RESUMO
PURPOSE: To describe and evaluate relevant physical properties of the Swiss Liquid Jet Aesthesiometer for Corneal Sensitivity (SLACS) for ocular surface sensitivity measurement. METHODS: Characteristics of Liquid Jet (LJ) droplets (consisting of isotonic saline solution) were analysed: vertical and horizontal displacement and speed of LJ droplets were recorded with the aid of the High Speed Photron FASTCAM NOVA S6 camera (stimulus duration: 40 ms). Stimulus mass was assessed for 20 sets of 10 LJs with aid of a microbalance (pressure range of 100-1500 mbar). RESULTS: Because continuous flow LJ disintegrated into droplets in the lower pressure range (<700 mbar), pulsed stimuli were applied in order to obtain similar stimulus characteristics across the applied pressure range. For all measurements, very little variability was observed. Vertical and horizontal displacement did not exceed 0.13 mm in either direction. The mass per shot showed an unexpected cubic dependency on pressure. Up to approximately 700 mbar, LJ speed showed an almost linear relationship. For the pressure range of >700-1500 mbar, variability increased and speed decreased compared to the expected in a linear manner. However, this may be caused by the difficulty of identifying pattern changes of LJ droplets from one high speed image frame to the next with increasing stimulus speed, when determining LJ speed via pixel count. CONCLUSIONS: Swiss Liquid Jet Aesthesiometer for Corneal Sensitivity was shown to deliver fine droplets with a pulsed stimulus mode, in a repeatable manner with precise localisation to the ocular surface. Very little variability was observed in LJ speed and mass for the typical pressure range required for clinical sensitivity measurements.
Assuntos
Córnea , Etnicidade , Humanos , SuíçaRESUMO
BACKGROUND/AIM: Dental photographs are a valid means for documentation of dental luxation injuries. The aim of the study was to evaluate the utility of two photographs from different perspectives in the assessment of dental luxation injuries compared to one perspective only. MATERIALS AND METHODS: Photographs of simulated dental luxation injuries were shown to experts in dental traumatology and other dentists who had to estimate the displacement in the vertical and horizontal dimensions. The overall error of estimation as a result of both vertical displacement and horizontal displacement was calculated and statistically analyzed. RESULTS: The mean overall error of estimation was 0.43 mm and 0.75 mm for experts and dentists, respectively. If two (frontal and occlusal) perspectives were available, the overall error was lower than when only one perspective was available (p < .001). Experts had a lower overall error compared to dentists (p < .015). CONCLUSION: Two photographs from two perspectives allowed better interpretation of dental luxation injuries.
Assuntos
Luxações Articulares , Avulsão Dentária , Documentação , Humanos , Avulsão Dentária/terapiaRESUMO
PURPOSE: To evaluate if the animation "blink blink" increases blink rate and improves dry eye symptoms during prolonged computer use. METHODS: Study part A: Blink rate was recorded at baseline and during computer work of normal subjects without symptoms of dry eye. Half of the subjects used "blink blink," instructed to blink on animation appearance; the other half used a placebo version for 1 week during computer use. Thereafter, blink rate was recorded again with the use of "blink blink." Study part B: Blink rate was recorded during computer work with dry eye symptoms (modified Ocular Surface Disease Index > 15.0). Subjects used the test and placebo version of "blink blink" each for 1 week (1 week washout; crossover) and were instructed to blink twice on presentation of the animation. Blink rate and dry eye symptoms were assessed after each phase and compared with baseline. RESULTS: Study part A: Ten subjects participated (mean [± SD] age, 38.3 [± 16.0] years; 5 women). A greater increase in blink rate was observed in the test group (5.62 blinks/min for the test group and 0.96 blinks/min for the control group). Study part B: Twenty-four subjects participated (mean [± SD] age, 39.3 [± 19.1] years; 11 women). Dry eye symptoms improved during both phases (with test and placebo) to a statistically significant degree (each, p < 0.001). This difference was more marked with the test (-5.42 [± 2.86] points) compared with the placebo version (-1.79 [± 1.38] points). Blink rate increased with the program by 6.75 (± 3.80) blinks/min (p < 0.001), compared with 0.50 (± 2.83) blinks/min with placebo (p = 0.396). This difference between test and placebo was statistically significant (p < 0.001). Twenty of the 24 subjects could tolerate "blink blink" well during computer use. CONCLUSIONS: Blink rate and dry eye symptoms improved with "blink blink." The double blink prompted by the animation allowed a decrease in number of presentations and improved acceptance of "blink blink."
Assuntos
Piscadela/fisiologia , Computadores , Síndromes do Olho Seco/fisiopatologia , Análise e Desempenho de Tarefas , Adulto , Estudos Cross-Over , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Software , Adulto JovemRESUMO
CLINICAL RELEVANCE: Corneal sensitivity represents an important indicator for corneal health, its innervation and hence also for ocular disease. It is therefore of great interest from a clinical and research perspective to quantify ocular surface sensation. BACKGROUND: The aim of this prospective cross-sectional cohort study was to clinically test the within-day and day-to-day repeatability of the new Swiss Liquid Jet Aesthesiometer, employing small droplets of isotonic saline solution for repeatability, and correlate with the Cochet-Bonnet aesthesiometer in a cohort of participants of two different age groups, based on participant feedback (psychophysical method). METHODS: Participants were recruited from two equally, large age groups: group A (18-30 years) and group B (50-70 years). The inclusion criteria were healthy eyes, Ocular Surface Disease Index (OSDI) ≤ 13, and no contact lens wear. Mechanical corneal sensitivity threshold measurements with means of liquid jet and Cochet-Bonnet methods were carried out twice during two visits (a total of four measurements), with a stimulus temperature equal to or slightly above the ocular surface temperature. RESULTS: Ninety participants completed the study (n = 45 per age group, average age in group A: 24.2 ± 2.94 years, group B: 58.5 ± 5.71 years). The coefficient of repeatability for the liquid jet method was 2.56 dB within visits and 3.61 between visits. For the Cochet-Bonnet method, it was 2.27 dB within visits and 4.42 dB between visits (Bland Altman with bootstrap analysis). Moderate correlation was observed between the liquid jet and the Cochet-Bonnet method (r = 0.540, p < .001, robust linear regression). CONCLUSIONS: Swiss liquid jet aesthesiometry offers a new examiner independent method for corneal sensitivity measurement with acceptable repeatability and moderate correlation with the Cochet-Bonnet aesthesiometer. It offers a large stimulus pressure range of 100-1500 mbar and a precision of 1 mbar. Stimulus intensity can be tuned more precisely and much smaller sensitivity fluctuations may be potentially detected.
Assuntos
Córnea , Sensação , Humanos , Adulto Jovem , Adulto , Adolescente , Pessoa de Meia-Idade , Estudos Transversais , Estudos Prospectivos , Suíça , Córnea/inervaçãoRESUMO
PURPOSE: Dynamic contour tonometry (DCT) has been shown to measure the intraocular pressure (IOP) independently of corneal thickness. This study aimed to investigate if DCT remains accurate when the IOP measurement is taken over soft contact lenses (CLs) of different thicknesses and material characteristics. METHODS: This was a prospective clinical study that included 42 patients. Subject age was 22 to 59 years (26.5 ± 6.3 years). Intraocular pressure and ocular pulse amplitude (OPA) measurements were taken under topical anesthesia without CLs and over various daily disposable CLs with -0.50, +5.00, and -5.00 diopters (D) in hydrogel (Nelfilcon A) and in silicone hydrogel (Narafilcon A) materials. RESULTS: No statistically significant differences were found when comparing the IOP measurements obtained using either of the different CL powers of -0.50 or -5.00 D, irrespective of which CL material was being used. However, the difference of 0.62 mm Hg observed when the Nelfilcon A with a power of +5.00 D was used turned out to be highly statistically significant (p = 0.0002), whereas the Narafilcon A with the same power of +5.00 D, with a small difference of -0.16 mm Hg, was not. Regarding OPA measurements, no significant differences were found between measurements with and without CL neither for different materials nor for change in dioptrical power (F = 0, p = 1.000). CONCLUSIONS: This study showed good reliability of IOP and OPA measurements over CLs with varying thickness profiles and different soft materials when using the DCT. Only a small but statistically significant difference of 0.62 mm Hg was found for the IOP measurement with the hydrogel CL of +5.00 D compared with "no CL."
Assuntos
Lentes de Contato Hidrofílicas , Pressão Intraocular , Tonometria Ocular/métodos , Tonometria Ocular/normas , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Adulto JovemRESUMO
PURPOSE: The aim of this prospective cross-sectional cohort study was to test the effect of silicone hydrogel (SH) and rigid gas permeable (RGP) contact lens (CL) wear on corneal sensitivity, applying the new Swiss Liquid Jet Aesthesiometer for Corneal Sensitivity (SLACS) and the Cochet-Bonnet (CB) aesthesiometer, based on subject feedback (psychophysical method). METHODS: Participants were recruited for three equally large groups: Group A (SH CL), Group B (RGP CL) and Group C (non-CL wearers). Inclusion criteria were healthy eyes and OSDI ≤ 13. Corneal sensory thresholds were determined twice during two visits, with aid of SLACS and CB. RESULTS: 96 participants completed the study (n = 33 in groups A and C, n = 30 in group B); average age in group A: 27.42 ± 6.83 years, group B: 36.90 ± 9.68 years and group C: 26.06 ± 6.19 years. No statistically significant difference in corneal sensitivity was observed between the three groups for either method (p = 0.302 for SLACS, p = 0.266 for CB; Kruskal-Wallis rank sum test). Higher CSTs were obtained for males than for females in both CL groups with SLACS, and with CB only in the RGP CL group (p = 0.041 in Group A, p = 0.006 in Group B with SLACS; p = 0.041 in Group B with CB; bootstrap analysis with age correction and gender balancing). No correlation was observed between CL comfort and corneal sensitivity for neither method applied (for SLACS r = 0.097 and p = 0.51, for CB r = 0.17 and p = 0.15; robust linear mixed model). CONCLUSIONS: No difference in corneal sensitivity with CL compared to non-CL wear was noted in this study. However, lower levels of corneal sensitivity were observed in the male CL groups, warranting further investigation.
Assuntos
Lentes de Contato , Hidrogéis , Feminino , Humanos , Masculino , Adulto Jovem , Adulto , Silicones , Estudos Prospectivos , Estudos Transversais , CórneaRESUMO
PURPOSE: The aim of this prospective cross-sectional cohort study was to clinically test whether corneal sensation decreases with age, based on subject feedback (psychophysical method), and whether it correlates with general pain perception. METHODS: Subjects were recruited from 2 equally large age groups: group A (18-30 years) and group B (50-70 years; n = 45 per group). The inclusion criteria were healthy eyes, Ocular Surface Disease Index ≤13, and no contact lens wear. Corneal sensitivity threshold (CST) measurements were performed twice during each of the 2 visits, with the aid of the new Swiss liquid jet esthesiometer for corneal sensitivity (SLACS) and Cochet-Bonnet (CB) esthesiometer. A general pain sensitivity score was obtained from all participants. RESULTS: Ninety subjects completed the study (n = 45 per age group, average age in group A: 24.2 ± 2.94 years, group B: 58.5 ± 5.71 years). Statistically higher CSTs for age group B were only observed for SLACS (mean difference: 1.58 dB, P < 0.001). No correlation was observed between the pain score and the CSTs obtained with either esthesiometry method (r = 0.11, P = 0.25 for liquid jet and r=-0.076, P = 0.61 CB). CONCLUSIONS: A statistically significant decrease in corneal sensitivity was observed for the older age group with SLACS in this study, with CB however only a trend in the same direction was noted. General pain perception was not found to correlate with ocular surface sensation.
Assuntos
Córnea , Sensação , Humanos , Idoso , Adulto Jovem , Adulto , Adolescente , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Transversais , DorRESUMO
PURPOSE: To subjectively and objectively evaluate the efficacy and tolerability of preservative-free Ectoin ® Eye Spray - Colloidal (EES09) and Tears Again ® Eye Spray (TA) in subjects with mild-moderate dry eye disease (DED), and to compare efficacy of these two eye sprays with each other. METHODS: Thirty-six volunteers (average age 32.3 ± 16.1 years; 26 females) were successfully recruited for this prospective double-blind study with between-subject design and randomly divided into two groups (gender and age balanced): Group A received EES09 and Group B received TA during the treatment phase. Inclusioncriteria were a minimum age of 18 years, a score of 18.0 or higher on the OSDI questionnaire, and a non-invasive tear break up time (NIKBUT, Oculus Keratograph M5, Oculus, Germany) of no more than 10s in at least one eye. The objective variables NIKBUT, conjunctival redness, lipid layer and osmolarity (TearLab Cooperation, USA) were assessed at baseline, 10 min. after spray application and after a treatment phase of 10±3 days (3x applications daily). Symptoms, tolerance and handling were evaluated with the OSDI and VAS questionnaires. RESULTS: A statistically significant increase in NIKBUT and improvement in DED symptoms were obtained for the overall group (mean NIKBUT 7.7 ± 1.7s vs. 11.6 ± 4.6s, p<0.001; mean OSDI score: 36.1 ± 12.7 vs. 20. 7± 12.7, p<0.001) during course of treatment. No statistically significant effect was established for the variables lipid layer (p = 0.406), conjunctival redness (p = 0.766) and osmolarity (p = 0.378). No statistically significant differences were observed between the groups, for any variable. The noninferioritycriterion for EES09 towards TA could be shown for the scores of the dry eye symptoms via VAS questionnaire and the variable NIKBUT. CONCLUSIONS: A beneficial treatment effect was confirmed for both, symptoms of DED and the objective variable NIKBUT. Both eye sprays were rated favourably in view of perceived tolerability and handling of the spray bottle.
Assuntos
Diamino Aminoácidos , Síndromes do Olho Seco , Adolescente , Adulto , Síndromes do Olho Seco/diagnóstico , Síndromes do Olho Seco/tratamento farmacológico , Feminino , Humanos , Estudos Prospectivos , LágrimasRESUMO
BACKGROUND: The non-predictable variability in the capability of sensory adaptation to rigid gas permeable (RGP) contact lenses (CLs) represents a considerable challenge for CL practitioners and patients when choosing this CL type. This study explored if lid margin sensitivity and general pain sensitivity at baseline may help predict experienced subjective comfort of RGP CL wear. METHODS: For this prospective clinical cohort study, subjects filled in the Pain Sensitivity Questionnaire and lid margin sensitivity was measured at the lid wiper of the upper and lower lid at baseline, using the Cochet Bonnet aesthesiometer. RGP CL parameters were determined based on corneal topography, with additional use of fluorescein simulation. During the second visit, lid wiper sensitivity measurement was repeated and the RGP CLs were worn for 40 minutes. Upon removal of the CLs, lid wiper sensitivity measurement was repeated and spontaneous CL comfort was rated. RESULTS: Thirty-four subjects participated (mean age: 23.85 ± 5.39 years; 17 male). No correlation could be observed between the baseline lid margin sensitivity and spontaneous CL comfort (r = 0.013, p = 0.9417, upper lid; r = 0.016, p = 0.9277, lower lid). A decrease in lid margin sensitivity was obtained after CL wear (p = 0.0004, upper lid; p = 0.0001, lower lid). A good correlation was observed between Pain Sensitivity Questionnaire score and spontaneous CL comfort (r = 0.62, p = 0.0007). CONCLUSION: The results of this study suggest that lid margin sensitivity may not play an important role in spontaneous RGP CL comfort. The use of the Pain Sensitivity Questionnaire may well help select patients who are more likely to show good spontaneous tolerance of RGP CLs.
Assuntos
Lentes de Contato , Adulto , Estudos de Coortes , Humanos , Masculino , Dor , Percepção da Dor , Estudos Prospectivos , Adulto JovemRESUMO
Optometrists regularly use binocular measurements in patients with asthenopic complaints when performing close-up work. The focus of this work was therefore on the correlation of optometric parameters and objective fixation disparity (FD) measured by an eye tracker. In our investigation, 20 participants (6 male, 14 female) were subjected to a classical optometric procedure. Subsequently, these subjects read various sentences on a screen and eye movements were registered by using a RED500 eye tracker. The experiment was performed under two reading distance conditions. In order to be comparable with previous work, the present study was conducted under dark illumination conditions [12]. FD values were deduced from objective eye tracking data during reading. Data analysis was done using linear mixed-effects models. FD was found to depend on vergence facility (t=3.3, p=0.004). Subjects with a low vergence facility showed more eso fixation disparity than subjects with a normal vergence facility. If studies of binocular coordination using eye tracking methods are performed under dark illumination conditions, vergence facility is an important parameter and should be accounted for. Neglecting this parameter may mask other important parameters. Vergence facility in context of reading difficulties may be important.
RESUMO
Fixation disparity (FD) refers to a suboptimal condition of binocular vision. The oculomotor aspect of FD refers to a misadjustment in the vergence angle between the two visual axes that is measured in research with eye trackers (objective fixation disparity, oFD). The sensory aspect is psychophysically tested using dichoptic nonius lines (subjective fixation disparity, sFD). Some optometrists use nonius tests to determine the prisms for constant wear aiming to align the eyes. However, they do not (yet) use eye trackers. We investigate the effect of aligning prisms on oFD and sFD for 60 sec exposure duration of prisms determined with the clinically established Cross test in far distance vision. Without prisms, both types of FD were correlated with the aligning prism, while with prisms the FD was close to zero (these analyses included all base-in and base-out cases). The effect of base-in prisms on oFD was proportional to the amount of the aligning prism for the present 60 sec exposure, similar as for the 2- 5 sec exposure in Schmid et al. (2018). Thus, within 1 minute of prism exposure, no substantial vergence adaptation seems to occur in the present test conditions. Further studies may investigate intra-individual responses to different exposure times of aligning prisms in both prism directions.
RESUMO
PURPOSE: To explore the relationship between the degree of iris pigmentation and corneal sensitivity threshold (CST) on a variety of different ethnicities, using the air-jet noncontact corneal aesthesiometer and by applying a consistent method of subject iris pigmentation classification. METHODS: A total of 200 subjects (mean age 23.7 ± 3.1 years, 127 women) participated in this clinical cross-sectional study: 100 whites, 40 Asians, 40 Chinese, and 20 Afro-Caribbeans. CST was assessed within the central cornea using a noncontact corneal aesthesiometer, and the degree of iris pigmentation of each subject was noted according to the Seddon method using a set of graded photographs of iris pigmentation (grades 1-5). Inclusion criteria were absence of ocular disease including dry eye, no contact lens wear, and no use of artificial tears. Statistical testing between ethnicities was made by the pairwise t test with Holm adjustment, and a linear model was set up to analyze the effects of ethnicity and iris grade. RESULTS: A moderate trend for increasing CST with increasing iris pigmentation grade for all ethnicities was observed (R = 0.46; P < 0.0001), with CST changing from 0.66 ± 0.16 mbars for grade 1, 0.74 ± 0.18 mbars for grade 2, 0.86 ± 0.31 mbars for grade 3, 0.85 ± 0.32 mbars for grade 4, and 1.08 ± 0.40 mbars for grade 5. This correlation was stronger within the white group, representing the only ethnicity with all iris pigmentation grades (R = 0.50; P < 0.0001). CONCLUSIONS: There is a moderate relationship between corneal sensitivity and the degree of iris pigmentation, with sensitivity increasing as iris pigmentation decreases. This relationship is stronger within whites.
Assuntos
Córnea/fisiologia , Iris/fisiologia , Pigmentação/fisiologia , Adulto , Estudos Transversais , Etnicidade , Feminino , Humanos , Masculino , Limiar Sensorial/fisiologia , Adulto JovemRESUMO
In optometry of binocular vision, the question may arise whether prisms should be included in eyeglasses to compensate an oculomotor and/or sensory imbalance between the two eyes. The corresponding measures of objective and subjective fixation disparity may be reduced by the prisms, or the adaptability of the binocular vergence system may diminish effects of the prisms over time. This study investigates effects of wearing prisms constantly for about 5 weeks in daily life. Two groups of 12 participants received eyeglasses with prisms having either a base-in direction or a base-out direction with an amount up to 8 prism diopters. Prisms were prescribed based on clinical fixation disparity test plates at 6 m. Two dependent variables were used: (1) subjective fixation disparity was indicated by a perceived offset of dichoptic nonius lines that were superimposed on the fusion stimuli and (2) objective fixation disparity was measured with a video based eye tracker relative to monocular calibration. Stimuli were presented at 6 m and included either central or more peripheral fusion stimuli. Repeated measurements were made without the prisms and with the prisms after about 5 weeks of wearing these prisms. Objective and subjective fixation disparity were correlated, but the type of fusion stimulus and the direction of the required prism may play a role. The prisms did not reduce the fixation disparity to zero, but induced significant changes in fixation disparity with large effect sizes. Participants receiving base-out prisms showed hypothesized effects, which were concurrent in both types of fixation disparity. In participants receiving base-in prisms, the individual effects of subjective and objective effects were negatively correlated: the larger the subjective (sensory) effect, the smaller the objective (motor) effect. This response pattern was related to the vergence adaptability, i.e. the individual fusional vergence reserves.