Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Electrocardiol ; 44(3): 346-9, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21419423

RESUMO

BACKGROUND: Risk stratification of asymptomatic individuals with type 1 electrocardiogram (ECG) phenotype of Brugada syndrome (BS) still remains controversial. This study investigated the long-term prognosis of asymptomatic subjects with spontaneous or drug-induced type 1 ECG pattern of BS. METHODS AND RESULTS: Data from 33 apparently healthy individuals (30 males; age, 43.6 ± 13.4 years) with spontaneous (n = 12) or drug-induced (n = 21) type 1 ECG pattern of BS were retrospectively analyzed. Thirteen subjects (39.4%) displayed a positive family history of BS and/or sudden cardiac death. Electrophysiologic study was performed in 16 subjects, and programed right ventricular stimulation induced polymorphic ventricular tachycardia in 9 (56.3%) of them. A cardioverter defibrillator was implanted in 6 cases. During a mean follow-up period of 5.3 ± 2.8 years, all subjects remained asymptomatic. None of them had syncope or cardioverter defibrillator discharges due to ventricular arrhythmias. CONCLUSIONS: Asymptomatic individuals with spontaneous or drug-induced type 1 ECG phenotype of BS display a benign clinical course during long-term follow-up.


Assuntos
Síndrome de Brugada/induzido quimicamente , Síndrome de Brugada/fisiopatologia , Eletrocardiografia/métodos , Adulto , Síndrome de Brugada/terapia , Desfibriladores Implantáveis , Feminino , Seguimentos , Humanos , Masculino , Fenótipo , Prognóstico , Estudos Retrospectivos , Medição de Risco
2.
J Cardiovasc Electrophysiol ; 21(2): 120-5, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19793145

RESUMO

BACKGROUND: Pulmonary vein (PV) isolation using a balloon-mounted cryoablation system is a new technology for the percutaneous treatment of atrial fibrillation (AF). Complete PV occlusion during balloon ablation has been shown to predict successful electrical isolation. The aim of this study was to correlate mechanical PV occlusion with changes in a pressure curve recorded at the distal tip of the cryoballoon catheter. METHODS AND RESULTS: We analyzed 51 PVs in 12 patients (61 +/- 6 years old) with paroxysmal AF. At first, PV occlusion via the cryoballoon was documented by changes in the pressure curve. Once the PV is occluded, the pressure curve registered in the vein converts from a left atrial pressure curve to a pulmonary artery pressure curve: the PV wedge curve. Occlusion was then confirmed by transesophageal echocardiography (TEE). Following 2 cryoablation applications, electrical PV isolation was assessed with a circumferential mapping catheter. Under the exclusive guidance of changes in the pressure curve at the tip of the cryoballoon, mechanical occlusion confirmed by TEE was achieved in 47 of 51 PVs (92%). Three PVs required further TEE guidance to achieve occlusion. All 50 occluded veins were electrically isolated after cryoablation. One right inferior vein, which could not be occluded with the balloon, displayed conduction post cryoablation and was isolated by focal ablation. CONCLUSIONS: Occlusion and electrical isolation of PVs during cryoballoon ablation can be predicted by the appearance of a PV wedge curve at the tip of the catheter. This new straightforward parameter may facilitate the procedure.


Assuntos
Fibrilação Atrial/cirurgia , Determinação da Pressão Arterial/métodos , Cateterismo/métodos , Criocirurgia/métodos , Sistema de Condução Cardíaco/cirurgia , Veias Pulmonares/cirurgia , Fibrilação Atrial/diagnóstico , Determinação da Pressão Arterial/instrumentação , Cateterismo/instrumentação , Criocirurgia/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
3.
Europace ; 12(2): 271-4, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19897501

RESUMO

AIMS: The present study investigated whether several ECG markers of ventricular repolarization are associated with ventricular tachycardia/fibrillation (VT/VF) inducibility in subjects with type 1 ECG pattern of Brugada syndrome (BS). METHODS AND RESULTS: The clinical data of 23 individuals (19 males, age 42.69 +/- 14.63) with spontaneous (n = 10) or drug-induced (n = 13) type 1 ECG pattern of BS who underwent programmed ventricular stimulation were analysed. Sustained VT/VF was induced in 17 subjects (74%) and was significantly associated with the presence of spontaneous type 1 ECG of BS (P = 0.012). Among the studied ECG repolarization markers, subjects with inducible VT/VF displayed an increased T(peak)-T(end) interval in leads V(2) (88.82 +/- 15.70 vs. 78.33 +/- 4.08 ms, P = 0.02) and V(6) (76.33 +/- 10.08 vs. 66.66 +/- 5.16 ms, P = 0.04) and a greater T(peak)-T(end)/QT ratio in lead V(6) (0.214 +/- 0.028 vs. 0.180 +/- 0.014, P = 0.009) compared with those without arrhythmias. Ventricular tachycardia/fibrillation inducibility was not associated with arrhythmic events during a mean follow-up period of 4.61 +/- 2.14 years (P = 0.739). CONCLUSION: The T(peak)-T(end) interval and T(peak)-T(end)/QT ratio were associated with VT/VF inducibility in BS. The utility of T(peak)-T(end)/QT ratio as a new marker of arrhythmogenesis in BS requires further studies, including a large number of patients.


Assuntos
Síndrome de Brugada/fisiopatologia , Eletrocardiografia , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/fisiopatologia , Adulto , Ajmalina/efeitos adversos , Antiarrítmicos/efeitos adversos , Biomarcadores , Síndrome de Brugada/induzido quimicamente , Feminino , Flecainida/efeitos adversos , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de Risco , Fibrilação Ventricular/epidemiologia , Fibrilação Ventricular/fisiopatologia
4.
Acta Cardiol ; 65(2): 171-6, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20458824

RESUMO

OBJECTIVE: The present study aimed to evaluate the diagnostic value of specific ECG markers in the differentiation of common type atrioventricular nodal reentrant tachycardia (AVNRT) and atrioventricular reentrant tachycardia (AVRT) via a concealed accessory pathway. METHODS: One hundred and ten ECGs with paroxysmal narrow QRS complex, short RP tachycardia were evaluated. Subjects with overt ventricular pre-excitation during sinus rhythm were excluded from the study. The mechanism of arrhythmia was established during the electrophysiological study and confirmed by the efficacy of radiofrequency ablation. RESULTS: Of the 110 patients, 74 displayed common type AVNRT and 36 AVRT. Predictors of AVNRT were the presence of pseudo r'-waves in lead V1 [sensitivity 39.19%; specificity 97.14%; positive predictive value (PPV) 96.67%; negative predictive value (NPV) 43.04%] and pseudo S-waves in inferior leads (sensitivity 28.38%; specificity 94.29%; PPV 91.30%; NPV 38.37%). In the setting of visible P-waves, an RP interval < or =90 ms favoured the diagnosis of AVNRT (sensitivity 57.14%; specificity 80.65%). Predictors of AVRT were QRS alternans (sensitivity 50%; specificity 89.19%; PPV 69.23%; NPV 78.57%) as well as ST-segment alterations during tachycardia. The overall sensitivity, specificity, PPV and NPV of ST-segment depression for discriminating AVRT from AVNRT were 97.22%, 58.11%, 53.03%, 97.73%, respectively. Similarly, the sensitivity, specificity, PPV and NPV of ST-segment elevation in lead aVR were 94.44%, 58.11%, 52.31%, and 95.56%, respectively. Multiple logistic regression analysis showed that ST-segment depression [(odds ratio (OR): 12.67, 95% confidence interval (CI): 1.77-90.81, P = 0.011)] and QRS alternans (OR: 9.43, 95% CI: 1.38-64.37, P = 0.022) displayed the highest predictive ability favouring the diagnosis of AVRT. CONCLUSIONS: Twelve-lead ECG parameters may help to differentiate the mechanism of supraventricular tachycardia prior to the ablation procedure.


Assuntos
Eletrocardiografia , Sistema de Condução Cardíaco/fisiopatologia , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia Reciprocante/diagnóstico , Adulto , Idoso , Algoritmos , Ablação por Cateter , Estudos de Coortes , Intervalos de Confiança , Diagnóstico Diferencial , Eletrocardiografia/métodos , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Taquicardia Reciprocante/fisiopatologia
5.
Circulation ; 117(21): 2727-33, 2008 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-18490526

RESUMO

BACKGROUND: Defibrillator lead malfunction is a potential long-term complication in patients with an implantable cardioverter-defibrillator (ICD). The aim of this study was to determine the incidence and causes of lead malfunction necessitating surgical revision and to evaluate 2 approaches to treat lead malfunction. METHODS AND RESULTS: We included 1317 consecutive patients with an ICD implanted at 3 European centers between 1993 and 2004. The types and causes of lead malfunction were recorded. If the integrity of the high-voltage part of the lead could be ascertained, an additional pace/sense lead was implanted. Otherwise, the patients received a new ICD lead. Of the 1317 patients, 38 experienced lead malfunction requiring surgical revision and 315 died during a median follow-up of 6.4 years. At 5 years, the cumulative incidence was 2.5% (95% confidence interval, 1.5 to 3.6). Lead malfunction resulted in inappropriate ICD therapies in 76% of the cases. Implantation of a pace/sense lead was feasible in 63%. Both lead revision strategies were similar with regard to lead malfunction recurrence (P=0.8). However, the cumulative incidence of recurrence was high (20% at 5 years; 95% confidence interval, 1.7 to 37.7). CONCLUSIONS: ICD lead malfunction necessitating surgical revision becomes a clinically relevant problem in 2.5% of ICD recipients within 5 years. In selected cases, simple implantation of an additional pace/sense lead is feasible. Regardless of the chosen approach, the incidence of recurrent ICD lead-related problems after lead revision is 8-fold higher in this population.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Desfibriladores Implantáveis/estatística & dados numéricos , Falha de Equipamento/estatística & dados numéricos , Reoperação/estatística & dados numéricos , Taquicardia/epidemiologia , Taquicardia/cirurgia , Idoso , Eletrodos Implantados/efeitos adversos , Eletrodos Implantados/estatística & dados numéricos , Feminino , Seguimentos , Parada Cardíaca/epidemiologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taquicardia/terapia , Resultado do Tratamento
6.
J Cardiovasc Electrophysiol ; 20(11): 1197-202, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19563358

RESUMO

BACKGROUND: Pulmonary vein (PV) isolation using a balloon-mounted cryoablation system is a new technology for the percutaneous treatment of atrial fibrillation (AF). Transesophageal echocardiography (TEE) allows real-time visualization of cryoballoon positioning and successful vein occlusion via color Doppler. We hypothesized that PV mechanical occlusion monitored with TEE could predict effective electrical isolation. METHODS: We studied 124 PVs in 30 patients. Under continuous TEE assessment, a cryoballoon was placed in the antrum of each PV aiming for complete PV occlusion as documented by color Doppler. At the end of the procedure, PV electrical isolation was evaluated using a circumferential mapping catheter. RESULTS: Of the 124 PVs studied, 123 (99.2%) could be visualized by TEE: the antrum was completely visualized in 80 of them (64.5%), partially in 36 (29.0%), and only disappearance of proximal flow could be observed in the remaining 7 PVs (5.7%). Vein occlusion could be achieved in 111 of the 123 (90.2%) visualized PVs. Postinterventional mapping demonstrated electrical isolation in 109 of 111 occluded PVs (positive predictive value 98.2%) and only in 1 of 12 nonoccluded PVs (negative predictive value 91.7%, P < 0.001). After a mean follow-up of 7.4 +/- 3.7 months, 73.3% of patients remained in sinus rhythm without antiarrhythmic drugs. CONCLUSION: Color Doppler documented PV occlusion during cryoballoon ablation can predict effective electrical isolation.


Assuntos
Fibrilação Atrial/cirurgia , Cateterismo/métodos , Criocirurgia/métodos , Ecocardiografia Transesofagiana/métodos , Veias Pulmonares/cirurgia , Cirurgia Assistida por Computador/métodos , Cateterismo/tendências , Criocirurgia/tendências , Feminino , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Resultado do Tratamento
7.
Europace ; 11(6): 823-6, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19383671

RESUMO

We report on the characteristics and the ablation procedure of a focal atrial tachycardia originating from the non-coronary aortic cusp. The electrophysiological features of the tachycardia included: (i) incessant pattern; (ii) easy induction and termination by atrial stimulation; (iii) earliest right atrial activation at the para-hisian area; and (iv) termination by adenosine. Left-sided mapping revealed the earliest atrial activation during the tachycardia at the non-coronary aortic cusp. Radiofrequency energy application at this site successfully terminated the tachycardia. Mapping of the non-coronary aortic cusp should always be considered when the earliest right atrial activation is recorded at the para-hisian area in order to avoid the risk of atrioventricular block by inappropriate ablation near the His-bundle region.


Assuntos
Aorta/cirurgia , Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/métodos , Taquicardia Atrial Ectópica/diagnóstico , Taquicardia Atrial Ectópica/cirurgia , Feminino , Humanos , Pessoa de Meia-Idade , Resultado do Tratamento
8.
Europace ; 11(2): 158-63, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19010799

RESUMO

AIMS: An increasing body of evidence has demonstrated the essential role of inflammation in the genesis and maintenance of atrial fibrillation (AF). The aim of the present study was to investigate whether success or failure of electrical pulmonary vein isolation (PVI) in patients with AF is related with the presence of a pre-ablative inflammatory state as determined by known clinical parameters and conventional markers of inflammation including high-sensitivity C-reactive protein, white blood cell (WBC) count, and fibrinogen. METHODS AND RESULTS: Seventy-two patients with paroxysmal (64%) or persistent AF (36%) underwent successful electrical PVI. The mean duration of arrhythmia was 5.5 +/- 2.9 years. After a mean follow-up period of 12.5 +/- 5.7 months, 44 patients (61%) were in sinus rhythm. In univariate Cox proportional hazard regression analysis, hypertension, body mass index (BMI), left ventricular ejection fraction, left ventricular end-diastolic diameter, left atrial diameter (LAD), WBC count, and high-sensitivity C-reactive protein were significantly associated with AF recurrence (P < 0.05). In multivariate Cox proportional hazard regression analysis, hypertension [hazard ratio (HR) 3.127; 95% confidence interval (CI) 1.269-7.706, P = 0.013], LAD (HR 1.077; 95% CI 1.014-1.144, P = 0.015), and WBC count (HR 1.423; 95% CI 1.067-1.897, P = 0.016) were independent pre-ablative predictors of AF recurrence following PVI. CONCLUSION: Conventional markers of the inflammatory cascade such as WBC count and high-sensitivity C-reactive protein as well as elements of the metabolic syndrome such as hypertension and increased BMI were significantly associated with AF recurrence. The impact of a pre-ablative inflammatory state in the overall success rate of PVI needs further elucidation.


Assuntos
Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Proteína C-Reativa/metabolismo , Ablação por Cateter , Hipertensão/complicações , Inflamação/complicações , Veias Pulmonares/cirurgia , Feminino , Fibrinogênio/metabolismo , Seguimentos , Átrios do Coração/patologia , Ventrículos do Coração/patologia , Humanos , Inflamação/metabolismo , Inflamação/patologia , Contagem de Leucócitos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Recidiva , Análise de Regressão , Estudos Retrospectivos , Fatores de Risco , Disfunção Ventricular Esquerda/fisiopatologia
9.
Pacing Clin Electrophysiol ; 32(4): 500-5, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19335860

RESUMO

BACKGROUND: Previous studies have demonstrated a high incidence of atrial tachyarrhythmias (ATs) in patients with Brugada syndrome (BS). The present study aimed to investigate whether various 12-lead electrocardiogram (ECG) and electrophysiological parameters may help to differentiate subjects with a high probability to develop ATs. METHODS AND RESULTS: The clinical records of 38 individuals (31 males, age 44.4 +/- 13.9) with spontaneous (n = 15) or ajmaline-induced (n = 23) type 1 ECG pattern of BS were analyzed. During a mean follow-up period of 4.6 +/- 2.2 years, nine subjects suffered ATs (24%). Six subjects displayed paroxysmal atrial fibrillation and three typical atrial flutter. Among the studied 12-lead ECG parameters, subjects with ATs exhibited increased values of P-wave duration in lead II, P-wave dispersion, PR interval in leads II, QRS duration in leads II and V(2), Tpeak-end interval in lead II, and Tpeak-end dispersion of the 12 leads in relation to those without ATs (P < 0.05). Among the assessed electrophysiological parameters, atrial-His (AH) and His-ventricular (HV) intervals were significantly prolonged in subjects with ATs (P < 0.05). Multiple Cox proportional hazards analysis revealed that P-wave duration in lead II, P-wave dispersion, Tpeak-end in lead II, Tpeak-end dispersion of the 12 leads, as well as AH and HV intervals are independent predictors of ATs in subjects with BS (P < 0.05). Cut-off point analysis showed that an HV interval>or=56 ms displayed the highest predictive ability (P < 0.01). CONCLUSION: Our findings demonstrate that simple 12-lead ECG and electrophysiological parameters may easily be applied to identify high-risk subjects with BS ECG phenotype to develop ATs.


Assuntos
Fibrilação Atrial/diagnóstico , Síndrome de Brugada/diagnóstico , Eletrocardiografia/métodos , Taquicardia Atrial Ectópica/diagnóstico , Adulto , Feminino , Humanos , Masculino , Prognóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
10.
Circulation ; 115(24): 3057-63, 2007 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-17562956

RESUMO

BACKGROUND: Pulmonary vein (PV) isolation is a promising new treatment for atrial fibrillation (AF). We hypothesized that isolation of large areas around both ipsilateral PVs with verification of conduction block is more effective than the isolation of each individual PV. METHODS AND RESULTS: A total of 110 patients, 67 with paroxysmal AF and 43 with persistent AF, were randomly assigned to undergo either isolation of each individual PV or isolation of large areas around both ipsilateral PVs. The isolation of each individual PV was an electrophysiologically guided, ostial segmental ablation with a 64-pole basket catheter or a 20-pole circular mapping catheter (group I). Isolation of large areas was performed around the 2 ipsilateral veins with a nonfluoroscopic navigation system and a circular 20-pole mapping catheter for verification of conduction block (group II). In both groups, an irrigated-tip ablation catheter (25 to 35 W) was used to achieve complete isolation. Procedure and ablation times were longer in group II, whereas fluoroscopic time was significantly shorter (P < or = 0.001). After a follow-up period of 15+/-4 months, 27 patients in group I (49%) and 37 patients in group II (67%) remained free of symptoms of AF and had no AF or atrial flutter during repetitive Holter monitoring without antiarrhythmic drug treatment after a single procedure (P < or = 0.05). CONCLUSIONS: The rate of success was significantly higher and fluoroscopy times were significantly lower in the group with large isolation areas around both ipsilateral PVs than in those who underwent individual PV isolation.


Assuntos
Fibrilação Atrial/terapia , Ablação por Cateter/métodos , Veias Pulmonares , Idoso , Anticoagulantes/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Ablação por Cateter/efeitos adversos , Circulação Coronária , Intervalo Livre de Doença , Feminino , Seguimentos , Humanos , Imageamento Tridimensional , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Varfarina/uso terapêutico
11.
J Cardiovasc Electrophysiol ; 19(7): 748-52, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18179523

RESUMO

BACKGROUND: More extensive ablation strategies for the treatment of atrial fibrillation (AF) have increased success rates but are associated with new and sometimes serious complications. We describe a new complication after extensive radiofrequency (RF) ablation in the left atrium (LA) for persistent AF. METHODS AND RESULTS: Electroanatomic guided circumferential ablation around both ipsilateral pulmonary veins (PV) was performed with the endpoint of complete conduction block. When necessary, supplementary RF applications were added, including ablation of complex fractionated potentials and/or isolation of other thoracic veins and/or linear left atrial lesions. RF energy was delivered via an irrigated tip catheter with a maximum power of 30-35 W. Four out of 120 patients undergoing extensive RF ablation for persistent AF (including two patients with additional LA substrate modification) developed dyspnea, bilateral pulmonary edema, and signs of a systemic inflammatory response syndrome (SIRS) (rise in body temperature, leukocyte count, and C-reactive protein (CRP levels) 18-48 hours after the procedure. There were no signs of PV stenosis, focal lung injury, left ventricular dysfunction, circulatory failure, or infection. All patients had complete recovery with supportive therapy within 3-4 days after the onset of symptoms. CONCLUSIONS: Extensive LA radiofrequency ablation bears the risk of a severe pulmonary edema. Although the precise mechanism is elusive, clinical features point toward a systemic inflammatory response.


Assuntos
Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Edema Pulmonar/diagnóstico , Edema Pulmonar/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Edema Pulmonar/prevenção & controle
12.
J Cardiovasc Electrophysiol ; 18(1): 31-8, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17229297

RESUMO

INTRODUCTION: High-density three-dimensional (3D) mapping of the pulmonary vein (PV)-left atrial (LA) junction was performed to characterize spontaneous PV activity in humans. METHODS AND RESULTS: The activation patterns of ectopic beats and of the initial 2 seconds of atrial fibrillation (AF) from the PVs were analyzed using a 64-poles basket catheter. A focal mechanism was defined as a discrete site of early and centrifugal activation. Continuous activity was considered as an activation covering > or = 80% of the tachycardia beat-to-beat cycle length within the mapping field. In 35 patients, 123 spontaneous focal ectopic beats that did not induce AF and 95 that did induce AF were mapped. The mean coupling interval of ectopic discharges not inducing AF was 281 +/- 70 msec versus 236 +/- 90 msec for ectopies initiating AF (P < or = 0.01). The first ectopic activity of all 218 arrhythmogenic events showed exclusively a focal mechanism. During the 95 episodes of AF initiation, one or two ectopic beats from the PVs initiated AF in the LA in 39%, a stable focal tachycardia was recorded in 14%, continuous activity with important changes in cycle length (35 +/- 15 msec) suggestive of decremental or fibrillatory conduction was found in 18%, and in 29% the activation pattern could not be classified. No stable and sustained reentrant circuit could be identified by our mapping tool in the PV-LA junction. CONCLUSIONS: Arrhythmogenic activity from PVs in humans is predominantly due to discrete focal activity.


Assuntos
Fibrilação Atrial/diagnóstico , Técnicas Eletrofisiológicas Cardíacas/métodos , Sistema de Condução Cardíaco/fisiopatologia , Veias Pulmonares/fisiopatologia , Fibrilação Atrial/fisiopatologia , Cateterismo Cardíaco , Feminino , Seguimentos , Frequência Cardíaca/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Índice de Gravidade de Doença
13.
Ann Intern Med ; 142(12 Pt 1): 968-73, 2005 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-15968011

RESUMO

BACKGROUND: Loss of left ventricular capture in patients with cardiac resynchronization devices may account for worsening heart failure and can be difficult to diagnose without a programmer. OBJECTIVE: To determine whether distinct morphologic changes on the surface electrocardiogram indicate loss of left ventricular capture. DESIGN: After analysis of the R-S spike ratio in the 12-lead electrocardiogram during right ventricular and biventricular pacing in 10 patients, an algorithm to detect loss of left ventricular capture was developed. SETTING: University hospital. PATIENTS: 54 patients with a cardiac resynchronization device and underlying left bundle-branch block. MEASUREMENTS: Leads V1 and I of a 12-lead electrocardiogram were assessed after biventricular pacing was confirmed and after the device was programmed to right ventricular pacing only (simulating loss of left ventricular capture). RESULTS: The sensitivity of the algorithm to correctly identify loss of left ventricular capture was 94% (95% CI, 88.2% to 97.7%), and the specificity was 93% (CI, 86.3% to 95.8%). The likelihood ratio of a positive test result was 12.8 (CI, 6.443 to 23.310), and the likelihood ratio of a negative test result was 0.06 (CI, 0.024 to 0.137). LIMITATIONS: The algorithm was tested in patients in whom the right ventricular electrode was placed in the apex of the right ventricle only. CONCLUSION: Presence of biventricular capture--the prerequisite for successful cardiac resynchronization therapy--and loss of left ventricular capture can be accurately detected by an algorithm based on analysis of the R-S ratio on leads V1 and I of the surface electrocardiogram.


Assuntos
Algoritmos , Estimulação Cardíaca Artificial , Eletrocardiografia/métodos , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Disfunção Ventricular Esquerda/diagnóstico , Bloqueio de Ramo/fisiopatologia , Humanos , Sensibilidade e Especificidade , Disfunção Ventricular Esquerda/fisiopatologia
14.
J Am Heart Assoc ; 5(7)2016 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-27444509

RESUMO

BACKGROUND: There is limited evidence of long-term impact of right ventricular pacing on left ventricular (LV) systolic function in pacemaker recipients with preserved LV ejection fraction (LVEF). The objective of the study was to evaluate the outcome and echocardiographic course of baseline preserved LVEF in a large cohort of pacemaker recipients with respect to pacing indication and degree of right ventricular pacing. METHODS AND RESULTS: We enrolled 991 patients (73±10 years, 54% male) with baseline normal (>55%) LVEF (n=791) or mildly reduced (41-55%) LVEF (n=200) who had paired echocardiographic data on LV systolic function recorded at implantation and last follow-up. According to pacing indication, patients were divided into atrioventricular block group A (n=500) and sinus node disease group B (n=491). Main outcome measures were all-cause mortality and deterioration of LV function ≥2 LVEF categories at last follow-up. Patients were followed for an average of 44 months. Death from any cause occurred in 166 (17%), and deterioration of LV function ≥2 LVEF categories in 56 (6%) patients. There was no significant difference in outcome between group A and group B either in patients with normal LVEF or in those with mildly reduced LVEF. Mean percentage of right ventricular pacing was not predictive of outcome. CONCLUSIONS: In a large cohort of pacemaker recipients with predominantly normal LVEF, clinically relevant LV dysfunction develops rather infrequently. No significant difference in all-cause mortality and development of severe LV dysfunction is observed between patients with atrioventricular block and sinus node disease. Accordingly, de novo biventricular pacing cannot be recommended for patients with preserved LVEF.


Assuntos
Bloqueio Atrioventricular/terapia , Bradicardia/terapia , Estimulação Cardíaca Artificial , Sistema de Registros , Síndrome do Nó Sinusal/terapia , Volume Sistólico , Função Ventricular Esquerda , Idoso , Idoso de 80 Anos ou mais , Bloqueio Atrioventricular/complicações , Bloqueio Atrioventricular/fisiopatologia , Bradicardia/etiologia , Bradicardia/fisiopatologia , Causas de Morte , Estudos de Coortes , Progressão da Doença , Feminino , Ventrículos do Coração , Humanos , Masculino , Pessoa de Meia-Idade , Mortalidade , Marca-Passo Artificial , Estudos Retrospectivos , Síndrome do Nó Sinusal/complicações , Síndrome do Nó Sinusal/fisiopatologia , Sístole , Disfunção Ventricular Esquerda/fisiopatologia
15.
Circulation ; 108(20): 2484-90, 2003 Nov 18.
Artigo em Inglês | MEDLINE | ID: mdl-14581401

RESUMO

BACKGROUND: Ostial pulmonary vein (PV) isolation by radiofrequency (RF) catheter ablation can cure patients with atrial fibrillation (AF); however, this procedure carries the risk of PV stenosis. The aim of this study was to assess the feasibility of a new mapping and navigation technique using a multipolar basket catheter (BC) for PV isolation in patients with refractory AF and to analyze its safety with regard to PV stenosis at long-term follow-up. METHODS AND RESULTS: We studied 55 patients (mean age, 53+/-11 years; 40 male) with drug-refractory AF (paroxysmal, n=37; persistent, n=18). A 64-pole BC was placed transseptally into each of the accessible PVs. By use of a nonfluoroscopic navigation system, the ablation catheter was guided to the BC electrodes at the PV ostium, with earliest activation during sinus rhythm. RF was delivered by use of maximum settings of temperature at 50 degrees C and power at 30 W. The end point of the procedure was the complete elimination of all distal and fragmented ostial PV potentials. Of 165 targeted veins, 163 were successfully isolated with a mean RF duration of 720+/-301 seconds per vein. At 1-year follow-up, 62% of the patients were in sinus rhythm without antiarrhythmic drugs. Contrast-enhanced magnetic resonance angiography revealed 2 PV stenoses of >25% out of 165 treated vessels. CONCLUSIONS: The use of a multipolar BC allowed effective and safe PV isolation by combining 3D mapping and navigation. At 1-year follow-up, 62% of the patients were in sinus rhythm without antiarrhythmic drugs, and the incidence of relevant diameter reduction of the treated PVs was 1.2%.


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter , Veias Pulmonares/fisiopatologia , Veias Pulmonares/cirurgia , Mapeamento Potencial de Superfície Corporal/efeitos adversos , Mapeamento Potencial de Superfície Corporal/instrumentação , Ablação por Cateter/instrumentação , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Técnicas Eletrofisiológicas Cardíacas/métodos , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
17.
Int J Cardiol ; 164(1): 94-8, 2013 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-21726910

RESUMO

BACKGROUND: Obesity is a well established risk factor for atrial fibrillation (AF) development. Our purpose was to determine the impact of body mass index (BMI) on the safety and efficacy of radiofrequency catheter ablation of AF. METHODS: Two hundred and twenty-six consecutive patients with symptomatic, drug-refractory paroxysmal (59.3%) and persistent (40.7%) AF underwent wide circumferential electrical pulmonary vein isolation. Patients were classified according to BMI as normal (<25kg/m(2)); overweight (25 to 29.9kg/m(2)); and obese (≥30kg/m(2)). RESULTS: Patients with high BMI were younger and displayed a higher rate of hypertension, increased left atrial diameter, increased left ventricular end-diastolic and end-systolic diameters, and increased levels of several conventional markers of inflammation and oxidative stress including white blood cell count, fibrinogen, uric acid, alanine aminotransferase, and gamma-glutamyltransferase (p<0.05). After a mean follow-up period of 432.32±306.09days from the index procedure, AF recurrence rate was 34.9% for normal weight, 46.2% for overweight, and 46.2% for obese patients (p: 0.258). Subjects classified above the 50th percentile for BMI displayed a trend toward a higher AF recurrence rate (p: 0.08). In univariate Cox regression survival analysis, BMI was not predictive of AF recurrence. Radiation exposure was significantly higher in overweight and obese patients in relation to normal weight patients (p: 0.003). No significant differences regarding major complications were observed among BMI groups. CONCLUSIONS: In this study population, BMI was not an independent predictor of AF recurrence following left atrial catheter ablation.


Assuntos
Fibrilação Atrial/cirurgia , Índice de Massa Corporal , Ablação por Cateter , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
18.
Heart Rhythm ; 9(2): 189-96, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21920484

RESUMO

BACKGROUND: Experimental data suggest that use of cryoablation in pulmonary vein isolation (PVI) is associated with less cell damage and less thrombus formation compared to radiofrequency (RF) energy. OBJECTIVE: The purpose of this study was to test the hypothesis that cryoablation significantly reduces markers of cell damage, platelet activation, and inflammation in patients undergoing PVI for treatment of atrial fibrillation (AF). METHODS: Sixty patients with symptomatic drug-resistant AF (age 56 ± 9 years, 48 males, 38 with paroxysmal AF) were randomly assigned to undergo PVI using either an open irrigated-tip RF catheter or a cryoballoon. Markers of cell damage (high-sensitive troponin T [hs-TnT], microparticles), platelet activation (platelet reactivity by aggregometry, expression of platelet surface proteins P-selectin and activated glycoprotein [GP] IIb/IIIa), and inflammatory response (high-sensitive C-reactive protein [hs-CRP]) were determined before and up to 48 hours after the procedure. RESULTS: PVI resulted in a significant rise in hs-TnT, microparticles, markers of platelet activation, and hs-CRP over time, with distinct temporal patterns for each parameter. However, after Bonferroni correction for repeated measurements, no significant differences were noted in these parameters between patients treated with cryoablation or RF energy. Procedural time was significantly shorter in patients treated with cryoballoon (177 ± 30 minutes vs 200 ± 46 minutes, P = .03), with no differences in fluoroscopic time, periprocedural complications, or success rate. CONCLUSION: Cryoablation and RF energy result in a comparable rise of markers of cell damage, platelet activation and inflammatory response. The data do not support the concept of an improved safety profile for cryoablation in PVI.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Inflamação/fisiopatologia , Ativação Plaquetária/fisiologia , Veias Pulmonares/cirurgia , Trombose/fisiopatologia , Idoso , Proteína C-Reativa/análise , Ablação por Cateter/métodos , Micropartículas Derivadas de Células , Criocirurgia/métodos , Feminino , Citometria de Fluxo , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Troponina T/sangue
19.
Heart Rhythm ; 8(6): 874-8, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21315837

RESUMO

BACKGROUND: Previous studies have demonstrated an overlap between the arrhythmogenic right ventricular cardiomyopathy/dysplasia (ARVC/D) and Brugada syndrome (BS). Conduction delay in the right ventricle has been demonstrated in both entities. OBJECTIVE: This study investigated specific ARVC/D electrocardiographic (ECG) markers in subjects with spontaneous or drug-induced type 1 ECG pattern of BS. METHODS: The study population consisted of 47 apparently healthy individuals (38 men, mean age 44.1 ± 13.3 years) with spontaneous (n = 17) or drug-induced (n = 30) type 1 ECG phenotype of BS. The clinical records of these individuals were retrospectively analyzed. RESULTS: Fifteen subjects (31.9%) were symptomatic, with a history of syncope. A family history of BS or sudden cardiac death was reported in 10 (21.3%) and 8 (17.0%) cases, respectively. Epsilon-like waves in leads V1-V3 were observed in 6 subjects (12.7%). Epsilon-like waves were seen in spontaneous type 1 ECGs in 2 cases and after sodium channel blocking test in 4 cases. In baseline ECGs, localized prolongation (>110 ms) of the QRS complex in leads V1-V3, QRS duration ratio in (V1+V2+V3)/(V4+V5+V6) ≥ 1.2, and prolonged S wave upstroke (>55 ms) in leads V1-V3 were seen in 48.8%, 29.8%, and 40.4% of subjects, respectively. Epsilon-like waves and delayed S wave upstroke were more commonly observed in subjects with family history of BS (P = .014 and P = .038, respectively). CONCLUSION: Specific ECG markers that reflect ventricular conduction delay in ARVC/D are commonly observed in subjects with spontaneous or drug-induced type 1 ECG pattern of BS as well. These depolarization abnormalities may be related to subtle underlying structural abnormalities.


Assuntos
Síndrome de Brugada/fisiopatologia , Eletrocardiografia/efeitos dos fármacos , Sistema de Condução Cardíaco/fisiopatologia , Ventrículos do Coração/inervação , Bloqueadores dos Canais de Sódio/efeitos adversos , Função Ventricular Direita/fisiologia , Adulto , Síndrome de Brugada/induzido quimicamente , Síndrome de Brugada/diagnóstico , Feminino , Seguimentos , Sistema de Condução Cardíaco/efeitos dos fármacos , Ventrículos do Coração/efeitos dos fármacos , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Estudos Retrospectivos , Função Ventricular Direita/efeitos dos fármacos
20.
Int J Cardiol ; 145(2): 342-345, 2010 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-20051302

RESUMO

Recent data point to a high incidence of early repolarization abnormalities among patients with idiopathic ventricular fibrillation (IVF). ECG data from 11 patients with idiopathic IVF were evaluated for the presence of initial (slurring or notching of the ascending limb of the R-wave that resembles a "pseudo" delta-wave) and terminal (slurring or notching of the descending limb of the R-wave resembling the early repolarization pattern) QRS complex abnormalities in at least two contiguous leads. The control group comprised 101 age- and gender-matched healthy individuals without structural heart disease in whom the presence of an accessory pathway was excluded during electrophysiological study. Initial QRS complex abnormalities in the setting of a normal PR interval were more frequent in subjects with IVF than in control population (36.4% vs. 8.9%, p=0.023). Although not statistically significant, an early repolarization pattern was also more common among patients with IVF (27.3% vs. 12.9%, p=0.192). Among patients with IVF, there is an increased prevalence of initial and terminal QRS complex abnormalities.


Assuntos
Eletrocardiografia/métodos , Sistema de Condução Cardíaco/fisiopatologia , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/fisiopatologia , Adulto , Feminino , Sistema de Condução Cardíaco/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fibrilação Ventricular/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA