1.
Artif Organs ; 47(3): 574-581, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36305735

RESUMO

BACKGROUND: Invasive hemodynamic variables obtained from right heart catheterization have been used for risk-stratifying patients with advanced heart failure (HF). However, there is a paucity of data on the prognostic value of invasive hemodynamic variables in patients with left ventricular assist devices (LVAD). We hypothesized that cardiac power output (CPO), cardiac power efficiency (CPE), and left ventricular stroke work index (LVSWI) can serve as prognostic markers in patients with LVADs. METHODS: Baseline hemodynamic data from patients who had LVAD ramp studies at our institution from 4/2014 to 7/2018 were prospectively collected, from which advanced hemodynamic variables (CPO, CPE, and LVSWI) were retrospectively analyzed. Univariate and multivariable analyses were performed for hemocompatibility-related adverse events (HRAE), HF admissions, and mortality. RESULTS: Ninety-one participants (age 61 ± 11 years, 34% women, 40% Black or African American, and 38% ischemic cardiomyopathy) were analyzed. Low CPE was significantly associated with mortality (HR 2.42, 95% CI 1.02-5.74, p = 0.045) in univariate analysis and Kaplan-Meier analysis (p = 0.04). Low LVSWI was significantly associated with mortality (HR 2.13, 95% CI 1.09-4.17, p = 0.03) in univariate analysis and Kaplan-Meier analysis (p = 0.02). CPO was not associated with mortality. CPO, CPE, and LVSWI were not associated with HRAE or HF admissions. CONCLUSIONS: Advanced hemodynamic variables can serve as prognostic indicators for patients with LVADs. Low CPE and LVSWI are prognostic for higher mortality, but no variables were associated with HF admissions or HRAEs.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Masculino , Prognóstico , Coração Auxiliar/efeitos adversos , Estudos Retrospectivos , Hemodinâmica , Débito Cardíaco
2.
Heart Vessels ; 37(12): 1995-2001, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35794489

RESUMO

OBJECTIVES: The purpose of this study is to investigate the early and late outcomes of axillary intra-aortic balloon pump (IABP) implantation as a bridge to heart transplantation, comparing the grafted technique with the percutaneous technique. METHODS: Between July 2009 and January 2020, 163 patients underwent an axillary IABP insertion as a bridge to heart transplantation. Among them, 97 patients underwent axillary IABP implantation through a graft sutured onto the axillary artery (Group A) and 66 patients underwent percutaneously (Group B). Propensity matching identified 53 matched pairs for analysis (C-statistics 0.741). The primary outcomes of interest included IABP-related complications, success rate of a bridge to transplantation, in-hospital mortality, and late survival. RESULTS: In the propensity-score matched cohort, there were no significant differences in the baseline characteristics between the two groups. The operation time was significantly longer in Group A than in Group B (141.5 ± 38.3 min vs 42.7 ± 19.3 min, p < 0.01). The complication rates including stroke, re-exploration for bleeding, and aortic event were not significantly different between Group A and B. However, Group A required more transfusion and re-exploration for bleeding. The success rate of a bridge to transplantation was similar between Group A (47/53, 88.7%) and Group B (47/53, 88.7%). There were no significant differences in in-hospital mortality and late survival between two groups. CONCLUSION: In the propensity score matching analysis, there were not any significant differences between the two groups in IABP-related complications, in-hospital mortality, and late survival. The percutaneous technique provided a shorter operation time and less requirement of transfusion and re-exploration for bleeding compared to the grafted technique. The percutaneous technique might be favorable when feasible.


Assuntos
Transplante de Coração , Coração Auxiliar , Humanos , Pontuação de Propensão , Estudos Retrospectivos , Balão Intra-Aórtico/efeitos adversos , Resultado do Tratamento
3.
Heart Vessels ; 37(4): 647-653, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34585275

RESUMO

We sought to assess the impact of the aortic root geometry on developing de novo aortic insufficiency (AI) in patients undergoing left ventricular assist device (LVAD). In total, 114 patients underwent LVAD implantation between February 2016 and January 2020 were included in this study (HeartMate3 N = 68, HeartWare N = 46). Significant aortic insufficiency was defined as mild-to-moderate or greater in echocardiography. The cohort was divided into two groups; those who developed significant AI (Group AI: n = 13) and did not (Group non-AI: n = 101). The primary outcomes of interest included late survival and predictors for significant AI. The patients in Group AI were older than Group non-AI (62.6 ± 11.9 vs 51.3 ± 14.0 years, p < 0.01). The diameter of proximal ascending aorta in Group AI was larger than Group non-AI (31.0 ± 5.0 vs 27.4 ± 4.3 mm, p < 0.01). Aortic valve remained closed in 53.8% in Group AI and 36.6% in Group non-AI (p = 0.24). The late survival was not significantly different between the groups (67.1% vs 76.0% at 3 years, log rank = 0.97). The Cox hazard model showed that larger proximal ascending aortic diameter/BSA (HR 1.55, CI 1.19-2.04, p < 0.01) and not-opening aortic valve (HR 4.73, CI 1.43-16.9, p = 0.01) were independent risk factors for significant AI. The cutoff value of proximal ascending aortic diameter/BSA was 15.5 (area under curve: 0.770, sensitivity: 0.69, specificity: 0.79). Dilated proximal ascending aorta at the time of LVAD surgery and not-opening aortic valve during follow-up were associated with the incidence of de novo significant AI.


Assuntos
Insuficiência da Valva Aórtica , Coração Auxiliar , Aorta/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/epidemiologia , Insuficiência da Valva Aórtica/etiologia , Coração Auxiliar/efeitos adversos , Humanos , Incidência , Estudos Retrospectivos , Função Ventricular Esquerda
4.
Ann Vasc Surg ; 83: 42-52, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34995740

RESUMO

OBJECTIVE: Axillary Intra-aortic balloon pump (IABP) has been increasingly utilized for hemodynamic support in heart failure patients. Vascular complications associated with axillary IABP such as dissection or rupture are relatively rare but not negligible that could negatively affect clinical outcomes. We summarized our experiences. METHODS: This is a retrospective study reviewing of all patients receiving an axillary IABP between June 2016 and November 2020. A total of 199 patients underwent percutaneous axillary IABP placement. 6 patients (6/199, 3.0%) were complicated with arterial/aortic dissection or rupture during the procedures or the course of treatment. We described their clinical presentations and outcomes. RESULTS: Vascular complications included acute type A aortic dissection in 2 patients, descending aortic rupture in 1 patient, abdominal aortic rupture along with type B aortic dissection in 1 patient, and the localized left subclavian artery dissection in 2 patient. 2 type A aortic dissection cases were surgically treated: 1 with emergent left ventricle assist device and ascending aorta replacement, the other with emergent left ventricle assist device. Emergent endovascular treatment was successfully performed in 2 aortic rupture cases. The left subclavian artery dissection cases were managed medically. The postoperative/treatment course was uneventful in all patients. CONCLUSION: Percutaneous axillary IABP therapy can cause significant vascular complications. Early diagnosis and prompt treatment would be the key to improve the clinical outcomesv.


Assuntos
Dissecção Aórtica , Ruptura Aórtica , Coração Auxiliar , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/etiologia , Ruptura Aórtica/cirurgia , Coração Auxiliar/efeitos adversos , Humanos , Estudos Retrospectivos , Resultado do Tratamento
5.
Artif Organs ; 2022 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-36574590

RESUMO

PURPOSE: Tolvaptan, a selective vasopressin type-2 antagonist, has been shown to increase serum sodium (Na) and urine output in hyponatremic left ventricular assist device (LVAD) patients in retrospective studies. In this prospective randomized pilot study, we aimed to assess the efficacy of tolvaptan in this population. METHODS: We conducted a prospective, randomized, non-blinded pilot study of LVAD recipients with post-operative hyponatremia (Na < 135 mEq/L) (NCT05408104). Eligible participants were randomized to receive tolvaptan 15 mg daily in addition to usual care versus usual care alone. The primary outcome was a change in Na level and estimated glomerular filtration rate (eGFR), from the first post-operative day of hyponatremia (the day of randomization) to discharge. RESULTS: A total of 33 participants were enrolled, and 28 underwent randomization (median age 55 [IQR 50-62]), 21% women, 54% Black, 32% ischemic cardiomyopathy, median baseline Na 135 (IQR 134-138). Fifteen participants were randomized to tolvaptan (TLV) and 13 were randomized to usual care alone (No-TLV). Mean change in Na from randomization to discharge in the TLV group was 2.7 mEq/L (95%CI 0.7-4.7, p = 0.013) and 1.8 (95%CI 0.5-4.0, p = 0.11) in the No-TLV group, though baseline and final Na levels were similar between groups. The mean change in eGFR was 2.6 ml/min/1.73 m2 (95%CI 10.1-15.3, p = 0.59) in TLV versus 7.5 ml/min/1.73 m2 (95%CI 5.2-20.2, p = 0.15) in No-TLV. TLV participants had significantly more urine output than No-TLV patients during their first 24 h after randomization (3294 vs 2155 ml, p = 0.043). CONCLUSION: TLV significantly increases urine output, with nominal improvement in Na level, in hyponatremic post-operative LVAD patients without adversely impacting renal function.

6.
J Card Fail ; 27(10): 1045-1052, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34048919

RESUMO

BACKGROUND: Right heart catheterization for invasive hemodynamics has shown only modest correlation with clinical outcomes. We designed a novel hemodynamic variable that incorporates ventricular output and filling pressure. We anticipated that the aortic pulsatility index (API) would correlate with clinical outcomes in patients with heart failure. METHODS AND RESULTS: We retrospectively analyzed consecutive patients undergoing right heart catheterization with milrinone drug study at our institution (February 2013 to November 2019). The API was calculated as (systolic blood pressure - diastolic blood pressure)/pulmonary capillary wedge pressure. The primary outcome was freedom from advanced therapies, defined as the need for inotropes, temporary mechanical circulatory support, a left ventricular assist device, or orthotopic heart transplantation, or death at 30 days. A total of 224 patient encounters, age 57 years (48-66 years; 34% women; 31% ischemic cardiomyopathy) were included. In univariable analysis, lower baseline API was significantly associated with progression to advanced therapies or death at 30-days (odds ratio 0.43, 95% confidence interval 0.30-0.61; P < .001) compared with those on continued medical management. Receiver operator characteristic analysis specified an optimal cutpoint of 1.45 for API. A Kaplan-Meier analysis indicated an association of API with the primary outcome (79% for API ≥ 1.45 vs 48% for API < 1.45). In multivariable analysis, higher API was strongly associated with freedom from advanced therapies or death (odds ratio 0.38, 95% confidence interval 0.22-0.65, P ≤ .001), even when adjusted for baseline characteristics and routine right heart catheterization measurements. CONCLUSIONS: The API is a novel invasive hemodynamic measurement that is associated independently with freedom from advanced therapies or death at 30-day follow-up.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Pressão Propulsora Pulmonar , Estudos Retrospectivos
7.
Clin Transplant ; 35(4): e14242, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33539043

RESUMO

BACKGROUND: Capillary deposition of C4d is an important marker of antibody-mediated rejection (AMR) following heart transplantation (HT). There are two immunopathologic assay methods for detecting C4d: frozen-tissue immunofluorescence (IF) and paraffin immunohistochemistry (IHC). The clinical significance of discrepancy between the results of IF and IHC has not been understood. METHODS AND RESULTS: We reviewed 2187 biopsies from 142 HT recipients who had biopsies with assessment of both IF and IHC staining. Among them, 103 (73%) patients had negative IF and IHC C4d staining (Negative Group) and 32 (23%) patients had positive IF but negative IHC staining (Discordant Group). At the time of positive biopsy, 6 (19%) Discordant patients had graft dysfunction, compared to 5 (5%) Negative patients (p = .022). Cumulative incidence of cellular rejection at 1 year was comparable (31% vs. 29%, p = .46); however, cumulative incidence of AMR was significantly higher in the Discordant group (21% vs. 4%, p = .004). Overall 1-year survival was comparable (90% vs. 96%, p = .24); however, freedom from heart failure (HF) was significantly lower in the Discordant group (70% vs. 96%, p < .001). CONCLUSION: The Discordant group showed higher rates of graft dysfunction, AMR and HF admission than the Negative group.


Assuntos
Complemento C4b , Transplante de Coração , Biópsia , Imunofluorescência , Rejeição de Enxerto/diagnóstico , Rejeição de Enxerto/etiologia , Humanos , Imuno-Histoquímica , Fragmentos de Peptídeos , Coloração e Rotulagem
8.
J Artif Organs ; 24(4): 425-432, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33792816

RESUMO

Preoperative cardiopulmonary exercise testing (CPET) is well validated for prognostication before advanced surgical heart failure therapies, but its role in prognostication after LVAD surgery has never been studied. VE/VCO2 slope is an important component of CPET which has direct pathophysiologic links to right ventricular (RV) performance. We hypothesized that VE/VCO2 slope would prognosticate RV dysfunction after LVAD. All CPET studies from a single institution were collected between September 2009 and February 2019. Patients who ultimately underwent LVAD implantation were selectively analyzed. Peak VO2 and VE/VCO2 slope were measured for all patients. We evaluated their association with hemodynamic, echocardiographic and clinical markers of RV dysfunction as well mortality. Patients were stratified into those with a ventilatory class of III or greater. (VE/VCO2 slope of ≥ 36, n = 43) and those with a VE/VCO2 slope < 36 (n = 27). We compared the mortality between the 2 groups, as well as the hemodynamic, echocardiographic and clinical markers of RV dysfunction. 570 patients underwent CPET testing. 145 patients were ultimately referred to the advanced heart failure program and 70 patients later received LVAD implantation. Patients with VE/VCO2 slope of ≥ 36 had higher mortality (30.2% vs. 7.4%, p = 0.02) than patients with VE/VCO2 slope < 36 (n = 27). They also had a higher incidence of clinically important RVF (Acute severe 9.3% vs. 0%, Severe 32.6% vs 25.9%, p = 0.03). Patients with a VE/VCO2 slope ≥ 36 had a higher CVP than those with a lower VE/VCO2 slope (11.2 ± 6.1 vs. 6.0 ± 4.8 mmHg, p = 0.007), and were more likely to have a RA/PCWP ≥ 0.63 (65% vs. 19%, p = 0.008) and a PAPI ≤ 2 (57% vs. 13%, p = 0.008). In contrast, peak VO2 < 12 ml/kg/min was not associated with postoperative RV dysfunction or mortality. Elevated preoperative VE/VCO2 slope is a predictor of postoperative mortality, and is associated with postoperative clinical and hemodynamic markers of impaired RV performance.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Disfunção Ventricular Direita , Teste de Esforço , Insuficiência Cardíaca/diagnóstico , Humanos , Consumo de Oxigênio , Prognóstico
9.
J Card Fail ; 26(4): 360-367, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31935459

RESUMO

BACKGROUND: Characterization of right heart catheterization (RHC) waveforms provides diagnostic and clinical information in heart failure patients. We aimed to investigate the implication of RHC waveforms, specifically the y-descent, in patients with left ventricular assist device (LVAD). METHODS AND RESULTS: Patients underwent RHC and waveforms were quantified prior to and 6 months after LVAD implantation. The impact of a deep y-descent (>3 mmHg) on echocardiographic measures of right heart function and 1-year hemocompatibility-related adverse event rates were investigated. Eighty-nine patients (median 59 years old, 65 male) underwent RHC. RHC waveform showed unique changes following LVAD implantation, particularly an increase in the steepness of the y-descent. A post-LVAD deep y-descent was associated with reduced right ventricular function and enlarged right heart. Patients with post-LVAD deep y-descent had higher rates of gastrointestinal bleeding (0.866 vs 0.191 events/year) and stroke (0.199 vs 0 events/year) compared with those without (P< .05 for both). CONCLUSION: RHC waveforms characterized by deep y-descent on RHC waveform during LVAD support was associated with impaired right ventricular function and worse clinical outcomes.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Disfunção Ventricular Direita , Ecocardiografia , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Função Ventricular Direita
10.
J Card Fail ; 26(2): 128-135, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31442494

RESUMO

BACKGROUND: Historically, invasive hemodynamic guidance was not superior compared to clinical assessment in patients admitted with acute decompensated heart failure (ADHF). This study assessed the accuracy of clinical assessment vs invasive hemodynamics in patients with ADHF. METHODS AND RESULTS: We conducted a prospective cohort study of patients admitted with ADHF. Prior to right-heart catheterization (RHC), physicians categorically predicted right atrial pressure, pulmonary capillary wedge pressure, cardiac index and hemodynamic profile (wet/dry, warm/cold) based on physical examination and clinical data evaluation (warm = cardiac index > 2.2 L/min/m2; wet = pulmonary capillary wedge pressure > 18 mmHg). We collected 218 surveys (of 83 cardiology fellows, 55 attending cardiologists, 45 residents, 35 interns) evaluating 97 patients. Of those patients, 46% were receiving inotropes prior to RHC. The positive and negative predictive values of clinical assessment compared to RHC for the cold and wet subgroups were 74.7% and 50.4%. The accuracy of categorical prediction was 43.6% for right atrial pressure, 34.4% for pulmonary capillary wedge pressure and 49.1% for cardiac index, and accuracy did not differ by clinician (P > 0.05 for all). Interprovider agreement was 44.4%. Therapeutic changes following RHC occurred in 71.1% overall (P < 0.001). CONCLUSIONS: Clinical assessment of patients with advanced heart failure presenting with ADHF has low accuracy across all training levels, with exaggerated rates of misrecognition of the most high-risk patients.


Assuntos
Cateterismo Cardíaco/tendências , Tomada de Decisão Clínica , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Hemodinâmica/fisiologia , Médicos/normas , Idoso , Estudos de Coortes , Feminino , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Inquéritos e Questionários
11.
Artif Organs ; 44(4): 367-374, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31660619

RESUMO

The purpose of this study is to compare clinical outcomes of left ventricular assist device (LVAD) patients with device thrombosis who underwent device exchange (DE) or medical therapy (MT) alone. Consecutive patients undergoing LVAD implant between July 2008 and December 2017 were included. Device thrombosis was diagnosed with comprehensive assessments including ramp test, laboratory data, device parameters, and clinical presentations. First, MT was initiated in all patients. After MT, DE was considered if device thrombosis was refractory to initial MT, and it caused end-organ impairment and/or hemodynamic instability. Among 319 consecutive LVAD patients, 43 patients (13.5%) were diagnosed with device thrombosis. DE was performed in 28 patients (DE group); device explant was performed in 1 patient. MT was continued in 14 patients (MT group). In-hospital mortality was significantly lower in the DE group than the MT group (3.6% [1/28] vs. 28.6% [4/14], P = .0184). One-year survival was significantly better in the DE group (74.0% vs. 30.1%; log-rank = .001), and freedom from cerebrovascular accident (CVA) at 1 year was greater in the DE group (87.1% vs. 47.7%; log-rank = .004). DE was associated with improved 1-year survival and fewer CVAs. Surgical intervention, if feasible, is recommended for LVAD device thrombosis.


Assuntos
Remoção de Dispositivo/estatística & dados numéricos , Insuficiência Cardíaca/mortalidade , Coração Auxiliar/efeitos adversos , Trombose/cirurgia , Idoso , Anticoagulantes/administração & dosagem , Chicago/epidemiologia , Feminino , Insuficiência Cardíaca/terapia , Heparina/administração & dosagem , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Trombose/tratamento farmacológico , Trombose/etiologia
12.
J Card Surg ; 35(2): 405-412, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31850548

RESUMO

BACKGROUND: Hemocompatibility-related clinical adverse events (HRAEs) are major causes of readmission in patients with left ventricular assist devices (LVADs). Omega-3 is an unsaturated fatty acid that possesses anti-inflammatory and antiangiogenic properties. We aimed to investigate the impact of omega-3 therapy on HRAEs during LVAD support. METHODS: Consecutive LVAD patients who were followed for 6 months were enrolled, and stratified by the use of omega-3. Freedom from any HRAEs and net burden of HRAEs, which was calculated by using a hemocompatibility score (using 4 escalating tiers of hierarchal severity to derive a total score for events), were compared between those with and without omega-3 therapy. RESULTS: Among 169 LVAD patients (57 years old and 124 males), 31 patients received 4 g/d of omega-3 therapy and 138 patients were in the control group. During the 6-month observational period, freedom from any HRAEs was 90% in the omega-3 group compared with 70% in the control group with a hazard ratio of 0.35 (95% confidence interval 0.11-0.87 and P = .042). The average hemocompatibility score in the omega-3 group was significantly lower compared with the control group (0.23 vs 0.91; P = .042), due to reduced Tier I scores (mild HRAE; P = .003) and Tier IIIB scores (severe HRAE; P < .001). The similar trends remained at propensity-matched populations. CONCLUSIONS: Omega-3 therapy was associated with reduced HRAEs including both bleeding and thromboembolic events in LVAD patients.


Assuntos
Ácidos Graxos Ômega-3/administração & dosagem , Hemorragia Gastrointestinal/etiologia , Hemorragia Gastrointestinal/prevenção & controle , Coração Auxiliar/efeitos adversos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Tromboembolia/etiologia , Tromboembolia/prevenção & controle , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
13.
J Card Fail ; 25(1): 20-26, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30415014

RESUMO

BACKGROUND: The NupulseCV intravascular ventricular assist system (iVAS), which consists of a durable pump placed through the subclavian artery, provides extended-duration ambulatory counterpulsation. This study investigated the effect of iVAS on biventricular cardiac function. METHODS AND RESULTS: We reviewed all heart failure patients who received iVAS implantation as a bridge to transplantation or a bridge to candidacy since April 2016 as part of the iVAS first-in-humans and subsequent feasibility study. We compared data of transthoracic echocardiography performed just before implantation (without iVAS support) and again at 30 days or just before explantation (on iVAS support). Eighteen patients (58.8 ± 7.4 years old and 15 male) received iVAS support for 53 ± 43 days. Fourteen patients were bridged to cardiac replacement therapy after 35 ± 19 days and the remaining 4 patients had been supported for 118 ± 41 days. There were no deaths during iVAS support. At 30 days, there was a significant improvement in left ventricular ejection fraction (16.5% ± 11.9% vs 24.4% ± 12.8%; P = .007) and marked reduction in left atrial size (62.7 ± 35.7 mL/m2 vs 33.8 ± 17.2 mL/m2; P < .001). Right ventricular fractional area change improved dramatically (25.4% ± 12.9% vs 42.1% ± 12.4%; P < .001). All other right ventricular and right atrial parameters improved significantly as well (size, tricuspid annular plane systolic excursion, and velocity of tricuspid annular systolic motion). CONCLUSIONS: Improvement in biventricular cardiac function was observed after 30 days of iVAS support. Further studies should examine the use of this technology as a bridge to recovery.


Assuntos
Assistência Ambulatorial/métodos , Contrapulsação/métodos , Insuficiência Cardíaca/terapia , Coração Auxiliar , Função Ventricular Esquerda/fisiologia , Função Ventricular Direita/fisiologia , Idoso , Contrapulsação/instrumentação , Estudos de Viabilidade , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
14.
J Card Fail ; 25(10): 787-794, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31419485

RESUMO

AIM: Hemocompatibility-related adverse events (HRAE) are a major cause of readmissions in patients with left ventricular assist devices (LVAD). The impact of aortic insufficiency (AI) on HRAE remains uncertain. We aimed to investigate the impact of AI on HRAE. METHODS AND RESULTS: Patients who underwent LVAD implantation between August 2014 and July 2017 and had echocardiograms 3 months post-LVAD implantation were enrolled. AI severity was assessed by measuring the systolic/diastolic ratio of flow and the rate of diastolic flow acceleration using Doppler echocardiography of the outflow cannula. Regurgitation fraction was derived from these parameters. Significant AI was defined as regurgitation fraction > 30%. Among 105 patients (median age, 56 years; 76% male), 36 patients (34%) had significant AI. Baseline characteristics were statistically not significantly different between those with and without significant AI except for higher rates of ischemic etiology and atrial fibrillation in the significant AI group (P < 0.05 for both). One-year survival free from HRAE was 44% in patients with AI compared to 67% in patients without significant AI (P = 0.018). The average hemocompatibility score, which defines the net burden of HRAE, was higher in the AI group (1.72 vs 0.64; P = 0.009), due mostly to higher tier I (mild HRAE; P = 0.034) and tier IIIB scores (severe HRAE; P = 0.011). CONCLUSION: Significant AI, as assessed by Doppler echocardiographic parameters, was associated with HRAE during LVAD support.


Assuntos
Insuficiência da Valva Aórtica , Insuficiência Cardíaca , Coração Auxiliar/efeitos adversos , Insuficiência da Valva Aórtica/complicações , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/fisiopatologia , Ecocardiografia Doppler/métodos , Feminino , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/cirurgia , Monitorização Hemodinâmica/métodos , Humanos , Masculino , Teste de Materiais/métodos , Pessoa de Meia-Idade , Estudos Retrospectivos , Índice de Gravidade de Doença , Estados Unidos , Função Ventricular Esquerda
15.
J Card Surg ; 34(12): 1511-1518, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31693250

RESUMO

BACKGROUND: Tricuspid regurgitation (TR) is common in patients receiving left ventricular assist device (LVAD) implantation. The current literature is conflicting regarding the effects of concomitant tricuspid valve repair (TVR) at LVAD implantation. We investigated the hemodynamic effects of concomitant TVR at LVAD implantation. METHODS: Consecutive clinically stable LVAD outpatients who underwent hemodynamic ramp testings were enrolled in this study, and they were stratified by concomitant TVR. Results of hemodynamic ramp tests were compared between the TVR group and the non-TVR group. RESULTS: Among 65 LVAD patients undergoing ramp tests, 34 patients had received TVR, and 31 had not. There were no significant differences in baseline characteristics between two groups except for higher degree of TR and lower pulmonary artery pulsatility index in the TVR group (P < .05 for both). Following LVAD implantation, the degree of TR improved significantly in the TVR group down to the comparable level with the non-TVR group. During ramp tests, the TVR group had steeper cardiac index slope (0.14 ± 0.12 vs 0.07 ± 0.07 L/min/m2 /step, P = .002) and higher cardiac index at set LVAD speed (2.99 ± 0.84 vs 2.52 ± 0.42 L/min/m2 , P = .007). CONCLUSIONS: Concomitant TVR improves cardiac output and its response to LVAD speed change following LVAD implantation. Longitudinal clinical implications of such hemodynamic changes are unknown.


Assuntos
Débito Cardíaco/fisiologia , Insuficiência Cardíaca/cirurgia , Implante de Prótese de Valva Cardíaca , Coração Auxiliar , Hemodinâmica , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Idoso , Teste de Esforço , Feminino , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Tricúspide/fisiopatologia
16.
J Card Fail ; 24(2): 101-108, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29325797

RESUMO

BACKGROUND: Cardiovascular implantable electronic devices (CIEDs) are common in patients undergoing heart transplantation (HT), and complete removal is not always possible at the time of transplantation. METHODS: We retrospectively assessed the frequency of retained CIED leads and clinical consequences in consecutive HT patients from 2013 to 2016. Clinical outcomes included bacteremia, upper-extremity deep venous thrombosis (UEDVT), lead migration, and inability to perform magnetic resonance imaging (MRI). RESULTS: A total of 138 patients (55 ± 11 years of age, 76% male) were identified; 37 (27%) had retained lead fragments (RLFs) at discharge. Patients with RLFs were older, had longer lead implantation time before HT, and a higher prevalence of dual-coil CIED leads compared with those without RLFs (P < .05 for all). Lead implantation time was identified as an independent predictor for RLFs (P < .05). Patients with RLFs had a higher frequency of DVT compared with the non-RLF group during the 1-year study period (42% vs 21%; P < .04). There was no difference in bacteremia. Fourteen patients (38%) could not undergo clinically indicated MRI. CONCLUSION: RLFs after HT occur commonly and are associated with a higher rate of UEDVT and limit the use of MRI. Although no significant difference was found in the rates of bacteremia between the groups, this finding might be explained by the overall low incidence. Patients with risk factors for RLFs should be identified before transplantation, and complete lead removal should be considered with a multidisciplinary approach.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo , Insuficiência Cardíaca/terapia , Transplante de Coração , Marca-Passo Artificial/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Medição de Risco , Feminino , Seguimentos , Insuficiência Cardíaca/fisiopatologia , Humanos , Illinois/epidemiologia , Incidência , Imagem Cinética por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/cirurgia , Estudos Retrospectivos , Fatores de Risco , Volume Sistólico , Fatores de Tempo
18.
J Card Fail ; 24(9): 575-582, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30103020

RESUMO

BACKGROUND: Decoupling between diastolic pulmonary arterial pressure (dPAP) and pulmonary arterial wedge pressure (PAWP) is an index of pulmonary vasculature remodeling and provides prognostic information. Furthermore, decoupling may change during incremental left ventricular assist device (LVAD) speed changes. METHODS AND RESULTS: In this prospective study, patients underwent an echocardiographic and hemodynamic ramp test after LVAD implantation and were followed for 1 year. The change in decoupling (dPAP - PAWP) between the lowest and highest LVAD speeds during the ramp test was calculated. Survival and heart failure admission rates were assessed by means of Kaplan-Meier analysis. Eighty-seven patients were enrolled in the study: 54 had a Heartmate II LVAD (60.8 ± 9.3 years of age and 34 male) and 33 had an HVAD LVAD (58.6 ± 13.2 years of age and 20 male). Patients who experienced greater changes in decoupling (Δdecoupling >3 mm Hg) had a persistently elevated dPAP at incremental LVAD speed and had worse 1-year heart failure readmission-free survival compared with the group without significant changes in the degree of decoupling (41% vs 75%; P = .001). CONCLUSIONS: An increase in decoupling between dPAP and PAWP at incremental LVAD speed changes was associated with worse prognosis in LVAD patients.


Assuntos
Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/fisiopatologia , Coração Auxiliar , Pressão Propulsora Pulmonar/fisiologia , Função Ventricular Esquerda/fisiologia , Pressão Arterial , Progressão da Doença , Ecocardiografia , Feminino , Seguimentos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos
19.
J Card Fail ; 24(9): 561-567, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30048771

RESUMO

BACKGROUND: The assessment of hemodynamics in patients supported with left ventricular assist devices (LVADs) is often challenging. Physical examination maneuvers correlate poorly with true hemodynamics. We assessed the value of novel transthoracic echocardiography (TTE)-derived variables to reliably predict hemodynamics in patients supported with LVAD. METHODS AND RESULTS: A total of 102 Doppler-TTE images of the LVAD outflow cannula were obtained during simultaneous invasive right heart catheterization (RHC) in 30 patients supported with continuous-flow LVADs (22 HMII, 8 HVAD) either during routine RHC or during invasive ramp testing. Properties of the Doppler signal though the outflow cannula were measured at each ramp stage (RS), including the systolic slope (SS), diastolic slope (DS), and velocity time integral (VTI). Hemodynamic variables were concurrently recorded, including Doppler opening pressure (MAP), heart rate (HR), right atrial pressure, pulmonary artery pressure, pulmonary capillary wedge pressure (PCWP), Fick cardiac output (CO) and systemic vascular resistance (SVR). Univariate and multivariate regression analyses were used to explore the dependence of PCWP, CO, and SVR on DS, SS, VTI, MAP, HR, and RS. Multivariate linear regression analysis revealed significant contributions of DS on PCWP (PCWPpred = 0.164DS + 4.959; R = 0.68). Receiver operating characteristic (ROC) curve analysis revealed that PCWPpred could predict an elevated PCWP ≥18 mm Hg with a sensitivity (Sn) of 94% and specificity (Sp) of 85% (area under the ROC curve 0.88). CO could be predicted by RS, VTI, and HR (COpred = 0.017VTI + 0.016HR + 0.12RS + 2.042; R = 0.61). COpred could predict CO ≤4.5 L/min with Sn 73% and Sp 79% (AUC 0.81). SVR could be predicted by MAP, VTI, and HR (SVRpred = 15.44MAP - 5.453VTI - 6.349HR + 856.15; R = 0.84) with Sn 84% and Sp 79% (AUC 0.91) to predict SVR ≥1200 dyn-s/cm5. CONCLUSIONS: Doppler-TTE variables derived from the LVAD outflow cannula can reliably predict PCWP, CO, and SVR in patients supported with LVADs and may mitigate the need for invasive testing.


Assuntos
Ecocardiografia Doppler/métodos , Insuficiência Cardíaca/terapia , Ventrículos do Coração/diagnóstico por imagem , Coração Auxiliar , Hemodinâmica/fisiologia , Adulto , Idoso , Feminino , Seguimentos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos
20.
Cureus ; 16(2): e55299, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38562264

RESUMO

OBJECTIVE: The objective of this study was to assess the efficacy of the combined program of transdiagnostic treatment and parent education in reducing social anxiety among female students. METHODOLOGY:  This descriptive cross-sectional study was conducted among all female elementary school students in Bandar Abbas, Iran, during the academic year 2022-2023. The social phobia questionnaire was given to all female students in grades three to six to assess individuals in terms of the social anxiety disorder (SAD) variable. We used the social anxiety scale developed by Leibovitz as the questionnaire in this investigation. This self-assessment questionnaire was designed for individuals aged 18 and above. It consists of 24 statements, divided into two subscales: performance anxiety (13 statements) and social settings (11 statements). Each item is individually assessed for fear intensity on a scale of 0 to 3, ranging from no to extreme. Similarly, avoidance behavior is evaluated on a scale of 0 to 3, representing the frequency ranging from never to always. RESULTS:  The mean general anxiety levels among both groups (students vs. parents) during the pre-test were similar (48.06 ± 4.39 vs. 48.06± 4.1). However, in the post-test, the mean of the experimental groups was lower than that of the pre-test (32.13 ± 3.77 vs. 47.2 ± 3.6). The normality assumption for the pre-test and post-test variables of generalized anxiety was verified with a significance level over 0.05 (p ≥ 0.05). CONCLUSION: The findings demonstrated that the integrated meta-diagnostic treatment program for parents had a more pronounced effect on alleviating their social anxiety in comparison to students. These findings imply that if parents possess a comprehensive understanding of the factors contributing to their children's anxiety, it will significantly enhance their ability to mitigate their child's social anxiety.

SELEÇÃO DE REFERÊNCIAS