Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Orthop Traumatol ; 19(1): 14, 2018 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-30120638

RESUMO

BACKGROUND: The purpose of this study was to examine the gait pattern of total hip arthroplasty (THA) patients with a new short femoral stem at different speeds and inclinations. MATERIALS AND METHODS: A total of 40 unilateral THA patients were tested on an instrumented treadmill. They comprised two groups (shorter stemmed THA n = 20, longer stemmed THA n = 20), both which had the same surgical posterior approach. The shorter femoral stemmed patients were taken from an ongoing hip trial with minimum 12 months postop. The comparative longer THR group with similar disease and severity were taken from a gait database along with a demographically similar group of healthy controls (n = 35). All subjects were tested through their entire range of gait speeds and inclines with ground reaction forces collected. Body weight scaling was applied and a symmetry index to compare the implanted hip to the contralateral normal hip. An analysis of variance with significance set at α = 0.05 was used. RESULTS: The experimental groups were matched demographically and implant groups for patient reported outcome measures and radiological disease. Both THA groups walked slower than controls, but symmetry at all intervals for all groups were not significantly different. Push-off loading was less favourable for both the shorter and longer stemmed THR groups (p < 0.05) depending on speed. CONCLUSIONS: Irrespective of femoral stem length, symmetry for ground reaction forces for both THA groups were returned to a normal range when compared to controls. However individual implant performance showed inferior (p < 0.05) push-off forces and normalised step length in both THR groups when compared to controls. LEVEL OF EVIDENCE: III.


Assuntos
Artroplastia de Quadril/métodos , Fêmur/cirurgia , Marcha/fisiologia , Prótese de Quadril , Osteoartrite do Quadril/cirurgia , Velocidade de Caminhada/fisiologia , Suporte de Carga/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Teste de Esforço , Feminino , Fêmur/diagnóstico por imagem , Análise da Marcha , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/diagnóstico , Osteoartrite do Quadril/fisiopatologia , Período Pós-Operatório , Radiografia
2.
Healthc Q ; 17 Spec No: 28-32, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25562131

RESUMO

Cancer patients constitute one of the most complex, diverse and growing patient populations in Canada. Like other high-needs patient groups, cancer patients desire a more integrated approach to care delivery that spans organizational and professional boundaries. This article provides an overview of Cancer Care Ontario's experience in fostering a more integrated cancer system, and describes the organization's emerging focus on patient-centred models of integrated care through the whole cancer pathway, from prevention to end-of-life care and survivorship.


Assuntos
Oncologia/métodos , Assistência Centrada no Paciente/métodos , Prestação Integrada de Cuidados de Saúde/métodos , Prestação Integrada de Cuidados de Saúde/organização & administração , Humanos , Oncologia/organização & administração , Modelos Organizacionais , Neoplasias/prevenção & controle , Neoplasias/terapia , Serviço Hospitalar de Oncologia/organização & administração , Ontário , Cuidados Paliativos/métodos , Cuidados Paliativos/organização & administração , Assistência Centrada no Paciente/organização & administração
3.
Sci Rep ; 13(1): 17166, 2023 10 11.
Artigo em Inglês | MEDLINE | ID: mdl-37821511

RESUMO

Short stem, uncemented femoral implants for hip arthroplasty are bone conserving achieving stability through initial metaphyseal press-fit and biological fixation. This study aimed to evaluate the survivorship, mid-term function and health related quality of life outcomes in patients who have undergone total hip arthroplasty (THA) with a fully hydroxyapatite coated straight short stem femoral component with up to 5 years follow-up. 668 patients were recruited to a multicentre study investigating the performance of the cementless Furlong Evolution® stem for THA. 137 patients withdrew at various time points. The mean follow-up was 49 months. Clinical (Harris Hip Score (HHS), radiographic and patient-reported outcome measures-Oxford Hip Score (OHS) and EuroQol 5D (EQ-5D), were recorded pre-operatively and at 6 weeks, 6 months, 1 year, 3 year and 5 year follow ups. At 5-year follow-up, 12 patients underwent revision surgery, representing a cumulative revision rate of 1.8%. Median OHS, HHS and EQ5D scores improved significantly: OHS improved from a pre-operative median of 21 (IQR 14-26) to 47 (IQR 44-48) (p < 0.001). HHS improved from 52 (IQR 40-63) to 98 (IQR 92-100) (p < 0.001) and EQ5D improved from 70 (IQR 50-80) to 85 (IQR 75-95) (p < 0.001). This fully HA-coated straight short femoral stem implant demonstrated acceptable mid-term survivorship and delivered substantial improvements in function and quality of life after THA.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Seguimentos , Estudos Prospectivos , Durapatita , Qualidade de Vida , Desenho de Prótese , Reoperação , Resultado do Tratamento , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA