Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
Biosens Bioelectron ; 23(1): 51-9, 2007 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-17462876

RESUMO

A sensitive and rapid electrochemical microchip fabricated by assembling a surface-functionalized poly(dimethylsiloxane) (PDMS) microchannel with an interdigitated array (IDA) gold electrode was developed for the detection of human cardiac troponin I (cTnI) in the early diagnosis of acute myocardial infarction. Anti-cTnI was immobilized onto the internal surface of the PDMS channel on which protein G layer had been generated by silanization. To reduce electrode fouling, a PDMS channel was assembled with an IDA chip after surface treatment. The detection experiments were performed with successive injection of cTnI, alkaline phosphatase (AP)-labeled anti-cTnI, and p-aminophenylphosphate. Then, cyclic voltammograms were obtained by the oxidation peak current proportionally to the concentration of enzymatic product, p-aminophenol. The optimal packing density of anti-cTnI on the surface of the PDMS channel was determined at the anti-cTnI concentration of 30 microg/ml for the highest electrochemical signal. These demonstrate that the proper orientation and best packing density of antibody as well as no electrode fouling contributed to the low detection limit (148 pg/ml) of cTnI within 8 min.


Assuntos
Análise Química do Sangue/instrumentação , Dimetilpolisiloxanos/química , Eletroquímica/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Nylons/química , Análise Serial de Proteínas/instrumentação , Troponina I/sangue , Análise Química do Sangue/métodos , Eletroquímica/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Técnicas Analíticas Microfluídicas/métodos , Análise Serial de Proteínas/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
J Cardiovasc Ultrasound ; 20(1): 49-51, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22509439

RESUMO

We present a case of persistent left superior vena cava, anomalous right pulmonary venous connection to the right-sided superior vena cava and sinus venosus atrial septal defect detected by computed tomography (CT) pulmonary angiography and echocardiography. These defects were surgically corrected using a double-patch technique. In fact, CT can provide anatomical information about a complex anomaly in the systemic and pulmonary vasculatures. Though modern imaging techniques are useful for detecting complex cardiovascular disease, careful echocardiographic examination should be performed to diagnose complex cardiac anomalies.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA