1.
Regul Toxicol Pharmacol ; 117: 104725, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32768665

RESUMO

We conducted a me-too validation study to confirm the reproducibility, reliability, and predictive capacity of KeraSkin™ skin irritation test (SIT) as a me-too method of OECD TG 439. With 20 reference chemicals, within-laboratory reproducibility (WLR) of KeraSkin™ SIT in the decision of irritant or non-irritant was 100%, 100%, and 95% while between-laboratory reproducibility (BLR) was 100%, which met the criteria of performance standard (PS, WLR≥90%, BLR≥80%). WLR and BLR were further confirmed with intra-class correlation (ICC, coefficients >0.950). WLR and BLR in raw data (viability) were also shown with a scatter plot and Bland-Altman plot. Comparison with existing VRMs with Bland-Altman plot, ICC and kappa statistics confirmed the compatibility of KeraSkin™ SIT with OECD TG 439. The predictive capacity of KeraSkin™ SIT was estimated with 20 reference chemicals (the sensitivity of 98.9%, the specificity of 70%, and the accuracy of 84.4%) and additional 46 chemicals (for 66 chemicals [20 + 46 chemicals, the sensitivity, specificity and accuracy: 95.2%, 82.2% and 86.4%]). The receiver operating characteristic (ROC) analysis suggested a potential improvement of the predictive capacity, especially sensitivity, when changing cut-off (50% → 60-75%). Collectively, the me-too validation study demonstrated that KeraSkin™ SIT can be a new me-too method for OECD TG 439.


Assuntos
Epiderme/efeitos dos fármacos , Fidelidade a Diretrizes/normas , Irritantes/toxicidade , Modelos Biológicos , Organização para a Cooperação e Desenvolvimento Econômico/normas , Testes de Irritação da Pele/normas , Epiderme/metabolismo , Epiderme/patologia , Humanos , Irritantes/metabolismo , Testes de Irritação da Pele/métodos
2.
Toxicol Ind Health ; 35(8): 507-519, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31462197

RESUMO

In commercial products such as household deodorants or biocides, didecyldimethylammonium chloride (DDAC) often serves as an antimicrobial agent, citral serves as a fragrance agent, and the excipient ethylene glycol (EG) is used to dissolve the active ingredients. The skin sensitization (SS) potentials of each of these substances are still being debated. Moreover, mixtures of DDAC or citral with EG have not been evaluated for SS potency. The in vitro alternative assay called human Cell Line Activation Test (h-CLAT) and Direct Peptide Reactivity Assay (DPRA) served to address these issues. On three independent runs of h-CLAT, DDAC and citral were predicted to be sensitizers while EG was predicted to be a non-sensitizer and also by the DPRA. Mixtures of DDAC or citral with EG at ratios of 7:3 and 1:4 w/v were all positive by the h-CLAT in terms of SS potential but SS potency was mitigated as the proportion of EG increased. Citral and its EG mixtures were all positive but DDAC and its EG mixtures were all negative by the DPRA, indicating that the DPRA method is not suitable for chemicals with pro-hapten characteristics. Since humans can be occupationally or environmentally exposed to mixtures of excipients with active ingredients, the present study may give insights into further investigations of the SS potentials of various chemical mixtures.


Assuntos
Monoterpenos Acíclicos/efeitos adversos , Etilenoglicol/efeitos adversos , Excipientes/efeitos adversos , Compostos de Amônio Quaternário/efeitos adversos , Testes de Irritação da Pele/métodos , Pele/efeitos dos fármacos , Monoterpenos Acíclicos/administração & dosagem , Alternativas aos Testes com Animais/métodos , Antígeno B7-2/metabolismo , Bioensaio/métodos , Linhagem Celular , Etilenoglicol/administração & dosagem , Excipientes/administração & dosagem , Humanos , Molécula 1 de Adesão Intercelular/metabolismo
3.
Toxicol In Vitro ; 55: 173-184, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30572010

RESUMO

The need for in vitro eye irritation test replacing in vivo is steadily increasing. The MCTT HCE™ eye irritation test (EIT) using 3D reconstructed human cornea-like epithelium, was developed to identify ocular irritants from non-irritants those that are not requiring classification and labelling for eye irritation. Here, we report the results of me-too validation study, which was conducted to evaluate the reliability and relevance of the MCTT HCETM EIT, according to performance standards (PS) of OECD TG 492. The optimal cutoff to determine irritation in the prediction model was preliminarily established at 45% with the receiver operation characteristics (ROC) curve for 141 reference substances. To demonstrate the reproducibility of within- and between-laboratory (WLR and BLR), a set of 30 PS reference chemicals were tested in three laboratories three times. The WLR and BLR concordance with the binary decision of whether non-irritant or irritant was estimated to be 90-100% and 90%, respectively, and both met the PS requirements. The predictive capacity of the respective laboratories for the 30 reference chemicals were evaluated based on three different estimation methods, and the results were comparable, with sensitivity ranging from 89.6 to 93.3%, the specificity ranging from 62.2 to 66.7%, and the accuracy ranging from 75.9 to 80.0%. Additional test with the new set of 30 PS substances in the revised OECD GD 216 yielded a performance of sensitivity ranging from 92.6-93.3%, the specificity 62.2-66.7% and the accuracy 77.4-80.0%. 95.0% sensitivity, 67.2% specificity, and 83.0% accuracy were obtained for 141 reference substances in total. Furthermore, separate cutoffs for liquids and solids, 35% and 60%, respectively, produced better predictivity, which was established as a final prediction model. Collectively, our study demonstrated that MCTT HCETM EIT meets the reproducibility and predictivity criteria stated in OECD TG 492 PS.


Assuntos
Alternativas aos Testes com Animais , Epitélio Corneano/efeitos dos fármacos , Irritantes/toxicidade , Testes de Toxicidade/métodos , Humanos , Reprodutibilidade dos Testes
4.
Molecules ; 13(2): 272-300, 2008 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-18305418

RESUMO

Rutaecarpine is an indolopyridoquinazolinone alkaloid isolated from Evodia rutaecarpa and related herbs, which has shown a variety of intriguing biological properties such as anti-thrombotic, anticancer, anti-inflammatory and analgesic, anti-obesity and thermoregulatory, vasorelaxing activity, as well as effects on the cardiovascular and endocrine systems. Recent progress in the studies on the isolation, synthesis, structure-activity relationship studies, biological activities and metabolism of rutaecarpine are reviewed.


Assuntos
Alcaloides Indólicos/metabolismo , Alcaloides Indólicos/farmacologia , Quinazolinas/metabolismo , Quinazolinas/farmacologia , Animais , Humanos , Alcaloides Indólicos/síntese química , Alcaloides Indólicos/química , Quinazolinas/síntese química , Quinazolinas/química
5.
Toxicol In Vitro ; 39: 58-67, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27876558

RESUMO

Here, we report the results of a prevalidation trial for an in vitro eye irritation test (EIT) using the reconstructed human cornea-like epithelium, MCTT HCE™. The optimal cutoff to determine irritation in the prediction model was established at 35% with the receiver operation characteristics(ROC) curve for 126 substances. Within-lab(WL) and between-lab(BL) reproducibility was tested for 20 reference substances by 3 participating laboratories. Viability data described by mean±SD or ±1/2 difference between duplicate wells, and scatter plots, demonstrated the WL/BL consistency. WL/BL concordance with the binary decision, whether non-irritant or irritant was estimated to be 85-95% and 95%, respectively. WL/BL reproducibility of viability data was further supported by a strong correlation(ICC, r>0.9). WL/BL agreement of binary decisions was also examined by Fleiss' Kappa statistics, which showed a strong level of agreement (>0.78), nevertheless weaker than the reproducibility of the viability. The EIT with MCTT HCE™ exhibited a sensitivity of 82.2% (60/73), a specificity of 81.1% (43/53), and an accuracy of 81.8% (103/126) for 126 reference substances (for liquids; a sensitivity of 100% (47/47), a specificity of 70.6% (24/34), and an accuracy of 87.7% (71/81), and for solids, a sensitivity of 50% (13/26), a specificity of 100% (19/19), and an accuracy of 71.1% (32/45), suggesting that the accuracy is satisfactory but the sensitivity needs improvement, which shall be addressed through correcting the poor sensitivity for solid substances in future full validation trials.


Assuntos
Epitélio Corneano/efeitos dos fármacos , Irritantes/toxicidade , Alternativas aos Testes com Animais , Sobrevivência Celular/efeitos dos fármacos , Humanos , Técnicas In Vitro , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Artigo em Inglês | MEDLINE | ID: mdl-26654807

RESUMO

In order for a novel test method to be applied for regulatory purposes, its reliability and relevance, i.e., reproducibility and predictive capacity, must be demonstrated. Here, we examine the predictive capacity of a novel non-radioisotopic local lymph node assay, LLNA:BrdU-FCM (5-bromo-2'-deoxyuridine-flow cytometry), with a cutoff approach and inferential statistics as a prediction model. 22 reference substances in OECD TG429 were tested with a concurrent positive control, hexylcinnamaldehyde 25%(PC), and the stimulation index (SI) representing the fold increase in lymph node cells over the vehicle control was obtained. The optimal cutoff SI (2.7≤cutoff <3.5), with respect to predictive capacity, was obtained by a receiver operating characteristic curve, which produced 90.9% accuracy for the 22 substances. To address the inter-test variability in responsiveness, SI values standardized with PC were employed to obtain the optimal percentage cutoff (42.6≤cutoff <57.3% of PC), which produced 86.4% accuracy. A test substance may be diagnosed as a sensitizer if a statistically significant increase in SI is elicited. The parametric one-sided t-test and non-parametric Wilcoxon rank-sum test produced 77.3% accuracy. Similarly, a test substance could be defined as a sensitizer if the SI means of the vehicle control, and of the low, middle, and high concentrations were statistically significantly different, which was tested using ANOVA or Kruskal-Wallis, with post hoc analysis, Dunnett, or DSCF (Dwass-Steel-Critchlow-Fligner), respectively, depending on the equal variance test, producing 81.8% accuracy. The absolute SI-based cutoff approach produced the best predictive capacity, however the discordant decisions between prediction models need to be examined further.


Assuntos
Bromodesoxiuridina/análise , Bromodesoxiuridina/química , Citometria de Fluxo/métodos , Ensaio Local de Linfonodo , Animais , Citometria de Fluxo/normas , Previsões , Camundongos , Camundongos Endogâmicos BALB C
7.
Arch Pharm Res ; 34(12): 2073-8, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22210033

RESUMO

Glimepiride, a second-generation sulfonylurea, is a glucose-lowering agent widely used to treat diabetes mellitus. It is converted into metabolite M1 by CYP2C9, and M1 is then transformed into the carboxyl derivative M2 by cytosolic enzymes. In this study, we introduce a sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for determining glimepiride, M1, and M2 in human plasma. After simple protein precipitation with acetonitrile, the analytes were chromatographed on a reversed-phase CN column with a mobile phase of 10 mM ammonium acetate aqueous solution and acetonitrile (1:1, v/v). The accuracy and precision of the assay were in accordance with FDA regulations for the validation of bioanalytical methods. This method was used to measure the concentrations of glimepiride, M1, and M2 in plasma after a single oral 2-mg dose of glimepiride in volunteers.


Assuntos
Compostos de Sulfonilureia/sangue , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida/métodos , Cromatografia Líquida/normas , Humanos , Compostos de Sulfonilureia/metabolismo , Espectrometria de Massas em Tandem/normas
8.
Arch Pharm Res ; 33(2): 267-73, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20195828

RESUMO

Racemic sibutramine is widely used to treat obesity owing to its inhibition of serotonin and noradrenaline reuptake in synapses. Although the enantioselective effects of sibutramine and its two active desmethyl-metabolites, monodesmethylsibutramine (MDS) and didesmethylsibutramine (DDS), on anorexia and energy expenditure have been elucidated, the enantioselective pharmacokinetics of sibutramine are still unclear. Therefore, we aimed to characterize the enantioselective pharmacokinetics of sibutramine and its metabolites in plasma and urine following an intravenous and a single oral administration of sibutramine in rats. The absolute bioavailability of sibutramine was only about 7%. The pharmacologically less effective S-isomer of DDS was predominant in the plasma: the C ( max ) and the AUC ( inf ) were 28 and 30 times higher than those of the R-isomer, respectively (p<0.001). In the urine, the concentrations of the R-isomers of hydroxylated DDS and hydroxylated and carbamoylglucuronized MDS and DDS appeared to be 11.3-, 5.1-, and 5.3-times the concentrations of the respective S-isomers. Thus, regardless of increased potency than the S-enantiomers, the R-enantiomers of the sibutramine metabolites MDS and DDS were present at lower concentrations, owing to their rapid biotransformation to hydroxylated and/or carbamoylglucuronized forms and their faster excretion in the urine. The present study is the first to elucidate the enantioselective pharmacokinetics of sibutramine in rats.


Assuntos
Ciclobutanos/farmacocinética , Administração Oral , Animais , Disponibilidade Biológica , Ciclobutanos/administração & dosagem , Ciclobutanos/química , Injeções Intravenosas , Masculino , Ratos , Ratos Sprague-Dawley , Estereoisomerismo
9.
Biol Pharm Bull ; 29(5): 1060-3, 2006 May.
Artigo em Inglês | MEDLINE | ID: mdl-16651748

RESUMO

The tumoricidal and apoptosis-inducing activities of 5-fluorouracil (5-FU) have been demonstrated in experimental and clinical investigations. Clinically, the 5-FU suppository form has been widely adopted for its advantages of less systemic toxicity, higher local tissue concentrations, and reduced first-pass effect. In this study, we investigated the feasibility of rectal administration of 5-FU suppository based on poloxamer 188 (P188) and propylene glycol (PG) and its anticancer effect on the murine experimental cancer models. The rectal suppository was made with 70% P188 and 30% PG, which was a solid phase at room temperature and instantly melted at physiological temperature. The treatment with the 5-FU suppository was more effective than the oral route in decreasing the volume of rectal cancer in mice. In addition, the survival rate of the mice with rectal cancer was higher in the group treated with the 5-FU suppository than in the group treated with 5-FU orally. Furthermore, in mice skin cancers induced by inoculation of murine CT-26 colon carcinoma cells, the anticancer effect of 5-FU was significantly enhanced by the rectal administration of the suppository than by oral treatment. Taken together, the results suggest that a poloxamer gel system with 5-FU/P188/PG is an effective rectal dosage form for the treatment of both rectal and non-rectal cancers.


Assuntos
Antimetabólitos Antineoplásicos/administração & dosagem , Antimetabólitos Antineoplásicos/farmacologia , Fluoruracila/administração & dosagem , Fluoruracila/farmacologia , Poloxâmero , Propilenoglicol , Administração Retal , Alanina Transaminase/sangue , Animais , Aspartato Aminotransferases/sangue , Linhagem Celular Tumoral , Peroxidação de Lipídeos/efeitos dos fármacos , Camundongos , Camundongos Endogâmicos BALB C , Transplante de Neoplasias , Veículos Farmacêuticos , Neoplasias Retais/tratamento farmacológico , Neoplasias Cutâneas/tratamento farmacológico , Solubilidade , Supositórios