Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Anaesthesia ; 79(8): 849-855, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38606765

RESUMO

BACKGROUND: Recommendations exist that aim to mitigate the substantial ecological impact of anaesthesia. One option is to use anaesthetic gas capturing technology at anaesthesia workstation exhausts to harvest and recycle volatile agents. However, the efficiency of such technology is mainly unverified in vivo. METHODS: The efficiency of CONTRAfluran™ in capturing sevoflurane from an anaesthesia workstation exhaust (when set to minimal flow and end-tidal control mode) was evaluated in 70 adult patients scheduled for general or bariatric laparoscopic surgery. The weight of the sevoflurane vaporiser and CONTRAfluran canister was measured before and after each case, to calculate total sevoflurane consumption and retention. Retention was measured after the minimal flow maintenance phase and after the high flow washout phase. The total retention efficiency was the fraction of all consumed sevoflurane captured by the CONTRAfluran canister. The primary objective was to examine the retention efficiency of CONTRAfluran in a clinical surgical setting, where all feasible strategies to minimise sevoflurane consumption and optimise the efficacy of CONTRAfluran were utilised. The secondary objective was to analyse the correlation between mass transfer and the duration of the case. RESULTS: Mean (SD) volume of sevoflurane captured using CONTRAfluran was 4.82 (1.41) ml, representing 45% (95%CI 42-48%) of all sevoflurane administered. The highest amount of retention was found during the washout phase. Retention efficiency did not correlate with the duration of the case. CONCLUSIONS: Over half of the sevoflurane administered was not captured by the CONTRAfluran canister when minimal flow techniques were used, likely due to residual accumulation of sevoflurane in the patient after tracheal extubation or, to a lesser extent, due to ventilation system leakage. However, as every prevented emission is commendable, CONTRAfluran may be a potentially valuable tool for reducing the environmental footprint of sevoflurane-based anaesthesia.


Assuntos
Anestésicos Inalatórios , Laparoscopia , Sevoflurano , Sevoflurano/administração & dosagem , Humanos , Anestésicos Inalatórios/administração & dosagem , Laparoscopia/métodos , Masculino , Pessoa de Meia-Idade , Feminino , Adulto , Idoso , Anestesia por Inalação/métodos , Anestesia por Inalação/instrumentação , Poluição do Ar em Ambientes Fechados/prevenção & controle
2.
J Clin Monit Comput ; 37(3): 881-887, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36586033

RESUMO

Volatile anaesthetics are potent greenhouse gasses but contemporary workstations enable considerable savings while improving patient safety. Institutions may provide this technology to reduce the ecological footprint but proper training and motivation is required to maximize their ecologic and financial benefit. This study aims to compare the sevoflurane consumption of 22 anaesthesiologists in a medium sized hospital 4 years after flow-i workstations (Getinge, Sweden) entered into service, in three airway approaches: intubated patients, laryngeal mask ventilation, and mask anaesthesia. Typical sevoflurane consumption for each anaesthesiologist was defined as the mean cumulative consumption in the chronologically first 50 cases meeting the inclusion criteria for each airway group in 2019. The potential savings, if everyone were to adopt the approach of the more economical anaesthesiologists (15th percentile), was calculated. The CO2 equivalent emissions were calculated using a GWP20 of 702 and a GWP100 of 195. The median [range] consumption after 45 min was 10.9 [7.5-18.4] ml in intubated patients and 9.0 [7.4-15.3] ml in patients with laryngeal mask, and 9.9 [3.4-20.9] ml after 8 min with mask ventilation. This corresponds to a double to six fold consumption between the least and most wasteful approach. The typical CO2 equivalent emissions (GWP20) per anaesthesiologist varied between 8.0 and 19.6 kg/45 min in intubated airways, between 7.9 and 16.3 kg/45 min in LMA, and between 3.6 and 22.3 kg/8 min in mask ventilation. Despite using the same workstations in the same hospital, the typical sevoflurane consumption differed dramatically between 22 anaesthesiologists. In addition to providing advanced workstations, proper education is required to achieve the behavior change needed to reduce the pollution and financial waste associated with volatile anaesthetics.


Assuntos
Anestésicos Inalatórios , Máscaras Laríngeas , Éteres Metílicos , Humanos , Dióxido de Carbono , Hospitais , Sevoflurano/administração & dosagem , Sevoflurano/efeitos adversos , Anestesiologistas
3.
J Clin Monit Comput ; 36(6): 1601-1610, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-34978655

RESUMO

Both ecological and economic considerations dictate minimising wastage of volatile anaesthetics. To reconcile apparent opposing stakes between ecological/economical concerns and stability of anaesthetic delivery, new workstations feature automated software that continually optimizes the FGF to reliably obtain the requested gas mixture with minimal volatile anaesthetic waste. The aim of this study is to analyse the kinetics and consumption pattern of different approaches of sevoflurane delivery with the same 2% end-tidal goal in all patients. The consumption patterns of sevoflurane of a Flow-i were retrospectively studied in cases with a target end-tidal sevoflurane concentration (Etsevo) of 2%. For each setting, 25 cases were included in the analysis. In Automatic Gas Control (AGC) regulation with software version V4.04, a speed setting 6 was observed; in AGC software version V4.07, speed settings 2, 4, 6 and 8 were observed, as well as a group where a minimal FGF was manually pursued and a group with a fixed 2 L/min FGF. In 45 min, an average of 14.5 mL was consumed in the 2L-FGF group, 5.0 mL in the minimal-manual group, 7.1 mL in the AGC4.04 group and 6.3 mL in the AGC4.07 group. Faster speed AGC-settings resulted in higher consumption, from 6.0 mL in speed 2 to 7.3 mL in speed 8. The Etsevo target was acquired fastest in the 2L-FGF group and the Etsevo was more stable in the AGC groups and the 2L-FGF groups. In all AGC groups, the consumption in the first 8 min was significantly higher than in the minimal flow group, but then decreased to a comparable rate. The more recent AGC4.07 algorithm was more efficient than the older AGC4.04 algorithm. This study indicates that the AGC technology permits very significant economic and ecological benefits, combined with excellent stability and convenience, over conventional FGF settings and should be favoured. While manually regulated minimal flow is still slightly more economical compared to the automated algorithm, this comes with a cost of lower precision of the Etsevo. Further optimization of the AGC algorithms, particularly in the early wash-in period seems feasible. In AGC mode, lower speed settings result in significantly lower consumption of sevoflurane. Routine clinical practice using what historically is called "low flow anaesthesia" (e.g. 2 L/min FGF) should be abandoned, and all anaesthesia machines should be upgraded as soon as possible with automatic delivery technology to minimize atmospheric pollution with volatile anaesthetics.


Assuntos
Anestésicos Inalatórios , Éteres Metílicos , Humanos , Sevoflurano , Anestesia por Inalação/métodos , Estudos Retrospectivos , Tecnologia
4.
BMC Anesthesiol ; 20(1): 258, 2020 10 07.
Artigo em Inglês | MEDLINE | ID: mdl-33028197

RESUMO

BACKGROUND: Balanced anaesthesia with propofol and remifentanil, compared to sufentanil, often decreases mean arterial pressure (MAP), heart rate (HR) and cardiac index (CI), raising concerns on tissue-oxygenation. This distinct haemodynamic suppression might be attenuated by atropine. This double blinded RCT, investigates if induction with propofol-sufentanil results in higher CI and tissue-oxygenation than with propofol-remifentanil and if atropine has more pronounced beneficial effects on CI and tissue-oxygenation in a remifentanil-based anaesthesia. METHODS: In seventy patients scheduled for coronary bypass grafting (CABG), anaesthesia was induced and maintained with propofol target controlled infusion (TCI) with a target effect-site concentration (Cet) of 2.0 µg ml- 1 and either sufentanil (TCI Cet 0.48 ng ml- 1) or remifentanil (TCI Cet 8 ng ml- 1). If HR dropped below 60 bpm, methylatropine (1 mg) was administered intravenously. Relative changes (∆) in MAP, HR, stroke volume (SV), CI and cerebral (SctO2) and peripheral (SptO2) tissue-oxygenation during induction of anaesthesia and after atropine administration were analysed. RESULTS: The sufentanil group compared to the remifentanil group showed significantly less decrease in MAP (∆ = - 23 ± 13 vs. -36 ± 13 mmHg), HR (∆ = - 5 ± 7 vs. -10 ± 10 bpm), SV (∆ = - 23 ± 18 vs. -35 ± 19 ml) and CI (∆ = - 0.8 (- 1.5 to - 0.5) vs. -1.5 (- 2.0 to - 1.1) l min- 1 m- 2), while SctO2 (∆ = 9 ± 5 vs. 6 ± 4%) showed more increase with no difference in ∆SptO2 (∆ = 8 ± 7 vs. 8 ± 8%). Atropine caused higher ∆HR (13 (9 to 19) vs. 10 ± 6 bpm) and ∆CI (0.4 ± 0.4 vs. 0.2 ± 0.3 l min- 1 m- 2) in sufentanil vs. remifentanil-based anaesthesia, with no difference in ∆MAP, ∆SV and ∆SctO2 and ∆SptO2. CONCLUSION: Induction of anaesthesia with propofol and sufentanil results in improved haemodynamic stability and higher SctO2 compared to propofol and remifentanil in patients having CABG. Administration of atropine might be useful to counteract or prevent the haemodynamic suppression associated with these opioids. TRIAL REGISTRATION: Clinicaltrials.gov on June 7, 2013 (trial ID: NCT01871935 ).


Assuntos
Anestesia , Encéfalo/metabolismo , Hemodinâmica/efeitos dos fármacos , Oxigênio/metabolismo , Remifentanil/farmacologia , Sufentanil/farmacologia , Idoso , Atropina/farmacologia , Ponte de Artéria Coronária , Método Duplo-Cego , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
5.
Acta Orthop Belg ; 86(4): 688-696, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33861917

RESUMO

LIA is an emerging alternative for patient-con- trolled epidural analgesia(PCEA) after total knee arthroplasty(TKA). LIA allows faster mobilisation, eliminates the risks of epidural catheters, and can hasten patient turnover. Conversely, PCEA provides reliable pain relief in the first days after this type of surgery. The purpose of this study was to evaluate the quality of antinociception, postoperative nausea & vomiting (PONV), and general comfort until 7 days postoperatively. 40 patients received PCEA and 41 received LIA. Patients were retrospectively asked for pain scores at the day of surgery(=D0), D2, and D7, PONV, and general comfort scores. Patients in the LIA group reported equal pain scores at D0, significantly better PONV scores and pain scores at D2 and D7. In addition to faster mobilisation and elimination of the risks and burden of an epidural catheter and PCEA, LIA delivers equal to better analgesia, and better PONV and general comfort scores.


Assuntos
Analgesia Epidural , Artroplastia do Joelho , Anestésicos Locais , Artroplastia do Joelho/efeitos adversos , Humanos , Manejo da Dor , Dor Pós-Operatória , Estudos Retrospectivos
6.
J Surg Res ; 238: 1-9, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30721780

RESUMO

BACKGROUND: Conventional rigid laparoscopic instruments offer five degrees of freedom (DOF). Robotic instruments add two independent DOFs allowing unconstrained directional steering. Several nonrobotic instruments have been developed with the additional DOFs, but with these devices, surgeon's wrist movements are not intuitively transmitted into tip movements. In this study, a new articulated instrument has been evaluated. The aim of the study was to compare learning curves and performances of conventional laparoscopic instruments, the da Vinci system and Steerable devices in a crossover study. MATERIALS AND METHODS: A total of 16 medical students without any laparoscopic experience were trained for 27 h to operate all of a rigid, a robotic, and a new Steerable instrument in a random order. Learning curves and ultimate experience scores were determined for each instrument. Strain in wrist and shoulders was assessed with a visual analog score. RESULTS: Performing the suturing task with rigid and robot instruments required 4 h of training, compared with 6 h to master the Steerable instrument. After 9 h of training with each instrument, completing the complex suturing pattern required 662 ± 308 s with rigid instruments, 279 ± 90 s with the da Vinci system, and 279 ± 53 s with the Steerable instrument. Pain scores were significantly higher after using the rigid instruments compared with the Steerable instruments. CONCLUSIONS: Transmission of torque and the presence of additional two DOFs in combination with reduced crosstalk significantly improved the instrument dexterity where the Steerable platform is concerned. Although the learning curve is longer, once mastered, it provides enhanced surgical freedom.


Assuntos
Encéfalo/fisiologia , Laparoscopia/educação , Curva de Aprendizado , Procedimentos Cirúrgicos Robóticos/educação , Estudantes de Medicina/psicologia , Competência Clínica , Estudos Cross-Over , Educação de Graduação em Medicina , Ergonomia , Feminino , Antebraço/fisiologia , Humanos , Laparoscopia/instrumentação , Masculino , Amplitude de Movimento Articular/fisiologia , Procedimentos Cirúrgicos Robóticos/instrumentação , Técnicas de Sutura/educação , Técnicas de Sutura/instrumentação , Punho/fisiologia , Adulto Jovem
7.
Langenbecks Arch Surg ; 404(5): 557-564, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31243573

RESUMO

BACKGROUND: Since the implementation of total mesorectal excision (TME) in rectal cancer surgery, oncological outcomes improved dramatically. With the technique of complete mesocolic excision (CME) with central vascular ligation (CVL), the same surgical principles were introduced to the field of colon cancer surgery. Until now, current literature fails to invariably demonstrate its oncological superiority when compared to conventional surgery, and there are some concerns on increased morbidity. The aim of this study is to compare short-term outcomes after left-sided laparoscopic CME versus conventional surgery. METHODS: In this retrospective analysis, data on all laparoscopic sigmoidal resections performed during a 3-year period (October 2015 to October 2018) at our institution were collected. A comparative analysis between the CME group-for sigmoid colon cancer-and the non-CME group-for benign disease-was performed. RESULTS: One hundred sixty-three patients met the inclusion criteria and were included for analysis. Data on 66 CME resections were compared with 97 controls. Median age and operative risk were higher in the CME group. One leak was observed in the CME group (1/66) and 3 in the non-CME group (3/97), representing no significant difference. Regarding hospital stay, postoperative complications, surgical site infections, and intra-abdominal collections, no differences were observed. There was a slightly lower reoperation (1.5% versus 6.2%, p = 0.243) and readmission rate (4.5% versus 6.2%, p = 0.740) in the CME group during the first 30 postoperative days. Operation times were significantly longer in the CME group (210 versus 184 min, p < 0.001), and a trend towards longer pathological specimens in the CME group was noted (21 vs 19 cm, p = 0.059). CONCLUSIONS: CME does not increase short-term complications in laparoscopic left-sided colectomies. Significantly longer operation times were observed in the CME group.


Assuntos
Colectomia/efeitos adversos , Neoplasias do Colo/cirurgia , Laparoscopia/efeitos adversos , Mesocolo/cirurgia , Complicações Pós-Operatórias/epidemiologia , Idoso , Neoplasias do Colo/patologia , Feminino , Humanos , Tempo de Internação , Ligadura , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
12.
Surg Innov ; 26(4): 456-463, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30667302

RESUMO

Objective. The introduction of advanced endoscopic systems, such as the Storz Image1S and the Olympus Endoeye, heralds a new era of 3-dimensional (3D) visualization. The aim of this report is to provide a comprehensive overview of the neurophysiology of 3D view, its relevance in videoscopy, and to quantify the benefit of the new 3D technologies for both rigid and articulated instruments. Method. Sixteen medical students without any laparoscopic experience were trained each for a total of 27 hours. Proficiency scores were determined for rigid and articulated instruments under 2D and 3D visualization conditions. Results. A reduction in execution time of 14%, 28%, and 36% was seen for the rigid instruments, the da Vinci, and Steerable instruments, respectively. A reduction in errors of 84%, 92%, and 87% was seen for the rigid instruments, the da Vinci, and Steerable instruments, respectively. Conclusion. 3D visualization greatly augments endoscopic procedures. The advanced endoscopic systems employed in the recent study caused no visual fatigue or discomfort. The benefit of 3D was most distinct with articulated instruments.


Assuntos
Astenopia/etiologia , Educação de Graduação em Medicina/métodos , Imageamento Tridimensional/instrumentação , Laparoscopia/instrumentação , Erros Médicos/estatística & dados numéricos , Instrumentos Cirúrgicos , Bélgica , Competência Clínica , Avaliação Educacional , Desenho de Equipamento , Feminino , Humanos , Masculino , Duração da Cirurgia , Estudantes de Medicina , Análise e Desempenho de Tarefas , Adulto Jovem
17.
Eur J Anaesthesiol ; 34(10): 695-701, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28403018

RESUMO

BACKGROUND: Induction of anaesthesia with propofol and remifentanil often induces unwanted bradycardia and hypotension, raising concerns regarding tissue oxygenation. The electrophysiological cardiac effects of remifentanil can be reversed by atropine. OBJECTIVE: To investigate if prophylactic administration of atropine can attenuate the negative haemodynamic effects of propofol and a high dose of remifentanil during induction of anaesthesia. DESIGN: A double-blind, randomised controlled trial. SETTING: Single-centre, University Medical Center Groningen, The Netherlands. PATIENTS: Sixty euvolaemic patients scheduled for surgery under general anaesthesia. INTERVENTIONS: Anaesthesia was induced and maintained with a target-controlled infusion of propofol with a target effect-site concentration (Ce) of 2.5 µg ml, remifentanil (target-controlled infusion), (Ce 8 ng ml) and cis-atracurium. Methylatropine (500 µg) or 0.9% saline was administered at immediately before induction of anaesthesia. MAIN OUTCOME MEASURES: The changes (Δ) in mean arterial pressure (MAP), heart rate (HR), cardiac index (CI), rate pressure product, cerebral tissue oxygenation and peripheral tissue oxygenation between induction of anaesthesia (T0) and 10 min later (T10). RESULTS: Atropine significantly attenuated the changes in the outcome measures between T0 and T10. Median (inter-quartile range) changes were MAP, Δ = -24 (-40 to -21) vs. Δ = -37 mmHg (-41 to -31) (P = 0.02); HR, Δ = 0 ±â€Š13 vs. -19 ±â€Š11 bpm (P < 0.01); CI, Δ = -0.4 ±â€Š0.7 vs. -0.9 ±â€Š0.6l min m (P < 0.01) and rate pressure product, Δ = -3241 (-5015 to -613) vs. Δ = -5712 mmHg min (-6715 to -3917) (P < 0.01). Cerebral tissue oxygenation and peripheral tissue oxygenation did not change in either group. Maximum HR after atropine was 102 (86 to 116) vs. 85 bpm (76 to 95). CONCLUSION: Administration of atropine, before induction of anaesthesia with propofol and high-dose remifentanil, can significantly reduce the decreases in HR, MAP and CI. TRIAL REGISTRATION: Clinicaltrials.gov identifier: NCT01871922.


Assuntos
Analgésicos Opioides/administração & dosagem , Atropina/administração & dosagem , Hemodinâmica/efeitos dos fármacos , Piperidinas/administração & dosagem , Profilaxia Pré-Exposição/métodos , Propofol/administração & dosagem , Adjuvantes Anestésicos/administração & dosagem , Adulto , Idoso , Analgésicos Opioides/efeitos adversos , Relação Dose-Resposta a Droga , Método Duplo-Cego , Quimioterapia Combinada , Feminino , Hemodinâmica/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Piperidinas/efeitos adversos , Propofol/efeitos adversos , Estudos Prospectivos , Remifentanil
18.
J Clin Monit Comput ; 36(5): 1569-1571, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35298737
20.
Anesth Analg ; 122(2): 382-92, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26505573

RESUMO

BACKGROUND: Current electroencephalogram (EEG)-derived measures provide information on cortical activity and hypnosis but are less accurate regarding subcortical activity, which is expected to vary with the degree of antinociception. Recently, the neurophysiologically based EEG measures of cortical input (CI) and cortical state (CS) have been shown to be prospective indicators of analgesia/antinociception and hypnosis, respectively. In this study, we compared CI and an alternate measure of CS, the composite cortical state (CCS), with the Bispectral Index (BIS) and another recently developed measure of antinociception, the composite variability index (CVI). CVI is an EEG-derived measure based on a weighted combination of BIS and estimated electromyographic activity. By assessing the relationship between these indices for equivalent levels of hypnosis (as quantified using the BIS) and the nociceptive-antinociceptive balance (as determined by the predicted effect-site concentration of remifentanil), we sought to evaluate whether combining hypnotic and analgesic measures could better predict movement in response to a noxious stimulus than when used alone. METHODS: Time series of BIS and CVI indices and the raw EEG from a previously published study were reanalyzed. In our current study, the data from 80 patients, each randomly allocated to a target hypnotic level (BIS 50 or BIS 70) and a target remifentanil level (Remi-0, -2, -4 or -6 ng/mL), were included in the analysis. CCS, CI, BIS, and CVI were calculated or quantified at baseline and at a number of intervals after the application of the Observer's Assessment of Alertness/Sedation scale and a subsequent tetanic stimulus. The dependency of the putative measures of antinociception CI and CVI on effect-site concentration of remifentanil was then quantified, together with their relationship to the hypnotic measures CCS and BIS. Finally, statistical clustering methods were used to evaluate the extent to which simple combinations of antinociceptive and hypnotic measures could better detect and predict response to stimulation. RESULTS: Before stimulation, both CI and CVI differentiated patients who received remifentanil from those who were randomly allocated to the Remi-0 group (CI: Cohen's d = 0.65, 95% confidence interval, 0.48-0.83; CVI: Cohen's d = 0.72, 95% confidence interval, 0.56-0.88). Strong correlations between BIS and CCS were found (at different periods: 0.55 < R2 < 0.68, P < 0.001). Application of the Observer's Assessment of Alertness/Sedation stimulus was associated with changes in CI and CCS, whereas, subsequent to the application of both stimuli, changes in all measures were seen. Pairwise combinations of CI and CCS showed higher sensitivity in detecting response to stimulation than CVI and BIS combined (sensitivity [99% confidence interval], 75.8% [52.7%-98.8%] vs 42% [15.4%-68.5%], P = 0.006), with specificity for CI and CCS approaching significance (52% [34.7%-69.3%] vs 24% [9.1%-38.9%], P = 0.0159). CONCLUSIONS: Combining electroencephalographically derived hypnotic and analgesic quantifiers may enable better prediction of patients who are likely to respond to tetanic stimulation.


Assuntos
Anestesia Intravenosa/métodos , Anestésicos Intravenosos , Eletroencefalografia/métodos , Nociceptividade/efeitos dos fármacos , Piperidinas , Propofol , Adolescente , Adulto , Idoso , Nível de Alerta , Córtex Cerebral/efeitos dos fármacos , Sedação Consciente , Monitores de Consciência , Sedação Profunda , Estimulação Elétrica , Eletromiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória , Estudos Prospectivos , Remifentanil , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA