Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Sensors (Basel) ; 22(15)2022 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-35957376

RESUMO

Several detectors have been developed to measure radiation doses during radiotherapy. However, most detectors are not flexible. Consequently, the airgaps between the patient surface and detector could reduce the measurement accuracy. Thus, this study proposes a dose measurement system based on a flexible copper indium gallium selenide (CIGS) solar cell. Our system comprises a customized CIGS solar cell (with a size 10 × 10 cm2 and thickness 0.33 mm), voltage amplifier, data acquisition module, and laptop with in-house software. In the study, the dosimetric characteristics, such as dose linearity, dose rate independence, energy independence, and field size output, of the dose measurement system in therapeutic X-ray radiation were quantified. For dose linearity, the slope of the linear fitted curve and the R-square value were 1.00 and 0.9999, respectively. The differences in the measured signals according to changes in the dose rates and photon energies were <2% and <3%, respectively. The field size output measured using our system exhibited a substantial increase as the field size increased, contrary to that measured using the ion chamber/film. Our findings demonstrate that our system has good dosimetric characteristics as a flexible in vivo dosimeter. Furthermore, the size and shape of the solar cell can be easily customized, which is an advantage over other flexible dosimeters based on an a-Si solar cell.


Assuntos
Cobre , Índio , Gálio , Humanos , Doses de Radiação , Radiometria , Selênio , Raios X
2.
Strahlenther Onkol ; 192(12): 922-930, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27734106

RESUMO

OBJECTIVE: The purpose of this work was to identify prognostic factors for survival after magnetic resonance image (MRI)-guided brachytherapy combined with external beam radiotherapy for cervical cancer. MATERIAL AND METHODS: External beam radiotherapy of 45-50.4 Gy was delivered by either three-dimensional conformal radiotherapy or helical tomotherapy. Patients also received high-dose-rate MRI-guided brachytherapy of 5 Gy in 6 fractions. RESULTS: We analyzed 128 patients with International Federation of Gynecology and Obstetrics stage IB-IVB cervical cancer who underwent MRI-guided brachytherapy. Most patients (96 %) received concurrent chemotherapy. Pelvic lymph node metastases and para-aortic lymphadenopathies were found in 62 % and 14 % of patients, respectively. The median follow-up time was 44 months. Complete remission was achieved in 119 of 128 patients (93 %). The 5­year local recurrence-free, cancer-specific, and overall survival rates were 94, 89, and 85 %, respectively. Negative pelvic lymphadenopathy, gross tumor volume (GTV) dose covering 90 % of the target (GTV D90) of >110 Gy, and treatment duration ≤56 days were associated with better overall survival in univariate analyses. Multivariable analysis showed that GTV D90 of >110 Gy and treatment duration ≤56 days were possibly associated with overall survival with near-significant P-values of 0.062 and 0.073, respectively. CONCLUSIONS: The outcome of MRI-guided brachytherapy combined with external beam radiotherapy in patients with cervical cancer was excellent. GTV D90 of >110 Gy and treatment duration ≤56 days were potentially associated with overall survival.


Assuntos
Braquiterapia/mortalidade , Imageamento por Ressonância Magnética/estatística & dados numéricos , Lesões por Radiação/mortalidade , Radioterapia Guiada por Imagem/mortalidade , Neoplasias do Colo do Útero/mortalidade , Neoplasias do Colo do Útero/radioterapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Braquiterapia/estatística & dados numéricos , Terapia Combinada/mortalidade , Feminino , Humanos , Pessoa de Meia-Idade , Prevalência , Lesões por Radiação/prevenção & controle , Dosagem Radioterapêutica , Radioterapia Guiada por Imagem/métodos , Radioterapia Guiada por Imagem/estatística & dados numéricos , Radioterapia de Intensidade Modulada/mortalidade , Radioterapia de Intensidade Modulada/estatística & dados numéricos , Doenças Retais/mortalidade , Doenças Retais/prevenção & controle , Fatores de Risco , Taxa de Sobrevida , Resultado do Tratamento , Neoplasias do Colo do Útero/patologia
3.
Med Phys ; 50(4): 2402-2416, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36583513

RESUMO

PURPOSE: Various dosimeters have been proposed for skin dosimetry in electron radiotherapy. However, one main drawback of these skin dosimeters is their lack of flexibility, which could make accurate dose measurements challenging due to air gaps between a curved patient surface and dosimeter. Therefore, the purpose of this study is to suggest a novel flexible skin dosimeter based on a thin-film copper indium gallium selenide (CIGS) solar cell, and to evaluate its dosimetric characteristics. METHODS: The CIGS solar cell dosimeter consisted of (a) a customized thin-film CIGS solar cell and (b) a data acquisition (DAQ) system. The CIGS solar cell with a thickness of 0.33 mm was customized to a size of 10 × 10 mm2 . This customized solar cell plays a role in converting therapeutic electron radiation into electrical signals. The DAQ system was composed of a voltage amplifier with a gain of 1000, a voltage input module, a DAQ chassis, and an in-house software. This system converted the electrical analog signals (from solar cell) to digital signals with a sampling rate of ≤50 kHz and then quantified/visualized the digital signals in real time. We quantified the linearity/ sampling rate effect/dose rate dependence/energy dependence/field size output factor/reproducibility/curvature/bending recoverability/angular dependence of the CIGS solar cell dosimeter in therapeutic electron beams. To evaluate clinical feasibility, we measured the skin point doses by attaching the CIGS solar cell to an anthropomorphic phantom surface (for forehead, mouth, and thorax). The CIGS-measured doses were compared with calculated doses (by treatment planning system) and measured doses (by optically stimulated luminescent dosimeter). RESULTS: The normalized signals of the solar cell dosimeter increased linearly as the delivered dose increased. The gradient of the linearly fitted line was 1.00 with an R-square of 0.9999. The sampling rates (2, 10, and 50 kHz) of the solar cell dosimeter showed good performance even at low doses (<50 cGy). The solar cell dosimeter exhibited dose rate independence within 1% and energy independence within 3% error margins. The signals of the solar cell dosimeter were similar (<1%) when penetrating the same side of the CIGS cell regardless of the rotation angle of the solar cell. The field size output factor measured by the solar cell dosimeter was comparable to that measured by the ion chamber. The solar cell signals were similar between the baseline (week 1) and the last time point (week 4). Our detector showed curvature independence within 1.8% (curvatures of <0.10 mm- ) and bending recovery (curvature of 0.10 mm-1 ). The differences between measured doses (CIGS solar cell dosimeter vs. optically stimulated luminescent dosimeter) were 7.1%, 9.6%, and 1.0% for forehead, mouth, and thorax, respectively. CONCLUSION: We present the construction of a flexible skin dosimeter based on a CIGS solar cell. Our findings demonstrate that the CIGS solar cell has a potential to be a novel flexible skin dosimeter for electron radiotherapy. Moreover, this dosimeter is manufactured with low cost and can be easily customized to various size/shape, which represents advantages over other dosimeters.


Assuntos
Cobre , Dosímetros de Radiação , Humanos , Índio , Elétrons , Reprodutibilidade dos Testes , Radiometria
4.
Med Phys ; 49(7): 4768-4779, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35396722

RESUMO

PURPOSE: To evaluate the dosimetric characteristics and applications of a dosimetry system composed of a flexible amorphous silicon thin-film solar cell and scintillator screen (STFSC-SS) for therapeutic X-rays. METHODS: The real-time dosimetry system was composed of a flexible a-Si thin-film solar cell (0.2-mm thick), a scintillator screen to increase its efficiency, and an electrometer to measure the generated charge. The dosimetric characteristics of the developed system were evaluated including its energy dependence, dose linearity, and angular dependence. Calibration factors for the signal measured by the system and absorbed dose-to-water were obtained by setting reference conditions. The application and correction accuracy of the developed system were evaluated by comparing the absorbed dose-to-water measured using a patient treatment beam with that measured using the ion chamber. RESULTS: The responses of STFSC-SS to energy, field size, depth, and source-to-surface distance (SSD) were more dependent on measurement conditions than were the responses of the ion chamber, although the former dependence was due to the scintillator screen, not the solar cell. The signals of STFSC-SS were also dependent on dose rate, while the responses of solar cell alone and scintillator screen were not dependent on dose rate. The scintillator screen reduced the output of solar cell at 6 and 15 MV by 0.60 and 0.55%, respectively. The different absorbed dose-to-water measured using STFSC-SS for patient treatment beam differed by 0.4% compared to those measured using the ionization chamber. The uncertainties of the developed system for 6 and 15 MV photon beams were 1.8 and 1.7%, respectively, confirming the accuracy and applicability of this system. CONCLUSIONS: The thin-film solar cell-based detector developed in this study can accurately measure absorbed dose-to-water. The increased signal resulting from the use of the scintillator screen is advantageous for measuring low doses and stable signal output. In addition, this system is flexible, making it applicable to curved surfaces, such as a patient's body, and is cost-effective.


Assuntos
Radiometria , Silício , Humanos , Radiografia , Radiometria/métodos , Água , Raios X
5.
Brachytherapy ; 16(1): 116-125, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-27876378

RESUMO

PURPOSE: To analyze the toxicities and dose-volume histogram parameters of external-beam and magnetic resonance imaging-based intracavitary brachytherapy in cervical cancer patients. METHODS AND MATERIALS: Acute and late toxicities were assessed in 135 patients divided into four groups: group 1, grade 0; group 2, grades 1-4; group 3, grades 0-1; and group 4, grades 2-4. The doses at the International Commission on Radiation Units and Measurements (DICRU) and minimum doses to the most exposed 0.1, 1, 2, and 5 cc (D0.1cc, D1cc, D2cc, and D5cc) of normal organs were calculated as equivalent doses in 2 Gy (α/ß = 3). RESULTS: The median follow-up was 35.2 months. For rectum, DICRU, D0.1cc, D1cc, and D2cc were significantly different between groups 1 and 2 and DICRU, D0.1cc, and D1cc between groups 3 and 4. For bladder, D0.1cc, D1cc, and D2cc were significantly different between groups 1 and 2 and DICRU, D1cc, D2cc, and D5cc between groups 3 and 4. Grade 2-4 bladder toxicity occurred in fewer patients with D2cc ≤ 95 Gy than those with D2cc > 95 Gy (7% vs. 22%, p = 0.014). CONCLUSIONS: DICRU, D0.1cc, D1cc, and D2cc are relevant for predicting late rectal toxicities. The patients with bladder D2cc > 95 Gy are required to be in close observation for severe late toxicities.


Assuntos
Adenocarcinoma/radioterapia , Braquiterapia/métodos , Carcinoma Adenoescamoso/radioterapia , Carcinoma de Células Escamosas/radioterapia , Lesões por Radiação/epidemiologia , Dosagem Radioterapêutica , Neoplasias do Colo do Útero/radioterapia , Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Braquiterapia/efeitos adversos , Carcinoma Adenoescamoso/diagnóstico por imagem , Carcinoma Adenoescamoso/patologia , Carcinoma de Células Escamosas/diagnóstico por imagem , Carcinoma de Células Escamosas/patologia , Cistite/epidemiologia , Cistite/etiologia , Diarreia/epidemiologia , Diarreia/etiologia , Feminino , Humanos , Enteropatias/epidemiologia , Enteropatias/etiologia , Intestino Delgado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Órgãos em Risco/diagnóstico por imagem , Lesões por Radiação/etiologia , Planejamento da Radioterapia Assistida por Computador , Reto/diagnóstico por imagem , Bexiga Urinária/diagnóstico por imagem , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA