Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Card Surg ; 37(8): 2367-2374, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35577768

RESUMO

BACKGROUND: Comparative data on the clinical outcomes of TTK Chitra mechanical heart valve prosthesis (CHVP), an indigenously developed low-cost tilting disc valve and commonly used bileaflet valve, the St. Jude medical (SJM) prosthesis are sparse. METHODS: We conducted a retrospective follow-up study of consecutive patients undergoing mitral (MVR) and aortic valve replacement (AVR) with SJM or CHVP mechanical prostheses over a 6-year period at our institution. RESULTS: Seven hundred and thirty-five patients who underwent isolated MVR (n = 510) or AVR (n = 225) were included in the study. Patients with CHVP were younger and belonged to a lower socioeconomic class. The study cohort was followed-up for 2836 patient-years (SJM: 1865.1, CHVP: 971.0). All-cause mortality (p = 0.894), valve-related mortality (p = 0.681), prosthetic valve thrombosis (p = 0.155), embolism (p = 0.210), hemorrhage (p = 0.959) and infective endocarditis (IE, p = 0.084) were similar between both valve on follow-up. Estimated event free survival was 2302 ± 1 days in SJM as compared to 2484 ± 65 days in CHVP group (p = 0.393). Valve type was not an independent predictor of adverse events after adjusting for baseline data, time in therapeutic range and aspirin use. Subgroup analysis of patients who underwent MVR and AVR showed similar functional improvement and outcomes, except for a higher incidence of IE with SJM at the aortic position (p = 0.041). CONCLUSION: The indigenously developed, low-cost CHVP has comparable midterm clinical performance as SJM in aortic or mitral positions.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Aórtica/cirurgia , Proteínas de Ciclo Celular , Ligas Dentárias , Seguimentos , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Valva Mitral/cirurgia , Desenho de Prótese , Proteínas Serina-Treonina Quinases , Proteínas Tirosina Quinases , Estudos Retrospectivos
2.
J Emerg Trauma Shock ; 7(3): 149-54, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25114422

RESUMO

UNLABELLED: Acute flaccid paralysis (AFP) is a complex clinical syndrome with a broad array of potential etiologies that vary with age. We present our experience of acute onset lower motor neuron paralysis. MATERIALS AND METHODS: One hundred and thirty-three consecutive adult patients presenting with weakness of duration less than four weeks over 12 months period were enrolled. Detailed history, clinical examination, and relevant investigations according to a pre-defined diagnostic algorithm were carried out. The patients were followed through their hospital stay till discharge or death. RESULTS: The mean age was 33.27 (range 13-89) years with male preponderance (67.7%). The most common etiology was neuroparalytic snake envenomation (51.9%), followed by Guillain Barre syndrome (33.1%), constituting 85% of all patients. Hypokalemic paralysis (7.5%) and acute intermittent porphyria (4.5%) were the other important conditions. We did not encounter any case of acute polio mylitis in adults. In-hospital mortality due to respiratory paralysis was 9%. CONCLUSION: Neuroparalytic snakebite and Guillain Barre syndrome were the most common causes of acute flaccid paralysis in adults in our study.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA