Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
BMC Med Educ ; 24(1): 843, 2024 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-39107748

RESUMO

BACKGROUND: Point of care ultrasound (POCUS) education has grown significantly over the past two decades. Like most curricular items, POCUS education is siloed within individual graduate medical education (GME) programs. The purpose of this study was to evaluate the effectiveness of a shared GME POCUS curriculum between five GME programs at a single institution. METHODS: Post-graduate-year-1 (PGY-1) residents from emergency medicine (EM), family medicine (FM), internal medicine (IM), combined internal medicine-pediatrics (IM-Peds) and combined emergency medicine-pediatrics (EM-Peds) residency programs were enrolled in a core POCUS curriculum. The curriculum included eleven asynchronous online learning modules and ten hands-on training sessions proctored by sonographers and faculty physicians with POCUS expertise. Data was gathered about the curriculum's effectiveness including participation, pre- and post-curricular surveys, pre- and post-knowledge assessments, and an objective skills assessment. RESULTS: Of the 85 residents enrolled, 61 (72%) participated in the curriculum. Engagement varied between programs, with attendance at hands-on sessions varying the most (EM 100%, EM-Peds 100%, FM 40%, IM 22%, Med-Peds 11%). Pre- and post-knowledge assessment scores improved for all components of the curriculum. Participants felt significantly more confident with image acquisition, anatomy recognition, interpreting images and incorporating POCUS findings into clinical practice (p < 0.001) after completing the curriculum. CONCLUSION: In this shared GME POCUS curriculum, we found significant improvement in POCUS knowledge, attitudes, and psychomotor skills. This shared approach may be a viable way for other institutions to provide POCUS education broadly to their GME programs.


Assuntos
Competência Clínica , Currículo , Educação de Pós-Graduação em Medicina , Internato e Residência , Sistemas Automatizados de Assistência Junto ao Leito , Ultrassonografia , Humanos , Avaliação Educacional
2.
Inorg Chem ; 62(39): 15952-15962, 2023 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-37725578

RESUMO

A comprehensive field- and temperature-dependent examination of nuclear magnetic resonance paramagnetic relaxation enhancements (PREs) for the constitutive protons of [Co(Tpm)2][BF4]2 is presented. Data for an apically substituted derivative clearly establish that bis-Tpm complexes of Co(II) undergo Jahn-Teller dynamics about the molecular threefold axis. PREs from the parent Tpm complex were used to numerically extract the electron relaxation times (T1e). The Tpm complex showed field-dependent behavior, with an approximately 40% higher activation barrier than the related trispyrazolylborate (Tp) complex, based on fits to the T1e vs T, B0 data. Analysis of the field-dependent line widths revealed a surprisingly large contribution from susceptibility (Curie) relaxation (20-35% at the highest field), and a molecular radius (9.5 Å) that is consistent with a tightly associated counterion slowing rotation in solution. Density functional theory showed a shared vibration that is consistent with the Jahn-Teller and appears proportionately higher in energy in [Co(Tpm)2]2+. Complete active-space self-consistent field calculations support ascribing electron relaxation to enhanced mixing of the two Eg orbital sets that accompanies the tetragonal distortion and the differences in electron correlation times to the higher Jahn-Teller activation barrier in [Co(Tpm)2]2+.

3.
Inorg Chem ; 56(1): 618-626, 2017 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-27977149

RESUMO

Paramagnetic resonance studies (EPR, ESEEM, ENDOR, and NMR) of a series of cobalt(II) bis-trispyrazolylmethane tetrafluoroborates are presented. The complexes studied include the parent, unsubstituted ligand (Tpm), two pyrazole-substituted derivatives (4Me and 3,5-diMe), and tris(1-pyrazolyl)ethane (Tpe), which includes a methyl group on the apical carbon atom. NMR and ENDOR establish the magnitude of 1H hyperfine couplings, while ESEEM provides information on the coordinated 14N. The data show that the pyrazole 3-position is more electron rich in the Tpm analogues, that the geometry about the apical atom influences the magnetic resonance, and that apical atom geometry appears more fixed in Tpm than in Tp. NMR and ENDOR establish that the BF4- counterion remains associated in fluid solution. In the case of the Tpm3,5Me complex, it appears to associate in solution, in the same position it occupies in the X-ray structure.

4.
Sci Rep ; 8(1): 16972, 2018 11 19.
Artigo em Inglês | MEDLINE | ID: mdl-30451960

RESUMO

Patients with end stage renal disease (ESRD) suffer high mortality from arrhythmias linked to fibrosis, but are contraindicated to late gadolinium enhancement magnetic resonance imaging (MRI). We present a quantitative method for gadolinium-free cardiac fibrosis imaging using magnetization transfer (MT) weighted MRI, and probe correlations with widely used surrogate markers including cardiac structure and contractile function in patients with ESRD. In a sub-group of patients who returned for follow-up imaging after one year, we examine the correlation between changes in fibrosis and ventricular structure/function. Quantification of changes in MT revealed significantly greater fibrotic burden in patients with ESRD compared to a healthy age matched control cohort. Ventricular mechanics, including circumferential strain and diastolic strain rate were unchanged in patients with ESRD. No correlation was observed between fibrotic burden and concomitant measures of either circumferential or longitudinal strains or strain rates. However, among patients who returned for follow up examination a strong correlation existed between initial fibrotic burden and subsequent loss of contractile function. Gadolinium-free myocardial fibrosis imaging in patients with ESRD revealed a complex and longitudinal, not contemporary, association between fibrosis and ventricular contractile function.


Assuntos
Cardiopatias/diagnóstico por imagem , Falência Renal Crônica/diagnóstico por imagem , Adulto , Feminino , Fibrose/diagnóstico por imagem , Gadolínio , Cardiopatias/complicações , Cardiopatias/patologia , Humanos , Falência Renal Crônica/complicações , Falência Renal Crônica/patologia , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA