

RESUMO

BACKGROUND: The aim of the present study was to verify the dosimetric accuracy of two-dimensional (2D) in vivo rectal dosimetry using an endorectal balloon (ERB) with unfoldable EBT3 films for high-dose-rate (HDR) brachytherapy for cervical cancer. The clinical applicability of the technique was discussed. MATERIAL AND METHODS: ERB inflation makes the EBT3 films unrolled, whereas its deflation makes them rolled. Patient-specific quality assurance (pQA) tests were performed in 20 patient plans using an Ir-192 remote afterloading system and a water-filled cervical phantom with the ERB. The dose distributions measured in ERBs were compared with those of the treatment plans. RESULTS: The absolute dose profiles measured by the ERBs were in good agreement with those of treatment plans. The global gamma passing rates were 96-100% and 91-100% over 20 pQAs under the criteria of 3%/3 mm and 3%/2 mm, respectively, with a 30% low-dose threshold. Dose-volume histograms of the rectal wall were obtained from the measured dose distributions and showed small volume differences less than 2% on average from the patients' plans over the entire dose interval. The positioning error of the applicator set was detectable with high sensitivity of 12% dose area variation per mm. Additionally, the clinical applicability of the ERB was evaluated in volunteers, and none of them felt any pain when the ERB was inserted or removed. CONCLUSIONS: The 2D in vivo rectal dosimetry using the ERB with EBT3 films was effective and might be clinically applicable for HDR brachytherapy for cervical and prostate cancers to monitor treatment accuracy and consistency as well as to predict rectal toxicity.


Assuntos
Braquiterapia/métodos , Reto/efeitos da radiação , Neoplasias do Colo do Útero/radioterapia , Feminino , Humanos , Imagens de Fantasmas , Dosagem Radioterapêutica
11.
J Korean Med Sci ; 33(18): e135, 2018 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-29713255

RESUMO

BACKGROUND: Although intracavitary radiotherapy (ICR) is essential for the radiation therapy of cervical cancer, few institutions in Korea perform 3-dimensional (3D)-based ICR. To identify patients who would benefit from 3D-based ICR, dosimetric parameters for tumor targets and organs at risk (OARs) were compared between 2-dimensional (2D)- and 3D-based ICR. METHODS: Twenty patients with locally advanced cervical cancer who underwent external beam radiation therapy (EBRT) following 3D-based ICR were retrospectively evaluated. New 2D-based plans based on the Manchester system were developed. Tumor size was measured by magnetic resonance imaging. RESULTS: The mean high risk clinical target volume (HR-CTV) D90 value was about 10% lower for 2D- than for 3D-based plans (88.4% vs. 97.7%; P = 0.068). Tumor coverage did not differ between 2D- and 3D-based plans in patients with tumors ≤ 4 cm at the time of brachytherapy, but the mean HR-CTV D90 values in patients with tumors > 4 cm were significantly higher for 3D-based plans than for 2D-based plans (96.0% vs. 78.1%; P = 0.017). Similar results were found for patients with tumors > 5 cm initially. Other dosimetric parameters for OARs were similar between 2D- and 3D-based plans, except that mean sigmoid D2cc was higher for 2D- than for 3D-based plans (67.5% vs. 58.8%; P = 0.043). CONCLUSION: These findings indicate that 3D-based ICR plans improve tumor coverage while satisfying the dose constraints for OARs. 3D-based ICR should be considered in patients with tumors > 4 cm size at the time of brachytherapy or > 5 cm initially.


Assuntos
Imageamento Tridimensional , Planejamento da Radioterapia Assistida por Computador , Neoplasias do Colo do Útero/radioterapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Braquiterapia , Feminino , Humanos , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Órgãos em Risco/efeitos da radiação , Dosagem Radioterapêutica , Estudos Retrospectivos , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/patologia
12.
J Korean Med Sci ; 33(14): e107, 2018 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-29607633

RESUMO

BACKGROUND: To analyze clinical outcome of CyberKnife (CK) tumor-tracking stereotactic body radiotherapy (SBRT) for prostate cancer (Pca) according to the magnitude of intra-fractional prostate motion. METHODS: Medical records and daily treatment logs for 71 patients who received CK tumor-tracking SBRT were retrospectively analyzed. Statistical relationships between prostate motion and various outcome results, including local recurrence (LR), biochemical failure (BF), and treatment-related toxicity, were investigated in order to evaluate motion-dependent efficacy of tumor-tracking SBRT for Pca. RESULTS: In a total 71 patients, 3 (4.2%) patients with LR, 12 (16.9%) patients with BF, and 22 (31%) patients with grade-II or worse toxicities to rectal or bladder (22 to rectal, 22 to bladder and 8 patients to both) were observed in a median follow-up of 47 months. Magnitudes of intra-fractional tumor motion along superior-inferior, right-left, and anterior-posterior (AP) axes were 0.15 ± 0.31, 0.12 ± 0.19, and 0.73 ± 0.32 mm, respectively. Radial magnitude was estimated to be 1.0 ± 0.35 mm. Intra-fractional movement was not significantly correlated with tumor control. However, it was significant correlated with the incidence of grade-II or worse toxicity to rectum or bladder particularly when tumor motion was in the AP axis. CONCLUSION: Our quantitative results revealed that toxicity related to SBRT treatment was highly sensitive to intra-fractional prostate movements, although local-tumor control was not affected by such movements. Our results demonstrate that precise motion correction is essential in prostate SBRT, even if it seems to be small.


Assuntos
Neoplasias da Próstata/radioterapia , Radiocirurgia/métodos , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia , Estadiamento de Neoplasias , Próstata/diagnóstico por imagem , Próstata/fisiologia , Neoplasias da Próstata/mortalidade , Neoplasias da Próstata/patologia , Curva ROC , Lesões por Radiação/etiologia , Reto/patologia , Reto/efeitos da radiação , Estudos Retrospectivos , Taxa de Sobrevida , Bexiga Urinária/patologia , Bexiga Urinária/efeitos da radiação
13.
J Phys Ther Sci ; 30(8): 984-987, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30154586

RESUMO

[Purpose] This study investigated the effect of respiratory exercise on pulmonary function, balance, and gait in chronic stroke patients. [Participants and Methods] Twenty patients with chronic stroke were randomly assigned to experimental and control groups (n=10 each). The patients in both groups underwent neurodevelopmental treatment. Moreover, the experimental group performed respiratory exercise. Pulmonary function was measured using a pneumatometer. Balance was measured using a Berg Balance Scale and Functional Reach Test. Gait was measured with a 10-m walk test and Timed Up-and-Go Test. [Results] Intragroup comparison showed significant differences in forced vital capacity, forced expiratory volume in one second, Berg Balance Scale, Functional Reach Test, 10-meter walk test, and Timed Up-and-Go Test. Intergroup comparison showed that the differences in forced vital capacity, forced expiratory volume in one second, Berg Balance Scale, Functional Reach Test, 10-meter walk test, and Timed Up-and-Go Test for the experimental group were significantly related to those for the control group. [Conclusion] Based on these results it was concluded that respiratory exercise effectively improves the pulmonary function, balance, and gait in patients with chronic stroke.

14.
J Phys Ther Sci ; 30(3): 479-480, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29581675

RESUMO

[Purpose] The purpose of this study was to identify the effects of pain scrambler therapy on the pain and quality of life of degenerative gonarthritis patients. [Subject and Methods] This study is a single case study. Pain scrambler therapy was applied for 40 minutes per session once a day for 15 days to a 62-year-old female patient diagnosed with degenerative gonarthritis. Pain was measured using the Visual Analogue Scale and quality of life was measured using the short form-36 item after therapy. [Results] Decrease in pain and improved quality of life were evident after pain scrambler therapy. [Conclusion] Pain scrambler therapy had a potential to decrease pain and improve the quality of life in degenerative gonarthritis patients.

15.
Int J Colorectal Dis ; 32(5): 723-727, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27885479

RESUMO

PURPOSE: Rectal cancer patients with a pathological complete response (pCR) after neoadjuvant concurrent chemoradiotherapy (CCRT) have a better prognosis compared to those without a pCR. Therefore, the "Wait and See" (W&S) approach in those who achieved clinically complete response (cCR) after CCRT was introduced as an alternative modality to the total mesorectal excision (TME). The aim of this study was to compare the oncological outcomes between W&S and TME via meta-analysis. METHODS: We performed a comprehensive literature search on January 14, 2016, using MEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials, Web of Science, and Scopus. In addition, the references of all articles obtained were searched manually. The qualities of each study were assessed using the Newcastle-Ottawa quality assessment scale. The main outcomes were recurrence, disease-free survival (DFS), and overall survival (OS). We calculated the risk ratio (RR) and hazard ratio (HR) for the recurrence and survival rates, respectively. RESULTS: The RR of patients whose initial recurrences was local recurrence (LR), distant metastasis (DM), LR + DM, or overall recurrences were 0.18, 1.00, 0.61, and 0.49, respectively. There was no heterogeneity in the results. The HR of DFS was 0.59 and indicated that DFS in the TME group was superior compared with that in the W&S group. The OS has no significant difference between the studies. CONCLUSIONS: Although the W&S approach seemed feasible for rectal cancer patients with a cCR after neoadjuvant CCRT, concrete evidence obtained in well-controlled randomized trials with a long-term follow-up is required to validate potential treatment options.


Assuntos
Quimiorradioterapia , Terapia Neoadjuvante , Neoplasias Retais/terapia , Conduta Expectante , Humanos , Neoplasias Retais/cirurgia , Reto/cirurgia , Resultado do Tratamento
16.
Opt Express ; 24(15): 16904-12, 2016 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-27464142

RESUMO

We present a systematic, theoretical investigation of the polar magneto-optical (MO) Kerr effects of a single Ni nanorod in the Mie regime. The MO Kerr rotation, ellipticity, amplitude ratio, and phase shift are calculated as a function of the length and width of the nanorod. The electric field amplitude ratio of the MO Kerr effect is locally maximized when the nanorod supports a plasmonic resonance in the polarization state orthogonal to the incident light. The plasmonic resonances directly induced by the incident light do not enhance the amplitude ratio. In the Mie regime, multiple local maxima of the MO Kerr activity are supported by the resonant modes with different modal characteristics. From the viewpoint of first-order perturbation analysis, the spatial overlap between the incident-light-induced electric field and the Green function determines the local maxima.

17.
J Korean Med Sci ; 30(6): 710-5, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26028922

RESUMO

The aim of the present study was to evaluate the efficacy and toxicity of stereotactic body radiation therapy (SBRT) for low- to intermediate-risk prostate adenocarcinoma. Thirty-nine patients were retrospectively reviewed. The SBRT was delivered using the CyberKnife with the fiducial tracking method combined with In-tempo imaging. The gross target volume, which included the prostate only, was delineated on the fused CT/MRI scans. The prescription dose was delivered every other day as 5 fractions of 7.5 Gy. Venous blood was obtained before and after SBRT to assess the prostate-specific antigen (PSA) level. Toxicity was evaluated using the CTCAE, v4.03. The median follow-up time was 30.0 months. The median initial PSA level was 7.7 ng/mL. PSA levels decreased in all patients treated with SBRT, and after 5 months, the median PSA was less than 2 ng/mL. The rate of overall 3-yr actuarial biochemical failure free survival was 93.9%. Acute side effects were generally comparable with those of previous studies. The PSA change and toxicity after SBRT for low- to intermediate-risk prostate adenocarcinoma indicates favorable biochemical responses and tolerable levels of toxicity. Additionally short course treatment may produce cost benefit and convenience to patients.


Assuntos
Adenocarcinoma/diagnóstico , Adenocarcinoma/cirurgia , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/cirurgia , Radiocirurgia/métodos , Radioterapia Guiada por Imagem/métodos , Idoso , Idoso de 80 Anos ou mais , Humanos , Masculino , Pessoa de Meia-Idade , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Medição de Risco , Resultado do Tratamento
18.
J Appl Clin Med Phys ; 16(5): 193-204, 2015 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-26699300

RESUMO

We have investigated the combined effect of tissue heterogeneity and its variation associated with geometric error in stereotactic body radiotherapy (SBRT) for lung cancer. The treatment plans for eight lung cancer patients were calculated using effective path length (EPL) correction and Monte Carlo (MC) algorithms, with both having the same beam configuration for each patient. These two kinds of plans for individual patients were then subsequently recalculated with adding systematic and random geometric errors. In the ordinary treatment plans calculated with no geometric offset, the EPL calculations, compared with the MC calculations, largely overestimated the doses to PTV by ~ 21%, whereas the overestimation were markedly lower in GTV by ~ 12% due to relatively higher density of GTV than of PTV. When recalculating the plans for individual patients with assigning the systematic and random geometric errors, no significant changes in the relative dose distribution, except for overall shift, were observed in the EPL calculations, whereas largely altered in the MC calculations with a consistent increase in dose to GTV. Considering the better accuracy of MC than EPL algorithms, the present results demonstrated the strong coupling of tissue heterogeneity and geometric error, thereby emphasizing the essential need for simultaneous correction for tissue heterogeneity and geometric targeting error in SBRT of lung cancer.


Assuntos
Tomografia Computadorizada Quadridimensional/métodos , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/cirurgia , Radiocirurgia/métodos , Erros de Configuração em Radioterapia , Cirurgia Assistida por Computador/métodos , Algoritmos , Tomografia Computadorizada Quadridimensional/instrumentação , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Método de Monte Carlo , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Carga Tumoral
19.
J Appl Clin Med Phys ; 14(2): 4055, 2013 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-23470935

RESUMO

We evaluated the dosimetric effect of a respiration motion, and sought an effective planning strategy to compensate the motion using four-dimensional computed tomography (4D CT) dataset of seven selected liver patients. For each patient, we constructed four different proton plans based on: (1) average (AVG) CT, (2) maximum-intensity projection (MIP) CT, (3) AVG CT with density override of tumor volume (OVR), and (4) AVG CT with field-specific proton margin which was determined by the range difference between AVG and MIP plans (mAVG). The overall effectiveness of each planning strategy was evaluated by calculating the cumulative dose distribution over an entire breathing cycle. We observed clear differences between AVG and MIP CT-based plans, with significant underdosages at expiratory and inspiratory phases, respectively. Only the mAVG planning strategy was fully successful as the field-specific proton margin applied in the planning strategy complemented both the limitations of AVG and MIP CT-based strategies. These results demonstrated that respiration motion induced significant changes in dose distribution of 3D proton plans for mobile liver cancer and the changes can be effectively compensated by applying field-specific proton margin to each proton field.


Assuntos
Artefatos , Tomografia Computadorizada Quadridimensional/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Mecânica Respiratória , Humanos , Movimento (Física) , Terapia com Prótons , Dosagem Radioterapêutica , Radioterapia Guiada por Imagem/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
20.
Radiat Oncol J ; 41(4): 283-291, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38185933

RESUMO

PURPOSE: To evaluate set-up error for head and neck cancer (HNC) patients according to each neck lymph node (LN) level. And clinical factors affecting set-up error were analyzed. MATERIALS AND METHODS: Reference points (RP1, RP2, RP3, and RP4) representing neck LN levels I to IV were designated. These RP were contoured on simulation computed tomography (CT) and cone-beam CT of 89 HNC patients with the same standard. After image registration was performed, movement of each RP was measured. Univariable logistic regression analyses were performed to analyze clinical factors related to measured movements. RESULTS: The mean value of deviation of all axes was 1.6 mm, 1.3 mm, 1.8 mm, and 1.5 mm for RP1, RP2, RP3, and RP4, respectively. Deviation was over 3 mm in 24 patients. Movement of more than 3 mm was observed only in RP1 and RP3. In RP1, it was related to bite block use. Movement exceeding 3 mm was most frequently observed in RP3. Primary tumor and metastatic LN volume change were clinical factors related to the RP3 movement. CONCLUSION: Planning target volume margin of 4 mm for neck LN level I, 3 mm for neck LN level II, 5 mm for neck LN level III, and 3 mm for neck LN level IV was required to include all movements of each LN level. In patients using bite block, changes in primary tumor volume, and metastatic LN volume were related to significant movement.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA