Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur Radiol ; 32(6): 4234-4242, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34993574

RESUMO

OBJECTIVES: We evaluated left atrial (LA) remodeling using cardiac MRI (CMR) in patients with human epidermal growth factor receptor 2 (HER2)-positive breast cancer during and after trastuzumab therapy. METHODS: In this prospective 2-center longitudinal study, 41 women with HER2-positive breast cancer received adjuvant trastuzumab for 12 months, in addition to standard chemotherapy. Serial CMRs were performed at baseline, 6, 12, and 18 months after initiation of trastuzumab. LA volumes were measured by a blinded reader. Linear mixed model was used to evaluate longitudinal changes. RESULTS: Of 41 women (mean age 52 ± 11 [SD] years; 56% received anthracycline), one patient experienced trastuzumab-induced cardiotoxicity (TIC) for which trastuzumab was interrupted for one cycle. Mean baseline left ventricular ejection fraction (LVEF) was 68.0 ± 5.9% and LA ejection fraction (LAEF) was 66.0 ± 6.6%. Compared to baseline, LAEF decreased significantly at 6 months (62.7 ± 5.7%, p = 0.027) and 12 months (62.2 ± 6.1%, p = 0.003), while indexed LA minimum volume (LAmin) significantly increased at 12 months (11.6 ± 4.9 ml/m2 vs 13.8 ± 4.5 ml/m2, p = 0.002). At 18 months, all changes from baseline were no longer significant. From baseline to 6 months, change in LAEF correlated with change in LVEF (Spearman's r = 0.41, p = 0.014). No significant interactions (all p > 0.10) were detected between time and anthracycline use for LA parameters. CONCLUSIONS: Among trastuzumab-treated patients with low incidence of TIC, we observed a small but significant decline in LAEF and increase in LAmin that persisted for the duration of therapy and recovered 6 months after therapy cessation. These findings suggest that trastuzumab has concurrent detrimental effects on atrial and ventricular remodeling. KEY POINTS: • In trastuzumab-treated breast cancer patients evaluated by cardiac MRI, left atrial ejection fraction declined and minimum volume increased during treatment and recovered to baseline after trastuzumab cessation. • Changes in left atrial ejection fraction correlated with changes in left ventricular ejection fraction in the first 6 months of trastuzumab treatment. • Trastuzumab therapy is associated with concurrent detrimental effects on left atrial and ventricular remodeling.


Assuntos
Remodelamento Atrial , Neoplasias da Mama , Disfunção Ventricular Esquerda , Adulto , Antraciclinas/uso terapêutico , Neoplasias da Mama/metabolismo , Cardiotoxicidade/diagnóstico por imagem , Cardiotoxicidade/tratamento farmacológico , Cardiotoxicidade/etiologia , Feminino , Humanos , Laminas/farmacologia , Estudos Longitudinais , Imageamento por Ressonância Magnética/efeitos adversos , Pessoa de Meia-Idade , Estudos Prospectivos , Receptor ErbB-2/metabolismo , Volume Sistólico , Trastuzumab/efeitos adversos , Disfunção Ventricular Esquerda/induzido quimicamente , Disfunção Ventricular Esquerda/complicações , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda , Remodelação Ventricular
2.
Radiology ; 301(2): 322-329, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34402663

RESUMO

Background Right ventricular ejection fraction (RVEF) is an independent predictor of death and adverse cardiovascular outcomes in patients with various cardiac conditions. Purpose To investigate whether RVEF, measured with cardiac MRI, is a predictor of appropriate shock or death in implantable cardioverter-defibrillator (ICD) recipients for primary and secondary prevention of sudden cardiac death. Materials and Methods This retrospective, multicenter, observational study included patients who underwent cardiac MRI before ICD implantation between January 2007 and May 2017. Right ventricular end-diastolic and end-systolic volumes and RVEF were measured with cardiac MRI. The primary end point was a composite of all-cause mortality or appropriate ICD shock. The secondary end point was all-cause mortality. The association between RVEF and primary and secondary outcomes was evaluated by using multivariable Cox regression analysis. Potential interactions were tested between primary prevention, ischemic cause, left ventricular ejection fraction (LVEF), and RVEF. Results Among 411 patients (mean age ± standard deviation, 60 years; 315 men) during a median follow-up of 63 months, 143 (35%) patients experienced an appropriate ICD shock or died. In univariable analysis, lower RVEF was associated with greater risks for appropriate ICD shock or death and for death alone (log-rank trend test, P = .003 and .005 respectively). In multivariable Cox regression analysis adjusting for age at ICD implantation, LVEF, ICD indication (primary vs secondary), ischemic heart disease, and late gadolinium enhancement, RVEF was an independent predictor of the primary outcome (hazard ratio [HR], 1.21 per 10% lower RVEF; 95% CI: 1.04, 1.41; P = .01) and all-cause mortality (HR, 1.25 per 10% lower RVEF; 95% CI: 1.01, 1.55; P = .04). No evidence of significant interactions was found between RVEF and primary or secondary prevention (P = .49), ischemic heart disease (P = .78), and LVEF (P = .29). Conclusion Right ventricular ejection fraction measured with cardiac MRI was a predictor of appropriate implantable cardioverter-defibrillator shock or death. © RSNA, 2021 See also the editorial by Nazarian and Zghaib in this issue. An earlier incorrect version of this article appeared online. This article was corrected on August 24, 2021.


Assuntos
Morte Súbita Cardíaca/epidemiologia , Desfibriladores Implantáveis , Imageamento por Ressonância Magnética/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/epidemiologia , Causalidade , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Ontário/epidemiologia , Valor Preditivo dos Testes , Estudos Retrospectivos , Medição de Risco , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Direita
3.
J Cardiovasc Magn Reson ; 23(1): 72, 2021 06 10.
Artigo em Inglês | MEDLINE | ID: mdl-34108003

RESUMO

BACKGROUND: Current indications for implantable cardioverter defibrillator (ICD) implantation for sudden cardiac death prevention rely primarily on left ventricular (LV) ejection fraction (LVEF). Currently, two different contouring methods by cardiovascular magnetic resonance (CMR) are used for LVEF calculation. We evaluated the comparative prognostic value of these two methods in the ICD population, and if measures of LV geometry added predictive value. METHODS: In this retrospective, 2-center observational cohort study, patients underwent CMR prior to ICD implantation for primary or secondary prevention from January 2005 to December 2018. Two readers, blinded to all clinical and outcome data assessed CMR studies by: (a) including the LV trabeculae and papillary muscles (TPM) (trabeculated endocardial contours), and (b) excluding LV TPM (rounded endocardial contours) from the total LV mass for calculation of LVEF, LV volumes and mass. LV sphericity and sphere-volume indices were also calculated. The primary outcome was a composite of appropriate ICD shocks or death. RESULTS: Of the 372 consecutive eligible patients, 129 patients (34.7%) had appropriate ICD shock, and 65 (17.5%) died over a median duration follow-up of 61 months (IQR 38-103). LVEF was higher when including TPM versus excluding TPM (36% vs. 31%, p < 0.001). The rate of appropriate ICD shock or all-cause death was higher among patients with lower LVEF both including and excluding TPM (p for trend = 0.019 and 0.004, respectively). In multivariable models adjusting for age, primary prevention, ischemic heart disease and late gadolinium enhancement, both LVEF (HR per 10% including TPM 0.814 [95%CI 0.688-0.962] p = 0.016, vs. HR per 10% excluding TPM 0.780 [95%CI 0.639-0.951] p = 0.014) and LV mass index (HR per 10 g/m2 including TPM 1.099 [95%CI 1.027-1.175] p = 0.006; HR per 10 g/m2 excluding TPM 1.126 [95%CI 1.032-1.228] p = 0.008) had independent prognostic value. Higher LV end-systolic volumes and LV sphericity were significantly associated with increased mortality but showed no added prognostic value. CONCLUSION: Both CMR post-processing methods showed similar prognostic value and can be used for LVEF assessment. LVEF and indexed LV mass are independent predictors for appropriate ICD shocks and all-cause mortality in the ICD population.


Assuntos
Desfibriladores Implantáveis , Meios de Contraste , Gadolínio , Humanos , Espectroscopia de Ressonância Magnética , Valor Preditivo dos Testes , Prognóstico , Estudos Retrospectivos , Fatores de Risco
4.
J Cardiovasc Magn Reson ; 23(1): 115, 2021 10 21.
Artigo em Inglês | MEDLINE | ID: mdl-34670574

RESUMO

BACKGROUND: Cardiovascular magnetic resonance (CMR) is increasingly used in the evaluation of patients who are potential candidates for implantable cardioverter-defibrillator (ICD) therapy to assess left ventricular (LV) ejection fraction (LVEF), myocardial fibrosis, and etiology of cardiomyopathy. It is unclear whether CMR-derived strain measurements are predictive of appropriate shocks and death among patients who receive an ICD. We evaluated the prognostic value of LV strain parameters on feature-tracking (FT) CMR in patients who underwent subsequent ICD implant for primary or secondary prevention of sudden cardiac death. METHODS: Consecutive patients from 2 Canadian tertiary care hospitals who underwent ICD implant and had a pre-implant CMR scan were included. Using FT-CMR, a single, blinded, reader measured LV global longitudinal (GLS), circumferential (GCS), and radial (GRS) strain. Cox proportional hazards regression was performed to assess the associations between strain measurements and the primary composite endpoint of all-cause death or appropriate ICD shock that was independently ascertained. RESULTS: Of 364 patients (mean 61 years, mean LVEF 32%), 64(17.6%) died and 118(32.4%) reached the primary endpoint over a median follow-up of 62 months. Univariate analyses showed significant associations between GLS, GCS, and GRS and appropriate ICD shocks or death (all p < 0.01). In multivariable Cox models incorporating LVEF, GLS remained an independent predictor of both the primary endpoint (HR 1.05 per 1% higher GLS, 95% CI 1.01-1.09, p = 0.010) and death alone (HR 1.06 per 1% higher GLS, 95% CI 1.02-1.11, p = 0.003). There was no significant interaction between GLS and indication for ICD implant, presence of ischemic heart disease or late gadolinium enhancement (all p > 0.30). CONCLUSIONS: GLS by FT-CMR is an independent predictor of appropriate shocks or mortality in ICD patients, beyond conventional prognosticators including LVEF. Further study is needed to elucidate the role of LV strain analysis to refine risk stratification in routine assessment of ICD treatment benefit.


Assuntos
Desfibriladores Implantáveis , Canadá , Meios de Contraste , Gadolínio , Humanos , Imageamento por Ressonância Magnética , Imagem Cinética por Ressonância Magnética , Valor Preditivo dos Testes , Volume Sistólico , Função Ventricular Esquerda
5.
Nephrology (Carlton) ; 24(5): 557-563, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-29785733

RESUMO

AIM: Intensified haemodialysis is associated with regression of left ventricular (LV) mass. Compared to LV ejection fraction, LV strain allows more direct assessment of LV function. We sought to assess the impact of in-centre nocturnal haemodialysis (INHD) on global LV strain (radial, circumferential, and longitudinal) and torsion by cardiac MRI (CMR). METHODS: In this prospective, two-centre cohort study, 37 participants on conventional haemodialysis (CHD, 3-4 h/session for three sessions/week) converted to INHD (7-8 h/session for three sessions/week) and 30 participants continued CHD. Participants underwent CMR using a standardized protocol and had biomarker measurements at baseline and 52 weeks. RESULTS: Among the 55 participants (mean age 55; 40% women) with complete CMR data, those who converted to INHD had a significant improvement in their global circumferential strain (GCS, P = 0.025), while those continuing CHD did not have any significant changes in LV strain. When the two groups were compared, there was significant improvement in torsion. LV strains were significantly correlated with each other, but not with troponin I, C-reactive protein, or brain natriuretic protein (NT-proBNP), except for global longitudinal strain (GLS) with troponin I (P = 0.001) and NT-proBNP (P = 0.038). CONCLUSION: Conversion to INHD was associated with significant improvement in GCS over one year of study, although comparisons with the CHD group were not significant. There was also a significant decrease in torsion in the INHD group compared with CHD. Improvement in LV regional function would support the notion that INHD has favourable effects on both LV structure and function.


Assuntos
Ventrículos do Coração/diagnóstico por imagem , Falência Renal Crônica/terapia , Imageamento por Ressonância Magnética , Contração Miocárdica , Diálise Renal/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda , Adulto , Idoso , Fenômenos Biomecânicos , Colúmbia Britânica , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Falência Renal Crônica/diagnóstico , Falência Renal Crônica/fisiopatologia , Masculino , Pessoa de Meia-Idade , Ontário , Valor Preditivo dos Testes , Estudos Prospectivos , Recuperação de Função Fisiológica , Fatores de Tempo , Torção Mecânica , Resultado do Tratamento , Disfunção Ventricular Esquerda/fisiopatologia
6.
Nephrol Dial Transplant ; 33(6): 1010-1016, 2018 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-28992094

RESUMO

Background: In-center nocturnal hemodialysis (INHD) is associated with favorable left ventricular (LV) remodeling. Although right ventricular (RV) structure and function carry prognostic significance, the impact of dialysis intensification on RV is unknown. Our objectives were to evaluate changes in RV mass index (MI), end-diastolic volume index (EDVI), end-systolic volume index (ESVI) and ejection fraction (EF) after conversion to INHD and their relationship with LV remodeling. Methods: Of 67 conventional hemodialysis (CHD, 4 h/session, three times/week) patients, 30 continued on CHD and 37 converted to INHD (7-8 h/session, three times/week). Cardiac magnetic resonance imaging was performed at baseline and 1 year using a standardized protocol; an experienced and blinded reader performed RV measurements. Results: At 1 year there were significant reductions in RVMI {-2.1 g/m2 [95% confidence interval (CI) -3.8 to - 0.4], P = 0.017}, RVEDVI [-9.5 mL/m2 (95% CI - 16.3 to - 2.6), P = 0.008] and RVESVI [-6.2 mL/m2 (95% CI - 10.9 to - 1.6), P = 0.011] in the INHD group; no significant changes were observed in the CHD group. Between-group comparisons showed significantly greater reduction of RVESVI [-7.9 mL/m2 (95% CI - 14.9 to - 0.9), P = 0.03] in the INHD group, a nonsignificant trend toward greater reduction in RVEDVI and no significant difference in RVMI and RVEF changes. There was significant correlation between LV and RV in terms of changes in mass index (MI) (r = 0.46), EDVI (r = 0.73), ESVI (r = 0.7) and EF (r = 0.38) over 1 year (all P < 0.01). Conclusions: Conversion to INHD was associated with a significant reduction of RVESVI. Temporal changes in RV mass, volume and function paralleled those of LV. Our findings support the need for larger, longer-term studies to confirm favorable RV remodeling and determine its impact on clinical outcomes.


Assuntos
Cardiopatias/prevenção & controle , Diálise Renal/classificação , Diálise Renal/métodos , Disfunção Ventricular Esquerda/prevenção & controle , Remodelação Ventricular , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos
7.
J Cardiovasc Magn Reson ; 19(1): 44, 2017 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-28395671

RESUMO

BACKGROUND: There are limited data on the effects of trastuzumab on the right ventricle (RV). Therefore, we sought to evaluate the temporal changes in right ventricular (RV) structure and function as measured by cardiovascular magnetic resonance (CMR), and their relationship with left ventricular (LV) structure and function in breast cancer patients treated with trastuzumab. METHODS: Prospective, longitudinal, observational study involving 41 women with HER2+ breast cancer who underwent serial CMR at baseline, 6, 12, and 18 months after initiation of trastuzumab. A single blinded observer measured RV parameters on de-identified CMRs in a random order. Linear mixed models were used to investigate temporal changes in RV parameters. RESULTS: Of the 41 women (age 52 ± 11 years), only one patient experienced trastuzumab-induced cardiotoxicity. Compared to baseline, there were small but significant increases in the RV end-diastolic volume at 6 months (p = 0.002) and RV end-systolic volume at 6 and 12 months (p < 0.001 for both), but not at 18 months (p = 0.82 and 0.13 respectively). RV ejection fraction (RVEF), when compared to baseline (58.3%, 95% CI 57.1-59.5%), showed corresponding decreases at 6 months (53.9%, 95% CI 52.5-55.4%, p < 0.001) and 12 months (55%, 95% CI 53.8-56.2%, p < 0.001) that recovered at 18 months (56.6%, 95% CI 55.1-58.0%, p = 0.08). Although the temporal pattern of changes in LVEF and RVEF were similar, there was no significant correlation between RVEF and LVEF at baseline (r = 0.29, p = 0.07) or between their changes at 6 months (r = 0.24, p = 0.17). CONCLUSION: In patients receiving trastuzumab without overt cardiotoxicity, there is a subtle but significant deleterious effect on RV structure and function that recover at 18 months, which can be detected by CMR. Furthermore, monitoring of LVEF alone may not be sufficient in detecting early RV injury. These novel findings provide further support for CMR in monitoring early cardiotoxicity. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT01022086 . Date of registration: November 27, 2009.


Assuntos
Antineoplásicos Imunológicos/efeitos adversos , Neoplasias da Mama/tratamento farmacológico , Ventrículos do Coração/efeitos dos fármacos , Imagem Cinética por Ressonância Magnética , Trastuzumab/efeitos adversos , Disfunção Ventricular Direita/induzido quimicamente , Função Ventricular Direita/efeitos dos fármacos , Adulto , Análise de Variância , Cardiotoxicidade , Diagnóstico Precoce , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Ventrículos do Coração/fisiopatologia , Humanos , Modelos Lineares , Estudos Longitudinais , Pessoa de Meia-Idade , Ontário , Valor Preditivo dos Testes , Estudos Prospectivos , Recuperação de Função Fisiológica , Método Simples-Cego , Volume Sistólico/efeitos dos fármacos , Fatores de Tempo , Resultado do Tratamento , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/patologia , Disfunção Ventricular Direita/fisiopatologia , Função Ventricular Esquerda/efeitos dos fármacos
8.
J Cardiovasc Magn Reson ; 18(1): 60, 2016 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-27658396

RESUMO

BACKGROUND: Test-retest reproducibility is of utmost importance in follow-up of right ventricular (RV) volumes and function; optimal slice orientation though is not yet known. We compared test-retest reproducibility and intra-/inter-observer variability of right ventricular (RV) volumes and function assessed with short-axis and transverse cardiovascular magnetic resonance (CMR). METHODS: Eighteen volunteers underwent cine CMR for RV assessment obtaining ventricular coverage in short-axis and transverse slice orientation. Additional 2D phase contrast flow imaging of the main pulmonary artery (MPA) was performed. After complete repositioning repeat acquisitions were performed. Data sets were contoured by two blinded observers. Statistical analysis included Student's t-test, Bland-Altman plots, intra-class correlation coefficient (ICC) and 2-way ANOVA, SEM and minimal detectable difference calculations. RESULTS: Heart rates (65.0 ± 7.4 vs. 67.6 ± 9.9 bpm; P = 0.1) and MPA flow (89.8 ± 16.6 vs. 87.2 ± 14.9 mL; P = 0.1) did not differ between imaging sessions. EDV and ESV demonstrated an inter-study bias of 0.4 %[-9.5 %,10.3 %] and 2.1 %[-12.3 %,16.4 %] for short-axis and 1.1 %[-7.3 %,9.4 %] and 0.8 %[-16.0 %,17.6 %] for transverse orientation, respectively. There was no significant interaction between imaging orientation and interstudy reproducibility (p = 0.395-0.824), intra-observer variability (p = 0.726-0.862) or inter-observer variability (p = 0.447-0.706) by 2-way ANOVA. Inter-observer agreement by ICC was greater for short axis versus transverse orientation for all parameters (0.769-0.986 vs. 0.625-0.983, respectively). Minimal detectable differences for short axis and transverse orientations were 10.1 mL/11.5 mL for EDV, 8.3 mL/8.4 mL for ESV and 4.1 % vs. 4.7 % for EF, respectively. CONCLUSION: Short-axis and transverse orientation both provide reliable and reproducible measures for follow-up of RV volumes and global function. Therefore, additional transverse SSFP cine CMR may not necessarily be required if performed for the sole purpose of quantitative volumetric RV assessment.

9.
Eur Radiol ; 24(1): 86-94, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23949725

RESUMO

OBJECTIVES: To compare the image quality and radiation dose using image-noise (IN)-based determination of X-ray tube settings compared with a body mass index (BMI)-based protocol during CT coronary angiography (CTCA). METHODS: Two hundred consecutive patients referred for CTCA to our institution were divided into two groups: BMI-based, 100 patients had CTCA with the X-ray tube current adjusted to the patient's BMI while maintaining a fixed tube potential of 120 kV; IN-based, 100 patients underwent imaging with the X-ray tube current and voltage adjusted to the IN measured within the mid-left ventricle on a pre-acquisition trans-axial image. Two independent cardiac radiologists performed blinded image quality assessment with quantification of the IN and signal-to-noise ratio (SNR) from the mid-LV and qualitative assessment using a three-point score. Radiation dose (CTDI and DLP) was recorded from the console. RESULTS: Results showed: IN (HU): BMI-based, 30.1 ± 9.9; IN-based, 33.1 ± 6.7; 32 % variation reduction (P = 0.001); SNR: BMI-based, 18.6 ± 7.1; IN-based, 15.4 ± 3.7; 48 % variation reduction (P < 0.0001). Visual scores: BMI-based, 2.3 ± 0.6; IN-based, 2.2 ± 0.5 (P = 0.54). Radiation dose: CTDI (mGy), BMI-based, 22.68 ± 8.9; IN-based, 17.16 ± 7.6; 24.3 % reduction (P < 0.001); DLP (mGy.cm), BMI-based, 309.3 ± 127.5; IN-based, 230.6 ± 105.5; 25.4 % reduction (P < 0.001). CONCLUSIONS: Image-noise-based stratification of X-ray tube parameters for CTCA results in 32 % improvement in image quality and 25 % reduction in radiation dose compared with a BMI-based protocol. KEY POINTS: • Image quality and radiation dose are closely related in CT coronary angiography. • So too are the image quality, radiation dose and body mass index (BMI). • An image-noise-based CTCA protocol reduces the radiation dose by 25 %. • It improves inter-patient image homogeneity by 32 %.


Assuntos
Índice de Massa Corporal , Técnicas de Imagem Cardíaca/métodos , Tomografia Computadorizada de Feixe Cônico/normas , Angiografia Coronária/normas , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/métodos , Angiografia Coronária/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Reprodutibilidade dos Testes , Estudos Retrospectivos , Razão Sinal-Ruído
10.
Cardiol Young ; 24(5): 822-30, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24044501

RESUMO

BACKGROUND: Vasodilator stress perfusion cardiovascular magnetic resonance imaging is a clinically useful tool for detection of clinically significant myocardial ischaemia in adults. We report our 5-year retrospective experience with perfusion cardiovascular magnetic resonance in a large, quarternary adult congenital heart disease centre. METHODS: We reviewed all cases of perfusion cardiovascular magnetic resonance in patients referred from the adult congenital heart disease service. Dipyridamole stress perfusion cardiovascular magnetic resonance was undertaken on commercially available 1.5 and 3 T cardiovascular magnetic resonance scanners. Late gadolinium enhancement imaging was performed 8-10 minutes after completion of the rest perfusion sequence. Navigator whole-heart coronary magnetic resonance angiography was also performed where feasible. RESULTS of stress cardiovascular magnetic resonance were correlated with complementary imaging studies, surgery, and clinical outcomes. RESULTS: Over 5 years, we performed 34 stress perfusion cardiovascular magnetic resonance examinations (11 positive). In all, 84% of patients had further investigations for ischaemia in addition to cardiovascular magnetic resonance. Within a subgroup of 19 patients who had definitive alternative assessment of their coronary arteries, stress perfusion cardiovascular magnetic resonance demonstrated a sensitivity of 82% and specificity of 100%. Of the 34 studies, two were false negatives, in which the aetiology of ischaemia was extrinsic arterial compression rather than intrinsic coronary luminal narrowing. Coronary abnormalities were identified in 71% of cases who had coronary magnetic resonance angiography. CONCLUSION: Stress perfusion cardiovascular magnetic resonance is a useful and accurate tool for investigation of myocardial ischaemia in an adult congenital heart disease population with suspected non-atherosclerotic coronary abnormalities.


Assuntos
Teste de Esforço , Cardiopatias Congênitas/diagnóstico , Hospitais Gerais , Imagem Cinética por Ressonância Magnética/métodos , Isquemia Miocárdica/diagnóstico , Imagem de Perfusão/métodos , Vasodilatadores , Adulto , Diagnóstico Diferencial , Feminino , Seguimentos , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/fisiopatologia , Humanos , Infusões Intravenosas , Masculino , Isquemia Miocárdica/etiologia , Isquemia Miocárdica/fisiopatologia , Ontário , Reprodutibilidade dos Testes , Estudos Retrospectivos , Vasodilatadores/administração & dosagem
11.
Acta Diabetol ; 61(1): 91-97, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37691025

RESUMO

AIMS: Type 2 diabetes mellitus (T2DM) increases the risk of major cardiovascular events. In SAVOR-TIMI53 trial, the excess heart failure (HF) hospitalization among patients with T2DM in the saxagliptin group remains poorly understood. Our aim was to evaluate left ventricular (LV) diastolic function after 6 months of saxagliptin treatment using cardiac magnetic resonance imaging (CMR) in patients with T2DM. METHODS: In this prospective study, 16 T2DM patients without HF were prescribed saxagliptin as part of routine guideline-directed management. CMR performed at baseline and 6 months after initiation of saxagliptin treatment were evaluated in a blinded fashion. We assessed LV diastolic function by measuring LV peak filling rate with correction for end-diastolic volume (PFR/LVEDV), time to peak filling rate with correction for cardiac cycle (TPF/RR), and early diastolic strain rate parameters [global longitudinal diastolic strain rate (GLSR-E), global circumferential diastolic strain rate (GCSR-E)] by feature tracking (FT-CMR). RESULTS: Among the 16 patients (mean age of 59.9, 69% males, mean hemoglobin A1c 8.3%, mean left ventricular ejection fraction 57%), mean PFR was 314 ± 108 ml/s at baseline and did not change over 6 months (- 2.7, 95% CI - 35.6, 30.2, p = 0.86). There were also no significant changes in other diastolic parameters including PFR/EDV, TPF, TPF/RR, and GLSR-E and GCSR-E (all p > 0.50). CONCLUSION: In T2DM patients without HF receiving saxagliptin over 6 months, there were no significant subclinical changes in LV diastolic function as assessed by CMR.


Assuntos
Adamantano/análogos & derivados , Diabetes Mellitus Tipo 2 , Dipeptídeos , Insuficiência Cardíaca , Disfunção Ventricular Esquerda , Masculino , Humanos , Pessoa de Meia-Idade , Feminino , Função Ventricular Esquerda , Volume Sistólico , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/tratamento farmacológico , Estudos Prospectivos , Imageamento por Ressonância Magnética , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/tratamento farmacológico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/tratamento farmacológico , Disfunção Ventricular Esquerda/etiologia
12.
Int J Cardiol ; 403: 131892, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38382853

RESUMO

BACKGROUND: Cardiac amyloidosis is increasingly recognized as a significant contributor to cardiovascular morbidity and mortality. With the emergence of novel therapies, there is a growing interest in prognostication of patients with cardiac amyloidosis using cardiac magnetic resonance imaging (CMR). In this systematic review and meta-analysis, we aimed to examine the prognostic significance of myocardial native T1 and T2, and extracellular volume (ECV). METHODS: Observational cohort studies or single arms of clinical trials were eligible. MEDLINE, EMBASE and CENTRAL were systematically searched from their respective dates of inception to January 2023. No exclusions were made based on date of publication, study outcomes, or study language. The study populations composed of adult patients (≥18 years old) with amyloid cardiomyopathy. All studies included the use of CMR with and without intravenous gadolinium contrast administration to assess myocardial native T1 mapping, T2 mapping, and ECV in association with the pre-specified primary outcome of all-cause mortality. Data were extracted from eligible primary studies by two independent reviewers and pooled via the inverse variance method using random effects models for meta-analysis. RESULTS: A total of 3852 citations were reviewed. A final nine studies including a total of 955 patients (mean age 65 ± 10 years old, 32% female, mean left ventricular ejection fraction (LVEF) 59 ± 12% and 24% had NYHA class III or IV symptoms) with cardiac amyloidosis [light chain amyloidosis (AL) 50%, transthyretin amyloidosis (ATTR) 49%, other 1%] were eligible for inclusion and suitable for data extraction. All included studies were single centered (seven with 1.5 T MRI scanners, two with 3.0 T MRI scanners) and non-randomized in design, with follow-up spanning from 8 to 64 months (median follow-up = 25 months); 320 patients died during follow-up, rendering a weighted mortality rate of 33% across studies. Compared with patients with AL amyloid, patients with ATTR amyloid had significantly higher mean left ventricular mass index (LVMi) (102 ± 34 g/m2 vs 127 ± 37 g/m2, p = 0.02). N-terminal pro-brain natriuretic peptide (NT-proBNP), troponin T levels, mean native T1 values, ECV and T2 values did not differ between patients with ATTR amyloid and AL amyloid (all p > 0.25). Overall, the hazard ratios for mortality were 1.33 (95% CI = [1.10, 1.60]; p = 0.003; I2 = 29%) for every 60 ms higher T1 time, 1.16 (95% CI = [1.09, 1.23], p < 0.0001; I2 = 76%) for every 3% higher ECV, and 5.23 (95% CI = [2.27, 12.02]; p < 0.0001; I2 = 0%) for myocardial-to-skeletal T2 ratio below the mean (vs above the mean). CONCLUSION: Higher native T1 time and ECV, and lower myocardial to skeletal T2 ratio, on CMR are associated with worse mortality in patients with cardiac amyloidosis. Therefore, tissue mapping using CMR may offer a useful non-invasive technique to monitor disease progression and determine prognosis in patients with cardiac amyloidosis.

13.
AJR Am J Roentgenol ; 200(1): 66-73, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23255743

RESUMO

OBJECTIVE: This article reviews the role of coronary calcium quantification in symptomatic patients and the pros and cons of acquiring an unenhanced coronary calcium scan in every patient with suspected coronary artery disease referred for coronary CT angiography. CONCLUSION: The acquisition of a coronary calcium scan in every symptomatic patient referred for coronary CT angiography requires a case-by-case approach.


Assuntos
Calcinose/diagnóstico por imagem , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Estenose Coronária/diagnóstico por imagem , Humanos , Prognóstico
14.
Can Assoc Radiol J ; 64(3): 213-9, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22579337

RESUMO

OBJECTIVE: The left ventricle (LV) is routinely assessed with cardiac magnetic resonance imaging (MRI) by using short-axis orientation; it remains unclear whether the right ventricle (RV) can also be adequately assessed in this orientation or whether dedicated axial orientation is required. We used phase-contrast (PC) flow measurements in the main pulmonary artery (MPA) and the ascending aorta (Aorta) as nonvolumetric standard of reference and compared RV and LV volumes in short-axis and axial orientations. METHODS: A retrospective analysis identified 30 patients with cardiac MRI data sets. Patients underwent MRI (1.5 T or 3 T), with retrospectively gated cine steady-state free-precession in axial and short-axis orientations. PC flow analyses of MPA and Aorta were used as the reference measure of RV and LV output. RESULTS: There was a high linear correlation between MPA-PC flow and RV-stroke volume (SV) short axis (r = 0.9) and RV-SV axial (r = 0.9). Bland-Altman analysis revealed a mean offset of 1.4 mL for RV axial and -2.3 mL for RV-short-axis vs MPA-PC flow. There was a high linear correlation between Aorta-PC flow and LV-SV short-axis (r = 0.9) and LV-SV axial (r = 0.9). Bland-Altman analysis revealed a mean offset of 4.8 m for LV short axis and 7.0 mL for LV axial vs Aorta-PC flow. There was no significant difference (P = .6) between short-axis-LV SV and short-axis-RV SV. CONCLUSION: No significant impact of the slice acquisition orientation for determination of RV and LV stroke volumes was found. Therefore, cardiac magnetic resonance workflow does not need to be extended by an axial data set for patients without complex cardiac disease for assessment of biventricular function and volumes.


Assuntos
Aorta/fisiopatologia , Cardiopatias/diagnóstico , Cardiopatias/fisiopatologia , Ventrículos do Coração/fisiopatologia , Imagem Cinética por Ressonância Magnética/métodos , Artéria Pulmonar/fisiopatologia , Adulto , Idoso , Cardiopatias/patologia , Ventrículos do Coração/patologia , Humanos , Processamento de Imagem Assistida por Computador/métodos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Volume Sistólico , Função Ventricular Esquerda , Função Ventricular Direita , Adulto Jovem
15.
Ann Biomed Eng ; 51(7): 1588-1601, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36871052

RESUMO

Coronary artery bypass graft surgery is a common intervention for coronary artery disease; however, it suffers from graft failure, and the underlying mechanisms are not fully understood. To better understand the relation between graft hemodynamics and surgical outcomes, we performed computational fluid dynamics simulations with deformable vessel walls in 10 study participants (24 bypass grafts) based on CT and 4D flow MRI one month after surgery to quantify lumen diameter, wall shear stress (WSS), and related hemodynamic measures. A second CT acquisition was performed one year after surgery to quantify lumen remodeling. Compared to venous grafts, left internal mammary artery grafts experienced lower abnormal WSS (< 1 Pa) area one month after surgery (13.8 vs. 70.1%, p = 0.001) and less inward lumen remodeling one year after surgery (- 2.4% vs. - 16.1%, p = 0.027). Abnormal WSS area one month post surgery correlated with percent change in graft lumen diameter one year post surgery (p = 0.030). This study shows for the first time prospectively a correlation between abnormal WSS area one month post surgery and graft lumen remodeling 1 year post surgery, suggesting that shear-related mechanisms may play a role in post-operative graft remodeling and might help explain differences in failure rates between arterial and venous grafts.


Assuntos
Ponte de Artéria Coronária , Doença da Artéria Coronariana , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Hemodinâmica , Artérias , Diagnóstico por Imagem
16.
Radiol Artif Intell ; 5(3): e230001, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37293344

RESUMO

Supplemental material is available for this article. Keywords: CT, Pulmonary Arteries, Embolism/Thrombosis, Feature Detection © RSNA, 2023.

17.
Radiol Cardiothorac Imaging ; 5(3): e210247, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37404790

RESUMO

Purpose: To compare the predictive value of different myocardial scar quantification thresholds using cardiac MRI for appropriate implantable cardioverter defibrillator (ICD) shock and mortality. Materials and Methods: In this retrospective, two-center observational cohort study, patients with ischemic or nonischemic cardiomyopathy underwent cardiac MRI prior to ICD implantation. Late gadolinium enhancement (LGE) was first determined visually and then quantified by blinded cardiac MRI readers using different SDs above the mean signal of normal myocardium, full-width half-maximum, and manual thresholding. The intermediate signal "gray zone" was calculated as the differences between different SDs. Results: Among 374 consecutive eligible patients (mean age, 61 years ± 13 [SD]; mean left ventricular ejection fraction, 32% ± 14; secondary prevention, 62.7%), those with LGE had a higher rate of appropriate ICD shock or death than those without (37.5% vs 26.6%, log-rank P = .04) over a median follow-up of 61 months. In multivariable analysis, none of the thresholds for quantifying scar was a significant predictor of mortality or appropriate ICD shock, while the extent of gray zone was an independent predictor (adjusted hazard ratio per 1 g = 1.025; 95% CI: 1.008, 1.043; P = .005) regardless of the presence or absence of ischemic heart disease (P interaction = .57). Model discrimination was highest for the model incorporating the gray zone (between 2 SD and 4 SD). Conclusion: Presence of LGE was associated with a higher rate of appropriate ICD shock or death. Although none of the scar quantification techniques predicted outcomes, the gray zone both in infarct and nonischemic scar was an independent predictor and may refine risk stratification.Keywords: MRI, Scar Quantification, Implantable Cardioverter Defibrillator, Sudden Cardiac Death Supplemental material is available for this article. © RSNA, 2023.

18.
J Cardiovasc Magn Reson ; 14: 69, 2012 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-23043729

RESUMO

BACKGROUND: For the primary prevention of sudden cardiac death, guidelines provide left ventricular ejection fraction (EF) criteria for implantable cardioverter defibrillator (ICD) placement without specifying the technique by which it should be measured. We sought to investigate the potential impact of performing cardiovascular magnetic resonance (CMR) for EF on ICD eligibility. METHODS: The study population consisted of patients being considered for ICD implantation who were referred for EF assessment by CMR. Patients who underwent CMR within 30 days of echocardiography were included. Echocardiographic EF was determined by Simpson's biplane method and CMR EF was measured by Simpson's summation of discs method. RESULTS: Fifty-two patients (age 62±15 years, 81% male) had a mean EF of 38 ± 14% by echocardiography and 35 ± 14% by CMR. CMR had greater reproducibility than echocardiography for both intra-observer (ICC, 0.98 vs 0.94) and inter-observer comparisons (ICC 0.99 vs 0.93). The limits of agreement comparing CMR and echocardiographic EF were - 16 to +10 percentage points. CMR resulted in 11 of 52 (21%) and 5 of 52 (10%) of patients being reclassified regarding ICD eligibility at the EF thresholds of 35 and 30% respectively. Among patients with an echocardiographic EF of between 25 and 40%, 9 of 22 (41%) were reclassified by CMR at either the 35 or 30% threshold. Echocardiography identified only 1 of the 6 patients with left ventricular thrombus noted incidentally on CMR. CONCLUSIONS: CMR resulted in 21% of patients being reclassified regarding ICD eligibility when strict EF criteria were used. In addition, CMR detected unexpected left ventricular thrombus in almost 10% of patients. Our findings suggest that the use of CMR for EF assessment may have a substantial impact on management in patients being considered for ICD implantation.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Imageamento por Ressonância Magnética , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/terapia , Função Ventricular Esquerda , Idoso , Morte Súbita Cardíaca/etiologia , Ecocardiografia , Definição da Elegibilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Ontário , Seleção de Pacientes , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Trombose/complicações , Trombose/diagnóstico , Trombose/fisiopatologia , Trombose/terapia , Disfunção Ventricular Esquerda/complicações , Disfunção Ventricular Esquerda/fisiopatologia
19.
Ann Biomed Eng ; 50(12): 1882-1894, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35881267

RESUMO

Although coronary artery bypass graft (CABG) surgery is a well-established intervention, graft failure can occur, and the underlying mechanisms remain incompletely understood. The purpose of this prospective study is to utilize computational fluid dynamics (CFD) to investigate how graft hemodynamics one month post surgery may vary among graft types, which have different long-term patency rates. Twenty-four grafts from 10 participants (64.6 ± 8.5 years, 9 men) were scanned with coronary CT angiography and 4D flow MRI one month after CABG surgery. Grafts included 10 left internal mammary arteries (LIMA), 3 radial arteries (RA), and 11 saphenous vein grafts (SVG). Image-guided CFD was used to quantify blood flow rate and wall area exposed to abnormal wall shear stress (WSS). Arterial grafts had a lower abnormal WSS area than venous grafts (17.9% vs. 70.1%; p = 0.001), and a similar trend was observed for LIMA vs. SVG (13.8% vs. 70.1%; p = 0.001). Abnormal WSS area correlated positively to lumen diameter (p < 0.001) and negatively to flow rate (p = 0.001). This CFD study is the first of its kind to prospectively reveal differences in abnormal WSS area 1 month post surgery among CABG types, suggesting that WSS may influence the differential long-term graft failure rates observed among these groups.


Assuntos
Ponte de Artéria Coronária , Artéria Torácica Interna , Masculino , Humanos , Estudos Prospectivos , Veias , Angiografia Coronária , Artéria Torácica Interna/diagnóstico por imagem , Artéria Torácica Interna/cirurgia , Veia Safena/diagnóstico por imagem , Resultado do Tratamento
20.
Cancer Imaging ; 22(1): 51, 2022 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-36114585

RESUMO

BACKGROUND: To evaluate computed tomography (CT) patterns of post-SBRT lung injury in lung cancer and identify time points of serial CT changes. MATERIALS AND METHODS: One hundred eighty-three tumors in 170 patients were evaluated on sequential CTs within 29 months (median). Frequencies of post-SBRT CT patterns and time points of initiation and duration were assessed. Duration of increase of primary lesion or surrounding injury without evidence of local recurrence and time to stabilization or local recurrence were evaluated. RESULTS: Post-SBRT CT patterns could overlap in the same patient and were nodule-like pattern (69%), consolidation with ground glass opacity (GGO) (41%), modified conventional pattern (39%), peribronchial/patchy consolidation (42%), patchy GGO (24%), diffuse consolidation (16%), "orbit sign" (21%), mass-like pattern (19%), scar-like pattern (15%) and diffuse GGO (3%). Patchy GGO started at 4 months post-SBRT. Peribronchial/patchy consolidation and consolidation with GGO started at 4 and 5 months respectively. Diffuse consolidation, diffuse GGO and orbit sign started at 5, 6 and 8 months respectively. Mass-like, modified conventional and scar-like pattern started at 8, 12 and 12 months respectively. Primary lesion (n = 11) or surrounding injury (n = 85) increased up to 13 months. Primary lesion (n = 119) or surrounding injury (n = 115) started to decrease at 4 and 9 months respectively. Time to stabilization was 20 months. The most common CT pattern at stabilization was modified conventional pattern (49%), scar-like pattern (23%) and mass-like pattern (12%). Local recurrence (n = 15) occurred at a median time of 18 months. CONCLUSION: Different CT patterns of lung injury post-SBRT appear in predictable time points and have variable but predictable duration. Familiarity with these patterns and timeframes of appearance helps differentiate them from local recurrence.


Assuntos
Lesão Pulmonar , Neoplasias Pulmonares , Radiocirurgia , Cicatriz/patologia , Humanos , Neoplasias Pulmonares/patologia , Radiocirurgia/efeitos adversos , Radiocirurgia/métodos , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA