Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 35(5): 994-1004, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38501333

RESUMO

INTRODUCTION: When ventricular tachycardia (VT) recurs after standard RF ablation (sRFA) some patients benefit from repeat sRFA, whereas others warrant advanced methods such as intramural needle ablation (INA). Our objectives are to assess the utility of repeat sRFA and to clarify the benefit of INA when repeat sRFA fails in patients with VT due to structural heart disease. METHODS: In consecutive patients who were prospectively enrolled in a study for INA for recurrent sustained monomorphic VT despite sRFA, repeat sRFA was considered first. INA was performed during the same procedure if repeat sRFA failed or no targets for sRFA were identified. RESULTS: Of 85 patients enrolled, acute success with repeat sRFA was achieved in 30 patients (35%), and during the 6-month follow-up, 87% (20/23) were free of VT hospitalization, 78% were free of any VT, and 7 were lost to follow-up. INA was performed in 55 patients (65%) after sRFA failed, or no endocardial targets were found abolished or modified inducible VT in 35/55 patients (64%). During follow-up, 72% (39/54) were free of VT hospitalization, 41% were free of any VT, and 1 was lost to follow-up. Overall, 59 out of 77 (77%) patients were free of hospitalization and 52% were free of any VT. Septal-origin VTs were more likely to need INA, whereas RV and papillary muscle VTs were less likely to require INA. CONCLUSIONS: Repeat sRFA was beneficial in 23% (18/77) of patients with recurrent sustained VT who were referred for INA. The availability of INA increased favorable outcomes to 52%.


Assuntos
Ablação por Cateter , Cicatriz , Recidiva , Reoperação , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Estudos Prospectivos , Ablação por Cateter/efeitos adversos , Cicatriz/fisiopatologia , Cicatriz/diagnóstico , Cicatriz/cirurgia , Cicatriz/etiologia , Fatores de Tempo , Potenciais de Ação , Agulhas , Frequência Cardíaca , Fatores de Risco , Resultado do Tratamento
2.
Europace ; 26(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38367008

RESUMO

AIMS: Failure of radiofrequency (RF) ablation of ventricular arrhythmias is often due to inadequate lesion size. Irrigated RF ablation with half-normal saline (HNS) has the potential to increase lesion size and reduce sodium delivery to the patient if the same volume of RF irrigant were used for normal saline (NS) and HNS but could increase risks related to steam pops and lesion size. This study aims to assess periprocedural complications and acute ablation outcome of ventricular arrhythmias ablation with HNS. METHODS AND RESULTS: Prospective assessment of outcomes was performed in 1024 endocardial and/or epicardial RF ablation procedures in 935 consecutive patients (median age 64 years, 71.2% men, 73.4% cardiomyopathy, 47.2% sustained ventricular tachycardia). Half-normal saline was selected at the discretion of the treating physician. Radiofrequency ablation power was generally titrated to a ≤15â€…Ω impedance fall with intracardiac echocardiography monitoring. Half-normal saline was used in 900 (87.9%) and NS in 124 (12.1%) procedures. Any adverse event within 30 days occurred in 13.0% of patients treated with HNS RF ablation including 4 (0.4%) strokes/transient ischaemic attacks and 34 (3.8%) pericardial effusions requiring treatment (mostly related to epicardial access). Two steam pops with perforation required surgical repair (0.2%). Patients who received NS irrigation had less severe disease and arrhythmias. In multivariable models, adverse events and acute success of the procedure were not related to the type of irrigation. CONCLUSION: Half-normal saline irrigation RF ablation with power guided by impedance fall and intracardiac echocardiography has an acceptable rate of complications and acute ablation success while administering half of the saline load expected for NS irrigation.


Assuntos
Ablação por Cateter , Ablação por Radiofrequência , Taquicardia Ventricular , Masculino , Humanos , Pessoa de Meia-Idade , Feminino , Solução Salina/efeitos adversos , Vapor , Estudos Prospectivos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Taquicardia Ventricular/cirurgia , Irrigação Terapêutica/efeitos adversos
3.
J Cardiovasc Electrophysiol ; 34(1): 135-141, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36300705

RESUMO

INTRODUCTION: BNP elevation in patients with AF is observed in the absence of heart failure; however, prior mechanistic studies have not included direct left atrial pressure measurements. This study sought to understand how emptying function of the left atrial appendage (LAA) and LAA dimension contributes to brain-natriuretic peptide elevations (BNP) in atrial fibrillation (AF) accounting for left atrial pressure (LAP). METHODS: 132 patients referredfor left atrial appendage occlusion (LAAO) were prospectively enrolled in this study. BNP levels and LAP were measured just before LAAO. Statistical analysis considered BNP, rhythm at time of procedure, LAP, LAA morphology, LAA size (ostial diameter, depth, volume), LAA emptying velocity, CHADS2-VASc score, body mass index (BMI), left ventricular ejection fraction (LVEF), estimated glomerular filtration rate (eGFR), and obstructive sleep apnea (OSA) diagnosis as covariates. RESULTS: Bivariate statistical analysis demonstrated positive associations with age, LAA ostial diameter, depth, and volume, LAP, AF status at time of measurement, OSA, and CHADS2-VASc score. BNP was negatively associated with LVEF, eGFR, LAA emptying velocity and BMI. With multivariate logistic regression including LAP as covariate, significant relationships between BNP and AF/AFL(OR 1.99 [1.03, 3.85]), LAP (OR 1.13 [1.06, 1.20]), LAA diameter (OR 1.14 [1.03, 1.27]), LAA depth (OR 1.14 [1.07, 1.22]), and LAA emptying velocity (OR 0.97 [0.96,0.99]) were observed; however, no significant associations were seen with LAA morphology or CHADS2-VASc score. CONCLUSIONS: BNP elevations in AF are associated with LAA size and function, but not CHADS2-VASc score or appendage morphology after accounting for changes in LAP.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Peptídeo Natriurético Encefálico , Humanos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/patologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/metabolismo , Ecocardiografia Transesofagiana , Peptídeo Natriurético Encefálico/sangue , Peptídeo Natriurético Encefálico/química , Apneia Obstrutiva do Sono/diagnóstico , Volume Sistólico , Função Ventricular Esquerda
4.
J Cardiovasc Electrophysiol ; 33(8): 1655-1664, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35598280

RESUMO

INTRODUCTION: To target posterior wall isolation (PWI) in atrial fibrillation (AF) ablation, diffuse ablation theoretically confers a lower risk of conduction recovery compared to box set. We sought to assess the safety and efficacy of diffuse PWI with low-flow, medium-power, and short-duration (LF-MPSD) ablation, and evaluate the durability of pulmonary vein isolation (PVI) and PWI among patients undergoing repeat ablations. METHODS: We retrospectively studied patients undergoing LF-MPSD ablation for AF (PVI + diffuse PWI) between August 2017 and December 2019. Clinical characteristics were collected. Kaplan-Meier survival analysis was performed to study AF/atrial flutter (AFL) recurrence. Ablation data were analyzed in patients who underwent a repeat AF/AFL ablation. RESULTS: Of the 463 patients undergoing LF-MPSD AF ablation (PVI alone, or PVI + diffuse PWI), 137 patients had PVI + diffuse PWI. Acute PWI with complete electrocardiogram elimination was achieved in 134 (97.8%) patients. Among the 126 patients with consistent follow-up, 38 (30.2%) patients had AF/AFL recurrence during a median duration of 14 months. Eighteen patients underwent a repeat AF/AFL ablation after PVI + diffuse PWI, and 16 (88.9%) patients had durable PVI, in contrast to 10 of 45 (23.9%) patients who had redo ablation after LF-MPSD PVI alone. Seven patients (38.9%) had durable PWI, while 11 patients had partial electrical recovery at the posterior wall. The median percentage of area without electrical activity at the posterior wall was 70.7%. Conduction block across the posterior wall was maintained in 16 (88.9%) patients. CONCLUSION: There was a high rate of PVI durability in patients undergoing diffuse PWI and PVI. Partial posterior wall electrical recovery was common but conduction block across the posterior wall was maintained in most patients.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etiologia , Fibrilação Atrial/cirurgia , Flutter Atrial/diagnóstico , Flutter Atrial/etiologia , Flutter Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
5.
J Cardiovasc Electrophysiol ; 32(4): 1044-1052, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33512055

RESUMO

BACKGROUND: Nonchicken wing left atrial appendage (LAA) morphology is associated with higher risk for stroke in patients with atrial fibrillation (AF) than chicken wing (CW) morphology. OBJECTIVE: Assess whether LAA morphology predicts the formation of LAA thrombus independent of age, sex, presenting rhythm, left ventricular ejection fraction (LVEF), or anticoagulant use. METHODS: A cross-sectional analysis was performed on patients prospectively enrolled in the Vanderbilt LAA Registry or presenting for transesophageal echocardiogram (TEE) between January 1, 2015, and November 1, 2017 (n = 306). Two physicians independently reviewed TEEs interpreted as having LAA thrombus. Determination of LAA morphology, ejection velocity, and presence of thrombus (n = 102) were based on 0°, 45°, 90°, and 135° TEE views. The control cohort (n = 204) included consecutive AF patients undergoing TEE without LAA thrombus. RESULTS: LAA morphology in patients with LAA thrombus was: 35% windsock, 47% broccoli, and 12% CW. Windsock (odds ratio [OR], 4.0; 95% confidence interval [CI]: 1.7-9.3, p = .001) and broccoli (OR, 6.6; 95% CI: 2.6-16.6; p < .001) morphology were higher risk for thrombus compared to CW. Female sex predicted higher-odds for LAA thrombus (OR, 2.6; 95% CI: 1.4-4.8; p = .002) as did LAA-EV < 20 cm/s (OR, 11.12; 95% CI: 5.6-22.1). Anticoagulation use (OR, 0.5; 95% CI: 0.3-0.9; p = .03) and higher LVEF (OR, 0.95; 95% CI: 0.93-0.98; p < .001) were associated with lower risk. In patients with a CW morphology who had LAA thrombus, 4 of the 7 had an LAA-EV < 20 cm/s and acute systolic heart failure with LVEF < 30% or active malignancy. In multivariable linear regression analysis controlling for presenting rhythm, anticoagulant use, age, sex, and LVEF, CW morphology appears relatively protective from LAA thrombus (p = .001). CONCLUSION: CW LAA morphology appears relatively protective against the formation of LAA thrombus.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Trombose , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico por imagem , Estudos Transversais , Ecocardiografia Transesofagiana , Feminino , Humanos , Volume Sistólico , Trombose/diagnóstico por imagem , Função Ventricular Esquerda
6.
J Cardiovasc Electrophysiol ; 30(10): 1994-2001, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31328298

RESUMO

INTRODUCTION: Subclinical atrial fibrillation (AF), in the form of cardiac implantable device-detected atrial high rate episodes (AHREs), has been associated with increased thromboembolism. An implantable cardioverter-defibrillator (ICD) lead with a floating atrial dipole may permit a single lead (DX) ICD system to detect AHREs. We sought to assess the utility of the DX ICD system for subclinical AF detection in patients, with a prospective multicenter, cohort-controlled trial. METHODS AND RESULTS: One hundred fifty patients without prior history of AF (age 59 ± 13 years; 108 [72%] male) were enrolled into the DX cohort and implanted with a Biotronik DX ICD system at eight centers. Age-, sex-, and left ventricular ejection fraction-matched single- and dual-chamber ICD cohorts were derived from a Cornell database and from the IMPACT trial, respectively. The primary endpoint were AHRE detection at 12 months. During median 12 months follow-up, AHREs were detected in 19 (13%) patients in the DX, 8 (5.3%) in the single-chamber, and 19 (13%) in the dual-chamber cohorts. The rate of AHRE detection was significantly higher in the DX cohort compared to the single-chamber cohort (P = .026), but not significantly different compared to the dual-chamber cohort. There were no inappropriate ICD therapies in the DX cohort. At 12 months, only 3.0% of patients in the DX cohort had sensed atrial amplitudes less than 1.0 mV. CONCLUSION: Use of a DX ICD lead allows subclinical AF detection with a single lead DX system that is superior to that of a conventional single-chamber ICD system.


Assuntos
Fibrilação Atrial/diagnóstico , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Técnicas Eletrofisiológicas Cardíacas/instrumentação , Tecnologia de Sensoriamento Remoto/instrumentação , Potenciais de Ação , Adulto , Idoso , Doenças Assintomáticas , Fibrilação Atrial/fisiopatologia , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Tempo , Estados Unidos
7.
Pacing Clin Electrophysiol ; 42(7): 965-969, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31045260

RESUMO

BACKGROUND: Boston Scientific (Marlborough, MA, USA) implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy defibrillators (CRT-Ds) manufactured between 2008 and 2014 are potentially subject to premature battery depletion through a low-voltage capacitor malfunction occurring as a result of hydrogen buildup within the device. Although some of these devices are currently under advisory, other devices manufactured during this timeframe carry a lower risk of the same malfunction. These same devices are known to have superior longevity in general, and the overall mean lifespan of the devices remains long. METHODS: All patients implanted or followed at our two centers who experienced premature battery depletion and had a Boston Scientific ICD or CRT-D potentially at risk for low-voltage capacitor malfunction were studied retrospectively. RESULTS: Nineteen out of 838 patients (2.3%) with devices potentially at risk have had premature battery depletion: 5.7% of those under advisory and 1.1% of those not under advisory. None of our patients had compromised therapy, and all had >27 days of projected battery longevity remaining. CONCLUSIONS: Undetected premature battery depletion in this population of ICDs has the potential to expose a patient to an interval of time where the device is unable to provide therapy. However, with enrollment in remote monitoring, regular follow-up, and attention to audible alerts, the risk of therapy loss due to low-voltage state can be effectively mitigated. For these reasons, prophylactic generator replacement is not recommended.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Fontes de Energia Elétrica , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Estudos Retrospectivos
13.
J Cardiovasc Electrophysiol ; 27(1): 120-4, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26511459

RESUMO

We present three cases within 11 months at a single institution of sustained VT that fell below the programmed detection rate of the patients' implantable cardioverter-defibrillators (ICDs), two of which continued until converting to an agonal VF that did not meet criteria for detection, and a third case that could not be successfully defibrillated after a prolonged period of VT. These episodes may be under-recognized due to the dependence of device diagnostic storage on programming and the post-mortem effort that is often required to review these events. Some patients, likely those with the most advanced heart failure, may not tolerate sustained ventricular tachycardia (VT) and may even die from ventricular arrhythmias without ever having a rhythm that meets detection criteria in a ventricular fibrillation (VF) zone.


Assuntos
Morte Súbita Cardíaca/etiologia , Cardioversão Elétrica/instrumentação , Taquicardia Ventricular/terapia , Idoso , Causas de Morte , Desfibriladores Implantáveis , Eletrocardiografia , Evolução Fatal , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia Ventricular/complicações , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Falha de Tratamento
14.
J Cardiovasc Electrophysiol ; 26(10): 1111-6, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26222980

RESUMO

INTRODUCTION: Cardiac implantable electronic device (CIED) infections are potentially preventable complications associated with high morbidity, mortality, and cost. A recently developed bio-absorbable antibacterial envelope (TYRX™-A) might prevent CIED infections in high-risk subjects. However, data regarding safety and efficacy have not been published. METHODS AND RESULTS: In a single-center retrospective cohort study, we compared the prevalence of CIED infections among subjects with ≥2 risk factors treated with the TYRX™-A envelope (N = 135), the nonabsorbable TYRX™ envelope (N = 353), and controls who did not receive an envelope (N = 636). Infection was ascertained by individual chart review. The mean (95% confidence interval) number of risk factors was 3.08 (2.84-3.32) for TYRX™-A, 3.20 (3.07-3.34) for TYRX™, and 3.09 (2.99-3.20) for controls, P = 0.3. After a minimum 300 days follow-up, the prevalence of CIED infection was 0 (0%) for TYRX™-A, 1 (0.3%) for TYRX™, and 20 (3.1%) for controls (P = 1 for TYRX™-A vs. TYRX™, P = 0.03 for TYRX™-A vs. controls, and P = 0.002 for TYRX™ vs. controls). In a propensity score-matched cohort of 316 recipients of either envelope and 316 controls, the prevalence of infection was 0 (0%) and 9 (2.8%), respectively, P = 0.004. When limited to 122 TYRX™-A recipients and 122 propensity-matched controls, the prevalence of CIED infections was 0 (0%) and 5 (4.1%), respectively, P = 0.024. CONCLUSIONS: Among high-risk subjects, the TYRX™-A bio-absorbable envelope was associated with a very low prevalence of CIED related infections that was comparable to that seen with the nonabsorbable envelope.


Assuntos
Antibacterianos/administração & dosagem , Desfibriladores Implantáveis/estatística & dados numéricos , Implantes de Medicamento/administração & dosagem , Marca-Passo Artificial/estatística & dados numéricos , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/prevenção & controle , Implantes Absorvíveis/estatística & dados numéricos , Idoso , Causalidade , Estudos de Coortes , Preparações de Ação Retardada/administração & dosagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Infecções Relacionadas à Prótese/diagnóstico , Estudos Retrospectivos , Fatores de Risco , Distribuição por Sexo , Taxa de Sobrevida , Tennessee/epidemiologia , Resultado do Tratamento
15.
Artigo em Inglês | MEDLINE | ID: mdl-39297837

RESUMO

BACKGROUND: Termination of ventricular tachycardia (VT) by a pacing stimulus that does not generate a QRS complex (termination without global propagation [TWGP]) can be a marker for a critical re-entry circuit isthmus. However, the electrophysiologic and anatomic features of these sites and their relation to VT substrate defined by 3-dimensional electroanatomical maps (3D-EAM) remain unknown. OBJECTIVES: This retrospective study aimed to characterize TWGP sites and their relation to VT substrate identified by 3D-EAM. METHODS: A total of 632 consecutive cases of catheter ablation for scar-related VT at 2 University medical centers were reviewed to identify TWGP. RESULTS: TWGP was observed 12 times at 11 different sites in 10 patients (5 ischemic cardiomyopathy). The TWGP stimulus fell immediately before or synchronous with the QRS in all cases, and evidence of local capture despite absence of a QRS complex was observed 6 times. In 5 sites, pacing after VT termination produced a QRS different than the VT. Four sites were in dense scar areas (<0.1 mV), and 6 in abnormal low voltage zone (0.1-1.5 mV). Additional mapping or ablation that abolished VT were consistent with the TWGP site being in a VT isthmus. A substrate marker for VT of late potentials, evoked delayed potentials, or slow conduction was present at 6 of 11 TWGP sites. CONCLUSIONS: TWGP may be a marker for detecting a re-entry circuit isthmus that has escaped detection based on electrogram or pace mapping-based substrate mapping.

16.
Artigo em Inglês | MEDLINE | ID: mdl-39480388

RESUMO

BACKGROUND: Patients with ventricular tachycardia (VT) frequently present in unstable VT and are subject to urgent/high-risk ablation procedures. Clinical predictors of prolonged hospitalization and mortality are needed for optimal management of these patients. OBJECTIVES: This study seeks to identify factors associated with prolonged hospitalization and mortality in emergent unplanned VT ablation procedures. METHODS: Fifty consecutive patients hospitalized emergently for VT with structural heart disease who underwent catheter ablation were prospectively followed up for outcomes and complications. RESULTS: Of the 50 patients (mean ± SD age 67.6 ± 12.8 years), 86.0% were male, 62.0% had ischemic cardiomyopathy, and their median left ventricular ejection fraction was 28.5%. Hospital stay <7 days (median 3 days) occurred in 28 (56.0%) patients (Group 1) and >7 days (median 10 days) or death <7 days occurred in 22 (44.0%) patients (Group 2). PAINESD score and left ventricular ejection fraction were similar between the groups. Compared with Group 1, Group 2 had significantly worse NYHA functional class III or higher (25.0% vs 63.6%; P = 0.006), electrical storm (46.4% vs 77.3%; P = 0.027), and prior failed VT ablation (35.7% vs 68.2%; P = 0.023). Multivariable analysis showed that NYHA functional class III or higher and prior failed VT ablation were predictive of prolonged hospital stay. After ablation, compared with Group 1, Group 2 had worse heart failure (10.7% vs 54.5%; P = 0.001), VT recurrences (3.6% vs 68.2%; P < 0.001), and 7 deaths within 30 days. CONCLUSIONS: Patients undergoing emergent VT ablation are at high risk for prolonged hospital stay, which is predicted by NYHA functional class III or higher and a prior failed ablation. Early VT recurrences and worsening heart failure contribute to prolonged hospitalization and a high 30-day mortality.

17.
JACC Clin Electrophysiol ; 10(2): 193-202, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38069975

RESUMO

BACKGROUND: Risks of radiofrequency catheter ablation for ventricular arrhythmias include emboli and bleeding complications but data on antithrombotic regimens are limited and guidelines do not specify a systematic approach. OBJECTIVES: This study sought to assess embolic and bleeding complications in relation to pre-periprocedure and post-periprocedure antithrombotic regimens. METHODS: Prospective assessment for complications was performed for 663 endocardial radiofrequency catheter ablation procedures in 616 consecutive patients (median age 64 years [Q1-Q3: 54-73 years], 70.3% men, 71.6% with cardiomyopathy, 44.5% with sustained ventricular tachycardia). RESULTS: There were 2 strokes (0.3%; 95% CI: 0.0%-0.8%), 1 transient ischemic attack (0.15%), and 2 pulmonary emboli (0.3%). There were 39 bleeding complications (5.9%) including 11 pericardial effusions (1.7%), and 28 related to vascular access (4.2%). Consistent with the prevalence of coronary artery disease (47.5%), atrial fibrillation (30.0%), and prior stroke (10.6%), preprocedure, 464 patients (70.0%) were taking antithrombotic agents including 220 (33.2%) taking aspirin alone (ASA), and 163 (24.6%) taking warfarin or a direct acting oral anticoagulant (DOAC). Preprocedure non-ASA antiplatelet use (OR: 2.846; P = 0.011) and DOAC use (OR: 2.585; P = 0.032) were associated with risk of bleeding complications. Following ablation, 49.8% of patients were treated with ASA 325 mg/d and 30.3% received DOACs or warfarin. New DOAC or warfarin administration was initiated in only 6.6% of patients. Overall, 39.7% of patients continued the same preprocedure antithrombotic regimen. CONCLUSIONS: Stroke is a rare complication of radiofrequency catheter ablation for ventricular arrhythmia using ASA 325 mg/d as a minimal postprocedure regimen with more potent regimens for selected patients.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Masculino , Humanos , Pessoa de Meia-Idade , Feminino , Varfarina/efeitos adversos , Anticoagulantes/efeitos adversos , Hemorragia/etiologia , Hemorragia/induzido quimicamente , Fibrinolíticos , Estudos Prospectivos , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/epidemiologia , Fibrilação Atrial/cirurgia , Aspirina/efeitos adversos
18.
Circ Arrhythm Electrophysiol ; 17(6): e012635, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38804141

RESUMO

BACKGROUND: Irrigated radiofrequency ablation with half-normal saline can potentially increase lesion size but may increase the risk of steam pops with the risk of emboli or perforation. We hypothesized that pops would be preceded by intracardiac echocardiography (ICE) findings as well as a large impedance fall. METHODS: In 100 consecutive patients undergoing endocardial ventricular arrhythmia radiofrequency ablation with half-normal saline, we attempted to observe the ablation site with ICE. Radiofrequency ablation power was titrated to a 15 to 20 Ohm impedance fall and could be adjusted for tissue whitening and increasing bubble formation on ICE. Steam pops were defined as audible or a sudden explosion of microbubbles on ICE. RESULTS: Of 2190 ablation applications in 100 patients (82% cardiomyopathy, 50% sustained ventricular tachycardia), pops occurred during 43 (2.0%) applications. Sites with pops had greater impedance decreases of 18 [14, 21]% versus 13 [10, 17]% (P<0.001). ICE visualized 1308 (59.7%) radiofrequency sites, and fewer pops occurred when ICE visualized the radiofrequency ablation site (1.4%) compared with without ICE visualization (2.8%; P=0.016). Of the 18 ICE-visible pops, 7 (39%) were silent but recognized as an explosion of bubbles on ICE. With ICE, 89% of pops were preceded by either tissue whitening or a sudden increase in bubbles. In a multivariable model, tissue whitening and a sudden increase in bubbles were associated with steam pops (odds ratio, 7.186; P=0.004, and odds ratio, 29.93; P<0.001, respectively), independent of impedance fall and power. There were no pericardial effusions or embolic events with steam pops. CONCLUSIONS: Steam pops occurred in 2% of half-normal saline radiofrequency applications titrated to an impedance fall and are likely under-recognized without ICE. On ICE, steam pops are usually preceded by tissue whitening or a sudden increase in bubble formation, which can potentially be used to adjust radiofrequency application to help reduce pops.


Assuntos
Ablação por Cateter , Ecocardiografia , Solução Salina , Vapor , Taquicardia Ventricular , Irrigação Terapêutica , Humanos , Masculino , Feminino , Solução Salina/administração & dosagem , Pessoa de Meia-Idade , Ablação por Cateter/efeitos adversos , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/diagnóstico por imagem , Idoso , Embolia Aérea/prevenção & controle , Embolia Aérea/etiologia , Embolia Aérea/diagnóstico por imagem , Resultado do Tratamento , Fatores de Risco , Valor Preditivo dos Testes , Impedância Elétrica
19.
J Am Heart Assoc ; 13(6): e031029, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38471835

RESUMO

BACKGROUND: Recurrence after atrial fibrillation (AF) ablation remains common. We evaluated the association between recurrence and levels of biomarkers of cardiac remodeling, and their ability to improve recurrence prediction when added to a clinical prediction model. METHODS AND RESULTS: Blood samples collected before de novo catheter ablation were analyzed. Levels of bone morphogenetic protein-10, angiopoietin-2, fibroblast growth factor-23, insulin-like growth factor-binding protein-7, myosin-binding protein C3, growth differentiation factor-15, interleukin-6, N-terminal pro-brain natriuretic peptide, and high-sensitivity troponin T were measured. Recurrence was defined as ≥30 seconds of an atrial arrhythmia 3 to 12 months postablation. Multivariable logistic regression was performed using biomarker levels along with clinical covariates: APPLE score (Age >65 years, Persistent AF, imPaired eGFR [<60 ml/min/1.73m2], LA diameter ≥43 mm, EF <50%; which includes age, left atrial diameter, left ventricular ejection fraction, persistent atrial fibrillation, and estimated glomerular filtration rate), preablation rhythm, sex, height, body mass index, presence of an implanted continuous monitor, year of ablation, and additional linear ablation. A total of 1873 participants were included. A multivariable logistic regression showed an association between recurrence and levels of angiopoietin-2 (odds ratio, 1.08 [95% CI, 1.02-1.15], P=0.007) and interleukin-6 (odds ratio, 1.02 [95% CI, 1.003-1.03]; P=0.02). The area under the receiver operating characteristic curve of a model that only contained clinical predictors was 0.711. The addition of any of the 9 studied biomarkers to the predictive model did not result in a statistically significant improvement in the area under the receiver operating characteristic curve. CONCLUSIONS: Higher angiopoietin-2 and interleukin-6 levels were associated with recurrence after atrial fibrillation ablation in multivariable modeling. However, the addition of biomarkers to a clinical prediction model did not significantly improve recurrence prediction.


Assuntos
Fibrilação Atrial , Remodelamento Atrial , Ablação por Cateter , Humanos , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Angiopoietina-2 , Interleucina-6 , Modelos Estatísticos , Volume Sistólico , Remodelação Ventricular , Fatores de Risco , Prognóstico , Recidiva , Função Ventricular Esquerda , Biomarcadores , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Resultado do Tratamento
20.
Artigo em Inglês | MEDLINE | ID: mdl-39243256

RESUMO

BACKGROUND: Patients with rare, pathogenic cardiomyopathy (CM) and arrhythmia variants can present with atrial fibrillation (AF). The efficacy of AF ablation in these patients is unknown. OBJECTIVE: This study tested the hypotheses that: 1) patients with a pathogenic variant in any CM or arrhythmia gene have increased recurrence following AF ablation; and 2) patients with a pathogenic variant associated with a specific gene group (arrhythmogenic left ventricular CM [ALVC], arrhythmogenic right ventricular CM, dilated CM, hypertrophic CM, or a channelopathy) have increased recurrence. METHODS: We performed a prospective, observational, cohort study of patients who underwent AF catheter ablation and whole exome sequencing. The primary outcome measure was ≥30 seconds of any atrial tachyarrhythmia that occurred after a 90-day blanking period. RESULTS: Among 1,366 participants, 109 (8.0%) had a pathogenic or likely pathogenic (P/LP) variant in a CM or arrhythmia gene. In multivariable analysis, the presence of a P/LP variant in any gene was not significantly associated with recurrence (HR 1.15; 95% CI 0.84-1.60; P = 0.53). P/LP variants in the ALVC gene group, predominantly LMNA, were associated with increased recurrence (n = 10; HR 3.75; 95% CI 1.84-7.63; P < 0.001), compared with those in the arrhythmogenic right ventricular CM, dilated CM, hypertrophic CM, and channelopathy gene groups. Participants with P/LP TTN variants (n = 46) had no difference in recurrence compared with genotype-negative-controls (HR 0.93; 95% CI 0.54-1.59; P = 0.78). CONCLUSIONS: Our results support the use of AF ablation for most patients with rare pathogenic CM or arrhythmia variants, including TTN. However, patients with ALVC variants, such as LMNA, may be at a significantly higher risk for arrhythmia recurrence.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA