Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Clin Chem Lab Med ; 58(10): 1713-1723, 2020 09 25.
Artigo em Inglês | MEDLINE | ID: mdl-31584871

RESUMO

Background Eltrombopag is a thrombopoietin receptor agonist used for the treatment of thrombocytopenic conditions. It can cause pH-dependent discoloration of plasma/serum. Eltrombopag is potentially hepatotoxic. It can affect the assessment of hyperbilirubinemia because of its (i) absorbance at ~450 nm (bilirubin), (ii) absorbance at ~550 nm (diazo-bilirubin) and (iii) it can cause yellowish discoloration of the eyes at normal circulating bilirubin levels. Methods We collected 66 samples from patients on a range of eltrombopag dosages up to 150 mg daily. Bilirubin was measured using multiple routine spectrophotometric analyzers, the Doumas reference method and high-performance liquid chromatography (HPLC). Plasma/serum eltrombopag concentrations were determined using liquid chromatography tandem mass spectrometry (LC-MS/MS). Spike-in and admixture experiments delineated the effects of eltrombopag and its metabolites. Results Forty-nine of 52 samples from patients on ≥50 mg daily eltrombopag therapy showed significantly discrepant inter-analyzer total bilirubin results, a difference up to 64 µmol/L (3.7 mg/dL). In one sample, total bilirubin varied from 8 to 65 µmol/L (0.4-3.8 mg/dL) by different routine analyzers, with direct bilirubin ≤4 µmol/L (0.2 mg/dL). There was a positive correlation between total bilirubin difference and plasma eltrombopag concentration (r = 0.679), and spike-in experiments demonstrated that Beckman AU and Doumas reference methods were susceptible to positive interference. HPLC can quantify bilirubin after separating eltrombopag, and results suggest different analyzers are affected to varying degrees by eltrombopag and its metabolites. Conclusions Eltrombopag and its metabolites can cause positive interference to the spectrophotometric measurements of total bilirubin. Accurate measurements of total bilirubin may improve our understanding of the prevalence of hyperbilirubinemia in patients on eltrombopag therapy.


Assuntos
Benzoatos/uso terapêutico , Bilirrubina/sangue , Cromatografia Líquida de Alta Pressão/métodos , Hidrazinas/uso terapêutico , Pirazóis/uso terapêutico , Espectrometria de Massas em Tandem/métodos , Idoso , Benzoatos/administração & dosagem , Benzoatos/sangue , Benzoatos/farmacocinética , Relação Dose-Resposta a Droga , Feminino , Humanos , Hidrazinas/administração & dosagem , Hidrazinas/sangue , Hidrazinas/farmacocinética , Pirazóis/administração & dosagem , Pirazóis/sangue , Pirazóis/farmacocinética
2.
Clin Chem Lab Med ; 55(4): 522-529, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-27701133

RESUMO

BACKGROUND: Serum dihydrotestosterone (DHT) is an important analyte for the clinical assessment of disorders of sex development. It is also reportedly a difficult analyte to measure. Currently, there are significant gaps in the standardisation of this analyte, including no external quality assurance (EQA) program available worldwide to allow for peer review performance of DHT. We therefore proposed to establish a pilot EQA program for serum DHT. METHODS: DHT was assessed in the 2015 Royal College of Pathologists of Australasia Quality Assurance Programs' Endocrine program material. The material's target (i.e. "true") values were established using a measurement procedure based on isotope dilution gas chromatography (GC) tandem mass spectrometry (MS/MS). DHT calibrator values were based on weighed values of pure DHT material (>97.5% purity) from Sigma. The allowable limits of performance (ALP) were established as ±0.1 up to 0.5 nmol/L and ±15% for targets >0.5 nmol/L. RESULTS: Target values for the six levels of RCPAQAP material for DHT ranged from 0.02 to 0.43 nmol/L (0.01-0.12 ng/mL). The material demonstrated linearity across the six levels. There were seven participating laboratories for this pilot study. Results of the liquid chromatography (LC) MS/MS methods were within the ALP; whereas the results from the immunoassay methods were consistently higher than the target values and outside the ALP. CONCLUSIONS: This report provides the first peer comparison of serum DHT measured by mass spectrometry (MS) and immunoassay laboratories. Establishment of this program provides one of the pillars to achieve method harmonisation. This supports accurate clinical decisions where DHT measurement is required.


Assuntos
Di-Hidrotestosterona/sangue , Cromatografia Gasosa-Espectrometria de Massas/normas , Imunoensaio/normas , Calibragem , Cromatografia Líquida/normas , Ensaio de Imunoadsorção Enzimática/normas , Humanos , Técnicas de Diluição do Indicador/normas , Ensaio de Proficiência Laboratorial , Projetos Piloto , Controle de Qualidade , Radioimunoensaio/normas , Espectrometria de Massas em Tandem/normas
3.
Artigo em Inglês | MEDLINE | ID: mdl-39293160

RESUMO

Detection of ß-2 transferrin in body fluid could help identify cerebrospinal fluid (CSF) leakage. The most common method, isoelectric focusing, was qualitative and could not provide detailed N-glycan structural information. We presented an alternative method using top-down liquid chromatography-time of flight mass spectrometry (LC-TOF MS). After immunoaffinity enrichment, fluid transferrin glycoforms were analyzed by a high-resolution LC-TOF MS, and the N-glycan structure predicted by accurate mass. The performance was validated with imprecision at 15%, with a cut-off of 0.04 for ß-2 transferrin to tetrasialotransferrin ratio to confirm the presence of CSF in fluid samples.

4.
Int J Dev Biol ; 54(8-9): 1355-60, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20563993

RESUMO

During early embryonic development, the retinoic acid signaling pathway coordinates with other signaling pathways to regulate body axis patterning and organogenesis. The production of retinoic acid requires two enzymatic reactions, the first of which is the oxidization of vitamin A (all-trans-retinol) to all-trans -retinal, mediated in part by the short-chain dehydrogenase/reductase. Through DNA microarrays, we have identified a gene in Xenopus laevis which shares a high sequence similarity to human short-chain dehydrogenase/reductase member 3. We therefore annotated the gene Xenopus short-chain dehydrogenase/reductase 3 (dhrs3). Expression of dhrs3 was detected by whole mount in situ hybridization in the dorsal blastopore lip and axial mesoderm region in gastrula embryos. During neurulation, dhrs3 transcripts were found in the notochord and neural ectoderm. Strong expression of dhrs3 was mainly detected in the brain, spinal cord and pronephros region in tailbud and tadpole stages. Temporal expression tested by RT-PCR indicated that dhrs3 was activated at the onset of gastrulation, and remained highly expressed at later stages of embryonic development. The distinct and highly regulated spatial and temporal expression of dhrs3 highlights the complexity of retinoic acid regulation.


Assuntos
Oxirredutases do Álcool/genética , Gástrula/metabolismo , Regulação da Expressão Gênica no Desenvolvimento , Proteínas de Xenopus/genética , Xenopus laevis/genética , Oxirredutases do Álcool/classificação , Oxirredutases do Álcool/metabolismo , Sequência de Aminoácidos , Animais , Encéfalo/embriologia , Encéfalo/metabolismo , Gástrula/embriologia , Gástrula/enzimologia , Gastrulação/genética , Perfilação da Expressão Gênica , Hibridização In Situ , Larva/genética , Dados de Sequência Molecular , Análise de Sequência com Séries de Oligonucleotídeos , Oxirredutases , Filogenia , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Homologia de Sequência de Aminoácidos , Medula Espinal/embriologia , Medula Espinal/metabolismo , Vitamina A/metabolismo , Proteínas de Xenopus/classificação , Proteínas de Xenopus/metabolismo , Xenopus laevis/embriologia
5.
Clin Chem ; 53(7): 1254-63, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17510303

RESUMO

BACKGROUND: The use of MALDI-TOF mass spectrometry (MS) in quantitative glycan profiling has not been reported. In this study, we attempted to establish a high-throughput quantitative assay for profiling serum N-glycome, and we applied the new assay to identifying serum N-glycans for diagnosis of liver fibrosis and cirrhosis. METHODS: N-glycans from whole serum proteins in 2 microL serum were released by enzymatic digestion, cleaned up by hydrophilic chromatography, and subsequently quantitatively profiled with a linear MALDI-TOF MS system, which was originally designed for quantitative proteomic profiling. Serum N-glycome profiles from 46 patients with chronic hepatitis B infection and with different degrees of liver fibrosis were examined. RESULTS: The intra- and interassay CVs of peak intensities of the standard N-glycans were <8% and <17%, respectively. When the assay was applied to the analysis of serum N-glycome profiles, 17 peaks were found to be potential biomarkers for detection of liver fibrosis/cirrhosis. Linear regression analysis revealed that 4 peaks of 1341.5, 1829.7, 1933.3, and 2130.3 m/z (all P <0.005) had complementary value in detecting liver fibrosis and included them, but not any serological markers, in the diagnostic model. Leave-one-out cross-validation showed the diagnostic model could identify significant fibrosis (Ishak score > or = 3) and cirrhosis (Ishak score > or = 5), both at 85% accuracy. CONCLUSION: This is the first study to illustrate the quantitative aspect of MALDI-TOF MS in N-glycome profiling and the first study to reveal the potential value of the serum N-glycan profile for identifying liver fibrosis.


Assuntos
Cirrose Hepática/sangue , Polissacarídeos/sangue , Biomarcadores/sangue , Estudos de Viabilidade , Feminino , Hepatite C Crônica/complicações , Humanos , Modelos Lineares , Cirrose Hepática/diagnóstico , Cirrose Hepática/etiologia , Masculino , Pessoa de Meia-Idade , Análise Serial de Proteínas/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Soro , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA