Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Knee Surg Sports Traumatol Arthrosc ; 31(9): 4027-4034, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37173573

RESUMO

INTRODUCTION: The rationale for the use of mini-implants for partial resurfacing in the treatment of femoral chondral and osteochondral lesions is still under debate. The evidence supporting best practise guidelines is based on studies with low-level evidence. A consensus group of experts was convened to collaboratively advance towards consensus opinions regarding the best available evidence. The purpose of this article is to report the resulting consensus statements. METHODS: Twenty-five experts participated in a process based on the Delphi method of achieving consensus. Questions and statements were drafted via an online survey of two rounds, for initial agreement and comments on the proposed statements. An in-person meeting between the panellists was organised during the 2022 ESSKA congress to further discuss and debate each of the statements. A final agreement was made via a final online survey a few days later. The strength of consensus was characterised as: consensus, 51-74% agreement; strong consensus, 75-99% agreement; unanimous, 100% agreement. RESULTS: Statements were developed in the fields of patient assessment and indications, surgical considerations and postoperative care. Between the 25 statements that were discussed by this working group, 18 achieved unanimous, whilst 7 strong consensus. CONCLUSION: The consensus statements, derived from experts in the field, represent guidelines to assist clinicians in decision-making for the appropriate use of mini-implants for partial resurfacing in the treatment of femoral chondral and osteochondral lesions. LEVEL OF EVIDENCE: Level V.


Assuntos
Traumatismos do Tornozelo , Cartilagem Articular , Humanos , Traumatismos do Tornozelo/cirurgia , Cartilagem Articular/cirurgia , Extremidade Inferior/cirurgia , Artroplastia/métodos , Fêmur/cirurgia
2.
Knee Surg Sports Traumatol Arthrosc ; 29(9): 2899-2910, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33025052

RESUMO

PURPOSE: Surgical treatment options for the management of focal chondral and osteochondral lesions in the knee include biological solutions and focal metal implants. A treatment gap exists for patients with lesions not suitable for arthroplasty or biologic repair or who have failed prior cartilage repair surgery. This study reports on the early clinical and functional outcomes in patients undergoing treatment with an individualised mini-metal implant for an isolated focal chondral defect in the knee. METHODS: Open-label, multicentre, non-randomised, non-comparative retrospective observational analysis of prospectively collected clinical data in a consecutive series of 80 patients undergoing knee reconstruction with the Episealer® implant. Knee injury and Osteoarthritis Outcome Score (KOOS) and VAS scores, were recorded preoperatively and at 3 months, 1 year, and 2 years postoperatively. RESULTS: Seventy-five patients were evaluated at a minimum 24 months following implantation. Two patients had undergone revision (2.5%), 1 declined participation, and 2 had not completed the full data requirements, leaving 75 of the 80 with complete data for analysis. All 5 KOOS domain mean scores were significantly improved at 1 and 2 years (p < 0.001-0.002). Mean preoperative aggregated KOOS4 of 35 (95% CI 33.5-37.5) improved to 57 (95% CI 54.5-60.2) and 59 (95% CI 55.7-61.6) at 12 and 24 months respectively (p < 0.05). Mean VAS score improved from 63 (95% CI 56.0-68.1) preoperatively to 32 (95% CI 24.4-38.3) at 24 months. The improvement exceeded the minimal clinically important difference (MCID) and this improvement was maintained over time. Location of defect and history of previous cartilage repair did not significantly affect the outcome (p > 0.05). CONCLUSION: The study suggests that at 2 years, Episealer® implants are safe with a low failure rate of 2.5% and result in clinically significant improvement. Individualised mini-metal implants with appropriate accurate guides for implantation appear to have a place in the management of focal femoral chondral and osteochondral defects in the knee. LEVEL OF EVIDENCE: IV.


Assuntos
Doenças das Cartilagens , Cartilagem Articular , Doenças das Cartilagens/cirurgia , Cartilagem Articular/cirurgia , Seguimentos , Humanos , Articulação do Joelho/cirurgia , Diferença Mínima Clinicamente Importante , Estudos Retrospectivos
3.
Unfallchirurg ; 124(10): 832-838, 2021 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-33331976

RESUMO

BACKGROUND: The treatment of patella fractures is technically demanding. Although the radiological results are mostly satisfactory, this often does not correspond to the subjective assessment of the patients. The classical treatment with tension band wiring with K­wires has several complications. Fixed-angle plate osteosynthesis seems to be biomechanically advantageous. OBJECTIVE: Who is treating patella fractures in Germany? What is the current standard of treatment? Have modern forms of osteosynthesis become established? What are the most important complications? MATERIAL AND METHODS: The members of the German Society for Orthopedics and Trauma Surgery and the German Knee Society were asked to participate in an online survey. RESULTS: A total of 511 completed questionnaires were evaluated. Most of the respondents are specialized in trauma surgery (51.5%), have many years of professional experience and work in trauma centers. Of the surgeons 50% treat ≤5 patella fractures annually. In almost 40% of the cases preoperative imaging is supplemented by computed tomography. The classical tension band wiring with K­wires is still the preferred form of osteosynthesis for all types of fractures (transverse fractures 52%, comminuted fractures 40%). In the case of comminuted fractures 30% of the surgeons choose fixed-angle plate osteosynthesis. If the inferior pole is involved a McLaughlin cerclage is used for additional protection in 60% of the cases. DISCUSSION: The standard of care for patella fractures in Germany largely corresponds to the updated S2e guidelines. Tension band wiring is still the treatment of choice. Further (long-term) clinical studies are needed to verify the advantages of fixed-angle plates.


Assuntos
Fraturas Ósseas , Fraturas Cominutivas , Parafusos Ósseos , Fios Ortopédicos , Fixação Interna de Fraturas , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Alemanha , Humanos , Patela/diagnóstico por imagem , Patela/cirurgia
4.
Knee Surg Sports Traumatol Arthrosc ; 26(12): 3582-3592, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29858655

RESUMO

PURPOSE: Dynamic intraligamentary stabilization (DIS) is a primary repair technique for acute anterior cruciate ligament (ACL) tears. For internal bracing of the sutured ACL, a metal spring with 8 mm maximum length change is preloaded with 60-80 N and fixed to a high-strength polyethylene braid. The bulky tibial hardware results in bone loss and may cause local discomfort with the necessity of hardware removal. The technique has been previously investigated biomechanically; however, the amount of spring shortening during movement of the knee joint is unknown. Spring shortening is a crucial measure, because it defines the necessary dimensions of the spring and, therefore, the overall size of the implant. METHODS: Seven Thiel-fixated human cadaveric knee joints were subjected to passive range of motion (flexion/extension, internal/external rotation in 90° flexion, and varus/valgus stress in 0° and 20° flexion) and stability tests (Lachman/KT-1000 testing in 0°, 15°, 30°, 60°, and 90° flexion) in the ACL-intact, ACL-transected, and DIS-repaired state. Kinematic data of femur, tibia, and implant spring were recorded with an optical measurement system (Optotrak) and the positions of the bone tunnels were assessed by computed tomography. Length change of bone tunnel distance as a surrogate for spring shortening was then computed from kinematic data. Tunnel positioning in a circular zone with r = 5 mm was simulated to account for surgical precision and its influence on length change was assessed. RESULTS: Over all range of motion and stability tests, spring shortening was highest (5.0 ± 0.2 mm) during varus stress in 0° knee flexion. During flexion/extension, spring shortening was always highest in full extension (3.8 ± 0.3 mm) for all specimens and all simulations of bone tunnels. Tunnel distance shortening was highest (0.15 mm/°) for posterior femoral and posterior tibial tunnel positioning and lowest (0.03 mm/°) for anterior femoral and anterior tibial tunnel positioning. CONCLUSION: During passive flexion/extension, the highest spring shortening was consistently measured in full extension with a continuous decrease towards flexion. If preloading of the spring is performed in extension, the spring can be downsized to incorporate a maximum length change of 5 mm resulting in a smaller implant with less bone sacrifice and, therefore, improved conditions in case of revision surgery.


Assuntos
Reconstrução do Ligamento Cruzado Anterior/instrumentação , Reconstrução do Ligamento Cruzado Anterior/métodos , Fenômenos Biomecânicos/fisiologia , Articulação do Joelho/fisiologia , Idoso , Idoso de 80 Anos ou mais , Lesões do Ligamento Cruzado Anterior/cirurgia , Cadáver , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Amplitude de Movimento Articular/fisiologia
5.
Knee Surg Sports Traumatol Arthrosc ; 26(2): 374-380, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28674740

RESUMO

PURPOSE: Dynamic intraligamentary stabilization (DIS) has been introduced as a new technique to repair the torn anterior cruciate ligament (ACL) and to restore knee joint kinematics after an acute ACL tear. Aim of the present study was to compare the early post-operative activity, restoration of gait pattern and functional results after DIS in comparison with primary ACL reconstruction (ACLR) for acute ACL tears. It was hypothesized that functional results, post-operative activity and changes in gait pattern after DIS are comparable to those after ACLR. METHODS: Sixty patients with acute ACL tears were included in this study and underwent either DIS or ACLR with an anatomic semitendinosus autograft in a randomized manner. Patients were equipped with an accelerometric step counter for the first 6 weeks after surgery in order to monitor their early post-operative activity. 3D gait analysis was performed at 6 weeks and 6 months after surgery. Temporal-spatial, kinematic and kinetic parameters were extracted and averaged for each subject. Functional results were recorded at 6 weeks, 6 months and 12 months after surgery using the Tegner activity scale, International Knee Documentation Committee score and Lysholm score. RESULTS: Patients who underwent DIS showed an increased early post-operative activity with significant differences at week 2 and 3 (p = 0.0241 and 0.0220). No significant differences between groups were found for knee kinematic and kinetic parameters or the functional scores at any time of the follow-up. Furthermore, the difference in anterior tibial translation was not significantly different between the two groups (n.s.). CONCLUSION: Early functional results and changes in gait pattern after DIS are comparable to those of primary ACLR. Therefore, ACL repair may be an alternative to ACLR in this cohort of patients. LEVEL OF EVIDENCE: I.


Assuntos
Lesões do Ligamento Cruzado Anterior/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos , Marcha/fisiologia , Articulação do Joelho/fisiopatologia , Adolescente , Adulto , Lesões do Ligamento Cruzado Anterior/fisiopatologia , Fenômenos Biomecânicos , Feminino , Seguimentos , Humanos , Articulação do Joelho/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento , Adulto Jovem
6.
Knee Surg Sports Traumatol Arthrosc ; 25(4): 1184-1190, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26239862

RESUMO

PURPOSE: Dynamic intraligamentary stabilization (DIS) has been introduced for the repair of acute anterior cruciate ligament (ACL) tears as an alternative to delayed reconstruction. The aim of the present study was to compare knee joint kinematics after DIS to those of the ACL-intact and ACL-deficient knee under simulated Lachman/KT-1000 and pivot-shift tests. We hypothesized that DIS provides knee joint kinematics equivalent to an intact ACL. METHODS: With the use of a robotic knee simulator, knee kinematics were determined in simulated Lachman/KT-1000 and pivot-shift tests at 0°, 15°, 30°, 60°, and 90° of flexion in eight cadaveric knees under the following conditions: (1) intact ACL, (2) ACL deficiency, (3) DIS with a preload of 60 N, and (4) DIS with a preload of 80 N. Statistical analyses were performed using two-factor repeated-measures analysis of variance. The significance level was set at a p value of <0.05. RESULTS: After DIS with a preload of either 60 N or 80 N, the anterior translation was significantly reduced in the simulated Lachman/KT-1000 and pivot-shift tests when compared to the ACL-deficient knee (p < 0.05). No significant differences were observed between the DIS reconstruction with a preload of 80 N and the intact ACL with regard to anterior laxity in either test. However, DIS with a preload of only 60 N was not able to restore knee joint kinematics to that of an intact knee in all degrees of flexion. CONCLUSION: DIS with a preload of 80 N restores knee joint kinematics comparable to that of an ACL-intact knee and is therefore capable of providing knee joint stability during ACL healing. DIS therefore provides a new technique for primary ACL repair with superior biomechanical properties in comparison with other techniques that have been described previously, although further clinical studies are required to determine its usefulness in clinical settings.


Assuntos
Reconstrução do Ligamento Cruzado Anterior/métodos , Articulação do Joelho/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos/fisiologia , Cadáver , Humanos , Instabilidade Articular/fisiopatologia , Instabilidade Articular/cirurgia , Articulação do Joelho/cirurgia , Pessoa de Meia-Idade , Exame Físico/métodos
7.
Arch Orthop Trauma Surg ; 137(12): 1677-1683, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28914349

RESUMO

INTRODUCTION: Complications after internal fixation of proximal humerus fracture are common and may require surgical revision. Reverse total shoulder arthroplasty (RTSA) is frequently performed in such cases. The aim of the present study was to evaluate the functional results and complications after RTSA for the treatment of type I fracture sequelae after internal fixation of proximal humerus fractures. MATERIALS AND METHODS: 26 patients (18 female, 8 male) underwent surgical revision of type I fracture sequelae of the proximal humerus after locking plate (n = 22) or intramedullary nail (n = 4) fixation. The mean age of the patients at the time of the revision was 75 years (range 65-89). After a mean follow-up of 36 months (range 18-58), clinical examination was performed and the age- and gender-related Constant-Murley Score (CMS) and the Oxford Shoulder Score (OSS) were obtained from all patients and compared to the pre-revision values. RESULTS: The mean age- and gender-related CMS of the affected shoulder increased from 44% (range 17-65) to 73% (range 44-97). This difference was statistically significant (p < 0.001). The CMS of the unaffected shoulder was 93% (range 72-98). This relates to a ratio in the CMS of 78% between the affected and the contralateral shoulder. The mean OSS was 28 points (range 12-54) for the operated shoulder and 43 points (range 34-48) for the unaffected side, resulting in 66% ratio. Again, the OSS improved significantly when compared with the preoperative values (p < 0.001). A total of five complications including two periprosthetic fractures were observed and required surgical revision. CONCLUSION: Satisfying results can be obtained with RTSA as a salvage procedure for type I fracture sequelae after previous internal fixation of proximal humerus fractures.


Assuntos
Artroplastia do Ombro/métodos , Fixação Interna de Fraturas/efeitos adversos , Complicações Pós-Operatórias/cirurgia , Reoperação , Fraturas do Ombro/cirurgia , Idoso , Idoso de 80 Anos ou mais , Pinos Ortopédicos , Placas Ósseas , Feminino , Humanos , Úmero/cirurgia , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
8.
Arch Orthop Trauma Surg ; 137(12): 1693-1698, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28929365

RESUMO

OBJECTIVES: The surgical treatment of comminuted fractures of the distal humerus remains a challenging problem. The aim of the present study was to compare the clinical outcomes of primary external fixation with second-staged open reduction and internal fixation (ORIF) and initial definitive internal fixation in surgically treated patients with comminuted distal humerus fractures. DESIGN: Retrospective comparative study. SETTING: Level one trauma center. PATIENTS: A total of 24 patients (median age 52 years; range 14-84 years) were included: 15 patients were treated with initial definitive internal fixation with pre-contoured locking compression plates (group A), and 9 patients underwent surgical treatment with primary external fixation and second-staged ORIF (group B). Only patients with C3 fractures according to the AO classification were included in the study. MAIN OUTCOME MEASUREMENT: Disability of the Arm, Shoulder and Hand (DASH) and Mayo Elbow Performance Score (MEPS). INTERVENTION: External fixation internal fixation with locking plates. RESULTS: The median follow-up was 37 months for both groups. There was a significantly higher median elbow extension deficit in group B (39°) compared to group A (17°) (p = 0.048). The mean DASH score in group A was 14 and 12.5 in group B. MEPS showed that more patients in group A achieved excellent results; however, there was no significant difference compared to group B. CONCLUSIONS: Primary external fixation with second-staged ORIF demonstrated a higher complication rate and significantly greater loss of extension compared with initial definitive internal fixation. Thus, the use of primary external fixation in cases of comminuted distal humerus fractures appears to have a negative influence on the patient outcomes. LEVEL OF EVIDENCE: Therapeutic level III.


Assuntos
Fixadores Externos , Fixação Interna de Fraturas/métodos , Fraturas Cominutivas/cirurgia , Fraturas do Úmero/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Placas Ósseas , Articulação do Cotovelo/cirurgia , Fixadores Externos/efeitos adversos , Feminino , Seguimentos , Fixação Interna de Fraturas/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Redução Aberta , Complicações Pós-Operatórias , Reoperação , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
9.
Arthroscopy ; 32(6): 1065-71, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26775734

RESUMO

PURPOSE: To analyze the ultimate failure load, yield load, stiffness, and cyclic elongation of 4 different fixation techniques for posterior cruciate ligament avulsion fractures under cyclic loading and load-to-failure conditions. METHODS: In 40 porcine knees, a standardized bony avulsion of the posterior cruciate ligament was generated. The osseous avulsion was fixed by the following techniques through an open approach: (1) direct anterograde screw fixation (3.5 mm with washer), (2) retrograde screw fixation (3.5 mm with washer), (3) cortical suspension button fixation (with No. 2 braided suture), and (4) direct suture cerclage (with No. 2 braided suture). The constructs were cyclically loaded 500 times (10 to 100 N) to measure the maximum elongation. Subsequently, loading to failure was performed, and stiffness, yield load, and maximum load were measured. A 1-way analysis-of-variance test was performed with significance set at P < .05. RESULTS: Button fixation resulted in lower elongation (1.25 ± 0.27 mm) than anterograde screw fixation (2.17 ± 0.74 mm, P = .0058) and the cerclage technique (2.02 ± 0.24 mm, P = .0290). The cerclage technique showed a lower yield load (493.55 ± 88.86 N) than anterograde screw fixation (720.39 ± 139.0 N, P = .0012) and retrograde screw fixation (668.58 ± 147.59 N, P = .0145); it also had lower stiffness and maximum load values (51.2 ± 6.11 N/mm and 631.22 ± 101.22 N, respectively) than the anterograde screw fixation technique (65.6 ± 12.74 N/mm, P = .041, for stiffness and 817.5 ± 145.9 N, P = .008, for maximum load). None of the other results were significantly different (P > .05). CONCLUSIONS: The cortical suspension button and retrograde screw fixation techniques showed comparable structural properties to the direct screw fixation technique. The raw structural properties of suture cerclage still seem eligible enough to consider using this technique for fixation. CLINICAL RELEVANCE: In this in vitro model, all techniques appear to constitute a biomechanically stable alternative to traditional anterograde screw fixation. In contrast to anterograde screw fixation, these techniques can be performed minimally invasively.


Assuntos
Fratura Avulsão/cirurgia , Teste de Materiais , Dispositivos de Fixação Ortopédica , Ligamento Cruzado Posterior/cirurgia , Técnicas de Sutura , Animais , Fenômenos Biomecânicos/fisiologia , Fratura Avulsão/fisiopatologia , Modelos Animais , Ligamento Cruzado Posterior/lesões , Ligamento Cruzado Posterior/fisiopatologia , Suínos
10.
Arthroscopy ; 32(1): 78-89, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26372523

RESUMO

PURPOSE: To kinematically and biomechanically compare 4 different types of tibial tunnel management in single-stage anterior cruciate ligament (ACL) revision reconstruction with the control: primary ACL reconstruction using a robotic-based knee testing setup. METHODS: Porcine knees and flexor tendons were used. One hundred specimens were randomly assigned to 5 testing groups: (1) open tibial tunnel, (2) bone plug technique, (3) biodegradable interference screw, (4) dilatation technique, and (5) primary ACL reconstruction. A robotic/universal force-moment sensor testing system was used to simulate the KT-1000 (MEDmetric, San Diego, CA) and pivot-shift tests. Cyclic loading and load-to-failure testing were performed. RESULTS: Anterior tibial translation increased significantly with all of the techniques compared with the intact ACL (P < .05). In the simulated KT-1000 test, groups 2 and 3 achieved results equal to those of primary ACL reconstruction (P > .05). The open tunnel and dilated tunnel techniques showed significantly greater anterior tibial translation (P < .05). The results of the simulated pivot-shift test were in accordance with those of the KT-1000 test. No significant differences could be observed regarding stiffness or maximum load to failure. However, elongation was significantly lower in the primary ACL reconstruction group compared with groups 1 and 3 (P = .02 and P = .03, respectively). CONCLUSIONS: Filling an incomplete and incorrect tibial tunnel with a press-fit bone plug or a biodegradable interference screw in a standardized laboratory situation provided initial biomechanical properties and knee stability comparable with those of primary ACL reconstruction. In contrast, the dilatation technique or leaving the malplaced tunnel open did not restore knee kinematics adequately in this model. Backup extracortical fixation should be considered because the load to failure depends on the extracortical fixation when an undersized interference screw is used for aperture fixation. CLINICAL RELEVANCE: Our biomechanical results could help orthopaedic surgeons to optimize the results of primary ACL revision with incomplete, incorrect tunnel placement.


Assuntos
Reconstrução do Ligamento Cruzado Anterior/métodos , Ligamento Cruzado Anterior/cirurgia , Amplitude de Movimento Articular , Tíbia/cirurgia , Animais , Fenômenos Biomecânicos , Parafusos Ósseos , Articulação do Joelho/cirurgia , Reoperação , Robótica , Suínos , Tendões/cirurgia
11.
Int Orthop ; 40(8): 1717-1723, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26432575

RESUMO

PURPOSE: The aim of this study was to biomechanically assess patellar tendon repair techniques with additional cable wire or polydioxanone suture (PDS) cord augmentation in comparison with a suture-anchor repair technique. METHODS: Patellar tendon repair was performed in 60 specimens using a porcine bone model. Yield load, maximum load, stiffness and elongation of patellar tendon reconstructions with (1) cable wire augmentation, (2) PDS cord augmentation or (3) suture anchor repair were evaluated using a cyclic loading and load-to-failure test setup. RESULTS: In comparison with suture anchor repair, augmentation of the reconstruction with either cable wires or PDS cords provides significantly higher maximum loads (527 and 460 N vs. 301 N; p < 0.01 and p = 0,012, respectively) under load-to-failure testing and less elongation (8.81 mm ± 1.55 mm and 10.56 mm ± 3.1 mm vs. 18.38 mm ± 7.51 mm; p = 0.037 and p = 0.033, respectively) under cyclic loading conditions. CONCLUSION: Augmentation of a patellar tendon repair with either a cable wire or a PDS cord provides higher primary stability than suture anchor repair in patellar tendon ruptures. The study supports the use of additional augmentation of a tendon repair in the clinical setting in order to prevent loss of reduction and allow for early post-operative mobilisation.


Assuntos
Traumatismos do Joelho/cirurgia , Patela/cirurgia , Ligamento Patelar/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Animais , Fenômenos Biomecânicos , Deambulação Precoce , Humanos , Período Pós-Operatório , Âncoras de Sutura , Técnicas de Sutura , Suturas , Suínos , Traumatismos dos Tendões/cirurgia
12.
J Shoulder Elbow Surg ; 24(8): 1282-8, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25704209

RESUMO

BACKGROUND: A radiolucent carbon fiber-reinforced polyetheretherketone (CFR-PEEK) plate was recently introduced for fixation of proximal humerus fractures. Prospective clinical and radiographic results of patients treated with a CFR-PEEK plate are compared with those of patients treated with a conventional locking plate. METHODS: Twenty-nine patients (mean age, 66 years) were treated with a CFR-PEEK plate for a 3- or 4-part proximal humerus fracture. Patients were clinically and radiographically re-examined at 6 weeks, 6 months, 12 months, and 24 months with the Simple Shoulder Test, Constant-Murley score (CMS), and Oxford Shoulder Score (OSS) as well as with simple radiographs. In addition, results were compared with a matched group of patients treated with a conventional locking plate. RESULTS: At the final follow-up examination at 24 months, patients achieved a mean Simple Shoulder Test score of 58%, a mean CMS of 71.3 points (range, 44-97), and a mean OSS of 27.4 points (range, 8-45). Bone union was confirmed in all patients. Compared with patients treated with the conventional locking plate, patients treated with the CFR-PEEK plate achieved significantly better results with regard to the CMS and the OSS (P = .038 and .029, respectively). Furthermore, loss of reduction with subsequent varus deformity was less frequently observed in the CFR-PEEK plate group. CONCLUSION: Fixation of proximal humerus fractures with a CFR-PEEK plate provides satisfying clinical and radiographic results after 2 years of follow-up. The results are comparable to those achieved with conventional locking plates.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas/métodos , Úmero/cirurgia , Cetonas , Polietilenoglicóis , Fraturas do Ombro/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Benzofenonas , Feminino , Humanos , Úmero/diagnóstico por imagem , Úmero/lesões , Masculino , Pessoa de Meia-Idade , Polímeros , Estudos Prospectivos , Radiografia , Fraturas do Ombro/diagnóstico por imagem , Adulto Jovem
13.
Transfus Med Hemother ; 42(2): 83-9, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26019703

RESUMO

BACKGROUND: The aim of our single-centre retrospective study presented here is to further analyse the utilisation of allogeneic blood components within a 5-year observation period (2009-2013) in trauma surgery (15,457 patients) under the measures of an educational patient blood management (PBM) initiative. METHODS: After the implementation of the PBM initiative in January 2012, the Institute of Transfusion Medicine und Transplantation Immunology educates surgeons and nurses at the Department of Trauma Surgery to avoid unnecessary blood transfusions. A standardised reporting system was used to document the utilisation of blood components carefully for the most frequent diagnoses and surgical interventions in trauma surgery. These measures served as basis for the implementation of an interdisciplinary systematic exchange of information to foster decision-making processes in favour of patient blood management. RESULTS: Since January 2012, the proportion of patients who received a transfusion as well as the number of transfused red blood cell (RBC) (7.3%/6.4%; p = 0.02), fresh frozen plasma (FFP) (1.7%/1.3%; p < 0.05) and platelet (PLT) (1.0%/0.5%; p < 0.001) units were reduced as a result of our PBM initiative. However, among the transfused patients, the number of administered RBC, FFP and PLT units did not decrease significantly. Overall, patients who did not receive transfusions were younger than transfused patients (p = 0.001). The subgroup with the highest probability of blood transfusion administered included patients with intensive care and long-term ventilation (before/after implementation of PBM: RBC 81.5%/75.9%; FFP 33.3%/20.4%; PLT 24.1%/13.0%). Only a total of 60 patients of 531 patients suffering multiple traumas were massively transfused (before/after implementation of PBM: RBC 55.6%/49.8%; FFP 28.4%/20.4%; PLT 17.6%/8.9%). CONCLUSION: According to our educational PBM initiative, at least the proportion of trauma patients who received allogeneic blood transfusions could be reduced significantly. However, in case of blood transfusions, the total consumption of RBC, FFP and PLT units remained stable in both time periods. This phenomenon might indicate that the actual need of blood transfusions rather depends on the severity of trauma-related blood loss, the coagulopathy rates or the complexity of the surgical intervention which mainly determines the intra-operative blood loss. Taken together, educational training sessions and systematic reporting systems are suitable measures to avoid unnecessary allogeneic blood transfusions and to continuously improve their restrictive application.

14.
Acta Orthop Belg ; 80(1): 106-11, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24873093

RESUMO

Aim of the present study was to compare the clinical and radiographic outcome of tension band wiring and precontoured locking compression plate fixation in patients treated surgically for an isolated olecranon fractures type IIA according to the Mayo classification. Of 26 patients presenting with an isolated Mayo type IIA olecranon fracture, 13 underwent fixation with a precontoured locking compression plate (group A), 13 patients were treated with tension band wiring (group B). At a mean follow-up of 43 months, patients were clinically and radiographically re-examined using the DASH score, the Mayo Elbow Performance score (MEPS) and anteroposterior and lateral radiographs. The mean DASH score was 14 points in group A and 12.5 points in group B. Regarding the MEPS, 92% of the patients in group A achieved a good to excellent results in comparison to 77% in group B. No significant differences between the two groups could be detected regarding the clinical and radiographic outcome. Implant-related irritations requiring hardware removal occurred more frequently in group B (12 vs. 7). Procedure and implant related costs were significantly higher in group A. Tension band wiring is still a preferable surgical method to treat simple isolated olecranon fractures. The patient must be informed that in all likelihood implant removal will be required once the fracture has healed. Fixation with precontoured locking compression plates does not provide better functional and radiographic outcome but is more expensive than tension band wiring.


Assuntos
Placas Ósseas , Fios Ortopédicos , Olécrano/lesões , Fraturas da Ulna/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Olécrano/diagnóstico por imagem , Complicações Pós-Operatórias , Radiografia , Reoperação , Fraturas da Ulna/diagnóstico por imagem
15.
Eur J Trauma Emerg Surg ; 50(4): 1691-1699, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38568230

RESUMO

PURPOSE: The study aims to investigate the influence of patient- and fracture-specific factors on the occurrence of complications after osteosynthesis of patella fractures and to compare knee joint function, activity, and subjective pain levels after a regular postoperative course and after complications in the medium term. METHODS: This retrospective, multicenter cohort study examined patients who received surgery for patella fracture at level 1 trauma centers between 2013 and 2018. Patient demographics and fracture-specific variables were evaluated. Final follow-up assessments included patient-reported pain scores (NRS), subjective activity and knee function scores (Tegner Activity Scale, Lysholm score, IKDC score), complications, and revisions. RESULTS: A total of 243 patients with a mean follow-up of 63.4 ± 21.3 months were included. Among them, 66.9% of patients underwent tension band wiring (TBW), 19.0% received locking plate osteosynthesis (LPO), and 14.1% underwent screw osteosynthesis (SO). A total of 38 patients (15.6%) experienced complications (TBW: 16.7%; LPO: 15.2%; SO: 11.8%). Implant-related complications of atraumatic fragment dislocation and material insufficiency/dislocation, accounted for 50% of all complications, were significantly more common after TBW than LPO (p = 0.015). No patient-specific factor was identified as a general cause for increased complications. Overall, particularly following complications such as limited range of motion or traumatic refracture, functional knee scores were significantly lower and pain levels were significantly higher at the final follow-up when a complication occurred. Implant-related complications, however, achieved functional scores comparable to a regular postoperative course without complications after revision surgery. CONCLUSION: The present study demonstrated that implant-related complications occurred significantly more often after TBW compared to LPO. The complication rates were similar in all groups.


Assuntos
Fixação Interna de Fraturas , Fraturas Ósseas , Patela , Complicações Pós-Operatórias , Humanos , Fixação Interna de Fraturas/efeitos adversos , Masculino , Feminino , Estudos Retrospectivos , Patela/lesões , Patela/cirurgia , Complicações Pós-Operatórias/epidemiologia , Pessoa de Meia-Idade , Fraturas Ósseas/cirurgia , Adulto , Idoso , Placas Ósseas , Parafusos Ósseos , Fratura da Patela
16.
Arthroscopy ; 29(4): 766-73, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23395115

RESUMO

PURPOSE: To compare the structural properties of 5 different fixation strategies for a free tendon graft at the patella in medial patellofemoral ligament (MPFL) reconstruction under cyclic loading and load to failure testing. METHODS: We used porcine patella and flexor tendons. We tested the following fixation techniques: 3.5-mm titanium anchor, transosseous 1-mm braided polyester suture, interference screw fixation, medial bone bridge, and transpatellar tunnels. We preconditioned each graft between 5 and 20 Nm before cyclic loading with 100 Nm for 1,000 cycles was started, and then performed load to failure testing. We recorded maximum load, stiffness, and elongation. RESULTS: In the bone bridge group, 60% of all specimens failed during cyclic testing. Fixation by transosseous sutures showed significantly less stiffness compared with all other techniques (P < .05). The bone bridge technique showed significantly lower load to failure compared with all other techniques (P < .05). Differences between the other groups were not significant. CONCLUSIONS: Fixation of a free tendon graft by transosseous sutures provides similar load to failure and elongation but less stiffness compared with fixation by anchors, interference screws, or transverse tunnels. Load to failure for the bone bridge technique was significantly lower than that for all other techniques. Furthermore, this fixation technique had a lower load to failure than that of the native MPFL. CLINICAL RELEVANCE: Fixation of soft tissue grafts at the patella by 1-mm braided polyester suture provides adequate fixation strength without implants in the patella, which might cause soft tissue irritation. Further studies will have to show if the lesser stiffness of this technique causes problems in the clinical setting or if this laxity might even be an advantage because it makes this reconstruction more forgiving concerning overtensioning the graft. Significantly lower load to failure of the bone bridge technique should be considered in postoperative treatment.


Assuntos
Ligamentos Articulares/cirurgia , Patela/cirurgia , Articulação Patelofemoral/lesões , Articulação Patelofemoral/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Tendões/transplante , Animais , Fenômenos Biomecânicos , Ligamentos Articulares/lesões , Modelos Animais , Técnicas de Sutura , Suínos , Tendões/fisiopatologia
17.
Knee Surg Sports Traumatol Arthrosc ; 21(5): 1176-82, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-22552620

RESUMO

PURPOSE: To evaluate the biomechanical properties of a new coracoclavicular (CC) ligament reconstruction using a subcoracoidal flip button and a tendon graft compared to an augmented tendon loop and a synthetic coracoclavicular ligament reconstruction. METHODS: A porcine metatarsalia model was used to assess supero-inferior fixation strength of (1) a new technique using an augmented tendon graft and a subcoracoidal flip button in a lifting block fashion, (2) an augmented tendon loop around the coracoid base and (3) a synthetic coracoclavicular ligament augmentation technique. Cyclic loading from 20 to 70 N for 1,000 cycles was performed, followed by a load-to-failure protocol. RESULTS: All specimens of the three different groups survived the cyclic loading protocol. The maximum loads to failure under superior loading conditions were 760 ± 78 N for group 1, 702 ± 48 N for group 2 and 1117 ± 91 N for group 3. The synthetic coracoclavicular ligament augmentation technique revealed significantly higher maximum loads compared to the other groups (p < 0.001). The augmented tendon graft/flip button construct had higher maximum loads than the augmented tendon loop (n.s.). No significant differences were found for stiffness and elongation behaviour among the 3 tested groups. CONCLUSION: The results suggest that the described technique is an alternative option to reconstruct the CC ligaments in AC joint instability in a minimal-invasive technique. Under superior loading conditions, the biomechanical properties exhibited by this novel technique were comparable to those of the tendon loop around the coracoid base.


Assuntos
Articulação Acromioclavicular/lesões , Luxações Articulares/cirurgia , Ligamentos Articulares/cirurgia , Procedimentos de Cirurgia Plástica , Animais , Fenômenos Biomecânicos , Modelos Animais de Doenças , Ligamentos Articulares/fisiopatologia , Procedimentos Cirúrgicos Minimamente Invasivos , Suínos , Tendões/transplante
18.
J Exp Orthop ; 10(1): 92, 2023 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-37707660

RESUMO

PURPOSE: Focal chondral lesions of the femur are currently treated with biological repair or arthroplasty. However, some patients are not suitable for either one due to lesion size, age, or prior biological treatment attempts. While singular patient-specific focal mini metal implants already showed good results, the outcomes of bicompartmental implantation of these implants have not been discussed in the literature yet. This study aims to evaluate clinical outcomes of patients who underwent bicompartmental implantation of two patient-specific implants. METHODS: This prospective, non-randomized, non-comparative pilot study evaluates results up to two years after bicompartmental implantation of two implants (Episealer Implant, Episurf, Stockholm, Sweden). A damage report is compiled using a special MRI program and patient specific implants are manufactured, including 3D-printed surgical instruments to provide exact placement of the implant. The patients were assessed repeatedly using the Knee Injury and Osteoarthritis Outcome Score (KOOS) and Visual Analogue Scale (VAS) for pain during the follow-up. RESULTS: The scores were evaluated three, 12, and 24 months after surgery and showed good results. The median in both scores improved from 37.7 for the KOOS5 preoperatively to 69.1 after 24 months and from 69 for the VAS for pain preoperatively to 9 after 24 months. CONCLUSION: Overall, for the small study group presented, the early results are promising. With noticeable improvement in KOOS and VAS for pain after two years, patient specific implants appear to become relevant in future standardized treatment of femoral chondral lesions. Especially with bicompartmental implantation, full arthroplasty can be delayed even further. LEVEL OF EVIDENCE: IV.

19.
J Clin Med ; 12(6)2023 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-36983341

RESUMO

Purpose: Several suture techniques have been described in the past for direct ACL repair with poor healing capacity and a high re-rupture rate. Therefore, we investigated a refixation technique for acute primary proximal ACL repair. The purpose of this study is to compare the biomechanical properties of different suture configurations using a knotless anchor. Methods: In this study, 35 fresh-frozen porcine knees underwent proximal ACL refixation. First, in 10 porcine femora, the biomechanical properties of the knotless anchor, without the ligament attached, were tested. Then, three different suture configurations were evaluated to reattach the remaining ACL. Using a material testing machine, the structural properties were evaluated for cyclic loading followed by loading to failure. Results: The ultimate failure load of the knotless anchor was 198, 76 N ± 23, 4 N significantly higher than all of the tested ACL suture configurations. Comparing the different configurations, the modified Kessler-Bunnell suture showed significant superior ultimate failure load, with 81, 2 N ± 15, 6 N compared to the twofold and single sutures (50, 5 N ± 14 N and 37, 5 ± 3, 8 N). In cyclic loading, there was no significant difference noted for the different configurations in terms of stiffness and elongation. Conclusions: The results of this in vitro study show that when performing ACL suture using a knotless anchor, a modified Kessler-Bunnell suture provides superior biomechanical properties than a single and a twofold suture. Within this construct, no failure at the bone-anchor interface was seen. Clinical relevance: Since primary suture repair techniques of ACL tears have been abandoned because of inconsistent results, ACL reconstruction remains the gold standard of treating ACL tears. However, with the latest improvements in surgical techniques, instrumentation, hardware and imaging, primary ACL suture repair might be a treatment option for a select group of patients. By establishing an arthroscopic technique in which proximal ACL avulsion can be reattached, the original ACL can be preserved by using a knotless anchor and a threefold suture configuration. Nevertheless, this technique provides an inferior ultimate failure load compared to graft techniques, so a careful rehabilitation program must be followed if using this technique in vivo.

20.
Z Orthop Unfall ; 2023 Sep 06.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-37673084

RESUMO

Tibial plateau fractures are mostly complex and surgically demanding joint fractures, which require a comprehensive understanding of the fracture morphology, ligamentous and neurovascular injuries, as well as the diagnostic and therapeutic options for an optimal clinical outcome. Therefore, a standardised and structured approach is required. The success of the treatment of tibial plateau fractures relies on the interdisciplinary cooperation between surgical and conservative physicians in an outpatient and inpatient setting, physical therapists, patients and service providers (health insurance companies, statutory accident insurance, pension providers). On behalf of the German Society for Orthopaedics and Trauma Surgery (DGOU), the German Trauma Society (DGU) and the Society for Arthroscopy and Joint Surgery (AGA), under the leadership of the Fracture Committee of the German Knee Society (DKG), a guideline for tibial plateau fractures was created, which was developed in several voting rounds as part of a Delphi process. Based on the current literature, this guideline is intended to make clear recommendations and outline the most important treatment steps in diagnostics, therapy and follow-up treatment. Additionally, 25 statements were revised by the authors in several survey rounds using the Likert scale in order to reach a final consensus.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA