Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 98(2): 371-379, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-33876881

RESUMO

OBJECTIVES: To evaluate the safety and performance of the Hydra transcatheter aortic valve (THV) in the treatment of symptomatic severe aortic stenosis in patients at high or extreme surgical risk. BACKGROUND: The Hydra THV (Vascular Innovations Co. Ltd., Nonthaburi, Thailand) is a novel flexible repositionable self-expanding system with supra-annular bovine pericardial leaflets, available in three sizes, covering aortic annuli between 17 and 27 mm. METHODS: The GENESIS trial was a prospective, multi-center, single-arm, 6 month follow-up study conducted in India. The primary performance endpoint was device success defined as per VARC-II criteria at 30 days. The primary safety endpoint was all-cause mortality at 30 days. All endpoints were adjudicated by an independent clinical events committee. RESULTS: Forty high-risk patients (74.5 ± 6.7 years, 60% men; STS Score:5.6 ± 4.2%) were enrolled in 11 centres. Device success was achieved in 92.5%. The effective orifice area improved from 0.7 ± 0.2 to 2.3 ± 0.6 cm2 at 30 days and to 2.2 ± 0.7 cm2 at 6 months (p < .0001). Mean aortic valve gradient decreased from 53.5 ± 18.1 to 8.9 ± 4.9 mmHg at 30 days and to 7.6 ± 2.7 mmHg at 6 months (p < .0001). The rate of new permanent pacemaker implantation was 7.5% at 30 days, and no patient had more than mild paravalvular leak at 6 months. The 30 days and 6 month all-cause mortality was 10.0 and 17.5%, cardiovascular mortality 7.5 and 7.5%, device-related mortality 5.0 and 5.0%, respectively. No patients had stroke up to 6 months. CONCLUSIONS: The GENESIS trial demonstrated high efficacy of the self-expanding Hydra THV. The cardiovascular mortality rate of 7.5% may partly be explained by the inclusion of some centres with no or limited previous experience in transcatheter aortic valve implantation.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Hydra , Substituição da Valva Aórtica Transcateter , Animais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Bovinos , Feminino , Seguimentos , Humanos , Masculino , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Tailândia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
2.
Indian Heart J ; 75(5): 370-375, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37652199

RESUMO

OBJECTIVES: The presentation and outcomes of acute decompensated heart failure (ADHF) during COVID times (June 2020 to Dec 2020) were compared with the historical control during the same period in 2019. METHODS: Data of 4806 consecutive patients of acute HF admitted in 22 centres in the country were collected during this period. The admission patterns, aetiology, outcomes, prescription of guideline-directed medical therapy (GDMT) and interventions were analysed in this retrospective study. RESULTS: Admissions for acute heart failure during the pandemic period in 2020 decreased by 20% compared to the corresponding six-month period in 2019, with numbers dropping from 2675 to 2131. However, no difference in the epidemiology was seen. The mean age of presentation in 2019 was 61.75 (±13.7) years, and 59.97 (±14.6) years in 2020. There was a significant decrease in the mean age of presentation (p = 0.001). Also. the proportion of male patients decreased significantly from 68.67% to 65.84% (p = 0.037). The in-hospital mortality for acute heart failure did not differ significantly between 2019 and 2020 (4.19% and 4.,97%) respectively (p = 0.19). The proportion of patients with HFrEF did not change in 2020 compared to 2019 (76.82% vs 75.74%, respectively). The average duration of hospital stay was 6.5 days. CONCLUSION: The outcomes of ADHF patients admitted during the Covid pandemic did not differ significantly. The length of hospital stay remained the same. The study highlighted the sub-optimal use of GDMT, though slightly improving over the last few years.


Assuntos
COVID-19 , Insuficiência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Estudos Retrospectivos , Volume Sistólico , COVID-19/epidemiologia , Hospitalização
3.
JACC Cardiovasc Interv ; 15(1): 93-104, 2022 01 10.
Artigo em Inglês | MEDLINE | ID: mdl-34991828

RESUMO

OBJECTIVES: This study sought to evaluate the 30-day and 1-year safety and performance of the Hydra transcatheter aortic valve (THV) (in the treatment of symptomatic severe aortic stenosis in patients at high or extreme surgical risk. BACKGROUND: The Hydra THV is a novel repositionable self-expanding system with supra-annular bovine pericardial leaflets. METHODS: The Hydra CE study was a premarket, prospective, multicenter, single-arm study conducted across 18 study centers in Europe and Asia-Pacific countries. The primary endpoint was all-cause mortality at 30 days. All endpoints were adjudicated by an independent clinical events committee. RESULTS: A total of 157 patients (79.2 ± 7.1 years of age, 58.6% female; Society of Thoracic Surgeons score 4.7 ± 3.4%) were enrolled. Successful implantation was achieved in 94.3% cases. At 30 days, there were 11 (7.0%) deaths, including 9 (5.7%) cardiovascular deaths, of which 5 (3.2%) were device related. At 1 year, there were 23 (14.6%) deaths, including 13 (8.3%) cardiovascular deaths. At 30 days, there were significant improvement of effective orifice area (from 0.7 ± 0.2 cm2 to 1.9 ± 0.6 cm2) and mean aortic valve gradient (from 49.5 ± 18.5 mm Hg to 8.1 ± 3.7 mm Hg), which were sustained up to 1 year. Moderate or severe paravalvular leak was observed in 6.3% of patients at 30 days and 6.9% of patients at 1 year. The rate of new permanent pacemaker implantation was 11.7% at 30 days and 12.4% at 1 year. CONCLUSIONS: The Hydra CE study demonstrated that transcatheter aortic valve replacement with Hydra THV offered favorable efficacy at 1 year, providing large effective orifice area and low transvalvular gradient as well as acceptable complication rates with regard to new permanent pacemaker and paravalvular leak. (A Clinical Evaluation of the HYDRA Self Expanding Transcatheter Aortic Valve; NCT02434263).


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Animais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Bovinos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA