Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Technol Cancer Res Treat ; 2(6): 515-23, 2003 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-14640763

RESUMO

In this work, the development and applications of a fluorescence detection system using optical parametric oscillator (OPO) laser excitation for in vivo disease diagnosis including oral carcinoma are described. The optical diagnosis system was based on an OPO laser for multi-wavelength excitation and time-resolved detection. The pulsed Nd-YAG-pumped OPO laser system (6 ns, 20 Hz) is compact and has a rapid, broad, and uniform tuning range. Time-gated detection of intensified charge-coupled device (ICCD) making use of external triggering was used to effectively eliminate the laser scattering and contribute to the highly sensitive in vivo measurements. Artificial tissue-simulating phantoms consisting of polystyrene microspheres and tissue fluorophores were tested to optimize the gating parameters. 51-ns gate width and 39-ns gate delays were determined to be the optimal parameters for sensitive detection. In vivo measurements with the optical diagnosis system were applied to esophagus, stomach, and small intestine using an endoscope in canine animal studies. The rapid tuning capability of the optical diagnosis system contributed greatly to the optimization of wavelength for the observation of porphyrin in the small intestine. When the small intestine was thoroughly washed with water, the emission band which corresponds to porphyrin disappeared. Based on this observation, it was concluded that the detected signal was yielded by porphyrin-containing bile secretion. Also, multispectral analyses using multiple excitations from 415 to 480 nm at 5 nm intervals confirmed the porphyrin detection in the small intestine. The optical diagnosis system was also applied to the detection of human xenograft of oral carcinoma in mice using 5-aminolevulinic acid (5-ALA) which is a photodynamic therapy (PDT) drug. Significant differences in protoporphyrin IX fluorescence intensity between normal and tumor tissue could be obtained 2 hours after the injection of 5-ALA into mice due to the preferential accumulation of 5-ALA in tumors. Results reported herein demonstrate potential capabilities of the LIF-OPO system for in vivo disease diagnosis.


Assuntos
Diagnóstico por Imagem/instrumentação , Lasers , Óptica e Fotônica/instrumentação , Animais , Cães , Endoscopia do Sistema Digestório/métodos , Fluorescência , Camundongos , Neoplasias Bucais/diagnóstico , Imagens de Fantasmas , Porfirinas/análise , Análise Espectral
2.
J Nanosci Nanotechnol ; 2(6): 653-8, 2002 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-12908430

RESUMO

This work describes the fabrication and the application of an antibody-based fiber-optic nanosensor for in situ measurements of the carcinogen benzo[a]pyrene (BaP) in a single cell. This antibody-based spectroscopic nanosensor is miniaturized enabling the detection of fluorescent analytes in single cells. In addition to measuring fluorescent analytes in single cells, the nanosensor has the potential to be applied for both diagnostic and proteomics purposes. In this work, the human breast carcinoma cell line, MCF-7, was used as the model system to perform BaP measurements in single cells. A standard concentration curve for BaP was established and used to perform quantitative analyses of BaP in individual cells. From these analyses, it was estimated that the concentration of BaP in the individual cells investigated was approximately 3.61 x 10(-10) M. The results obtained demonstrate the application of antibody-based nanosensors for performing in situ measurements inside a single cell.


Assuntos
Benzo(a)pireno/análise , Técnicas Biossensoriais/instrumentação , Neoplasias da Mama/química , Tecnologia de Fibra Óptica/instrumentação , Nanotecnologia/instrumentação , Anticorpos , Técnicas Biossensoriais/métodos , Neoplasias da Mama/patologia , Carcinógenos/análise , Desenho de Equipamento , Humanos , Microscopia de Fluorescência/instrumentação , Microscopia de Fluorescência/métodos , Nanotecnologia/métodos , Fibras Ópticas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Células Tumorais Cultivadas/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA