1.
NMR Biomed ; 36(12): e5023, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37620002

RESUMO

A complementary safety assessment of the specific absorption rate (SAR) of the electromagnetic energy was performed in a prototype 8Tx/16Rx RF array for cardiac magnetic resonance imaging (MRI) at 7 T. The study aimed to address two critical aspects of 7-T SAR safety not always explicitly examined by coil vendors: (i) the influence of an RF-array position on a peak SAR value, and (ii) the risk of exceeding the permitted maximal SAR in the tissue surrounding conductive passive implants. The full-wave 3D electromagnetic simulations for the thorax with shifted array position and the whole-body volume in the presence of a dental retainer, an intrauterine contraceptive device (IUD), and a hip joint implant, were performed for two human voxel models. The effect of the array displacement on the SAR was simulated for seven array locations on the thorax shifted from the central position in different directions on 50 mm. The peak SAR values for both models were analyzed for the three phase-only transmit vectors optimized for B1 + homogeneity and transmit efficiency. Peak SAR values due to the shifts of the array position increase up to ≈50%. The worst-case peak SAR value for a dental retainer was found to be in the range of 10% of the maximal SAR in the tissue within the array's borders. For the IUD and artificial hip joint implants the effect was found to be negligible (peak SAR < 1% of the SAR within array borders). In addition to simulations for cardiac MRI, we performed a preliminary B1 + shimming and SAR-safety analysis for the same RF-array at various positions lower on the body trunk to assess a potential application in imaging abdominopelvic organs (prostate, kidney, and liver). The most promising target for an ad hoc alternative application of the array was found to be the prostate.


Assuntos
Imageamento por Ressonância Magnética , Tórax , Masculino , Humanos , Imagens de Fantasmas , Imageamento por Ressonância Magnética/métodos , Coração/diagnóstico por imagem , Próstata
2.
Magn Reson Med ; 71(2): 524-33, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23440917

RESUMO

PURPOSE: A novel highly accurate method for MR thermometry, effective at high field, is introduced and validated, which corrects for slow and fast field fluctuations by means of reference images. METHODS: An asymmetric spin-echo echo planar imaging sequence was made frequency-selective to water or a reference substance by controlling the slice-select gradient polarity and the duration of the excitation and refocusing radiofrequency pulses. Images were acquired pairwise, and the temperature-sensitive water images were corrected for field fluctuations using the reference images. In a phantom radiofrequency heating experiment, dissolved dimethyl sulfoxide was used as a reference substance. Temperature stability was tested in vivo on the human brain, referenced using subcutaneous scalp fat. Water and fat phase images were acquired only 50 ms apart. Bloch simulations validated the frequency selection accuracy. RESULTS: Asymmetric spin-echo imaging using a simple frequency selection method provides highly accurate referenced MR thermometry in phantoms and in vivo at 7 T. Effects of field fluctuations caused by field drift, breathing, and heart beat were corrected. The technique is highly robust against B1 inhomogeneities. CONCLUSION: Frequency selection using gradient-reversal can enable fast accurate referenced in vivo MR thermometry, assisting thermal characterization of radiofrequency coils and possibly in vivo SAR monitoring.


Assuntos
Imagem Ecoplanar/métodos , Termometria/métodos , Encéfalo/fisiologia , Humanos , Imagens de Fantasmas
3.
Front Hum Neurosci ; 7: 878, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24391571

RESUMO

The habenula is a small but important nucleus located next to the third ventricle in front of the pineal body. It helps to control the human reward system and is considered to play a key role in emotion, showing increased activation in major depressive disorders. Its dysfunction may underlie several neurological and psychiatric disorders. It is now possible to visualize the habenula and its anatomical subdivisions-medial habenula (MHB) and lateral habenula (LHB)-using MR techniques. The aim of this study was to further differentiate substructures within human lateral habenula (LHB) using ex vivo ultra-high field MR structural imaging, distinguishing between a medial part (m-LHB) and a lateral part (l-LHB). High resolution T1w images with 0.3-mm isotropic resolution and T2(*)w images with 60-micrometer isotropic resolution were acquired on a 7T MR scanner and quantitative maps of T1 and T2(*) were calculated. Cluster analysis of image intensity was performed using the Fuzzy and Noise Tolerant Adaptive Segmentation Method (FANTASM) tool. Ultra-high resolution structural MRI of ex vivo brain tissue at 7T provided sufficient SNR and contrast to discriminate the medial and lateral habenular nuclei. Heterogeneity was observed in the lateral habenula (LHB) nuclei, with clear distinctions between lateral and medial parts (m-LHB, l-LHB) and with the neighboring medial habenula (MHB). Clustering analysis based on the T1 and T2(*) maps strongly showed 4-6 clusters as subcomponents of lateral and medial habenula.