Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Ann Surg ; 276(5): e353-e360, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-35946824

RESUMO

OBJECTIVE: The aim was to assess the impact of operating room (OR) ventilation quality on surgical site infections (SSIs) using a novel ventilation index. BACKGROUND: Previous studies compared laminar air flow with conventional ventilation, thereby ignoring many parameters that influence air flow properties. METHODS: In this cohort study, we surveyed hospitals participating in the Swiss SSI surveillance and calculated a ventilation index for their ORs, with higher values reflecting less turbulent air displacement. For procedures captured between January 2017 and December 2019, we studied the association between ventilation index and SSI rates using linear regression (hospital-level analysis) and with the individual SSI risk using generalized linear mixed-effects models (patient-level analysis). RESULTS: We included 47 hospitals (182 ORs). Among the 163,740 included procedures, 6791 SSIs were identified. In hospital-level analyses, a 5-unit increase in the ventilation index was associated with lower SSI rates for knee and hip arthroplasty (-0.41 infections per 100 procedures, 95% confidence interval: -0.69 to -0.13), cardiac (-0.89, -1.91 to 0.12), and spine surgeries (-1.15, -2.56 to 0.26). Similarly, patient-level analyses showed a lower SSI risk with each 5-unit increase in ventilation index (adjusted odds ratio 0.71, confidence interval: 0.58-0.87 for knee and hip; 0.72, 0.49-1.06 for spine; 0.82, 0.69-0.98 for cardiac surgery). Higher index values were mainly associated with a lower risk for superficial and deep incisional SSIs. CONCLUSIONS: Better ventilation properties, assessed with our ventilation index, are associated with lower rates of superficial and deep incisional SSIs in orthopedic and cardiac procedures. OR ventilation quality appeared to be less relevant for other surgery types.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Humanos , Estudos de Coortes , Eletrólitos , Salas Cirúrgicas , Fatores de Risco , Infecção da Ferida Cirúrgica/epidemiologia , Infecção da Ferida Cirúrgica/prevenção & controle
2.
GMS Hyg Infect Control ; 14: Doc20, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-32047719

RESUMO

In recent years, there has been an ongoing discussion about the value of laminar airflow (LAF=low turbulence displacement ventilation) in the operating room for prevention of surgical site infections (SSI). Some publications, e.g., from the WHO, issued the demand to no longer build LAF ceilings in operating rooms. The present statement deals critically with this position and justifies the use of LAF ceilings in different ways: Many of the papers cited by the WHO and others for the case against LAF do not provide reliable data.The remaining studies which might be used for answering the question give quite different results, also in favor of LAF.The size of the LAF ceiling in many studies is not given or mostly too small in comparison to actual technical requirements.LAF in different countries can mean quite different techniques (e.g., the US in comparison to Germany) so that the results of studies that do not take this into account may not be comparable.LAF has positive effects in terms of reducing particulate and bacterial load, associated with increased airflow in the surgical working area. A reduction of carcinogenic substances in the air may also be assumed, which would increase workers' safety. Thus, this paper recommends building LAF ceilings in the future as well, depending on the operations intended. Further, this paper gives an overview of possible reasons for surgical site infections and highlights the importance of discipline in the operating theatre.

3.
GMS Hyg Infect Control ; 11: Doc03, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26958457

RESUMO

Since the publication of the first "Hospital Hygiene Guideline for the implementation and operation of air conditioning systems (HVAC systems) in hospitals" (http://www.krankenhaushygiene.de/informationen/fachinformationen/leitlinien/12) in 2002, it was necessary due to the increase in knowledge, new regulations, improved air-conditioning systems and advanced test methods to revise the guideline. Based on the description of the basic features of ventilation concepts, its hygienic test and the usage-based requirements for ventilation, the DGKH section "Ventilation and air conditioning technology" attempts to provide answers for the major air quality issues in the planning, design and the hygienically safe operation of HVAC systems in rooms of health care.

SELEÇÃO DE REFERÊNCIAS